Aims. Deep surgical site infection (SSI) is common after lower limb fracture. We compared the diagnosis of deep SSI using alternative methods of data collection and examined the agreement of clinical photography and in-person clinical assessment by the Centers for Disease Control and Prevention (CDC) criteria after lower limb fracture surgery. Methods. Data from two large, UK-based multicentre randomized controlled major trauma trials investigating SSI and
Aims. To compare the cost-utility of standard dressing with incisional negative-pressure
Aims. The aims of this study were to report the outcomes of patients with a complex fracture of the lower limb in the five years after they took part in the
Aims. To evaluate the impact of negative pressure
Aims. It has been generally accepted that open fractures require early skeletal stabilization and soft-tissue reconstruction. Traditionally, a standard gauze dressing was applied to open
Introduction. Negative pressure
Aims. The aim of this study was to estimate the cost-effectiveness of negative-pressure
Aims. This study sought to compare the rate of deep surgical site infection (SSI), as measured by the Centers for Disease Control and Prevention (CDC) definition, after surgery for a fracture of the hip between patients treated with standard dressings and those treated with incisional negative pressure
Systemic antibiotics reduce infection in open
fractures. Local delivery of antibiotics can provide higher doses
to
Introduction.
Peri-prosthetic
Tranexamic Acid (TA) has been shown to reduce transfusion rates in Total Knee Replacement (TKR) without complication. In our unit it was added to our routine enhanced recovery protocol. No other changes were made to the protocol at this time and as such we sought to examine the effects of TA on
Introduction. Nowadays, autologous platelet-rich plasma is used commonly in
We compared early post-operative rates of wound
infection in HIV-positive and -negative patients presenting with open
tibial fractures managed with surgical fixation. The
Introduction. Over the past decade, the use of negative pressure
Gunshot injuries to the shoulder are rare and
difficult to manage. We present a case series of seven patients
who sustained a severe shoulder injury to the non-dominant side
as a result of a self-inflicted gunshot
There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in
Introduction. Calcium sulphate is a resorbable void filler that can be used for local antibiotic delivery. Results from clinical studies on chronic osteomyelitis thus treated with local vancomycin have already been published. Despite significant exposure to this drug, there are no pharmacokinetic studies published so far. Based on observations in our patients, a model predicting vancomycin serum and
Prospective data on 6905 consecutive hip fracture
patients at a district general hospital were analysed to identify the
risk factors for the development of deep infection post-operatively.
The main outcome measure was infection beneath the fascia lata. A total of 50 patients (0.7%) had deep infection. Operations
by consultants or a specialist hip fracture surgeon had half the
rate of deep infection compared with junior grades (p = 0.01). Increased
duration of anaesthesia was significantly associated with deep infection
(p = 0.01). The method of fracture fixation was also significant. Intracapsular
fractures treated with a hemiarthroplasty had seven times the rate
of deep infection compared with those treated by internal fixation
(p = 0.001). Extracapsular fractures treated with an extramedullary
device had a deep infection rate of 0.78% compared with 0% for those
treated with intramedullary devices (p = 0.02). The management of hip fracture patients by a specialist hip fracture
surgeon using appropriate fixation could significantly reduce the
rate of deep infection and associated morbidity, along with extended
hospitalisation and associated costs.
The Fluid Lavage in Open Fracture Wounds (FLOW) trial was a multicentre,
blinded, randomized controlled trial that used a 2 × 3 factorial
design to evaluate the effect of irrigation solution (soap Participants completed the Short Form-12 (SF-12) and the EuroQol-5
Dimensions (EQ-5D) at baseline (pre-injury recall), at two and six
weeks, and at three, six, nine and 12-months post-fracture. We calculated
the Physical Component Score (PCS) and the Mental Component Score
(MCS) of the SF-12 and the EQ-5D utility score, conducted an analysis
using a multi-level generalized linear model, and compared differences
between the baseline and 12-month scores.Aims
Patients and Methods