We have reviewed the intermediate term results of 56 out of 61 consecutive
Background: It is difficult to achieve a successfull revision total hip arthroplasty when a patient has severe proximal femoral bone loss. From a biomechanical viewpoint, cementless fixation of a tapered stem has some advantages compared with other techniques to treat severe proximal femoral bone loss in reconstructive hip surgery. Methods: We reviewed 129 consecutive revision arthroplasties of the femoral component in which the tapered Wagner self-locking revision stem was used. The indication for revision was aseptic loosening in 97 hips, periprosthetic feacture in 13 (one of which also had an infection), and septic loosening in 16. In the 3 remaining hips, a
Several stems have been used for revision of total hip replacement (THR). Moreover, management of proximal femoral bone loss at the time of revision THR remains one of the challenges for hip surgeons. Recently, impaction bone grafting has been suggested to resolve this problem, but it is a demanding technique that results in frequent complications. We have used the
Revision after failed femoral components may
be technically demanding due to loss of peri-prosthetic bone. This retrospective
study evaluated the long-term results of femoral revision using
the cementless
Failure of the femoral component after a primary or revision THA is commonly associated with some degree of femoral bone loss. Depending on the quantity and quality of the remaining host bone, femoral stem revision can be challenging. Twenty patients with severe proximal femoral bone loss due to prosthetic loosening were treated by Wagner cementless self-locking revision stems with a mean follow up of 24 months (range 18–36 months). The indication of revision surgery was aseptic loosening in 16 patients and septic loosening in 4 cases. At the end of the follow up the mean Harris hip score increased from 35 to 86 points. Definite radiographic evidence of bone regeneration in the bony defects was achieved within 3 months in all patients. Implantation of a Wagner cementless selflocking revision stem provided satisfactory results. The
Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. Methods. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores. Results. Of the 58 patients (62 hips), two (two hips) presented with dislocation or reoperation, and Kaplan-Meier analysis indicated a five-year survival rate of 96.7% (95% CI 92.4 to 100). Mean stem anteversion was 35.2° (SD 18.2°) for the Taperloc stem and 29.8° (SD 7.9°) for the
The femur begins to bow anteriorly at the 200 mm level, but may bow earlier in smaller people. If the stem to be used is less than 200 mm, a straight stem can be used. If the stem is longer than 200 mm, it will perforate the anterior femoral cortex. I know this because I did this on a few occasions more than 20 years ago. To use a long straight stem, there are two techniques. One can either do a diaphyseal osteotomy or one can do a Wagner split (extended trochanteric osteotomy). Both of these will put the knee in some degree of hyperextension, probably insignificant in the elderly, but it may be of significance in the young. In very young people, therefore, it may be preferable to use a bowed stem to avoid this degree of recurvatum. There are two different concepts of loading. Diaphyseal osteotomy implies a proximal loading has been sought. The Wagner split ignores the proximal femur and seeks conical fixation in the diaphysis. There will be very little bone-bone contact between what remains of the attached femur and the detached anterior cortex so that it is important to ensure that the blood supply to the anterior cortex remains intact, preferably by using Wagner's technique, using a quarter-inch osteotome inserted through the vastus to crack the medial cortex. Current modularity is of two types. Distal modularity was attempted many years ago and was never successful. Proximal modularity, as for example, the S-ROM stem, implies various sizes of sleeves fit onto the stem to get a proximal canal fill. In mid-stem modularity, the distal stem wedges into the cone. It has to be driven into where it jams and this can be somewhat unpredictable. For this reason, the solid
The evaluation of the middle term behaviour of the Wagner-type stems in dysplastic femurs and the presentation of the technical and surgical differences with the implantation of a
Aim: The evaluation of the middle term behaviour of the Wagner-type stems in dysplastic femurs and the presentation of the technical and surgical differences with the implantation of a
The aim of this study is the presentation of the results in 48 cases of revision THA with excessive proximal bone loss with the use of the Wagner cementless femoral stem. The bone loss classified with the AAOS system for proximal femoral bone deficiency in type I (17 patients), II (27 patients), and III (4 patients). We used the titanium alloy
Introduction: The
The aim of this study is the comparative assessment of long term clinical (subjective and objective), functional and quality of life outcome data between primary and revision THA. 122 patients (130 hips) who underwent cementless revision THA of both components (TMT cup,
Introduction. There have been increased concerns with trunnion fretting and corrosion and adverse local tissue reactions (ALTR) in total hip arthroplasty. We report on 11 catastrophic trunnion failures associated with severe ALTR requiring urgent revision arthroplasty. Methods. We retrospectively reviewed 10 patients with gross trunnion failure (n=11) and an additional 3 patients with impending trunnion failure. Results. All patients presented to the emergency department with severe pain, an inability to bear weight, and dramatic radiographs demonstrating implant failure. Patients were an average of 7.8 years from the initial index procedure. Implants were a cementless component with metal on polyethylene bearing from a single manufacturer with a 36mm femoral head size and a range of extended offset of 2.5 to 5.5 and neck length of +0 (n=1), +5 (n=5), and +10 (n=5). The implant was used during a limited time (2.5 years) by single surgeon in our practice using a posterior approach, with the last implant placed 7 years ago. Prior to revision, serum cobalt levels were elevated, typically more than chromium levels. Radiographs demonstrated failure of the implant with a dissociation of the head from the taper and large radiolucent fluid collections from the metal debris (Fig 1). Intraoperative findings and magnetic resonance imaging confirmed a diagnosis of ALTR with loss of abductors, and severe material loss from the taper (Fig 2). We estimate a conservative incidence of catastrophic trunnion failure in our series to be 2.2% (n = 636 total implanted). A femoral revision with a modular
To report mid-term results of PJI treated with uncemented stems. : 80 hips of PJI after THA were treated with uncemented stems from 01/1993 to 12/2012 and followed prospectively. Selection occurred for one- (n=27) or two-stage (n=53) exchange according to the Liestal algorithm. Surgical approaches were transfemoral (n=58), transgluteal (n=9) or transtrochanteric (n=13). A monoblock (Wagner SL, n=58) or modular (Revitan, n=22) revision stem was implanted. On the acetabular side 44 Müller rings, 33 Burch-Schneider cages (combined with a cemented PE-cup) and 3 press-fit cups were used. Kaplan-Meier survival was calculated for endpoints (a) persistence of infection, (b) septic/aseptic stem loosening. Radiographs were analysed for (a) subsidence, (b) distal stem integration, (c) changes in cortical thickness, (d) proximal femur restoration, (e) radiolucency around stem/cup. Mean FU was 5.2 (2–15) years. PJI was eradicated in 77 of 80 hips (96%). 3 patients (all two-stage) had a treatment failure. 2 were treated successfully with an additional two-stage exchange. In the 3rd patient we were not able to control infection and exarticulation was performed. Furthermore, one stem was revised for aseptic loosening (5 years), 1 for a broken
There is no mathematical relationship between the internal diameter of the femoral metaphysis and diaphysis. Unless an infinite number of monolithic stems are available with variable metaphyseal and diaphyseal diameters, which is not economically possible, even in virgin cases, the surgeon has to decide if the stem is going to fit in the metaphysis or the diaphysis. It is not possible to match both. In revision cases with a hollowed out metaphysis, the situation is much worse. As it is obviously easier to fit the diaphysis, this is what stems such as the AML and
One hundred twenty eight revision hip arthroplasties performed before Dec. 1995 using the Wagner self locking prosthesis were followed for five to ten years. Obviously, the shape of this revision prosthesis complements optimal primary stability; however, one must pay attention not to undersize the stem. Hence, the most significant feature contributing to this self-locking type is the accomplishment of appropriate canal filling when revision with optimum anchorage length of prosthetic component. According to the clinical and radiological data obtained from our midterm results, we confirm the excellent validity of this system for treating the advanced cases of bone resorption for revision. Obviously the classification based on the femoral bone deficiency by the AAOS and DGOT are well documented. Even though we agree with the recent concept of Bourne-Rorabeck that is worthwhile tending to revert to a simple, but practical classification based on the cancellous bone’s quality and the intactness of the cortical tube, we believe that four of Bourne-Rorabeck had better be five in order to be clearer. Furthermore, additional seven various cases series of recent for subsidence of the femoral components were included in this study. We beieve that the only contraindication is conversion from arthrodesis when the patient has long standing history of heavy plate and screws because of undue discrepancy of the stress shielding. Lastly, it is very unusual, however, we describe the operative technique which
The fixation concept of a fluted, conical, tapered grit-blasted titanium stem has been employed successfully in Europe, but the experience in North America with implants of this design is more limited. The most commonly studied stem of this design, the
Introduction and Objectives: Severe proximal femoral defects are a major problem in femoral stem revision surgery. Various surgical techniques have been described that aim to resolve the deficit of bone stock: the Exeter technique or impacted allograft bone, long porous surface distal fitting stems, stems coated with hydroxyapa-tite, and modular stems with metaphyseal fixation. In 1987, Wagner presented a revision technique using a long distal fitting conical stem with excellent proximal bone regeneration. However, the
Evaluation of the anatomical features, details of surgical technique and results of the THA in patients with CDH (type C1 and C2 by G. Hartofilakidis). From 2001 to 2016 years one surgical team performed 683 THA in patients with CDH. We retrospectively studied 561 total hip arthroplasties in 349 patients, follow-up rate was 82.1%, from 12 to 188 months (mean 69.4). The results were evaluated by clinical examination, X-rays analysis, Harris Hip Score. Unilateral high hip dislocation was observed in 175 patients (31.2%), in these cases often have underdeveloped half of the pelvis on the side of the dislocation. Type C1 was observed in 326 cases and type C2 – in 235 cases. Type C1 in comparison with C2 has less leg length discrepancy, developed shape of proximal femur, presence of supraacetabular osteophyte. The mean displacement of femoral head was 47.6 mm (from 29 to 55) for C1 and 63.4 mm (from 41 to 78) for C2. Average offset in C1 was 50.1 mm (37–63) and in C2 − 44.3 mm (34–52). Shortening osteotomy by T. Paavilainen performed in 165 cases (50.6%) with C1 dysplasia and in 235 cases (100%) with C2. The features of surgical technique were small size of the cups with obligatory additional screw fixation of the cup and small offset of the stems. The cup was positioned into the true acetabulum in 99.1% cases of C2 type, for C1 – only 69.0%). The cups size 44 mm were used in 97.3% cases for type C2 and in 78.6% cases for type C1. For shortening osteotomy in 76.3% cases
D. Regis, A. Sandri, I. Bonetti, M. Braggion, P. Bartolozzi. Femoral revision with the