A spine compression fracture is a very common form of fracture in elderly with osteoporosis. Injection of polymethyl methacrylate (PMMA) to fracture sites is a minimally invasive surgical treatment, but PMMA has considerable clinical risks. We develop a novel type thermoplastic injectable bone substitute contains the proprietary composites of synthetic ceramic bone substitute and absorbable thermoplastic polymer. We used thermoplastic biocompatible polymers Polycaproactone (PCL) to encapsulate calcium-based bone substitutes hydroxyapatite (Ca10(PO4)6(OH)2, HA) and tricalcium phosphate (TCP) to form a biodegradable injectable bone composite material. The space occupation ration PCL:HA/TCP is 1:9. After heating process, it can be injected to fracture site by specific instrument and then self-setting to immediate reinforce the vertebral body. The thermoplastic injection bone substitute can obtain good injection properties after being heated by a heater at 90˚C for three minutes, and has good anti-washout property when injected into normal saline at 37˚C. After three minutes, solidification is achieved. Mechanical properties were assessed using the material compression test system and the mechanical support close to the vertebral spongy bone. In vitro cytotoxicity MTT assay (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) was performed and no cell cytotoxicity was observed. In vivo study with three New Zealand rabbits was performed, well bone growth into bone substitute was observed and can maintain good mechanical support after three months implantation. The novel type thermoplastic injection bone substitute can achieve (a) adequate injectability and viscosity without the risk of cement leakage; (b) adequate mechanical strength for immediate reinforcement and prevent adjacent fracture; (c) adequate porosity for new bone ingrowth; (e) biodegradability. It could be developed as a new option for treating
Abstract. Objectives. The principle of osteoporotic
Abstract. Objectives. To evaluate the safety and efficacy of vertebroplasty with short segmented cement augmented pedicle screws fixation for severe osteoporotic
Balloon kyphoplasty (BKP) is a minimally invasive surgical technique used to correct kyphosis and
Multiple myeloma (MM) is a chronic, malignant B-cell disorder, with a less than 50% 5-year survival rate [1]. This disease is responsible for
Calcium phosphate cements (CPC) are used as biocompatible and bioactive bone void fillers. Ideally, the mechanical properties of these cements should match those of the surrounding bone. The knowledge of the real mechanical properties of the material is important in the decision-making process regarding possible use of the CPCs in different anatomical sites. Although it is generally recognized that these cements are stiffer and more brittle than desired, there is a limited amount of data about the possible deformation of this class of material before failure. The focus of this study was to determine these properties of injectable CPCs. Two different types of self-setting CPCs were investigated in this study: i) hydroxyapatite (HA), that historically has been the most widely studied CPC; ii) brushite, that recently has attracted attention due to its faster resorption than that of HA in vivo. Specimens of both cement types were prepared by mixing a powder phase with a liquid phase that were left to harden in phosphate buffered saline at 37°C. Once set, the specimens underwent a quasi-static compressive test to determine the compressive strength, the elastic modulus and the maximum deformation of the two materials. The material testing machine was equipped with a digital image correlation system, which allows accurate measurement of material deformation directly on the specimen surface. Brushite was found to be significantly more stiff (+80%) and resistant (+84%) than HA. Similar findings were found for the energy needed to create a first crack on the specimen surface. However, the first crack appeared on the specimen surface at the same low deformation level (∼0.15%) independently of the type of material tested. Complete failure of both materials occurred, on average, before reaching 0.25%. It has been demonstrated that the compressive behaviour of CPCs depends on their composition and porosity [1]. One of the main reasons for the high strength and stiffness of the brushite studied here was its low porosity (∼12%). However, the maximum deformation is not positively affected by this decrease in porosity. In fact, both materials show the same brittle behaviour, i.e. they undergo comparably little deformation before they break. Under these conditions, increasing the compressive strength may not always be beneficial clinically, e.g. in the treatment of
Introduction. Polymethylmethacrylate(PMMA) bone cement has been used in joint reconstruction surgery and recently introduced for treatment of osteoporotic
Background. Percutaneous vertebroplasty (PVP) is a well established procedure with respect to improved pain and function following
Summary Statement. Prophylactic vertebroplasty treatment of ‘at-risk’ vertebrae may reduce fracture risk, however which areas weaken, thus providing surgical targets? Direct spatial 3D mapping of ReTm overcomes the constraints of 2D histology, and by application may provide insight into specific regional atrophy. Introduction. Insidious bone loss with age makes the skeleton fracture-prone in the rapidly expanding elderly population. Diagnosis of osteoporosis is often made after irreversible damage has occurred. There are over 300,000 new fragility fractures annually in the UK, more than 120,000 of these being
We performed a biomechanical study to compare the augmentation of isolated fractured vertebral bodies using two different bone tamps. Compression fractures were created in 21 vertebral bodies harvested from red deer after determining their initial strength and stiffness, which was then assessed after standardised bipedicular vertebral augmentation using a balloon or an expandable polymer bone tamp. The median strength and stiffness of the balloon bone tamp group was 6.71 kN (