Advertisement for orthosearch.org.uk
Results 1 - 20 of 220
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 23 - 23
1 May 2014
Murphy S
Full Access

Ceramic-on-ceramic (COC) bearing surfaces have consistently demonstrated reliable clinical results with when coupled with appropriated designed femoral stems and acetabular shells. Ceramic bearing surfaces are highly wettable and display both boundary and hydrodynamic fluid-film lubrication modes, which lead to extremely low wear rates. Furthermore, COC bearing couples have been shown to exhibit virtually no risk of adverse biologic reaction and have not been associated with corrosion-induced adverse tissue reactions that occur with metal taper junctions, particularly head-neck taper junctions. The relative brittleness of ceramics initially was thought to be a major disadvantage; however, four decades of improvement in the manufacture of ceramics and rigorous proof testing has led an extremely low risk of fracture, perhaps lower than that for cross-linked polyethylene. More recently it has become increasing appreciated that nearly all revisions for squeaking have been restricted to specific designs and materials, including the use of a titanium elevated metal rim on the acetabular side, and more flexible femoral components made of a beta-titanium alloy (TMZF) which had thin necks and relative small tapers. Multiple clinical studies document excellent long-term survival of COC bearing couples in young patients with revision for any reason as the primary endpoint. Our own experience with 341 hips with 2 to 15 and average 9.1 year f/u demonstrates a 95% overall survivorship (revision for any reason) at 13 years in patients under 50 years of age at the time of surgery. By contrast, cross-linked polyethylene bearings have not been studied so carefully and have not been shown to be superior to ceramic-ceramic bearings in young patients. These bearing surfaces represent a very heterogeneous group of products, with varying degrees of cross-linking, post-irradiation processing methods, and additives. Cross-linked polyethylenes in general have a lower fatigue strength than conventional polyethylene and are prone to fracture, especially when thin material is subjected to high stress. Some types of cross-linked polyethylenes are prone to in vivo oxidation, leading to further mechanical compromise over time. Studies also demonstrate the absence of reduction in femoral head penetration or risk of osteolysis in heads 32mm and larger, which are commonly used today. The most recent cross-linked polyethylene products have the least clinical support for their use. The long-term biologic effects of the smaller HXLPE wear particles and newer additives, including the more recently added vitamin E compounds are unknown. Indeed, in vitro, the debris has been shown to be cytotoxic. There is a paucity of survivorship data for hips utilising HXLPE, especially in younger, more active individuals. For these reasons, we believe that the ceramic-ceramic bearings are the gold standard for THA in the young patient and that cross-linked polyethylene bearing are being continually changed and have little long term clinical outcomes data to support their use


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 89 - 89
1 Sep 2012
Shetty V Kasture S
Full Access

The most appropriate bearings in young patients remain highly debated. The aim of this metaanalysis was to summaries the best available evidence on relative success of the three most popular bearings [metal-on-poly (MOP), metal-on-metal (MOM) and ceramic-on-ceramic (COC)] used in total hip replacement (THR) in young active patients. All the relevant studies published in the English language were retrieved. Studies with THR in patients with mean age less than 55 years of age were selected. The survivorship analysis for the three important bearings at 10 years was evaluated. Ten-year survival rates suggest that MOM bearings performed significantly better than MOP (p=0.01) and COC (p=0.001). MOP revealed higher survival rates than COC bearings (p=0.05). Our findings support the use of MOM bearings in the management of the young arthritic hip. These findings, largely based upon observational studies should be taken in context to the limitations of such non-randomized study designs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 438 - 438
1 Dec 2013
Muh S Streit J Wanner JP Shishani Y Nowinski R Gobezie R
Full Access

Introduction. The treatment of glenohumeral arthritis in a young patient poses a significant challenge. Factors that affect decision making include higher activity levels, greater expectations, and concerns of implant longevity. Conflicting results have been reported in the literature. The purpose of this study is to report on our results for resurfacing of the humeral head combined with a biologic glenoid resurfacing using a soft tissue allograft for the treatment of glenohumeral osteoarthritis. Methods. From 2003 to 2009 a retrospective multi-center review of 15 humeral and biologic glenoid resurfacing procedures with a mean age of 36.5 yrs. was performed. Indications for surgery included a diagnosis of glenohumeral arthritis non-responsive to conservative treatment. Exclusion criteria included major glenoid osseous deficiency, advanced rheumatoid arthritis, and chronic infection. Results. Mean follow-up of 57.1 months showed that on average active forward elevation improved from 126.8° to 136° and external rotation improved from 27.1° to 35.3°. The mean pre-operative and post-operative VAS score only improved from 7.9 to 5.1. Five (29%) patients were converted a total shoulder arthroplasty (TSA) at an average of 24 months with no complications in the remaining patients. Discussion. The clinical outcome of humeral head resurfacing with soft tissue resurfacing of the glenoid has not yielded encouraging results, as both pain and function are not significantly improved. Due to the disappointing results of this procedure and high revision rate, it is no longer these authors primary treatment option for OA in the young. Determining the optimal treatment for osteoarthritis in the young patient is still being investigated


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 24 - 24
1 May 2014
Padgett D
Full Access

Due to issues related to osteolysis which became increasingly evident in the 1990's, approaches to combat wear focused upon either improving ultra-high molecular grade polyethylene or to abandon it and employ alternative bearings: metal upon metal or ceramic upon ceramic (COC). Ceramics have played a role in hip bearings for decades with much of the experience coming from Europe. While there is consistent evidence of low wear rates in this bearing couple due to its surface hardness, wettability and resultant low friction, problems unique to this bearing couple were noted: a small but real incidence of fracture, surface damage due to metal transfer and stripe wear as well as the unique issue of squeaking. What we have learned is that these hard bearings (either COC or Metal on Metal) despite being able to use larger diameter heads, are exquisitely sensitive to component position and orientation. With the tremendous improvements in 2nd and now 3rd generation crosslinked polyethylenes demonstrating vastly reduced wear rates and having none of the issues of fracture, stripe wear, or squeaking, it remains unclear what role ceramic bearings have in modern use. Until the aforementioned issues are resolved, ceramic on ceramic bearings in the young patient should be used with caution. Ceramic-on-ceramic total hip arthroplasty: incidence of instability and noise


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 6 - 6
1 May 2012
Golhar A Dawe E Mounsey E Hockings M
Full Access

Introduction. The management of young patients with painful medial compartment osteoarthritis remains controversial. Opening wedge medial high-tibial osteotomy using a locking plate has shown good results in selected patients. This cohort of patients has high physical demands and previous studies have warned against operating on patients with increased body mass index (BMI). Patients and Methods. Thirty five patients undergoing valgus high tibial osteotomy between Oct 2004 and Feb 2010. Surgical outcome was assessed using Oxford Knee score, pre- and post-operative pain scores, change in employment and patient satisfaction. Results. Mean age at the time of surgery was 41 (22 to 62), mean BMI was 30.9 (21 to 43) and mean Oxford score was 37/48 (16 to 48). Patients rated their overall satisfaction as 7.9/10. Three patients were lost to follow-up, two patients died of unrelated disease. Fifteen (50%) patients had heavy manual jobs and of these 12 (80%) returned to their previous employment post-operatively within 6 months. Seven patients had a BMI > 35 (Mean 39) with a mean weight of 126 Kg (105Kg to 144Kg). These patients had a mean Oxford Score of 42/48 and overall satisfaction of 90%. Pain improved from 8.4/10 pre-op to 1.5/10 post-op (P < 0.0001). None had further procedures. Conclusion. Opening wedge high-tibial osteotomy offers a successful alternative treatment of medial osteoarthritis in young patients with high BMI who place high demands on their knees


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 19 - 19
1 May 2012
A. M M. F S. H
Full Access

Aims. To discover how the management of traumatic anterior shoulder dislocation in the young patient (17-25) has changed, if at all, over the past six years. Methods. The same postal questionnaire was sent in 2002 and 2009 to 164 shoulder surgeons. Questions were asked about initial reduction, investigation undertaken, timing of surgery, preferred stabilisation procedure, period of immobilisation and rehabilitation programme instigated in first-time and recurrent traumatic dislocators. Summary of Results. Response rate - 92% (2009), 83% (2002). The most likely management of a young traumatic shoulder dislocation:. Reduction under sedation in A&E by A&E doctor (80%). Apart from X-ray, no investigations are performed (80%). Immobilisation for 3 weeks, followed by physiotherapy (82%). 68% would consider stabilisation surgery for first time dislocators (especially professional sportsmen) compared to 35% (2002). Of them, nearly 90% would perform an arthroscopic stabilisation vs. 57.5% (2002). For recurrent dislocators:. 75% would consider stabilisation after a second dislocation. 85% would investigate prior to surgery, choice of investigation being MR arthrogram (52%), compared to 50% (2002). 77% would perform arthroscopic stabilisation vs. 18% (2002), commonest procedure-arthroscopic Bankart repair using biodegradable bone anchors (62% 2009 vs. 27% in 2002). Immobilisation for 3 weeks, full range of motion 1-2 months and return to contact sports 6 - 12 months. Conclusion. There has been a remarkable change in practice compared to the previous survey. A significant proportion of Orthopaedic Surgeons would consider stabilisation in young first-time dislocators instead of conservative management. Arthroscopic stabilisation is now the preferred technique compared to open stabilisation whenever possible. Surgeons are using more investigations prior to listing the patient for surgery, namely the MR arthrogram. There is also an increased use of bio-degradable anchors as compared to metallic bone anchors in 2002


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 29 - 29
1 May 2014
Parvizi J
Full Access

Developmental dysplasia of the hip (DDH) is relatively a common condition that can lead to early arthritis of the hip. Although total hip arthroplasty is the surgical treatment of choice for these patients with end stage arthritis, some patients afflicted with DDH may present early. Acetabular osteotomy, in particular Bernese or periacetabular osteotomy (PAO as described by Professor Ganz and Jeff Mast back in 1980s) may be an option with patients with symptomatic DDH who have joint space available. PAO has many advantages. First, it is performed through a single incision (modified Smith Peterson approach) without breaching the abductor mechanism. The periacetabular fragment has, hence, excellent blood supply and avascular necrosis of the acetabular portion is not an issue. In addition, the osteotomy is so versatile allowing for great mobility of the fragment to obtain coverage even in the worst of circumstances. The osteotomy does not affect the posterior column and hence allows for earlier weight bearing. Most joint preservation surgeons in North America and Europe prefer PAO to other types of osteotomy.

The indications for PAO are a patient with symptomatic DDH who has good joint space and a congruent joint. The congruency of the joint is usually determined by the abduction views (obtained at 30 degrees abduction and neutral rotation). Although the joint space may be measured on plain radiographs, in recent years some centers have been utilising cross sectional imaging, such as dGEMERIC for evaluation of the articular cartilage, which has been shown to be a good predictor of outcome for PAO.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 143 - 143
1 Feb 2012
Lewthwaite S Squires B Gie G Timperley J Howell J Hubble M Ling R
Full Access

Aim

The aim of this study was to determine the medium term survivorship and function of the Exeter Universal Hip Replacement when used in younger patients, a group that is deemed to place high demands on their arthroplasties. Since 1988 The Exeter Hip Research Unit has prospectively gathered data on all patients who have had total hip replacements at the Princess Elizabeth Orthopaedic Hospital. There were 130 Exeter Universal total hip replacements (THR) in 107 patients who were 50 years or younger at the time of surgery and whose surgery was performed at least 10 years before. Mean age at surgery was 42 years (range 17-50 years.) Six patients who had 7 THRs had died, leaving 123 THRs for review. Patients were reviewed at an average of 12.5 years (range 10-17 years). No patient was lost to follow-up.

Results

At review, 12 hips had been revised. Of these, 9 were for aseptic loosening of the acetabular component and one cup was revised for focal lysis and pain. One hip was revised for recurrent dislocation. One femoral component required revision in 1 case of infection. Radiographs showed that a further 11 (10%) of the remaining acetabular prostheses were loose but that no femoral components were loose. Survivorship of stem and cup from all causes was 94%, at an average of 12.5 years. Survivorship of stem only from all causes was 99% and from aseptic loosening was 100%.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 90 - 90
1 May 2019
Lee G
Full Access

Total hip arthroplasty (THA) is effective, reproducible, and durable in the treatment of hip joint arthritis. While improvements in polyethylene materials have significantly reduced wear rates and osteolysis, aseptic loosening of implants remains one of the leading causes of revision THA. Additionally, fears of dislocation and instability have driven the increase in the utilization of larger diameter femoral heads in primary THA which can lead to increased wear when coupled with a polyethylene articulation. Finally, the increasing number of younger and active patients undergoing THA raises questions with regards to the ability of modern conventional bearings to provide durability and longevity beyond second and third decades following joint implantation. Ceramic-on-ceramic articulations are ideally suited for today's young and high demand patients undergoing primary THA. It has the lowest in-vitro wear properties of any bearing couple and the wear characteristics are further improved by its wettability and lubrication particularly when larger heads are utilised. Additionally, improvements in material properties and prosthesis design have significantly decreased fracture rates and increased the reliability of these implants. Furthermore, reported outcomes and longevity of modern ceramic-on-ceramic THAs in younger patients have all shown excellent survivorship despite patients achieving and maintaining a very high level of activity and function. In short, it is the bearing couple most in tune with current market demands and utilization trends. While registry data and meta-analyses of published literature have failed to show the superiority of ceramic-on-ceramic articulations compared to conventional bearings at 10 years, there is evidence that even highly crosslinked polyethylene (HXPE) is not immune to wear. Selvarajah et al. reported steady, in-vivo wear rates of HXPE exceeding 0.1mm/year threshold in young THA patients with 36mm ceramic ball heads. Additionally, small osteolytic lesions have been observed in hips with HXPE bearings at 12–14 years follow up. Finally, analysis of all controlled randomised studies have shown less osteolysis of ceramic-on-ceramic hips compared to polyethylene articulations. The significance of these lesions are unclear but the question remains: Can HXPE as a bearing be able to provide over 30 years of service needed to outlast patients younger than 60 years?. Concerns with cost, squeaking, and fractures do not make ceramic-on-ceramic bearings suitable for all patients undergoing primary THA. However, in young, healthy and active patients, a modern ceramic- on-ceramic articulation is most likely to provide the lowest wear rates, lowest risk of osteolysis, and greatest chance for life-long durability


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 91 - 91
1 May 2019
MacDonald S
Full Access

At the present time, there is no bearing in total hip arthroplasty that a surgeon can present to a younger and/or more active patient as being the bearing that will necessarily last them a lifetime. This is the driver to offering alternative bearings (crosslinked polyethylene with either a CoCr or ceramic head, resurfacings, and ceramic-on-ceramic) to patients. Each of these bearings has pros and cons, and none has emerged as the clear victor in the ongoing debate.

Ceramic-on-ceramic (CoC) bearings have been available for decades. Earlier generation CoC bearings did encounter problems with rare fractures, however, with a greater understanding and improvement in the material, the fracture incidence has been significantly reduced. However, what has emerged in the past few years is an increasing reporting of significant squeaking. The incidence of squeaking, reported in the literature in various series, has varied from less than 1% to over 20%, depending on the definition used.

The primary reasons that ceramic-on-ceramic is not truly the articulation of choice for younger patients are: 1) There is absolutely no evidence that this bearing has a lower revision rate. Data from the Australian joint registry actually shows that at 15 years it has a significantly increased rate of revision (7.2%) compared with using a highly crosslinked liner with either a ceramic (5.1%) or a CoCr (6.3%) head; 2) This bearing is by far the most costly bearing on the market. In 2017 with significant constraints on health care systems across the globe, this is a significant concern; 3) This bearing has unique complications including squeaking and both liner and head fracturing.

While ceramic-on-ceramic can be considered a viable alternative bearing in total hip arthroplasty, it can be in no way considered the articulation of longevity for the younger patient.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 144 - 144
1 Feb 2012
Pollard T Baker R Eastaugh-Waring S Bannister G
Full Access

Metal-on-metal resurfacing offers an alternative strategy to hip replacement in the young active patient with severe osteoarthritis of the hip. The aim of this study was to compare functional outcomes, failure rates and impending revisions in hybrid total hip arthroplasties (THAs) and Birmingham Hip Resurfacings (BHRs) in young active patients. We compared the 5-7 year clinical and radiological results of the metal-on-metal BHR with hybrid THA in two groups of 54 hips each, matched for sex, age, body mass index and activity. Function was excellent in both groups as measured by the Oxford hip score (median 13 in the BHRs and 14 in the THAs, p=0.14), but the resurfacings had higher UCLA activity scores (median 9 v 7, p=0.001) and better EuroQol quality of life scores (0.90 v 0.78, p=0.003). The THAs had a revision or intention to revise rate of 8% and the BHRs 6%. Both groups demonstrated impending failure on surrogate end-points. 12% of THAs had polyethylene wear and osteolysis under observation, and there was femoral component migration in 8% of resurfacings. Polyethylene wear was present in 48% of hybrid hips without osteolysis. Of the femoral components in the resurfacing group which had not migrated, 66% had radiological changes of unknown significance (classification proposed). In conclusion, the early to mid-term results of resurfacing with the BHR appear at least as good as those of hybrid THA. Only by longer term follow-up will we establish whether the change of practice recorded here represents a true advance


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 4 - 4
1 Jun 2018
Walter W
Full Access

Ceramic-on-ceramic bearings provide a solution to the osteolysis seen with traditional metal-on-polyethylene bearings. Sporadic reports of ceramic breakage and squeaking concern some surgeons and this bearing combination can show in vivo signs of edge loading wear which was not predicted from in vitro studies. Taper damage or debris in the taper between the ceramic and metal may lead to breakage of either a ceramic head or insert. Fastidious surgical technique may help to minimise the risk of ceramic breakage. Squeaking is usually a benign complication, most frequently occurring when the hip is fully flexed. Rarely, it can occur with each step of walking when it can be sufficiently troublesome to require revision surgery. The etiology of squeaking is multifactorial in origin. Taller, heavier and younger patients with higher activity levels are more prone to hips that squeak. Cup version and inclination are also relevant factors.

Osteolysis following metal-on-UHMW polyethylene Total Hip Arthroplasty (THA) is well reported. Earlier generation ceramic-on-ceramic bearings did produce some osteolysis, but in flawed implants. As third and now fourth generation ceramic THAs come into mid- and long-term service, the orthopaedic community has begun to see reports of high survival rates and very low incidence of osteolysis in these bearings. The technique used by radiologists for identifying the nature of lesions on Computed Tomography (CT) scan is the Hounsfield score which will identify the density of the tissue within the lucent area. Commonly the radiologist will have no access to previous imaging, especially pre-operative imaging if a long time has elapsed. With such a low incidence of osteolysis in this patient group, what, then, should a surgeon do on receiving a CT report on a ceramic-on-ceramic THA, which states there is osteolysis? This retrospective review aims to determine the accuracy of CT in identifying true osteolysis in a cohort of long-term third generation ceramic-on-ceramic uncemented hip arthroplasties in our department.

Pelvic CT scans were performed on the first 27 patients from a cohort of 301 patients undergoing 15-year review with third generation alumina-alumina cementless THAs. The average follow-up was 15 years (15–17). The CT scans were reviewed against pre-operative and post-operative radiographs and reviewed by a second musculoskeletal specialist radiologist.

Eleven of the CT scans were reported to show acetabular osteolysis, two reported osteolysis or a possible pre-existing cyst and one reported a definitive pre-existing cyst. After review of previous imaging including pre-operative radiographs, eleven of the thirteen patients initially reported to have osteolysis were found to have pre-existing cysts or geodes in the same size and position as the reported osteolysis, and a further patient had spot-welds with stress-shielding. One patient with evidence of true osteolysis awaits aspiration or biopsy to determine if he has evidence of ceramic wear or metallosis.

Reports of osteolysis on CT should be interpreted with care in modern ceramic-on-ceramic THA to prevent unnecessary revision. Further imaging and investigations may be necessary to exclude other conditions such as geodes, or stress shielding which are frequently confused with osteolysis on CT scans.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 5 - 5
1 Jun 2018
MacDonald S
Full Access

At the present time, there is no bearing in total hip arthroplasty that a surgeon can present to a younger and/or more active patient as being the bearing that will necessarily last them a lifetime. This is the driver to offering alternative bearings (crosslinked polyethylene with either a CoCr or ceramic head, resurfacings, and ceramic-on-ceramic) to patients. Each of these bearings has pros and cons, and none has emerged as the clear victor in the ongoing debate.

Ceramic-on-Ceramic (CoC) bearings have been available for decades. Earlier generation CoC bearings did encounter problems with rare fractures, however, with a greater understanding and improvement in the material, the fracture incidence has been significantly reduced. However, what has emerged in the past few years is an increasing reporting of significant squeaking. The incidence of squeaking, reported in the literature in various series, has varied from less than 1% to over 20%, depending on the definition used.

The primary reasons that Ceramic-on-Ceramic is not truly the articulation of choice for younger patients are:

There is absolutely no evidence that this bearing has a lower revision rate. Data from the Australian joint registry actually shows that at 15 years it has a significantly increased rate of revision (7.2%) compared with using a highly crosslinked liner with either a ceramic (5.1%) or a CoCr (6.3%) head.

This bearing is by far the most costly bearing on the market. In 2017 with significant constraints on health care systems across the globe, this is a significant concern.

This bearing has unique complications including squeaking and both liner and head fracturing.

While Ceramic-on-Ceramic can be considered a viable alternative bearing in total hip arthroplasty, it can be in no way considered the articulation of longevity for the younger patient.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 53 - 53
1 Feb 2012
Wood P
Full Access

Twenty-four replacements were performed in 19 patients (13 female: 6 male), with average age of 33 years (18-40). All had severe polyarticular rheumatoid arthritis. Pre-operatively 12 ankles had no angular deformity, 9 were in valgus and 3 in varus. All had associated hindfoot disease. Some of these patients are part of two larger studies of the Scandinavian Total Ankle Replacement (STAR) and the Buechel-Pappas (BP) replacement. In this group there were 20 STAR and 4 BP replacements. Average follow-up was 62 months (36 to 120). Twenty-one replacements had good pain relief and function. The AOFAS hindfoot score for pain improved from 0 to 36 (max 40) and for function from 25 to 35 (max 60). Three have failed. One ankle had a 25-degree valgus deformity pre-operatively and this recurred and caused failure at 11 months. The second failed at 34 months due to aseptic loosening of the talar component. Both of these were converted to tibio-talo-calcaneal fusions with an intra-medullary nail. The third failure had never provided satisfactory pain relief in spite of appearing satisfactory on clinical and radiological examination. Exploratory surgery was carried out at 36 months but failed to produce an improvement and at 61 months the decision was made to revise the replacement to a fusion. However, due to concurrent health problems, this has not yet been done. We offer replacement to patients with severe polyarticular rheumatoid disease especially if there is a stiff but well aligned hindfoot. In the light of increased experience, we now consider valgus or varus deformity of greater than 20 degrees to be a contra-indication to replacement. This is because the deformity tends to recur leading to pain, loosening and failure.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 31 - 31
23 Feb 2023
Hong N Jones C Hong T
Full Access

Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures are a rare and complex injury. Although some advocate non-operative management, grossly displaced glenoid fossa fractures in the young patient may warrant fixation. Current approaches still describe difficulty with access of the entirety of the glenoid, particularly the postero-superior quadrant. We present 2 cases of Ideberg-Goss type VI/AO F2(4) glenoid fossa fractures treated with fixation through a novel “Deltoid Takedown” approach, which allows safe access to the whole glenoid with satisfactory clinical results at 5 and 7 years respectively


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 47 - 47
1 May 2021
Gigi R Gorrtzak Y Golden E Gabay R Rumack N Yaniv M Dadia S Segev E
Full Access

Introduction. Patient-specific instruments (PSI) and surgical-guiding templates are gaining popularity as a tool for enhancing surgical accuracy in the correction of oblique bone deformities Three-dimensional virtual surgical planning technology has advanced applications in the correction of deformities of long bones and enables the production of 3D stereolithographic models and PSI based upon a patient's specific deformity. We describe the implementation of this technology in young patients who required a corrective osteotomy for a complex three-plane (oblique plane) lower-limb deformity. Materials and Methods. Radiographs and computerized tomographic (CT) scans (0.5 mm slices) were obtained for each patient. The CT images were imported into post-processing software, and virtual 3D models were created by a segmentation process. Femoral and tibial models and cutting guides with locking points were designed according to the deformity correction plan as designed by the surgeon. The models were used for preoperative planning and as an intraoperative guide. All osteotomies were performed with the PSI secured in the planned position. Results. A total of 17 patients (9 males and 8 females, average age 14.7 years [range 8–24]) comprised the study group. All of the PSI were excellent fits for the planned bone surfaces during surgery. The osteotomies matched the preoperative planning simulation and allowed for easy fixation with pre-chosen plates. No intra- or postoperative complications were encountered. Surgery time was shortened (101 minutes) and intraoperative blood loose was less compared to historical cases. Clinical and radiographic follow-up findings showed highly satisfactory alignment of the treated extremities in all 17 patients. Conclusions. The use of 3D-printed models and patient-specific cutting guides with locking points increases accuracy, shortens procedure time, reduces intraoperative blood loss, and improves the outcome of osteotomies in young patients with complex oblique bone deformities


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 25 - 25
1 Apr 2022
Teplentkiy M
Full Access

Introduction. Orthopaedic rehabilitation of adolescences and young adults with high dislocation of the femur is rather challenging. The role of palliative salvage procedures is controversial enough in the cohort of patients. Materials and Methods. Treatment outcomes of 10 patients with congenital hip dislocation were analyzed. Mean age at intervention was 17,8 years (15–22). The grade of dislocation were assessed according to Eftekhar: type C − 2, type D − 8. The mean baseline shortening was 4.7±0.36 cm. All subjects underwent PSO with the Ilizarov method. Another osteotomy for lengthening and realignment was produced at the boundary of the upper and middle third of the femur. The mean time in the Ilizarov frame was 5.3 months. Results. The mean follow-up was 2.6±.1 years (range, 15 to 32 years). Limb shortening of 1 cm to 1. 1. /. 2. cm was observed in four cases. Functional outcomes according to d'Aubigne-Postel were: Pain 4,4±0,15 points. ROM − 4,1±0,3 points. Walking ability − 4,5±0,2 points. Two cases had good results (15–17 points), and seven patients had fair outcomes (12–14 points). A poor result (7 points) was recorded in one female patient 28 years after PSO followed by THA. Conclusions. Hip reconstruction with the Ilizarov method can be used in specific clinical situations as an alternative salvage procedure to delay THR in young patients with high dislocation of the femur


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 11 - 11
1 Jun 2021
Munford M Jeffers J
Full Access

OSSTEC is a pre-spin-out venture at Imperial College London seeking industry feedback on our orthopaedic implants which maintain bone quality in the long term. Existing orthopaedic implants provide successful treatment for knee osteoarthritis, however, they cause loss of bone quality over time, leading to more dangerous and expensive revision surgeries and high implant failure rates in young patients. OSSTEC tibial implants stimulate healthy bone growth allowing simple primary revision surgery which will provide value for all stakeholders. This could allow existing orthopaedics manufacturers to capture high growth in existing and emerging markets while offering hospitals and surgeons a safer revision treatment for patients and a 35% annual saving on lifetime costs. For patients, our implant technology could mean additional years of quality life by revising patients to a primary TKA before full revision surgery. Our implants use patent-filed additive manufacturing technology to restore a healthy mechanical environment in the proximal tibia; stimulating long term bone growth. Proven benefits of this technology include increased bone formation and osseointegration, shown in an animal model, and restoration of native load transfer, shown in a human cadaveric model. This technology could help capture the large annual growth (24%) currently seen in the cementless knee reconstruction market, worth $1.2B. Furthermore, analysis suggests an additional market of currently untreated younger patients exists, worth £0.8B and growing by 18% annually. Making revision surgery and therefore treatment of younger patients easier would enable access to this market. We aim to offer improved patient treatment via B2B sales of implants to existing orthopaedic manufacturer partners, who would then provide them with instrumentation to hospitals and surgeons. Existing implant materials provide good options for patient treatments, however OSSTEC's porous titanium structures offer unique competitive advantages; combining options for modular design, cementless fixation, initial bone fixation and crucially long term bone maintenance. Speaking to surgeons across global markets shows that many surgeons are keen to pursue bone preserving surgeries and the use of porous implants. Furthermore, there is a growing demand to treat young patients (with 25% growth in patients younger than 65 over the past 10 years) and to use cementless knee treatments, where patient volume has doubled in the past 4 years and is following trends in hip treatments. Our team includes engineers and consultant surgeons who have experience developing multiple orthopaedic implants which have treated over 200,000 patients. To date we have raised £175,000 for the research and development of these implants and we hope to gain insight from industry professionals before further development towards our aim to begin trials for regulatory approval in 2026. OSSTEC implants provide a way to stimulate bone growth after surgery to reduce revision risk. We hope this could allow orthopaedic manufactures to explore high growth markets while meaning surgeons can treat younger patients in a cost effective way and add quality years to patients' lives


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 71 - 71
1 Mar 2021
Ibe I Perera J Aoude A Griffin A Wunder J Ferguson P Tsoi K
Full Access

Ewing Sarcoma is the second most common primary bone sarcoma in young patients, however, there remains geographical variation in the treatment of these tumours. All patients receive neoadjuvant chemotherapy and, in most cases, the soft tissue mass diminishes significantly in volume. Controversy surrounds whether to then treat the pre- or post-chemotherapy tumour volume. Many centres advocate either (1) resection of the pre-chemotherapy volume or (2) treatment of the pre-chemotherapy volume with radiation followed by resection of the post-chemotherapy volume. These approaches increase both the short and long-term morbidity for this young patient population. In this study, we retrospectively reviewed our experience resecting only the post-chemotherapy volume without the use of (neo)adjuvant radiotherapy. A retrospective analysis of all patients with Ewing Sarcoma treated at a tertiary orthopaedic oncology centre was conducted. All patients were treated as per the consensus opinion of the multidisciplinary tumour board. Demographic and oncological variables were collected from our institutional database. Presentation and re-staging MRI scans were reviewed to evaluate pre- and post-chemotherapy tumour volumes. Operative and pathology reports were utilized to determine the extent of the surgical resection. Outcome variables included local recurrence free-, metastasis free- and overall survival. Sixty-five patients were identified in our institutional database of which 56 did not receive (neo)adjuvant radiotherapy. Median age at diagnosis was 24 years (range 13–64), 60% of patients were male and 67.6% of tumours were located in the appendicular skeleton. All 56 patients not treated with radiotherapy had resection of the post-chemotherapy tumour volume. There were 3 local recurrences in this group with a mean follow-up of 70.8 months (range 2 to 328). The median overall survival was 47 months and the mean of 70.8months. The rate of local recurrence is comparable to reports in the literature in which patients had their entire pre-chemotherapy tumour volume treated by radiation and/or surgery. Similarly, two-year overall survival for our patient cohort is not significantly different from previous studies in which more aggressive local control measures were employed. Resecting the post-chemotherapy tumour volume in Ewing Sarcoma without the use of (neo)adjuvant radiotherapy does not appear to increase the risk of local recurrence or negatively impact overall survival. This approach should be studied further as it reduces the risk of short and long-term complications for this patient population.”


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_14 | Pages 10 - 10
23 Jul 2024
Al-hasani F Mhadi M
Full Access

Meniscal tears commonly co-occur with ACL tears, and many studies address their side, pattern, and distribution. Few studies assess the patient's short-term functional outcome concerning tear radial and circumferential distribution based on the Cooper et al. classification. Meniscal tears require primary adequate treatment to restore knee function. Our hypothesis is to preserve the meniscal rim as much as possible to maintain the load-bearing capacity of the menisci after meniscectomy. The purpose of this study is to document the location and type of meniscal tears that accompany anterior cruciate ligament (ACL) tears and their effect on patient functional outcomes following arthroscopic ACL reconstruction and meniscectomy. This prospective cross-sectional observational study was conducted at AL-BASRA Teaching Hospital in Iraq between July 2018 and January 2020 among patients with combined ipsilateral ACL injury and meniscal tears. A total of 28 active young male patients, aged 18 to 42 years, were included. All patients were subjected to our questionnaire, full history, systemic and regional examination, laboratory investigations, imaging studies, preoperative rehabilitation, and were followed by Lysholm score 6 months postoperatively. All 28 patients were males, with a mean age of 27 ± 0.14 years. The right knee was the most commonly affected in 20/28 patients (71.4%). The medial meniscus was most commonly injured in 11 patients, 7 patients had lateral meniscal tears, and 10 patients had tears in both menisci. The most common tear pattern of the medial meniscus was a bucket handle tear (36.4%), while longitudinal tears were the most frequent in the lateral meniscus (71.4%) (P-value = 0.04). The most common radial tear location was zone E-F (5/28, 17.8%), and the most common circumferential zone affected was the middle and inner third, reported in 50% of tears. Good and excellent outcomes using the Lysholm score after 6 months were obtained in 42.9% and 17.9% of patients, respectively. Better functional scores were associated with lateral meniscal tears, bucket handle tears, tears extending to a more peripheral vascular area, and if no more than one-third of the meniscus was resected (P-value = 0.002). Less favourable outcomes were reported in smokers, posterior horn tears, and when surgery was delayed more than 1 year (P-value = 0.03). We conclude that there is a negative correlation between the amount of meniscus resected and functional outcome. Delayed ACL reconstruction increases the risk of bimeniscal tears. Bucket handle tears are the most common tears, mostly in the medial meniscus, while longitudinal tears are most common in the lateral meniscus. We recommend performing early ACL reconstruction within 12 months to reduce the risk of bimeniscal injuries