Aims. The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. Methods. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and
Aims. Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome measures (PROMs) are still unclear. Accordingly, we assessed hip survival and PROMs at 20 years after transpositional osteotomy of the acetabulum (TOA). Methods. A total of 172 hips in 159 patients who underwent TOA were followed up at a mean of 21.02 years (16.6 to 24.6) postoperatively. Kaplan-Meier analysis was used to assess survivorship with an endpoint of total hip arthroplasty (THA). PROMs included the visual analogue scale (VAS) Satisfaction,
Aims. The aim of this study was to assess the clinical and radiological results of patients who were revised using a custom-made triflange acetabular component (CTAC) for component loosening and pelvic discontinuity (PD) after previous total hip arthroplasty (THA). Methods. Data were extracted from a single centre prospective database of patients with PD who were treated with a CTAC. Patients were included if they had a follow-up of two years. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance and clinical relevance. Results. A total of 18 females with 22 CTACs who had a mean age of 73.5 years (SD 7.7) were included. A significant improvement was found in HOOS (p < 0.0001), mOHS (p < 0.0001), EQ-5D-3L utility (p = 0.003), EQ-5D-3L NRS (p = 0.013),
Pelvic discontinuity (PD) is a detrimental complication following total hip arthroplasty (THA). The aim of this study was to assess the clinical and radiological results of patients with PD who were revised using a custom-made triflange acetabular component (CTAC). This is a single centre prospective study of patients with PD following THA who were treated with a CTAC. The Hip Disability and Osteoarthritis Outcome Score (HOOS), modified Oxford Hip Score (mOHS), EurQol five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at one- and two-year follow-up. Clinical and radiological complications, including reasons for revisions were registered. Trends over time are described and tested for significance and clinical relevance. 18 females with 22 CTACs were included with a mean age of 73.5 years (SD 7.7). There were significant improvements between baseline and final follow-up in HOOS (p<0.01), mOHS (p<0.01), EQ-5D-3L utility (p<0.01), EQ-5D-3L NRS (p<0.01),
Although periacetabular osteotomies are widely used for the treatment of symptomatic acetabular dysplasia, the surgical outcomes after long term follow-up are still limited. Thus, we assessed hip survival and patient-reported outcomes (PROMs) at 20 years after the transposition osteotomy of acetabulum (TOA). Among 260 hips in 238 patients treated with TOA, 172 hips in 160 patients were evaluated at average 20.8 years, excluding patients who died or lost to follow-up. Kaplan-Meier analysis was used to assess survivorship with an end-point of THA. PROMs were evaluated using the VAS satisfaction,
The objective of this study was to assess the clinical and radiological results of patients who were revised using a new generation custom-made triflange acetabular component (CTAC) for component loosening and large acetabular defect (Paprosky 3A and 3B) after previous total hip arthroplasty (THA). New generation CTACs involve the use of patient-specific drill guides and incorporate three-dimensional printed bone models, enhancing precision during surgical implantation. Data were extracted from a single centre prospective database of patients with large acetabular defects who were treated with a new generation CTAC. Patients were included if they had a minimum follow-up of five years. The modified Oxford Hip Score (mOHS), EurQol EuroQoL five-dimension three-level (EQ-5D-3L) utility, and Numeric Rating Scale (NRS), including visual analogue score (VAS) for pain, were gathered at baseline, and at two- and five-year follow-up. Reasons for revision, and radiological and clinical complications were registered. Trends over time are described and tested for significance (p<0.05). A total of 49 (70%) of 70 patients with a mean age of 73.5 years (SD 7.7) had a complete follow-up of 5 years. A significant improvement was found in HOOS, mOHS, EQ-5D-3L utility and NRS,
We designed a study to evaluate whether (1) there were differences in PROMs between different reasons for revision THA at baseline, (2) there was a different interaction effect for revision THA for all PROMs, and (3) complication and re-revision rates differ between reason for revision THA. Prospective cohort of 647 patients undergoing rTHA, with a minimum of 2 years FU. The reason for revision were classified as infection, aseptic loosening, dislocation, structural failure and painful THA with uncommon causes. PROMs (EQ-5D score, Oxford hip score (OHS),
Introduction. Prosthetic designs that use porous metals possess an extremely high surface area and through capillary effect may potentially ‘absorb’ and later elute analgesic solution, serving as a surgical site drug depot. This study aimed to determine if a highly porous acetabular component submerged in an aqueous-based analgesic solution prior to implantation reduced postoperative pain scores and opioid consumption in the early post-operative period. Methods. Using our IRB approved database, 200 consecutive opioid naïve primary THA patients operated on by a single surgeon at two institutions using the same acetabular component were identified. 100 patients had a standard volume/concentration of an analgesic cocktail soft-tissue injection at closure (control). 100 patients had their acetabular components submerged into the same cocktail prior to implantation (treatment) and the balance of the volume injected. Postoperative protocols were otherwise identical. Groups were compared for
Introduction. Without intervention 80% of hips with osteonecrosis (ON) will progress. Core decompression has shown favorable results (60–80% survivorship) in early stage ON, and recently, bone marrow aspirate concentration (BMAC) injection into the decompressed femoral head has been proposed to stimulate healing of the necrotic lesion and improve outcomes and survivorship. Methods. We retrospectively reviewed the clinical and radiographic outcomes of 42 hips in 26 patients who underwent core decompression with BMAC for ON with a minimum of 1 year follow up. We evaluated pre-op
Background. The acetabular labrum provides sealing function and a degree of hip joint stability. Previous early(16 month) and mid-term(mean 3.5 years) follow-up of this cohort reported better patient related outcome measures in the refixation group. Methods. We reported patients who underwent labral debridement/focal labral excision during a period before the development of labral repair techniques. Patients with labral tears thought to be repairable with our current arthroscopic technique were compared with patients who underwent labral refixation. In 46 hips, the labrum was focally excised/debrided (group 1); in 54 hips, the labrum was refixed (group 2). Outcomes were measured with modified-Harris-Hip-Score (mHHS), Short Form-12 (SF-12), and a visual-analog-scale(VAS) for pain preoperatively and postoperatively. Results. Mean age was 33 years in group 1 and 28 years in group 2 with mean follow-up of 7 years (range, 2–13.6 years). At mean follow-up, subjective outcomes were significantly improved (P<.01) for both groups compared with preoperative scores. The mHHS (P=.005), SF-12 (P=.025), and
Introduction. Total hip arthroplasty (THA) candidates have received high doses of opioids within the perioperative period for the management of surgical pain. Healthcare systems have responded by improving opioid administration documentation and are now implementing opioid-sparing protocols (OSP) into THA integrated care pathways (ICP). Here we evaluate the effectiveness of a novel OSP in primary THA at out institution. Methods. Between January 2019 to April 2019, all patients undergoing primary THA were placed under a novel OSP (Table 1). Patient demographics, inpatient/surgical factors, and inpatient opiate administration events were collected. A historical 2:1 cohort was subsequently derived from patients undergoing THA between January 2018 to August 2018. Opiate administration events collected from our EDW were converted into Morphine Milligram Equivalences (MMEs) and transformed into average MME's per patient per 24-hour interval. Nursing documented visual analog scale (VAS) pain scores were also queried and averaged per patient per 12-hour interval. To assess immediate postoperative functional status, the validated Activity Measure for Post-Acute Care (AM-PAC) Short Forms tool was utilized. Results. 652 primary THAs had received our institution's OSP, and 1357 patients were utilized as our historical control. Age, gender, BMI, ASA physical status score, race, smoking status, marital status, surgical time, length of stay and discharge disposition were all similar between the two groups (Table 2). Compared to historical controls, OSP patients demonstrated significantly lower 24-hour interval opiate consumption at 0–24, 24–48 and 48–72 hours. Though
The aim of this study was to explore the relationship between reason for revision total hip arthroplasty (rTHA) and outcomes in terms of patient-reported outcome measures (PROMs). We reviewed a prospective cohort of 647 patients undergoing full or partial rTHA at a single high-volume centre with a minimum of two years’ follow-up. The reasons for revision were classified as: infection; aseptic loosening; dislocation; structural failure; and painful THA for other reasons. PROMs (modified Oxford Hip Score (mOHS), EuroQol five-dimension three-level health questionnaire (EQ-5D-3L) score, and visual analogue scales for pain during rest and activity), complication rates, and failure rates were compared among the groups.Aims
Methods
Obesity is associated with an increased risk of hip osteoarthritis, resulting in an increased number of total hip arthroplasties (THAs) performed annually. This study examines the peri- and postoperative outcomes of morbidly obese (MO) patients (BMI ≥ 40 kg/m2) compared to healthy weight (HW) patients (BMI 18.5 to < 25 kg/m2) who underwent a THA using the anterior-based muscle-sparing (ABMS) approach. This retrospective cohort study observes peri- and postoperative outcomes of MO and HW patients who underwent a primary, unilateral THA with the ABMS approach. Data from surgeries performed by three surgeons at a single institution was collected from January 2013 to August 2020 and analyzed using Microsoft Excel and Stata 17.0.Aims
Methods
The aims of this study were to validate the Forgotten Joint Score-12 (FJS-12) in the postoperative evaluation of periacetabular osteotomy (PAO), identify factors associated with joint awareness after PAO, and determine the FJS-12 threshold for patient-acceptable symptom state (PASS). Data from 686 patients (882 hips) with hip dysplasia who underwent transposition osteotomy of the acetabulum, a type of PAO, between 1998 and 2019 were reviewed. After screening the study included 442 patients (582 hips; response rate, 78%). Patients who completed a study questionnaire consisting of the visual analogue scale (VAS) for pain and satisfaction, FJS-12, and Hip disability and Osteoarthritis Outcome Score (HOOS) were included. The ceiling effects, internal consistency, convergent validity, and PASS thresholds of FJS-12 were investigated.Aims
Methods
Introduction. Hip abductor tendon tears have been referred to as “rotator cuff tears of the hip,” and are a recognized etiology for persistent, often progressive, lateral hip pain, weakness, and limp. Multiple repair techniques and salvage procedures for abductor tendon tears have been reported in the literature; however, re-tear remains a frequent complication following surgical repair. This study compares the short-term outcomes of open abductor tendon repairs with decortication and suture fixation (DSF) compared to a modified technique repair into a bone trough (BT), to determine best surgical results for large abductor tendon avulsions. Additionally, surgical treatment of small tears versus large tears was examined. Methods. The outcomes of 37 consecutive hip abductor tendon repairs treated between January 2009 and December 2017 were retrospectively reviewed. Large tears were defined as detachment of 33–100% of the gluteus medius insertion. There were 15 DSF and 10 BT cases. Postoperative pain, ability to perform single leg stance, hip abduction, and Trendelenburg lurch, were examined. Small tears (12 cases) were defined as having no gluteus medius avulsion from the trochanteric insertion and were comprised of longitudinal tears (repaired side-by-side) and isolated gluteus minimus tears (repaired by tenodesis to the overlying gluteus medius). Standard statistical analyses were utilized. Type I error for all analyses was set at α=0.05. Results. When comparing large tear repair outcomes, repairs into a BT had superior outcomes to repairs with DSF: 0 (BT) versus 6 (DSF, 40%) failure rate (p<0.05), and greater reductions in pain at one-year post surgery (Δ VAS: BT, −5.70±0.97 | DSF: −2.73±0.69; p<0.01), ability to perform a single leg stance and hip abduction (90% and 100% vs 47% and 73%) (p<0.05). Clinical strength ratings were higher for repairs into a BT, but this did not reach statistical significance. When comparing large to small tear repair outcomes, small tears were found to have lower
The Exeter short stem was designed for patients with Dorr type A femora and short-term results are promising. The aim of this study was to evaluate the minimum five-year stem migration pattern of Exeter short stems in comparison with Exeter standard stems. In this case-control study, 25 patients (22 female) at mean age of 78 years (70 to 89) received cemented Exeter short stem (case group). Cases were selected based on Dorr type A femora and matched first by Dorr type A and then age to a control cohort of 21 patients (11 female) at mean age of 74 years (70 to 89) who received with cemented Exeter standard stems (control group). Preoperatively, all patients had primary hip osteoarthritis and no osteoporosis as confirmed by dual X-ray absorptiometry scanning. Patients were followed with radiostereometry for evaluation of stem migration (primary endpoint), evaluation of cement quality, and Oxford Hip Score. Measurements were taken preoperatively, and at three, 12, and 24 months and a minimum five-year follow-up.Aims
Methods
Hip arthroscopy has gained prominence as a primary surgical intervention for symptomatic femoroacetabular impingement (FAI). This study aimed to identify radiological features, and their combinations, that predict the outcome of hip arthroscopy for FAI. A prognostic cross-sectional cohort study was conducted involving patients from a single centre who underwent hip arthroscopy between January 2013 and April 2021. Radiological metrics measured on conventional radiographs and magnetic resonance arthrography were systematically assessed. The study analyzed the relationship between these metrics and complication rates, revision rates, and patient-reported outcomes.Aims
Methods
Although the Fitmore Hip Stem has been on the market for almost 15 years, it is still not well documented in randomized controlled trials. This study compares the Fitmore stem with the CementLeSs (CLS) in several different clinical and radiological aspects. The hypothesis is that there will be no difference in outcome between stems. In total, 44 patients with bilateral hip osteoarthritis were recruited from the outpatient clinic at a single tertiary orthopaedic centre. The patients were operated with bilateral one-stage total hip arthroplasty. The most painful hip was randomized to either Fitmore or CLS femoral component; the second hip was operated with the femoral component not used on the first side. Patients were evaluated at three and six months and at one, two, and five years postoperatively with patient-reported outcome measures, radiostereometric analysis, dual-energy X-ray absorptiometry, and conventional radiography. A total of 39 patients attended the follow-up visit at two years (primary outcome) and 35 patients at five years. The primary outcome was which hip the patient considered to have the best function at two years.Aims
Methods
The aim of this study was to determine whether total hip arthroplasty (THA) for chronic hip pain due to unilateral primary osteoarthritis (OA) has a beneficial effect on cognitive performance. A prospective cohort study was conducted with 101 patients with end-stage hip OA scheduled for THA (mean age 67.4 years (SD 9.5), 51.5% female (n = 52)). Patients were assessed at baseline as well as after three and months. Primary outcome was cognitive performance measured by d2 Test of Attention at six months, Trail Making Test (TMT), FAS-test, Rivermead Behavioural Memory Test (RBMT; story recall subtest), and Rey-Osterrieth Complex Figure Test (ROCF). The improvement of cognitive performance was analyzed using repeated measures analysis of variance.Aims
Methods
Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component.Aims
Methods