The benefit of using
The purpose of this study is to evaluate the indications and technique of hip arthroscopy for problems associated with total joint replacement. Materials and Methods:. Fifteen consecutive patients underwent arthroscopy post total hip replacement. Two cases had suspected sepsis unproven by aspiration but for medical reasons were unable to undergo arthrotomy. Two cases had intraarticular migration of a broken trochanteric wire and an additional case had progressive loosening of an
INTRODUCTION. Additive manufacturing (3D printing) is used to create porous surfaces that promote bone ingrowth in an effort to improve initial stability and optimize long-term biological fixation. The acetabular cup that was studied is manufactured with titanium alloy powder via electron beam melting. Electron beam melting integrates the porous and solid substrate rather than sintering a porous coating to a solid surface. The 3D-printed acetabular cup's high surface coefficient of friction (up to 1.2), combined with its geometry, creates a predictable press-fit in the acetabulum, improving initial mechanical stability and ultimately leading to reproducible biologic fixation. The objective of this study was to evaluate the early clinical outcomes and implant fixation of this 3D-printed acetabular cup in total hip arthroplasty (THA). METHODS. Four hundred twenty-eight subjects from 8 US and international research sites underwent primary THA with the 3D-printed acetabular cup. All sites received IRB approval prior to conducting the study, and all participants signed the informed consent. Screw usage and number used during surgery were used as a surrogate measurement for initial implant fixation. Clinical performance outcomes included pre- and post-operative Harris Hip Scores (HHS) and Oxford Hip Scores (OHS), patient satisfaction, and revision assessment. 215 patients had a minimum 1-year post-operative follow-up visit. Student t-tests were used to identify significant mean differences (p<0.05). RESULTS.
Traditional risk factors for post-operative neuropathy include learning curve of surgical approach, DDH, and significant leg lengthening (>1 inch). Despite these risk factors, the most common scenario of a neuropathy is in a routine THA, by an experienced surgeon, for osteoarthritis, with no leg lengthening. Post-operative hematoma can lead to nerve compression, albeit rarely. The usual clinical presentation is of an acute event, with a previously intact nerve, sometime within the first days of surgery. Once diagnosed, immediate surgical decompression should be performed. Sciatic neuropathy is the most common, regardless of surgical approach, but the posterior approach poses the highest risk. Routine gluteus maximus tendon release may help to reduce the risk. When seen in the PACU, our approach is to immediately perform CT imaging to evaluate nerve integrity or to check on
Introduction. Total hip arthroplasty (THA) is a highly successful procedure achieving excellent clinical outcomes beyond 10 years post-surgery. With exception of periprosthetic infection, dislocation is the most common cause of failure in THA. A novel reverse total hip (RTH) replacement has been developed to address dislocation through reversal of the typical THA articulation in which a femoral cup and acetabular ball interlock at the extremes of motion to enhance mechanical stability in all planes. The purpose of this study was to assess the safety and efficacy of this novel RTH in a series of 22 patients and to monitor implant fixation using radiostereometric analysis (RSA). Methods. Twenty two patients with end-stage osteoarthritis of the hip were enrolled between 2017 and 2019 at a single center. All surgeries were performed by a group of four high-volume fellowship-trained arthroplasty surgeons. All patients received at least 1
Unexplained pain after hip arthroplasty is frustrating for patients and surgeons. The purpose of this study was 1. to describe the use of hip arthroscopy in management of the painful hip arthroplasty, 2. to critically evaluate the outcomes these patients, and 3. to help define indications for hip arthroscopy in this setting. We retrospectively reviewed 14 patients (16 hips) who underwent hip arthroscopy after joint replacement. One patient had suspected septic arthritis despite negative aspiration and one had known septic arthritis but was not a candidate for open arthrotomy; two had intra-articular migration of hardware. The remaining 10 patients (11 hips) had persistent pain despite negative diagnostic studies. The two patients (two hips) with infection were successfully treated with arthroscopic lavage and debridement plus intravenous antibiotics. Intra-articular metal fragments and a loose