Tendinopathy is a debilitating musculoskeletal
condition which can cause significant pain and lead to complete rupture
of the tendon, which often requires surgical repair. Due in part
to the large spectrum of tendon pathologies, these disorders continue
to be a clinical challenge.
Aim. Treatment of infected and non-infected non-unions remain a major challenge after orthopedic fracture-related surgery. In clinical practice, several revision surgeries are usually required, including a radical debridement and exchange of implants, to control or even eradicate the infection to finally achieve bone healing. However, a clear treatment algorithm in clinical practice may be difficult to follow due to the heterogeneous patient population. Thus, so controlled settings for research purposes is better achieved in standardized animal studies. So far, there exists no multi-stage
The Masquelet or induced membrane technique (IMT) is a two-stage surgical procedure used for the treatment of segmental bone defects. In this technique, the defect is first filled with a polymethyl methacrylate (PMMA) spacer, which triggers the formation of a membrane that will encapsulate the defect. During the second surgery, the spacer is carefully removed and replaced by autologous bone graft while preserving the membrane. This membrane is vascularized, contains growth factors, and provides mechanical stability to the graft, all of which are assumed to prevent graft resorption and promote bone healing. The technique is gaining in popularity and several variations have been introduced in the clinical practice. For instance, orthopaedic surgeons now often include antibiotics in the spacer to treat or prevent infection. However, the consequences of this approach on the properties of the induce membrane are not fully understood. Accordingly, in a small
Aim. A gentamicin-eluting biocomposite consisting of hydroxyapatite and calcium sulfate. 1. can provide effective dead space management in chronic osteomyelitis. However, radiographic follow-up after implantation of this novel material has consistently shown evidence of several unique imaging features previously not described with other comparable bone graft substitutes. Conclusive interpretation of these newly described imaging features is difficult as long term follow-up and histological correlation is not yet available. The aim of this study was to establish a large
Aim. A gentamicin-eluting biocomposite consisting of hydroxyapatite (HA) and calcium sulphate (CaS)*1 can provide effective dead space management and bone formation in chronic osteomyelitis. However, radiographic follow-up after implantation of this biomaterial has shown imaging features previously not described with other comparable bone graft substitutes. Last year we presented preliminary results with a follow-up of 6 months. Now we present the radiographic, µCT and histological one-year follow-up of the critical-size bone defect model in sheep. The aim of this study was to simulate the clinical situation in a large
Aim. Implant-associated osteomyelitis is a devastating complication with poor outcomes following treatment, especially when caused by antibiotic-resistant bacteria such as methicillin-resistant Staphylococcus aureus (MRSA). A large
Nucleus pulposus (NP) replacements represent a less invasive alternative for treatment of early stage degenerative disc disease (DDD). Hydrogel based NP replacements are of particular interest as they can be injected/implanted using minimally invasive surgical (MIS) techniques to re-establish mechanical integrity and as a scaffold for regeneration. A thiol-modified hyaluronan elastin-like polypeptide (TMHA/EP) hydrogel crosslinked using polyethylene diacrylate has shown promise as a potential NP replacement for DDD in vitro. This study aims to assess the mechanical properties of this hydrogel when injected into an induced early stage DDD porcine model and to determine the optimal injection method for delivery. It is hypothesized that minimally invasive injection of the TMHA/EP material can restore mechanical behaviour of spinal motion segments in early stage DDD. Intervertebral disc (IVD) degeneration was enzymatically induced in L2-L3 and L4-L5 lumbar levels in 10 Yorkshire boars using chondroitinase ABC (n=20 discs). An additional three animals served as healthy controls (n=6 discs). Following a four-week degradation period, the TMHA/EP solution (250microL in a 3:1 weight ratio) was injected into the degenerate NP of 16 discs by one of two MIS techniques: A direct 18G needle injection or a modified kyphoplasty technique (MKT) in which a balloon angiocatheter was inserted through an 11G trocar into the IVD and inflated to create a cavitary defect that was then filled with the hydrogel. Excised motion segments were tested in axial compression under a load of 400N and in axial rotation (AR), lateral bending (LB) and flexion/extension (FE) at 5Nm. Range of motion (ROM), neutral zone (NZ) length, NZ stiffness (NZStiff) and axial compressive stiffness (ACStiff) were quantified.Purpose
Method
Ten percent of fractures end in delayed or non-union. NSAIDs have been linked to an inhibitory action on fracture repair for three decades yet the mechanism of action remains to be elucidated. Cancer research has identified that NSAIDs impede cell proliferation by inhibiting angiogenesis. It is proposed that a similar mechanism occurs in the induction of NSAID induced non-union. We have investigated this hypothesis in a randomised placebo control trial of the NSAID rofecoxib using a murine femoral fracture. All animals had an open femoral fracture treated using an external fixator. Outcomes measures included x-ray, histology and biomechanical testing, with laser Doppler used to assess blood flow across the fracture gap. Radiology showed similar healing patterns in both groups; however, at the later stages (day 32) the NSAID group had significantly poorer healing. Histological analysis showed that controls healed quicker (days 24 and 32), with more callus (day 8) and less fibrous tissue (Day 32). Biomechanical testing showed controls were stronger at day 32. Both groups exhibited a similar pattern of blood flow; however NSAIDs exhibited a lower median flow from day 4 onwards (significant at days 4, 16 and 24). Positive correlations were demonstrated between both histological and radiographic assessments of healing, with increasing blood flow. NSAID animals exhibited lower flows and poorer healing by all outcomes. Regression analysis demonstrates, however, that the negative effect of NSAIDs on fracture repair is independent of its inhibitory action on blood flow. COX-2 inhibitors are marketed as having cleaner side effect profiles and are widely used in trauma patients. Following development of a novel method of analysing functional vascularity across a fracture gap, we have demonstrated that the COX-2 inhibitor rofecoxib has a significant negative effect on blood flow at the fracture gap alongside inhibiting fracture repair.
In patients with conventional metal-on-Polyethylene (MoP) hip replacements, osteolysis can occur in response to wear debris. During revision hip surgery, surgeons usually remove the source of osteolysis (polyethylene) but cannot always remove all of the inflammatory granulomatous tissues in the joint. We used a human/rat xenograft model to evaluate the effects of polyethylene granuloma tissues on bone healing. Human osteoarthritic and periprosthetic tissues collected during primary and revision hip arthroplasty surgeries were transplanted into the distal femora of athymic (nude) rats. The tissues were assessed before and after implantation and the bone response to the tissues was evaluated after 1 week and 3 weeks using micro-computed tomography, histology, and immunohistochemistry. After 3 weeks, the majority (70%) of defects filled with osteoarthritic tissues healed, while only 21% of defects with polyethylene granuloma tissues healed. Polyethylene granuloma tissues in trabecular bone defects inhibited bone healing. Surgeons should remove polyethylene granuloma tissues during revision surgery when possible, since these tissues may slow bone healing around a newly implanted prosthesis. This model provides a method for delivering clinically relevant sized particles into an
There are concerns with regard to the physiological effects of reamed intramedullary femoral fracture stabilisation in patients who have received a pulmonary injury. This large animal study used invasive monitoring techniques to obtain sensitive cardiopulmonary measurements and compared the responses to Early Total Care (reamed intramedullary femoral fracture fixation) to Damage Control Orthopaedics (external fixation), after the induction of acute lung injury. We hypothesised a greater cardiopulmonary response to intramedullary fracture fixation. Acute lung injury (PaO2/FiO2 < 200 mmHg) was induced in 12 invasively monitored and terminally anaesthetised male sheep via the infusion of oleic acid into the right atrium. Each animal underwent surgical femoral osteotomy and fixation with either reamed intramedullary (n=6) or external fixation (n=6). Simultaneous haemodynamic and arterial blood-gas measurements were recorded at baseline and at 5, 30 and 60 minutes after fracture stabilisation.Purpose
Method
Introduction. Major trauma during military conflicts involve heavily contaminated open fractures. Staphylococcus aureus (S. aureus) commonly causes infection within a protective biofilm. Lactoferrin (Lf), a natural milk glycoprotein, chelates iron and releases bacteria from biofilms, complimenting antibiotics. This research developed a periprosthetic biofilm infection model in rodents to test an Lf based lavage/sustained local release formulation embedded in Stimulin beads. Method. Surgery was performed on adult rats and received systemic Flucloxacillin (Flu). The craniomedial tibia was exposed, drilled, then inoculated with S. aureus biofilm. A metal pin was placed within the medullary cavity and treatments conducted. Lf in lavage solutions: The defect was subject to 2× 50 mL lavage with 4 treatment groups (saline only, Lf only, Bactisure with Lf, Bactisure with saline). Lf embedded in Stimulin beads: 4 bead types were introduced (Stimulin only, Lf only, Flu only, Lf with Flu). At day 7, rats are processed for bioluminescent and X-ray imaging, and tibial explants/pins collected for bacterial enumeration (CFU). Results. Rats without treatments established a mean infection of 2×106 CFU/tibia. 4 treatment groups with a day 0, one-off lavage demonstrated >95% reduction in bacterial load 7 days post-op, with a reduction in CFU from 1×106/tibia down to 1×104/tibia. There was no statistically significant difference between each group (p = 0.55 with one way ANOVA). The stimulin bead experiments are ongoing and complete results will be obtained in the end of July. Conclusions. This research demonstrated a clinically relevant
Prosthetic joint infection (PJI) is a complex disease that causes significant damage to the peri-implant tissue. Developing an
Aim. To provide proof of concept in an in vivo
Aim. Debridement, Antibiotics, Irrigation, and implant Retention (DAIR) is a surgical treatment protocol suitable for some patients with fracture related infection (FRI). Clinically relevant pre-clinical models of DAIR are scarce and none have been developed in large animals. Therefore, this project aimed to develop a large
Aim. To conduct a systematic review of non-rodent
No
Gram-negative prosthetic joint infections (GN-PJI) present unique challenges in management due to their distinct pathogenesis of biofilm formation on implant surfaces. To date, there are no
Restoration a joint's articular surface following degenerative or traumatic pathology to the osteochondral unit pose a significant challenge. Recent advances have shown the utility of collagen-based scaffolds in the regeneration of osteochondral tissue. To provide these collagen scaffolds with the appropriate superstructure novel techniques in 3D printing have been investigated. This study investigates the use of polyɛ-caprolactone (PCL) collagen scaffolds in a porcine cadaveric model to establish the stability of the biomaterial once implanted. This study was performed in a porcine cadaveric knee model. 8mm defects were created in the medial femoral trochlea and repaired with a PCL collagen scaffold. Scaffolds were secured by one of three designs; Press Fit (PF), Press Fit with Rings (PFR), Press Fit with Fibrin Glue (PFFG). Mobilisation was simulated by mounting the pig legs on a continuous passive motion (CPM) machine for either 50 or 500 cycles. Biomechanical tensile testing was performed to examine the force required to displace the scaffold. 18 legs were used (6 PF, 6 PFR, 6 PFFG). Fixation remained intact in 17 of the cohort (94%). None of the PF or PFFG scaffolds displaced after CPM cycling. Mean peak forces required to displace the scaffold were highest in the PFFG group (3.173 Newtons, Standard deviation = 1.392N). The lowest peak forces were observed in the PFR group (0.871N, SD = 0.412N), while mean peak force observed in the PF group was 2.436N (SD = 0.768). There was a significant difference between PFFG and PFR (p = 0.005). There was no statistical significance in the relationship between the other groups. PCL reinforcement of collagen scaffolds provide an innovative solution for improving stiffness of the construct, allowing easier handling for the surgeon. Increasing the stiffness of the scaffold also allows press fit solutions for reliable fixation. Press fit PCL collagen scaffolds with and without fibrin glue provide dependable stability. Tensile testing provides an objective analysis of scaffold fixation. Further investigation of PCL collagen scaffolds in a live
Surgical reattachment of torn rotator cuff tendons can lead to satisfactory clinical outcome but failures remain common. Ortho-R product is a freeze-dried formulation of chitosan (CS) that is solubilized in platelet-rich plasma (PRP) to form injectable implants. The purpose of the current pilot study was to determine Ortho-R implant acute residency, test safety of different implant doses, and assess efficacy over standard of care in a sheep model. The infraspinatus tendon (ISP) was detached and immediately repaired in 22 skeletally mature ewes. Repair was done with four suture anchors in a suture bridge configuration (n = 6 controls). Freeze-dried formulations containing 1% w/v chitosan (number average molar mass 35 kDa and degree of deacetylation 83%) with 1% w/v trehalose (as lyoprotectant) and 42.2 mM calcium chloride (as clot activator) were solubilized with autologous leukocyte-rich PRP and injected at the tendon-bone interface and on top of the repaired site (n = 6 with a 1 mL dose and n = 6 with a 2 mL dose). Acute implant residency was assessed histologically at 1 day (n = 2 with a 1 mL dose and n = 2 with a 2 mL dose). Outcome measures included MRI assessment at baseline, 6 weeks and 12 weeks, histopathology at 12 weeks and clinical pathology. MRI images and histological slides were scored by 2 blinded readers (veterinarian and human radiologist, and veterinarian pathologist) and averaged. The Generalized Linear Model task (SAS Enterprise Guide 7.1 and SAS 9.4) was used to compare the different groups with post-hoc analysis to test for pairwise differences. Ortho-R implants were detected near the enthesis, near the top of the anchors holes and at the surface of ISP tendon and muscle at 1 day. Numerous polymorphonuclear cells were recruited to the implant in the case of ISP tendon and muscle. On MRI, all repair sites were hyperintense compared to normal tendon at 6 weeks and only 1 out 18 repair sites was isointense at 12 weeks. The tendon repair site gap seen on MRI, which is the length of the hyperintense region between the greater tuberosity and tendon with normal signal intensity, was decreased by treatment with the 2 mL dose when compared to control at 12 weeks (p = 0.01). Histologically, none of the repair sites were structurally normal. A trend of improved structural organization of the tendon (p = 0.06) and improved structural appearance of the enthesis (p = 0.1) with 2 mL dose treatment compared to control was seen at 12 weeks. There was no treatment-specific effect on all standard safety outcome measures, which suggests high safety. Ortho-R implants (2 mL dose) modulated the rotator cuff healing processes in this large
Bone non-union following fracture is a major cause of morbidity in combat casualties. The various clinical treatments used to prevent or treat non-union remain of limited efficacy. Research therefore continues in pre-clinical