Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 2 - 2
1 Apr 2018
Jo S Lee S Kang S
Full Access

Introduction. The correct anteversion of the acetabular cup is critical to achieve optimal outcome after total hip arthroplasty. While number of method has been described to measure the anteversion in plane anteroposterior and lateral radiograph, it is still controversial which method provides best anteversion measurement. While many of the previous studies used CT scan to validate the anteversion measured in plane anteroposterior radiograph, this may cause potential bias as the anteversion measured in CT scan reflects true anteversion while the anteversion measurement methods in plane radiograph are design to measure the planar anteversion. Thus, in the current study, we tried to find the optimal anteversion measurement method free from the previously described bias. Material and method. Custom made cup model was developed which enables change in anteversion and inclination. Simple radiograph was taken with the cup in 10° to 70° degree of inclination at 10° increments and for each inclination angle, anteversion was corrected from 0° to 30° at 5° increments. The radiograph was taken with the beam directed at the center of the cup (mimicking hip centered anteroposterior radiograph) and at 9cm medial to the cup (mimicking pelvis anteroposterior radiograph). The measurements were done by two orthopaedic surgeons using methods described by 1) Pradhan et al, 2) Lewinak et al, 3) Widmer et al, and 4) Liaw et al. For each measurements, the anteversion were compared with the actual anteversion. Result. Interoverver correlation (kappa value) were high in all measurements ranging 0.988 to 0.998. Regardless of how the radiograph was taken, Pradhan method was the most accurate measurement method showing difference of 2.17° ± 1.69° and −2.5° ± 1.93° compare to the actual anteversion respectively for hip centered radiograph and pelvis anteroposterior radiograph. The Widmer method showed the least accuracy (pelvis AP : −6.75° ± 4.62°, hip centered AP : −14.84° ± 4.36°). However, when the anteversion were measured in the safe zone with the inclination in 30° to 50° Liaw's method in hip centered radiograph showed the highest accuracy (1.63° ± 1.4°). Conclusion. The study indicates that the Pradhan's method may provide the most accurate anteversion measurement. However, with the hip in 30° to 50° inclination, Liaw's method measured from hip centred radiograph will provide most accurate anteversion measurement


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 32 - 32
1 Feb 2017
Barnes L
Full Access

Introduction

When performing a total hip arthroplasty (THA), some surgeons routinely perform an intraoperative anteroposterior (AP) pelvis radiograph to assess components. The purpose of this study was to evaluate the reliability of the intraoperative radiograph to accurately reflect acetabular inclination, leg length, and femoral offset as compared to the immediate postoperative supine AP radiograph.

Methods

The intraoperative (lateral decubitus position) and immediate postoperative (supine position) AP pelvis x-rays of 100 consecutive patients undergoing primary THA were retrospectively reviewed. Acetabular inclination, leg length, and femoral offset were measured on both radiographs. We analyzed the correlation coefficient of the recorded measurements between the two films as well as the interobserver reliability of each measurement obtained.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 411 - 411
1 Dec 2013
Maruyama M Tensho K Wakabayashi S Hisa K
Full Access

BACKGROUND:. Although most radiographs used for polyethylene wear measurements have been taken with the patient in the supine position in order to assess penetration by the femoral head into the acetabular polyethylene socket, we have questioned the effect of weight-bearing on the position of the head within the socket. The current study aimed to determine the effect of weight bearing, i.e. standing on the two-dimensional radiographic position of the femoral head within the socket. PATIENTS AND METHODS:. A total of three hundred and fifty patients (three hundred and eighty three hips) who had had a total hip arthroplasty had digital radiographs made a set of anteroposterior radiographs for each patient: one radiograph was made with the patient supine and one was made with the patient standing in full weight bearing on the replaced hip. The patients were divided into the following two groups: 1) seventy-five patients (eighty-three hips) with conventional polyethylene (CON) (group-1); 2) two hundred and seventy-five patients (three hundred hips) with highly cross-linked polyethylene (XPL) (group-2). The set of radiograph was taken at three weeks postoperatively and at the time of semiannual follow-up. The average ceramic femoral head penetration was measured with radiographs taken in the standing or supine position at the final follow-up and compared with those of three weeks postoperatively. A single researcher with use of a computerized measurement system performed all measurements on the radiographs of the two-dimensional position of the head. Follow-up period were 13.5 ± 1.0 (range. 11.0–15.5) years in group-1 and 7.6 ± 2.1 (range. 5.0–12.6) years in group-2. RESULTS:. Linear penetration rates in group-1 were 0.172 ± 0.069 mm/year in supine position and 0.178 ± 0.069 mm/year in standing position (p < 0.05, paired t-test; r. 2. = 0.88), and the rates in group-2 were 0.029 ± 0.024 mm/year and 0.035 ± 0.027 mm/year respectively (p < 0.0005, paired t-test; r. 2. = 0.16). The mean ceramic head penetration rate in XPL socket showed 80 to 83% reduction compared with those in CON. CONCLUSIONS:. We found significant difference between the average total ceramic femoral head penetration between supine and standing radiographs in using both CON and XPL socket. Standing radiographs were useful and recommended for polyethylene socket wear measurements. Figure legend. Fig. Wear measurement: With use of a computerized measurement system, the thickness of the polyethylene socket (a) was measured along a line connecting the center of the ceramic femoral head to the outer border of the socket at its shortest distance. The wear rate was determined by comparing the thickness in the latest follow up radiograph with the thickness in the initial postoperative radiograph at the same location. Each radiographically measured value was corrected for magnification by a factor derived from comparing the diameter of the ceramic head on the radiograph (b) with its known diameter of 22.225 mm


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 51 - 51
1 Aug 2013
Sampath S Lewis S Fosco M Tigani D
Full Access

Introduction. Wolff's Law proposes that trabecular bone adapts in response to mechanical loading and that trabeculae align with the trajectory of predominant loads. The current study is aimed to investigate trabecular orientation in the tibia in patients with osteoarthritis of the knee. Consistent with Wolff's Law, it was hypothesised that orientation would reflect the mechanical loading of the joint and hence that there would be a correlation between the trabecular orientation and the mechanical axis of the lower limb. Methods. 51 anonymised radiographs from patients with osteoarthritis were analysed using ImageJ (National Institute of Health). Each patient had both a standard anteroposterior radiograph of the knee and a long leg view taken while weight bearing. For each anteroposterior radiograph, the angle of the femoral shaft and tibial shaft were measured. The femoral shaft – tibial shaft (FS -TS) angle was then calculated as the difference between the two, as described by Sheehy et al. (2011). A medial rectangle was selected with the top, bottom, medial and lateral borders being the sclerotic bone, the growth line, the bone edge and the centre of the medial tibial spine. Corresponding measurements were done on the lateral side. Trabecular orientation of both areas was measured using OrientationJ (an ImageJ plugin). In all cases the medial and lateral orientation angles were expressed relative to the angle of the tibial shaft. The mechanical axis of the lower limb was measured from the full length radiographs by calculating the angle formed by the femoral and tibial axes, as described by Goker and Block. All measurements were done independently by two observers, SAS and SL. Results. Except where indicated, the results are based on analysis of 51 radiographs. Inter-tester analysis indicated excellent reliability (ICC = 0.99) for the mechanical axis measurement and preliminary inter-tester analysis (based on 25 radiographs) indicated good reliability for the orientation measurements (ICC = 0.76). The FS-TS angle calculated from the anteroposterior radiographs was significantly correlated with the mechanical axis calculated from the full-leg views (r = 0.96, p < 0.01), with an average offset of 5.7°, which is consistent with previous research. There was a significant correlation between the lateral trabecular orientation and both the FS-TS angle measured from the anteroposterior radiographs (r = −0.48, p < 0.01) (Figure) and the mechanical axis measured from the long leg views (r = −0.39, p < 0.01). There was also a significant correlation between the medial trabecular orientation and the FS-TS angle (r = 0.35, p = 0.01). Discussion. There were significant correlations between leg alignment (both the mechanical axis and the FS − TS angle) and trabecular orientation in the human tibia. These findings were consistent with Wolff's Law, which proposes that trabecular bone adapts in response to mechanical loading. To the best of our knowledge, the current study is the first to investigate in vivo trabecular orientation in the human tibia and to establish a correlation with the mechanical axis of the lower limb. The findings also suggest that inspection of the trabecular orientation might provide valuable information on leg alignment and mechanical loading prior to surgery


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 13 - 13
1 Dec 2022
Reeves J Spangenberg G Elwell J Stewart B Vanasse T Roche C Faber KJ Langohr GD
Full Access

Shoulder arthroplasty humeral stem design has evolved to accommodate patient anatomy characteristics. As a result, stems are available in numerous shapes, coatings, lengths, sizes, and vary by fixation method. This abundance of stem options creates a surgical paradox of choice. Metrics describing stem stability, including a stem's resistance to subsidence and micromotion, are important factors that should influence stem selection, but have yet to be assessed in response to the diametral (i.e., thickness) sizing of short stem humeral implants. Eight paired cadaveric humeri (age = 75±15 years) were reconstructed with surgeon selected ‘standard’ sized short-stemmed humeral implants, as well as 2mm ‘oversized’ implants. Stem sizing conditions were randomized to left and right humeral pairs. Following implantation, an anteroposterior radiograph was taken of each stem and the metaphyseal and diaphyseal fill ratios were quantified. Each humerus was then potted in polymethyl methacrylate bone cement and subjected to 2000 cycles of 90º forward flexion loading. At regular intervals during loading, stem subsidence and micromotion were assessed using a validated system of two optical markers attached to the stem and humeral pot (accuracy of <15µm). The metaphyseal fill ratio did not differ significantly between the oversized and standard stems (0.50±0.06 vs 0.50±0.10; P = 0.997, Power = 0.05); however, the diaphyseal fill ratio did (0.52±0.06 vs 0.45±0.07; P < 0.001, Power = 1.0). Neither fill ratio correlated significantly with stem subsidence or micromotion. Stem subsidence and micromotion were found to plateau following 400 cycles of loading. Oversizing stem thickness prevented implant head-back contact in all but one specimen with the least dense metaphyseal bone, while standard sizing only yielded incomplete head-back contact in the two subjects with the densest bone. Oversized stems subsided significantly less than their standard counterparts (standard: 1.4±0.6mm, oversized: 0.5±0.5mm; P = 0.018, Power = 0.748;), and resulted in slightly more micromotion (standard: 169±59µm, oversized: 187±52µm, P = 0.506, Power = 0.094,). Short stem diametral sizing (i.e., thickness) has an impact on stem subsidence and micromotion following humeral arthroplasty. In both cases, the resulting three-dimensional stem micromotion exceeded, the 150µm limit suggested for bone ingrowth, although that limit was derived from a uniaxial assessment. Though not statistically significant, the increased stem micromotion associated with stem oversizing may in-part be attributed to over-compacting the cancellous bed during broaching, which creates a denser, potentially smoother, interface, though this influence requires further assessment. The findings of the present investigation highlight the importance of proper short stem diametral sizing, as even a relatively small, 2mm, increase can negatively impact the subsidence and micromotion of the stem-bone construct. Future work should focus on developing tools and methods to support surgeons in what is currently a subjective process of stem selection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 80 - 80
1 Dec 2022
Reeves J Spangenberg G Elwell J Stewart B Vanasse T Roche C Langohr GD Faber KJ
Full Access

Shoulder arthroplasty is effective at restoring function and relieving pain in patients suffering from glenohumeral arthritis; however, cortex thinning has been significantly associated with larger press-fit stems (fill ratio = 0.57 vs 0.48; P = 0.013)1. Additionally, excessively stiff implant-bone constructs are considered undesirable, as high initial stiffness of rigid fracture fixation implants has been related to premature loosening and an ultimate failure of the implant-bone interface2. Consequently, one objective which has driven the evolution of humeral stem design has been the reduction of stress-shielding induced bone resorption; this in-part has led to the introduction of short stems, which rely on metaphyseal fixation. However, the selection of short stem diametral (i.e., thickness) sizing remains subjective, and its impact on the resulting stem-bone construct stiffness has yet to be quantified. Eight paired cadaveric humeri (age = 75±15 years) were reconstructed with surgeon selected ‘standard’ sized and 2mm ‘oversized’ short-stemmed implants. Standard stem sizing was based on a haptic assessment of stem and broach stability per typical surgical practice. Anteroposterior radiographs were taken, and the metaphyseal and diaphyseal fill ratios were quantified. Each humerus was then potted in polymethyl methacrylate bone cement and subjected to 2000 cycles of compressive loading representing 90º forward flexion to simulate postoperative seating. Following this, a custom 3D printed metal implant adapter was affixed to the stem, which allowed for compressive loading in-line with the stem axis (Fig.1). Each stem was then forced to subside by 5mm at a rate of 1mm/min, from which the compressive stiffness of the stem-bone construct was assessed. The bone-implant construct stiffness was quantified as the slope of the linear portion of the resulting force-displacement curves. The metaphyseal and diaphyseal fill ratios were 0.50±0.10 and 0.45±0.07 for the standard sized stems and 0.50±0.06 and 0.52±0.06 for the oversized stems, respectively. Neither was found to correlate significantly with the stem-bone construct stiffness measure (metaphysis: P = 0.259, diaphysis: P = 0.529); however, the diaphyseal fill ratio was significantly different between standard and oversized stems (P < 0.001, Power = 1.0). Increasing the stem size by 2mm had a significant impact on the stiffness of the stem-bone construct (P = 0.003, Power = 0.971; Fig.2). Stem oversizing yielded a construct stiffness of −741±243N/mm; more than double that of the standard stems, which was −334±120N/mm. The fill ratios reported in the present investigation match well with those of a finite element assessment of oversizing short humeral stems3. This work complements that investigation's conclusion, that small reductions in diaphyseal fill ratio may reduce the likelihood of stress shielding, by also demonstrating that oversizing stems by 2mm dramatically increases the stiffness of the resulting implant-bone construct, as stiffer implants have been associated with decreased bone stimulus4 and premature loosening2. The present findings suggest that even a small, 2mm, variation in the thickness of short stem humeral components can have a marked influence on the resulting stiffness of the implant-bone construct. This highlights the need for more objective intraoperative methods for selecting stem size to provide guidelines for appropriate diametral sizing. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 97 - 97
1 Apr 2019
Vigdorchik J Cizmic Z Novikov D Meere PA Schwarzkopf R Buckland A
Full Access

Introduction. A comprehensive understanding of pelvic orientation prior to total hip arthroplasty is necessary to allow proper cup positioning and mitigate the risks of complications associated with component malpositioning. Measurements using anteroposterior (AP) radiographs have been described as effective means of accurately predicting pelvic orientation. The purpose of our study was to describe the inter- and intra-observer reliability and predictive accuracy of predicting pelvic tilt using AP radiographs. Methods. Five fellowship-trained orthopaedic surgeons independently analyzed pelvic tilt, within 10 degrees, for 50 different AP pelvis radiographs. All surgeons were blinded to patient information, diagnosis, and correct measurements prior to analysis. Responses were then compared to correct measurements using sitting-standing AP and lateral stereoradiographs. Results. The average correct predictive value of pelvic tilt between all surgeons was 54%. The intra-observer accuracy of predicting pelvic tilt ranged from 48% to 64%. Discussion. Pelvic tilt cannot be accurately predicted using anteroposterior radiographs. Pre-operative evaluation of pelvic parameters requires multiple views for detailed assessment. Therefore, lateral radiographs are required for accurate prediction of pelvic tilt


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 51 - 51
1 May 2021
Abood AA Petruskevicius J Vogt B Frommer A Rödl R Rölfing JD
Full Access

Introduction. Intraoperative assessment of coronal alignment is important when performing corrective osteotomies around the knee and ankle, limb lengthening and trauma surgery. The Joint Angle Tool (JAT) provides surgeons with information about the anatomic and mechanical axes intraoperatively based on true anteroposterior radiographs. Aim: Presentation of the JAT, a low-cost goniometer for intraoperative assessment of the lower limb alignment. Materials and Methods. The JAT consists of pre-printed joint orientation angles of the anatomic and mechanical axis including normal variations on a plastic sheet. It is placed on the screen of the image intensifier after obtaining a true anterior-posterior image. The pre-printed joint orientation angles can intraoperatively assist the surgeons in achieving the pre-planned axis correction. Here, its feasibility is demonstrated in four cases. Results. Here, we present the intraoperative use of JAT in four cases:. 77 mm femoral bone transport due to non-union utilizing a bone transport nail,. distal femoral osteotomy correcting coronal and torsional malalignment using a retrograde intramedullary trauma nail,. proximal / high tibial open wedge osteotomy with an intramedullary implant correcting varus malalignment in a hypophosphatemic rickets patient, and. a supramalleolar, closing wedge osteotomy realigning the anatomic axis with a plate and screws. Conclusions. The JAT is a modified goniometer which allows intraoperative assessment of the mechanical and anatomic axis. JAT is applicable throughout the entire surgical procedure irrespective of the method of internal fixation and may provide additional reassurance of correct alignment. The JAT consists of a plastic sheet with printed joint orientation angles and their normal variation. JAT is freely available from . profeedback.dk/JAT/JAT.pdf. for use and modification according to Creative Commons license (CC BY-SA 4.0)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 116 - 116
23 Feb 2023
Chai Y Khadra S Boudali A Darwish I Walter W
Full Access

Accurate measurement of pelvic tilt (PT) is critical in diagnosing hip and spine pathologies. Yet a sagittal pelvic radiograph with good quality is not always available. Studies explored the correlation between PT and sacro-femoral-pubic (SFP) angle from anteroposterior (AP) radiographs yet demonstrated conflicting conclusions about its feasibilities. This study aims to perform a cohort-controlled meta-analysis to examine the correlation between the SFP angle and PT and proposes an application range of the method. This study searched PubMed, Embase, Cochrane, and Web of Science databases for studies that evaluated the correlation between SFP angle and PT. The Pearson's correlation coefficient r from studies were tabulated and compared. Pooled r for overall and gender/age (teenage or adult) controlled subgroup were reported using Fisher's Z transformation. Heterogeneity and publication bias were evaluated using Egger's regression test for the funnel plot asymmetry. Eleven studies were recruited, with nine reported r (totalling 1,247 patients). The overall pooled r was 0.61 with high inter-study heterogeneity (I2 = 75.95%). Subgroup analysis showed that the adult group had a higher r than the teenage group (0.70 versus 0.56, p < 0.001). Although statistically insignificant (p = 0.062), the female group showed a higher r than the male group (0.72 versus 0.65). The SFP method must be used with caution and should not be used in the male teenage group. The current studies did not demonstrate that the SFP method was superior to other AP landmarks correlating to PT. Identical heterogeneity was observed among studies, indicating that more ethnicity-segregated and gender-specific subgroup studies might be necessary. More data input analysing the errors will be useful


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 5 - 5
1 Nov 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Tibial cut is a crucial step in ensuring adequate and appropriate proximal tibial resection for mechanical orientation and axis in total knee replacement. We evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects individual mechanical orientation and alignment. We used Condylar Differential in 37 consecutive total knee replacements including valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis. The distances between the horizontal line and the lowest reproducible points of articular surfaces of medial and lateral tibial condyles respectively are measured. The difference between two measurements obviously represents Condylar Differential. Condylar Differential, adjusted to the nearest millimetre, is maintained in executing tibial cuts, successively if necessary. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualises the tibial cut for optimal templating of tibia. We encountered no problems, adopting this technique, in our series. Condylar Differential contributes to optimal individualised tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique in digitised radiographs, this technique can also be applied to plain films, allowing for magnification


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 6 - 6
1 Jul 2020
Yasuda T Onishi E Ota S Fujita S Sueyoshi T Hashimura T
Full Access

Rapidly progressive osteoarthritis of the hip (RPOH) is an unusual subset of osteoarthritis. It is characterized by rapid joint space loss, chondroly­sis, and sometimes marked femoral head and acetabular destruction as a late finding. The exact pathogenetic mechanism is unknown. Potential causes of RPOH include subchondral insufficiency fracture resulting from osteoporosis, increasing posterior pelvic tilt as a mechanical factor, and high serum levels of matrix metalloproteinase (MMP)-3 as biological factors. This study was aimed to identify some markers that associate with the destructive process of RPOH by analyzing the proposed pathological factors of the disease, MMP-3, pelvic tilt, and osteoporosis. Of female patients who visited our hospital with hip pain from 2012 through 2018, this study enrolled female patients with sufficient clinical records including the onset of hip pain, age and body mass index (BMI) at the onset, a series of radiographs during the period of >12 months from the onset of hip pain, and hematological data of MMP-3 and C-reactive protein (CRP). We found the hip joints of 31 patients meet the diagnostic criteria of RPOH, chondrolysis >two mm in one year, or 50% joint space narrowing in one year. Those patients were classified into two groups, 17 and 14 patients with and without subsequent femoral head destruction in one year shown by computed tomography, respectively. Serum MMP-3 and CRP were measured with blood samples within one year after the hip pain onset. The cortical thickness index (CTI) as an indicator of osteoporosis and pelvic tilt parameters were evaluated on the initial anteroposterior radiograph of the hip. These factors were statistically compared between the two groups. This study excluded male patients because RPOH occurs mainly in elderly females and the reference intervals of MMP-3 are different between males and females. There was no difference in age at onset or bone mass index between the RPOH patients with and without subsequent femoral head destruction. Serum levels of MMP-3 were significantly higher in the RPOH patients with the destruction (152.1 ± 108.9 ng/ml) than those without the destruction (66.8 ± 27.9 ng/ml) (P = 0.005 by Mann-Whitney test). We also found increased CRP in the patients with femoral head destruction (0.725 ± 1.44 mg/dl) compared with those without the destruction (0.178 ± 0.187 mg/dl) (P = 0.032 by Mann-Whitney test). No difference in the duration between the hip pain onset and the blood examination was found between the two groups. There was no significant difference in CTI or pelvic tilt between the two groups. The pathological condition that may increase serum MMP-3 and CRP could be involved in femoral head destruction after chondrolysis of the hip in patients with RPOH


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 27 - 27
1 Aug 2020
Abdic S Athwal G Wittman T Walch G Raiss P
Full Access

The use of shorter humeral stems in reverse shoulder arthroplasty has been reported as safe and effective. Shorter stems are purported to be bone preserving, easy to revise, and have reduced surgical time. However, a frequent radiographic finding with the use of uncemented short stems is stress shielding. Smaller stem diameters reduce stress shielding, however, carry the risk of varus or valgus malalignment in the metadiaphyseal region of the proximal humerus. The aim of this retrospective radiographic study was to measure the true post-operative neck-shaft (N-S) angle of a curved short stem with a recommended implantation angle of 145°. True anteroposterior radiographs of patients who received RTSA using an Ascend Flex short stem at three specialized shoulder centres (London, ON, Canada, Lyon, France, Munich, Germany) were reviewed. Radiographs that showed the uncemented stem and humeral tray in orthogonal view without rotation were included. Sixteen patients with proximal humeral fractures or revision surgeries were excluded. This yielded a cohort of 124 implant cases for analysis (122 patients, 42 male, 80 female) at a mean age of 74 years (range, 48 – 91 years). The indications for RTSA were rotator cuff deficient shoulders (cuff tear arthropathy, massive cuff tears, osteoarthritis with cuff insufficiency) in 78 patients (63%), primary osteoarthritis in 41 (33%), and rheumatoid arthritis in 5 (4%). The humeral component longitudinal axis was measured in degrees and defined as neutral if the value fell within ±5° of the humeral axis. Angle values >5° and < 5 ° were defined as valgus and varus, respectively. The filling-ratio of the implant within the humeral shaft was measured at the level of the metaphysis (FRmet) and diaphysis (FRdia). Measurements were conducted by two independent examiners (SA and TW). To test for conformity of observers, the intraclass correlation coefficient (ICC) was calculated. The inter- and intra-observer reliability was excellent (ICC = 0.965, 95% confidence interval [CI], 0.911– 0.986). The average difference between the humeral shaft axis and the humeral component longitudinal axis was 3.8° ± 2.8° (range, 0.2° – 13.2°) corresponding to a true mean N-S angle of 149° ± 3° in valgus. Stem axis was neutral in 70% (n=90) of implants. Of the 34 malaligned implants, 82% (n=28) were in valgus (mean N-S angle 153° ± 2°) and 18% (n=6) in varus position (mean N-S angle 139° ± 1°). The average FRmet and FRdiawere 0.68 ± 0.11 and 0.72 ± 0.11, respectively. No association was found between stem diameter and filling ratios (FRmet, FRdia) or cortical contact with the stem (r = 0.39). Operative technique and implant design affect the ultimate positioning of the implant in the proximal humerus. This study has shown, that in uncemented short stem implants, neutral axial alignment was achieved in 70% of cases, while the majority of malaligned humeral components (86%) were implanted in valgus, corresponding to a greater than 145° neck shaft angle of the implant. It is important for surgeons to understand that axial malalignment of a short stem implant does influence the true neck shaft angle


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 79 - 79
1 Feb 2020
Kusano T Takegami Y Seki T Osawa Y
Full Access

Background. There are few reports including natural course of initial gap in total hip arthroplasty. The purpose of this study is to investigate the incidence of initial gap in the PSL type shells and its natural course. Methods. Total of 386 THAs with Trident or TriAD PSL shells were performed between January 2000 and December 2014. Exclusion criteria were shells with screw fixations (n=189), previous pelvic osteotomy (n=15) and less than 3 years’ follow-up (n=11). Finally, our study included 171 hips. Average age was 56.8 (17∼83) years at THA and average follow-up time was 8.3 (3∼16.3) years; 112 (66%) were women; and 120 hips (70.2%) had osteoarthrosis. As radiographic evaluation, we checked presence or absence of initial gap, maximum size of it, gap filling and cup stability. The presence of initial gap was defined as gap present on post-operative anteroposterior X-ray measuring 1mm or greater. Gap filling was defined as confirmed trabecular formation between the cup and acetabular floor without cup migration. And we determined the time to gap filling. As clinical evaluation, we retrospectively checked Harris Hip Score (HHS) at pre-operative and final follow-up period, and presence of shell revision. Furthermore, we compared clinical results with or without initial gap. Results. Initial gap was confirmed at 85 hips (49.7%) and mean maximum size was 2.1 (1∼6.3) mm. Mean gap filling occurred at 2.5 (± 1.4) years and there was no unstable cup. Comparing clinical results with or without initial gap, pre-operative HHS was not significantly associated with initial gap (57.8 and 56.3, respectively, p=0.41). HHS at final follow-up period was also not significantly associated with initial gap (88.4 and 87.5, respectively, p=0.49). There was no shell revision with or without initial gap. Discussion. Initial gap of hemispherical type shell is reported that its incidence is 16∼38% and initial gap is not associated with clinical outcome. Our results show that PSL type shell occurs initial gap more frequently than hemispherical type shells. Conclusion. Initial gap of PSL type shell was confirmed at 85 hips (49.7%) and mean gap filling occurred at 2.5 years. Initial gap did not affect shell revision and clinical outcome


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 248 - 248
1 Mar 2013
Maeda T Kabata T Kajino Y Hayashi H Iwai S Kuroda K Fujita K Tsuchiya H
Full Access

Introduction. Intramedullary femoral alignment guide is mostly used in total knee arthroplasty (TKA). Accurate preoperative plan is critical to get good alignments when we use intramedullary femoral guide, because the center of femoral head cannot be looked directly during operation. Commonly, the planning is carried out using preoperative anteroposterior radiographs of the femur. The angles formed between mechanical axes of the femur and distal femoral anatomic axes (AMA) are measured as reference angles of resection of distal femur, and the entry points of intramedullary femoral guide are also planned. The purpose of this study is to investigate the influence of femoral position on radiographic planning in TKA. Materials and Methods. We examined 20 knees of 20 female patients who received TKA. Fourteen patients suffered from primary osteoarthritis of the knees, and 6 suffered from rheumatoid arthritis. Fifteen patients have varus knee deformities and 5 patients have valgus knee deformities. Long leg computed topography scans were performed in all cases before operations, and all images were stored in DICOM file format. The analyses were performed with computer software (3D template, JMM, Osaka, Japan) using DICOM formatted data. The planes containing the center of femoral head and transepicondylar axes were defined as reference planes, and the reference planes were fixed all through analyses. At first, to assess the influence of femoral rotation, the femur was rotated from 30 degrees external rotation to 30 degrees internal rotation in 5 degrees increments in full extension. After that, to examine the influence of knee flexion, the knee was bended from full extension to 30 degrees flexion in 5 degrees increments in neutral rotation. Reconstructed coronal planes parallel to the reference planes were made, the angles between mechanical axes of the femur and distal femoral anatomic axes (AMA) and the distance from entry points to the center of femoral intercondylar notch were measured in each position. The distal anatomic axes were made by connecting the center of femoral canal at 8 centimeters proximal to joint line and that at 16 centimeters proximal to joint line. The entry points of intramedullary femoral guide were defined the points where distal anatomic axes meets intercondylar notch. Results. The mean AMA was 6.8 degrees in neutral position, 7.1 degrees in 10 degrees external rotation, 7.3 in 20 degrees external rotation, 7.2 in 30 degrees external rotation, 6.2 in 10 degrees internal rotation, 5.5 in 20 degrees internal rotation, 4.6 in 30 degrees internal rotation, 6.9 in 10 degrees flexion, 7.2 in 20 degrees flexion, 7.8 in 30 degrees flexion, respectively. The entry points moved 3.9 millimeters laterally in 20 degrees external rotation and 3.6 millimeters medially in 20 degrees internal rotation relative to neutral position. Discussion and Conclusion. Femoral position affected on preoperative planning using anteroposterior radiographs. It is important to get a correct anteroposerior view of total femur, because the femur was easy to rotate in knee disorders


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 67 - 67
1 Apr 2019
Goldberg T Torres A Bush JW Mahometa MJ
Full Access

INTRODUCTION. The Dorr Bone Classification, devised in 1993 is commonly used to categorize bone types prior to hip reconstruction. The purpose of the present study is to quantify the Dorr classification system using 4 morphologic parameters – morphologic cortical index (MCI), canal-flare index (CFI), canal-bone ratio (CBR), and canal-calcar ratio (CCR). METHODS. 816 hips were reviewed. Demographic data reviewed includes age, sex, and laterality. Each hip was reviewed by 2 separate evaluators for Dorr classification. The MCI, CCR, CBR, and CFI were calculated for each hip on anteroposterior radiographs (Fig 1). One-way ANOVA statistical analysis was used to examine if there are mean differences for each measurement. IRB approval was obtained before collection of data. RESULTS. The average age of patients was 61 (range 20–96). There were 367 left hips and 449 right hips. The prevalence of Dorr A was 45.8%. The prevalence of Dorr B bone was 38.9% and of Dorr C bone was 15.3%. One-way ANOVA analysis confirmed the mean differences for each measurement. Measurements of the MCI, CCR, CBR, and CFI were statistically significantly different between the three types of bone. The MCI and CFI were significantly higher in Type A than Type B and higher in Type B than Type C. The CBR and CCR were significantly lower in Type A than Type B and lower in Type B than Type C. DISCUSSION. To our knowledge, the present study is the first to attempt to quantify the Dorr Bone classification system using MCI, CCR, CBR, and CFI using a large series of patients. Classification of the proximal femur geometry is important as it may play a role in implant fixation for patients undergoing total hip arthroplasty (THA). Furthermore, this information can be used to guide future implant choices


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 145 - 145
1 Apr 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Background. Mechanics and kinematics of the knee following total knee replacement are related to the mechanics and kinematics of the normal knee. Restoration of neutral alignment is an important factor affecting the long-term results of total knee replacement. Tibial cut is a vital and crucial step in ensuring adequate and appropriate proximal tibial resection, which is essential for mechanical orientation and axis in total knee replacement. Tibial cut must be individually reliable, reproducible, consistent and an accurate predictor of individual anatomical measurements. Conventional tibial cuts of tibia with fixed measurements cannot account for individual variations. While computer navigated total knee replacement serves as a medium to achieve this objective, the technology is not universally applicable for differing reasons. Therefore we evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects the individual mechanical orientation and alignment. Methods. We used the Condylar Differential in 37 consecutive total knee replacements. We also applied the technique in valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on the digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis of tibia. The distances between the horizontal line and the lowest reproducible points of the articular surfaces of the medial and lateral tibial condyles respectively are measured. The difference between the two measurements obviously represents the Condylar Differential. Condylar Differential, adjusted to the nearest millimeter, is maintained in executing the tibial cuts, if necessary successive cuts. Results. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualizes the tibial cut for optimal templating of tibia in total knee replacement. We encountered no problems, adopting this technique, in our consecutive series of total knee replacements. Conclusions. Condylar Differential contributes to optimal individualized tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique of Condylar Differential in digitized radiographs, this technique can also be applied to plain films, allowing for the magnification


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 34 - 34
1 May 2019
Rajgopal A
Full Access

Management of a knee with valgus deformities has always been considered a major challenge. Total knee arthroplasty requires not only correction of this deformity but also meticulous soft tissue balancing and achievement of a balanced rectangular gap. Bony deformities such as hypoplastic lateral condyle, tibial bone loss, and malaligned/malpositioned patella also need to be addressed. In addition, external rotation of the tibia and adaptive metaphyseal remodeling offers a challenge in obtaining the correct rotational alignment of the components. Various techniques for soft tissue balancing have been described in the literature and use of different implant options reported. These options include use of cruciate retaining, sacrificing, substituting and constrained implants. Purpose. This presentation describes options to correct a severe valgus deformity (severe being defined as a femorotibial angle of greater than 15 degrees) and their long term results. Methods. 34 women (50 knees) and 19 men (28 knees) aged 39 to 84 (mean 74) years with severe valgus knees underwent primary TKA by a senior surgeon. A valgus knee was defined as one having a preoperative valgus alignment greater than 15 degrees on a standing anteroposterior radiograph. The authors recommend a medial approach to correct the deformity, a minimal medial release and a distal femoral valgus resection of angle of 3 degrees. We recommend a sequential release of the lateral structures starting anteriorly from the attachment of ITB to the Gerdy's tubercle and going all the way back to the posterolaetral corner and capsule. Correctability of the deformity is checked sequentially after each release. After adequate posterolateral release, if the tibial tubercle could be rotated past the mid-coronal plate medially in both flexion and extension, it indicated appropriate soft tissue release and balance. Fine tuning in terms of final piecrusting of the ITB and or popliteus was carried out after using the trial components. Valgus secondary to an extra-articular deformity was treated using the criteria of Wen et al. In our study the majority of severe valgus knees (86%) could be treated by using unconstrained (CR, PS) knee options reserving the constrained knee / rotating hinge options only in cases of posterolateral instability secondary to an inadequate large release or in situations with very lax or incompetent MCL. Results. The average follow up was 10 years (range 8 to 14 years). The average HSS knee scores improved from 48 points preoperatively (range 32 to 68 points) to 91 points (range 78 to 95 points) postoperatively. The average postoperative range of motion measured with a goniometer was 110 degrees (range 80 to 135 degrees) which was a significant improvement over the preoperative levels (average 65 degrees). None of the patients were clinically unstable in the medioloateral or anteroposterior plane at the time of final follow up. The average preoperative valgus tibiofemoral alignment was 19.6 degrees (range 15 degrees to 45 degrees). Postoperatively the average tibio-femoral alignment was 5 degrees (range 2 degrees to 7 degrees) of valgus. No patient in the study was revised. Conclusion. Adequate lateral soft tissue release is the key to successful TKA in valgus knees. The choice of implant depends on the severity of the valgus deformity and the extent of soft tissue release needed to obtain a stable knee with balanced flexion and extension gaps. The most minimal constraint needed to achieve stability and balance was used in this study. In our experience the long term results of TKR on severe valgus deformities using minimal constrained knee have been good


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 21 - 21
1 Mar 2017
Domb B Suarez-Ahedo C Gui C Martin T Chandrasekaran S Lodhia P
Full Access

Purposes. To compare the acetabular component size relative to the patient's native femoral head size between conventional THA (CTHA) approach and robotic-guided THA (RGTHA) to infer which of these techniques preserves more acetabular bone. Methods. Patients were included if they had primary osteoarthritis (OA) and underwent total hip replacement between June 2008 and March 2014. Patients were excluded if they had missing or rotated postoperative anteroposterior radiographs. RGTHA patients were matched to a control group of CTHA patients, in terms of pre-operative native femoral head size, age, gender, body mass index (BMI) and approach. Acetabular cup size relative to femoral head size was used as a surrogate for amount of bone resected. We compared the groups according to two measures describing acetabular cup diameter (c) in relation to femoral head diameter (f): (1) c-f, the difference between cup diameter and femoral head diameter and (2) (c-f)/f, the same difference as a fraction of femoral head diameter. Results. 57 matched pairs were included in each group. There were no significant differences between groups for demographic measures, femoral head diameter, or acetabular cup diameter (p>0.05). However, measures (1) and (2) did differ significantly between the groups, with lower values in the RGTHA group (p<0.02). Conclusion. Using acetabular cup size relative to femoral head size as an approximate surrogate measure of acetabular bone resection may suggest greater preservation of bone stock using RGTHA compared to CTHA. Further studies are needed to validate the relationship between acetabular cup size and bone loss in THA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 114 - 114
1 Jan 2016
Yoon S Heo I Lee J Park M
Full Access

Background. BHA is popular surgery for femoral neck fractures expecially elderly patients. However, clinical results are variable that factors affecting results are questionable. Therefore we investigated radiologic fators, dysplastic hip whether influences results of BHA. Methods. Between 2004 and 2009, 200 patients undergoing bipolar hemiarthroplasty for femoral neck fracture were divided two groups; a lateral center edge (LCE) angle of < 16 degree or > 16 degree on anteroposterior radiographs. All surgical procedures were performed by a single surgeon. Dermogrpahic data, the harris hip score, WOMAC index, Koval activity level, and complication were recorded. The minimum follow up interval was 4 years (mean, 7.8 years). Result. Late postoperative complications such as periprosthetic joint infection, acetabular erosion, and subluxation of bioplar head were commonly observed in a group <16 degree of center edge angle. Clinical score was significantly lower in dysplastic group. Revision rate was higher in dysplastic group compared with group LCE angle of above the 16 degree. Conclusion. These results suggest that the dysplastic nature might be affected result of bipolar hemiarthroplasty in femroal neck fracture especially elderly patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 77 - 77
1 Apr 2018
Su E Khan I Gaillard M Gross T
Full Access

INTRODUCTION. Childhood diseases involving the proximal femoral epiphysis often cause abnormalities that can lead to end-stage arthritis at a relatively young age and the need for total hip arthroplasty (THA). The young age of these patients makes hip resurfacing arthroplasty (HRA) an alternative and favorable option due to the ability to preserve femoral bone. Patients presenting with end-stage hip arthritis as sequelae of childhood diseases such as Legg-Calves-Perthes (LCP) and slipped capital femoral epiphysis (SCFE) pose altered femoral anatomy, making HRA more technically complicated. LCP patients can result in coxa magna, coxa plana and coxa breva causing altered femoral head-to-neck ratio. There can also be acetabular dysplasia along with the proximal femoral abnormalities. SCFE patients have altered femoral head alignment. In particular, the femoral head is rotated medially and posteriorly, reducing the anterior and lateral offset. Additionally, many of these patients have retained hardware, making resurfacing more complicated. We report findings of a cohort of patients, with history of either LCP or SCPE who underwent HRA to treat end-stage arthritis. METHODS. Data was retrospectively collected for patients who had HRA for hip arthritis as a result of either LCP (n=67) or SCFE (n=21) between 2004 and 2014 performed by two surgeons. Demographic information, clinical examination and improvement was collected pre and postoperatively. Improvement was determined using Harris Hip Scores (HHS) and UCLA activity scores. Anteroposterior radiographs were measured pre and postoperatively to determine leg length discrepancy. Radiographs were inspected postoperatively for radiolucent lines, implant loosening and osteolysis. Kaplan-Meier survivorship for freedom from reoperation for any reason was calculated. Paired student t-tests were used to compare groups. RESULTS. The average age at the time of surgery was 44 years (11.8–68), with an average follow-up of 3.7 years (.22–11.2). Retained hardware was present in a total of 5 patients, 1 LCP and 4 SCFE. Preoperative HHS was 58.3 (33–83), which increased significantly to 94.9 (55–100) at the most recent postoperative timepoint (p<.0001). The most recent UCLA activity score was 7 (1–10). Average leg length discrepancy preoperatively was 7.5mm (0–20), which significantly improved to 0.6mm (0–7.5) postoperatively (p<.0001). At most recent follow-up, metal ion testing revealed median chromium level of 2.3 parts per billion (ppb, 1–7.7) and median cobalt level of 1.5 (0–9.2). There were three failures in the group with 1 LCP due to instability at 2.7 years, and 2 SCFE due to femoral neck fracture at 1 month in one and clinical failure due to unexplained pain at 5.5 years in one. Revision surgery was done in 2 patients, 1 LCP and 1 SCFE. Radiographic examination of all non-failure HRA patients revealed implants to be in good alignment with no indication of implant loosening at the most recent postoperative timepoint. Kaplan-Meier survivorship for freedom from revision was 96.2 at 5 years. CONCLUSION. The findings demonstrated increase in functional outcomes in patients who underwent HRA for osteoarthritis associated with LCP and SCFE. There was no increase in complications including femoral neck fracture or implant loosening despite technical challenges of the procedure