Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 34 - 34
1 Dec 2022
Sheridan G Garbuz D MacDonell T Neufeld M Howard L Beverland D Masri B
Full Access

The benefit of using acetabular screws in primary total hip arthroplasty (THA) has been questioned in recent years. The disadvantages of using screws include increased operative time, risk of injury to surrounding neurovascular structures and metal ware breakage. Recent large registry studies have reported that screws do not confer a protective effect against acetabular loosening or the presence of osteolysis. Other studies have even described an increased risk of aseptic acetabular loosening with the selective use of screws. We report findings from a multicentre cohort study. This large cohort study compared clinical outcomes between primary acetabular components that were inserted with and without screws. Independent variables included the presence (or absence) of screws, the total number of screws used and the cumulative screw length (CSL). Outcome measures included all-cause revision, acetabular component revision and acetabular component loosening. Statistical software (Stata/IC 13.1 for Mac [64-bit Intel]) was used to conduct all statistical analyses. A p-value < 0 .05 taken to be significant. There were 4,583 THAs performed in total. Screws were used in 15.9% (n=733). At a mean follow-up of 5.2 years, the all-cause revision rate in the screw cohort was 1.5% compared to 0.83% in the no screw cohort (p=0.085). There was no difference in acetabular component revision rates for screws (3/733, 0.41%) versus no screws (12/3,850, 0.31%) (p=0.439). The rate of acetabular loosening noted during the time of revision surgery was significantly higher when screws were used in the index procedure (2/733, 0.2%) compared to the no screw cohort (1/3,850, 0.02%) (p=0.017). There was no difference in outcomes when stratifying by the number of screws used or the cumulative screw length. Primary acetabular components do not require screws for fixation. All cause revision rates and acetabular component revision rates are comparable for the screw and the no screw cohorts. The rate of acetabular component loosening, as observed during revision surgery, is significantly higher when screws are used in the index total hip replacement


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 42 - 42
1 Feb 2015
McCarthy J
Full Access

The purpose of this study is to evaluate the indications and technique of hip arthroscopy for problems associated with total joint replacement. Materials and Methods:. Fifteen consecutive patients underwent arthroscopy post total hip replacement. Two cases had suspected sepsis unproven by aspiration but for medical reasons were unable to undergo arthrotomy. Two cases had intraarticular migration of a broken trochanteric wire and an additional case had progressive loosening of an acetabular screw into the articulation. The remaining 10 cases had persistent and debilitating pain despite negative diagnostic studies (aspiration, arthrogram, CT, etc). Results:. Two cases of joint sepsis were lavaged and debrided arthroscopically in addition to intravenous antibiotics without recurrent sepsis at 2-year follow up. Intraarticular metal fragments and a loose acetabular screw were successfully removed via arthroscopic means in 3 different hips. Ten cases had hip arthroscopy for persistent and debilitating pain despite negative radiographs and aspiration arthrogram. Findings included a loose acetabular component; corrosion at the interface of a metal-on-metal articulation; and 8 had dense scar tissue impingement at the head cup interface and synovitis. Four of those 8 had complete resolution of their symptoms, 3 went on to open arthrotomy, and one has had some improvement and chooses to decline further surgery. Discussion:. Arthroscopy is not a substitute for open hip debridement and/or resection arthroplasty. However, it is of value in difficult cases to improve diagnostic accuracy. This study demonstrates successful removal of wire, beads and a bone screw by arthroscopic means, thus reducing hospital costs and patient morbidity


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 94 - 94
1 Apr 2019
Peterson M Najmabadi Y Robinson R
Full Access

INTRODUCTION. Additive manufacturing (3D printing) is used to create porous surfaces that promote bone ingrowth in an effort to improve initial stability and optimize long-term biological fixation. The acetabular cup that was studied is manufactured with titanium alloy powder via electron beam melting. Electron beam melting integrates the porous and solid substrate rather than sintering a porous coating to a solid surface. The 3D-printed acetabular cup's high surface coefficient of friction (up to 1.2), combined with its geometry, creates a predictable press-fit in the acetabulum, improving initial mechanical stability and ultimately leading to reproducible biologic fixation. The objective of this study was to evaluate the early clinical outcomes and implant fixation of this 3D-printed acetabular cup in total hip arthroplasty (THA). METHODS. Four hundred twenty-eight subjects from 8 US and international research sites underwent primary THA with the 3D-printed acetabular cup. All sites received IRB approval prior to conducting the study, and all participants signed the informed consent. Screw usage and number used during surgery were used as a surrogate measurement for initial implant fixation. Clinical performance outcomes included pre- and post-operative Harris Hip Scores (HHS) and Oxford Hip Scores (OHS), patient satisfaction, and revision assessment. 215 patients had a minimum 1-year post-operative follow-up visit. Student t-tests were used to identify significant mean differences (p<0.05). RESULTS. Acetabular screws were used in 206 of 428 cases (48.1%); 85.9% used 1 screw, 12.6% used 2 screws, and 1.5% used 3 screws. For patients with a 1-year post-operative visit, the HHS improved by 49.8 points to 91.9 from 42.1, and the OHS improved by 27.7 points to 44.4 from16.7. Patient satisfaction scores at the 1-year post-operative visit were 9.7±0.7 (n=94). There was no significant difference between genders with regard to BMI, the 1-year post-operative HHS, OHS, or patient satisfaction scores. However, the males were significantly younger (59.8 vs. 62.9 years) and had significantly higher pre-operative HHS (45.7 vs. 37.9) and OHS scores (17.8 vs. 15.3). There were 9 revisions reported. DISCUSSION. For initial implant fixation, compared to a similar, non-3D-printed acetabular cup in the same product line, the 3D-printed cup used significantly fewer screws per case (n=1 for 85.9% cases vs. n=2 for 85.7% of cases) in a fewer percentage of cases (48.1% vs. 70.4%), suggesting greater initial stability and “scratch fit”. The 3D-printed acetabular cup also displayed positive early clinical results as evidenced by the pronounced improvement in clinical outcome scores from the pre-operative visit to the 1-year post-operative visit. These 1-year improvements are better than moderate clinically important improvements reported in the literature (40.1 points for HHS). Patient satisfaction scores were also excellent (9.7/10). There were nine revisions; however, four of these were due to patient falls and one was due to infection. SIGNIFICANCE. The 3D-printed acetabular cup evaluated in this study demonstrated improved implant fixation and positive early clinical outcomes for THA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 39 - 39
1 Apr 2017
Hozack W
Full Access

Traditional risk factors for post-operative neuropathy include learning curve of surgical approach, DDH, and significant leg lengthening (>1 inch). Despite these risk factors, the most common scenario of a neuropathy is in a routine THA, by an experienced surgeon, for osteoarthritis, with no leg lengthening. Post-operative hematoma can lead to nerve compression, albeit rarely. The usual clinical presentation is of an acute event, with a previously intact nerve, sometime within the first days of surgery. Once diagnosed, immediate surgical decompression should be performed. Sciatic neuropathy is the most common, regardless of surgical approach, but the posterior approach poses the highest risk. Routine gluteus maximus tendon release may help to reduce the risk. When seen in the PACU, our approach is to immediately perform CT imaging to evaluate nerve integrity or to check on acetabular screw position. If no underlying cause is identified, the patient will be managed conservatively with foot orthotics and monitored for recovery. Femoral nerve palsy (FNP) can result in significant initial disability. Fortunately most patients recover function (although it can take over 18 months). In the early post-operative period it is often diagnosed after a patient complains of the leg giving away while attempting to walk. A knee brace will assist the patient with mobilization while the nerve recovers. The highest incidence of FNP is described for the direct lateral approach. Superior gluteal nerve (SGN) palsy is related to the direct lateral approach and may be avoided if the gluteus medius split is made within the safe zone (<5 centimeters from the tip of the greater trochanter). While early post-operative limp is common after the direct lateral approach, the true reported incidence of SGN palsy is low. Few studies showed that the persistent positive Trendelenburg test and limp is not exclusively related to the SGN damage and therefore the clinical effect of the SGN damage remains controversial. Lateral femoral cutaneous nerve can be affected during the direct anterior hip approach. One study suggests the presence of peri-incisional numbness in over 80% of patients. This is akin to numbness seen lateral to the incision after TKA. The incidence of meralgia paresthetica is extremely low (<1%)


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 2 - 2
1 Feb 2020
Turgeon T Burnell C Hedden D Gascoyne T Bohm E
Full Access

Introduction. Total hip arthroplasty (THA) is a highly successful procedure achieving excellent clinical outcomes beyond 10 years post-surgery. With exception of periprosthetic infection, dislocation is the most common cause of failure in THA. A novel reverse total hip (RTH) replacement has been developed to address dislocation through reversal of the typical THA articulation in which a femoral cup and acetabular ball interlock at the extremes of motion to enhance mechanical stability in all planes. The purpose of this study was to assess the safety and efficacy of this novel RTH in a series of 22 patients and to monitor implant fixation using radiostereometric analysis (RSA). Methods. Twenty two patients with end-stage osteoarthritis of the hip were enrolled between 2017 and 2019 at a single center. All surgeries were performed by a group of four high-volume fellowship-trained arthroplasty surgeons. All patients received at least 1 acetabular cup screw and RSA markers inserted into the acetabulum and proximal femur. Follow-up time points were 6 weeks, 6, 12 and 24 months and included patient reported outcome measures (HOOS, Oxford-12, Harris Hip Score, SF-36 and Satisfaction) as well as RSA assessment. Results. The patient cohort consisted of 11 females and 11 males with mean age of 70.8 years and body mass index 31.3 kg/m. 2. At the time of writing, 21, 15 and 3 patients had completed their 6-month, 1- and 2-year clinical follow-ups, respectively. There was a significant improvement in function and pain with the RTH between pre-operative and six and twelve month follow up as collected by the HOOS, Oxfrod-12, HHS, WOMAC, EQ-5D and SF-36 PCS with p<0.001 for all. The sole exception was the SF-36 MCS which had a non-statistical improvement. Eighteen of 20 patients were satisfied or very satisfied with the outcome of surgery. Average vertical migration of the acetabular cup at 6 and 12 months was 0.082 mm and 0.110 mm, respectively. Average distal migration of the femoral stem at 6 and 12 months was 0.015 mm and 0.035 mm, respectively. Conclusions. Early results indicate acceptable safety and efficacy of this novel RTH for treating osteoarthritis of the hip. The femoral and acetabular components both appear well fixed at near-term follow-up, as assessed with RSA. Further follow-up will determine if these results are maintained at 24 months post-surgery. Additional patient enrollment will assess acetabular cup fixation without the use of screws. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 48 - 48
1 May 2013
McCarthy J
Full Access

Unexplained pain after hip arthroplasty is frustrating for patients and surgeons. The purpose of this study was 1. to describe the use of hip arthroscopy in management of the painful hip arthroplasty, 2. to critically evaluate the outcomes these patients, and 3. to help define indications for hip arthroscopy in this setting. We retrospectively reviewed 14 patients (16 hips) who underwent hip arthroscopy after joint replacement. One patient had suspected septic arthritis despite negative aspiration and one had known septic arthritis but was not a candidate for open arthrotomy; two had intra-articular migration of hardware. The remaining 10 patients (11 hips) had persistent pain despite negative diagnostic studies. The two patients (two hips) with infection were successfully treated with arthroscopic lavage and debridement plus intravenous antibiotics. Intra-articular metal fragments and a loose acetabular screw were successfully removed in two patients (three hips). Findings in remaining the 11 hips included a loose acetabular component (one); corrosion at the head-neck junction of a metal-on-metal articulation (one); soft tissue-scar impingement at the head cup interface (four); synovitis with associated scar tissue (four); and capsular scarring with adhesions (one). Arthroscopy represented a successful treatment or directly led to a successful treatment in 12 of 16 hips. We observed no complications as a result of the arthroscopy. Arthroscopy may be of value in selected patients