Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 51 - 51
11 Apr 2023
Robarts S Palinkas V Boljanovic D Razmjou H
Full Access

The Severity Scoring System (SSS) is a guide to interpreting findings across clinical, functional, and radiological findings, used by qualified, specially trained physiotherapists in the advanced practice role in order to provide consistency in determining the severity of the patient's condition and need for surgical consultation. The system has been utilized for over 14 years as a part of standardized assessment and management care and was incorporated into virtual care in 2020 following the pandemic restrictions. The present study examined the validity of the modified SSS in virtual care.

Patients who were referred to the Rapid Access Clinic (RAC), were contacted via phone by two experienced advanced practice practitioners (APPs) from May to July 2020, when in-person care was halted due to the pandemic. The virtual interview included taking history, completing self-reported measures for pain and functional ability and reviewing the radiological reports.

A total of 63 patients were interviewed (mean age 68, SD=9), 34 (54%) females. Of 63 patients, 33 (52%) were considered a candidate for total knee arthroplasty (TKA). Men and women were comparable in age, P4 and LEFS scores. The TKA candidates had a significantly higher SSS (p<0.0001) and pain scores (p=0.024). The variability of the total SSS score explained by the functional, clinical and radiological components of the tool were 55%, 48% and 4% respectively, highlighting the more important role of patient's clinical history and disability in the total SSS.

The virtual SSS is a valid tool in directing patients for surgical management when used by highly trained advanced practice physiotherapists. A large component of the SSS is based on clinical data and patient disability and the APP's skillset rather than severity of pathology found on imaging.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 60 - 60
1 Mar 2013
Bakhsh H Ibrahim I Khan W Smitham P Goddard N
Full Access

In recent years, there has been an increase in using self- admistrated questionnaires to accurately assess intervention outcomes in hand surgery to determine the quality of healthcare. This study aims to evaluate whether the Manchester Modified Disabilities of the Arm, Shoulder and Hand (M2DASH) questionnaire is a valid, reliable, responsive, and unbiased outcome measure for Carpal Tunnel syndrome compared to the Disability of Arm, Shoulder, and Hand (DASH) questionnaire, Boston questionnaire (BQ), and Nerve Conduction Studies (NCS). Method. 48 patients with CTS confirmed by NCS completed the M2DASH, original DASH, and the BQ, at least twice at different time intervals. The scores obtained from M2DASH were compared and correlated with the DASH, BQ, and NCS to assess validity, reliability, responsiveness, and bias of the questionnaires. Results. Validity analysis for M2DASH showed strong positive correlations with the Original DASH and BQ. No significant correlation was obtained from correlating with NCS. Reliability testing confirmed that the M2DASH is internally consistent and reproducible outcome. Significant results for responsiveness were noted in BQ symptom severity scale only. There was no age, gender, hand dominance, or side affected bias in all three questionnaires. Conclusions. The M2DASH is a valid, reliable, and unbiased outcome measure for CTS. In terms of responsiveness this study demonstrated that M2DASH & DASH is weak in detecting the clinical change for CTS, except for the BQ. Further assessment of responsiveness specifically for CTS is required in order to implement this questionnaire in clinical practice to accurately obtain results reflecting the patients progression


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 123 - 123
11 Apr 2023
Ghaffari A Rahbek O Lauritsen R Kappel A Rasmussen J Kold S
Full Access

The tendency towards using inertial sensors for remote monitoring of the patients at home is increasing. One of the most important characteristics of the sensors is sampling rate. Higher sampling rate results in higher resolution of the sampled signal and lower amount of noise. However, higher sampling frequency comes with a cost. The main aim of our study was to determine the validity of measurements performed by low sampling frequency (12.5 Hz) accelerometers (SENS) in patients with knee osteoarthritis compared to standard sensor-based motion capture system (Xsens). We also determined the test-retest reliability of SENS accelerometers.

Participants were patients with unilateral knee osteoarthritis. Gait analysis was performed simultaneously by using Xsens and SENS sensors during two repetitions of over-ground walking at a self-selected speed. Gait data from Xsens were used as an input for AnyBody musculoskeletal modeling software to measure the accelerations at the exact location of two defined virtual sensors in the model (VirtualSENS). After preprocessing, the signals from SENS and VirtualSENS were compared in different coordinate axes in time and frequency domains. ICC for SENS data from first and second trials were calculated to assess the repeatability of the measurements.

We included 32 patients (18 females) with median age 70.1[48.1 – 85.4]. Mean height and weight of the patients were 173.2 ± 9.6 cm and 84.2 ± 14.7 kg respectively. The correlation between accelerations in time domain measured by SENS and VirtualSENS in different axes was r = 0.94 in y-axis (anteroposterior), r = 0.91 in x-axis (vertical), r = 0.83 in z-axis (mediolateral), and r = 0.89 for the magnitude vector. In frequency domain, the value and the power of fundamental frequencies (F0) of SENS and VirtualSENS signals demonstrated strong correlation (r = 0.98 and r = 0.99 respectively). The result of test-retest evaluation showed excellent repeatability for acceleration measurement by SENS sensors. ICC was between 0.89 to 0.94 for different coordinate axes.

Low sampling frequency accelerometers can provide valid and reliable measurements especially for home monitoring of the patients, in which handling big data and sensors cost and battery lifetime are among important issues.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 48 - 48
1 Jan 2019
Mengoni M Zapata-Cornelio FY Wijayathunga VN Wilcox RK
Full Access

The clinical uptake of minimally invasive interventions for intervertebral disc, such as nucleus augmentation, is currently hampered by the lack of robust pre-clinical testing methods that can take into account the large variation in the mechanical behaviour of the tissues. Using computational modelling to develop new interventions could be a way to test scenarios accounting for variation. However, such models need to have been validated for relevant mechanical function, e.g. compressive, torsional or flexional stiffness, and local disc deformations.

The aim of this work was to use a novel in-vitro imaging method to assess the validity of computational models of the disc that employed different degrees of sophistication in the anatomical representation of the nucleus.

Bovine caudal bone-disc-bone entities (N=6) were dissected and tested in uniaxial compression in a custom-made rig. Forty glass markers were placed on the surface of each disc. The specimens were scanned both with MRI and micro-CT before and during loading. Specimen-specific computational models were built from CT images to replicate the compression test. The anatomy of the nucleus was represented in three ways: assuming a standard diameter ratio, assuming a cylindrical shape with its volume matching that measured from MRI, and deriving the shape directly from MRI. The three types of models were calibrated for force-displacement. The radial displacement of the glass markers were then compared with their experimental displacement derived from CT images.

For a similar accuracy in modelling overall force-displacement, the mean error on the surface displacement was 35% for standard ratio nucleus, 38% for image-based cylindrical nucleus, and 32% for MRI-based nucleus geometry.

This work shows that, as long as consistency is kept to develop and calibrate image-based computational models, the complexity of the nucleus geometry does not influence the ability of a model to predict surface displacement in the intervertebral disc.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 39 - 39
1 Aug 2013
Lavery J Anthony I Blyth M Jones B
Full Access

To validate the Modified Forgotten Joint Score (MFJS) as a new patient-reported outcome measure (PROM) in hip and knee arthroplasty against the UK's gold standard Oxford Hip and Knee Scores (OHS/OKS).

The original Forgotten Joint Score was created by Behrend et al to assess post-op hip/knee arthroplasty patients. It is a new assessment tool devised to provide a greater discriminatory power, particularly in the well performing patients. It measures an appealing concept; the ability of a patient to forget about their artificial joint in everyday life. The original FJS was a 12-item questionnaire, which we have modified to 10-items to improve reliability and missing data.

Postal questionnaires were sent out to 400 total hip/knee replacement (THR/TKR) patients who were 1–2 years post-op, along with the OHS/OKS and a visual pain analog score. The data collected from the 212 returned questionnaires (53% return rate) was analysed in relation to construct and content validity. A sub-cohort of 77 patients took part in a test-retest repeatability study to assess reliability of the MFJS.

The MFJS proved to have an increased discriminatory power in high-performing patients in comparison to the OHS and OKS, highlighted by its more normal frequency of distribution and reduced ceiling effects in the MFJS. 30.8% of patients (n=131) scored 42–48 (equivalent to 87.5–100 in the MFJS) or more in the OKS compared to just 7.69% in the MFJS TKR patients. The MFJS proved to have an increased test-retest repeatability based upon its intra-class correlation coefficient of 0.968 compared to the Oxford's 0.845.

The MFJS provides a more sensitive tool in the assessment of well performing hip and knee arthroplasties in comparison to the OHS/OKS. The MFJS tests the concept of awareness of a prosthetic joint, rather than pain and function and therefore should be used as adjunct to the OKS/OHS.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 80 - 80
1 Apr 2018
Sugand K van Duren B Wescott R Carrington R Hart A
Full Access

Background

Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure.

Methods

This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The TAD, procedural time, number of radiographs, number of guide-wire retires and cut-out rate (COR) were recorded for each attempt.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 72 - 72
1 May 2012
Pearson R Kurien T Shu K Scammell B
Full Access

Objective

To determine the reliability, reproducibility, variability and validity of the Osteoarthritis Research Society International (OARSI) Osteoarthritis Cartilage Histopathology (OACH) system and Mankin Histopathology – Histochemical Grading System (HHGS) when applied to the characterisation of the osteoarthritic human knee.

Method

Kellgren-Lawrence and Line Drawing Atlas (LDA) radiology scores clinically graded the knees of ten patients undergoing total knee arthroplasty due to osteoarthritis. The tibial plateaux were scored using the Modified Collins (MC) and Société Française d'Arthroscopie (SFA). Three observers, twice scored, using both the OACH and HHGS systems across a single complete medial and lateral tibial plateau transect taken to include the region with the most severe OA lesion. Intra and inter-observer reliability, reproducibility, variability and validity were quantified, and the correlation between the two histopathology scoring systems was calculated.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 36 - 45
1 Jan 2018
Kleinlugtenbelt YV Krol RG Bhandari M Goslings JC Poolman RW Scholtes VAB

Objectives

The patient-rated wrist evaluation (PRWE) and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire are patient-reported outcome measures (PROMs) used for clinical and research purposes. Methodological high-quality clinimetric studies that determine the measurement properties of these PROMs when used in patients with a distal radial fracture are lacking. This study aimed to validate the PRWE and DASH in Dutch patients with a displaced distal radial fracture (DRF).

Methods

The intraclass correlation coefficient (ICC) was used for test-retest reliability, between PROMs completed twice with a two-week interval at six to eight months after DRF. Internal consistency was determined using Cronbach’s α for the dimensions found in the factor analysis. The measurement error was expressed by the smallest detectable change (SDC). A semi-structured interview was conducted between eight and 12 weeks after DRF to assess the content validity.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 70 - 70
17 Apr 2023
Flood M Gette P Cabri J Grimm B
Full Access

For clinical movement analysis, optical marker-based motion capture is the gold standard. With the advancement of AI-driven computer vision, markerless motion capture (MMC) has emerged. Validity against the marker-based standard has only been examined for lightly-dressed subjects as required for marker placement. This pilot study investigates how different clothing affects the measurement of typical gait metrics. Gait tests at self-selected speed (4 km/h) were performed on a treadmill (Motek Grail), captured by 9 cameras (Qualisys Miqus, 720p, f=100Hz) and analyzed by a leading MMC application (Theia, Canada). A healthy subject (female, h=164cm, m=54kg) donned clothes between trials starting from lightly dressed (LD: bicycle tight, short-sleeved shirt), adding a short skirt (SS: hip occlusion) or a midi-skirt (MS: partial knee occlusion) or street wear (SW: jeans covering ankle, long-sleeved blouse), the lattern combined with a short jacket (SWJ) or a long coat (SWC). Gait parameters (mean±SD, t=10s) calculated (left leg, mid-stance) were ankle pronation (AP-M), knee flexion (KF-M), pelvic obliquity (PO-M) and trunk lateral lean (TL-M) representing clinically common metrics, different joints and anatomic planes. Four repetitions of the base style (LD) were compared to states of increased garment coverage using the t-test (Bonferroni correction). For most gait metrics, differences between the light dress (LD) and various clothing styles were absent (p>0.0175), small (< 2SD) or below the minimal clinically important differences (MCID). For instance, KF-M was for LD=10.5°±1.7 versus MD=12.0°±0.5 (p=0.07) despite partial knee cover. AP-M measured for LD=5.2°±0.6 versus SW=4.1°±0.7 (p<0.01) despite ankle cover-up. The difference for KF-M between LD=10.5°±1.7 versus SWL=6.0°±0.9, SW and SWJ (7.6°±1.5, p<0.01) indicates more intra-subject gait variability than clothing effect. This study suggests that typical clothings styles only have a small clinically possibly negligible effect on common gait parameters measured with MMC. Thus, patients may not need to change clothes or be instructed to wear specific garments. In addition to avoiding marker placement, this further increases speed, ease and economy of clinical gait analysis with MMC facilitating high volume or routine application


Bone & Joint Research
Vol. 6, Issue 10 | Pages 590 - 599
1 Oct 2017
Jefferson L Brealey S Handoll H Keding A Kottam L Sbizzera I Rangan A

Objectives

To explore whether orthopaedic surgeons have adopted the Proximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial results routinely into clinical practice.

Methods

A questionnaire was piloted with six orthopaedic surgeons using a ‘think aloud’ process. The final questionnaire contained 29 items and was distributed online to surgeon members of the British Orthopaedic Association and British Elbow and Shoulder Society. Descriptive statistics summarised the sample characteristics and fracture treatment of respondents overall, and grouped them by whether they changed practice based on PROFHER trial findings. Free-text responses were analysed qualitatively for emerging themes using Framework Analysis principles.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 958 - 965
1 Jul 2008
Leong JJH Leff DR Das A Aggarwal R Reilly P Atkinson HDE Emery RJ Darzi AW

The aim of this study was to validate the use of three models of fracture fixation in the assessment of technical skills. We recruited 21 subjects (six experts, seven intermediates, and eight novices) to perform three procedures: application of a dynamic compression plate on a cadaver porcine model, insertion of an unreamed tibial intramedullary nail, and application of a forearm external fixator, both on synthetic bone models. The primary outcome measures were the Objective Structural Assessment of technical skills global rating scale on video recordings of the procedures which were scored by two independent expert observers, and the hand movements of the surgeons which were analysed using the Imperial College Surgical Assessment Device.

The video scores were significantly different for the three groups in all three procedures (p < 0.05), with excellent inter-rater reliability (α = 0.88). The novice and intermediate groups specifically were significantly different in their performance with dynamic compression plate and intramedullary nails (p < 0.05). Movement analysis distinguished between the three groups in the dynamic compression plate model, but a ceiling effect was demonstrated in the intramedullary nail and external fixator procedures, where intermediates and experts performed to comparable standards (p > 0.6). A total of 85% (18 of 21) of the subjects found the dynamic compression model and 57% (12 of 21) found all the models acceptable tools of assessment.

This study has validated a low-cost, high-fidelity porcine dynamic compression plate model using video rating scores for skills assessment and movement analysis. It has also demonstrated that Synbone models for the application of and intramedullary nail and an external fixator are less sensitive and should be improved for further assessment of surgical skills in trauma. The availability of valid objective tools of assessment of surgical skills allows further studies into improving methods of training.