Advertisement for orthosearch.org.uk
Results 1 - 20 of 210
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 56 - 56
7 Nov 2023
Mazibuko T
Full Access

Sacral fractures are often underdiagnosed, but are frequent in the setting of pelvic ring injuries. They are mostly caused by high velocity injuries or they can be pathological in aetiology. We sought to assess the clinical outcomes of the surgically treated unstable sacral fractures, with or without neurological deficits. unstable sacral fractures were included in the study. Single centre, prospectively collected data, retrospective review of patients who sustained vertically unstable fractures of the sacrum who underwent surgical fixation. out of a total of 432 patients with pelvis and acetabulum injuries. fifty six patients met the inclusion criteria. 18 patients had sustained zone one injuries. 14 patients had zone 2 injuries and 10 patients had zone 3 injurie. Operative fixation was performed percutaneously using cannulated screws in 18 patients.. Open fixation of the sacrum using the anterior approach in 6 patients. Posterior approach was indicates in all 10 of the zone 3 injuries of the sacrum. While in 4 patients, combined approaches were used. 3 patients had decompression and spinopelvic fixation. Neurological deficits were present in 16% of the patients. 2 patients presented with neurgenic bladder. Of the 4 patients who had neurological fall out, 3 resolved with posterior decompression and posterior fixation. All 4 neurological deficits were due to taction or compression of the nerve roots. No hardware failures or non unions observed. The rate of neurological deficit was related more to the degree of pelvic ring instability than to a particular fracture pattern. Low rates of complications and successful surgical treatment of sacral fractures is achiavable. Timeous accurate diagnosis mandatory


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 80 - 80
1 Dec 2022
Nauth A Dehghan N Schemitsch C Schemitsch EH Jenkinson R Vicente M McKee MD
Full Access

There has been a substantial increase in the surgical treatment of unstable chest wall injuries recently. While a variety of fixation methods exist, most surgeons have used plate and screw fixation. Rib-specific locking plate systems are available, however evidence supporting their use over less-expensive, conventional plate systems (such as pelvic reconstruction plates) is lacking. We sought to address this by comparing outcomes between locking plates and non-locking plates in a cohort of patients from a prior randomized trial who received surgical stabilization of their unstable chest wall injury. We used data from the surgical group of a previous multi-centred, prospective, randomized controlled trial comparing surgical fixation of acute, unstable chest wall injuries to non-operative management. In this substudy, our primary outcome was hardware-related complications and re-operation. Secondary outcomes included ventilator free days (VFDs) in the first 28 days following injury, length of ICU and hospital stay, and general health outcomes (SF-36 Physical Component Summary (PCS) and Mental Component Summary (MCS) scores). Categorical variables are reported as frequency counts and percentages and the two groups were compared using Fisher's Exact test. Continuous data are reported as median and interquartile range and the two groups were compared using the Wilcoxon rank-sum test. From the original cohort of 207 patients, 108 had been treated surgically and had data available on the type of plate construct used. Fifty-nine patients (55%) had received fixation with non-locking plates (primarily 3.5 or 2.7 mm pelvic reconstruction plates) and 49 (45%) had received fixation with locking plates (primarily rib-specific locking plates). The two groups were similar in regard to baseline and injury characteristics. In the non-locking group, 15% of patients (9/59) had evidence of hardware loosening versus 4% (2/49 patients) in the locking group (p = 0.1). The rate of re-operation for hardware complications was 3% in the non-locking group versus 0% in the locking group (p = 0.5). No patients in either group required revision fixation for loss of reduction or nonunion. There were no differences between the groups with regard to VFDs (26.3 [19.6 – 28] vs. 27.3 [18.3 – 28], p = 0.83), length of ICU stay (6.5 [2.0 – 13.1] vs 4.1 [0 – 11], p = 0.12), length of hospital stay (17 [10 – 32] vs. 17 [10 – 24], p = 0.94) or SF-36 PCS (40.9 [33.6 – 51.0] vs 43.4 [34.1 – 49.6], p = 0.93) or MCS scores (47.8 [36.9 – 57.9] vs 46.9 [40.5 – 57.4], p = 0.95). We found no statistically significant differences in outcomes between patients who received surgical stabilization of their unstable chest wall injury when comparing non-locking plates versus locking plates. However, the rate of hardware loosening was nearly 4 times higher in the non-locking plate group and trended towards statistical significance, although re-operation related to this was less frequent. This finding is not surprising, given the inherent challenges of rib fixation including thin bones, comminution, potential osteopenia and a post-operative environment of constant motion. We believe that the increased cost of locking plate fixation in this setting is likely justifiable given these findings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 113 - 113
10 Feb 2023
Burrows K Lock A Smith Z McChesney S
Full Access

Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and national joint registry data were reviewed for follow up. No significant difference was found in overall failure rate of PFNA vs InterTan (4.84% vs 3.23%; p = 0.748). Overall, short nails were more likely to fail by cut-out than long nails (7.5% vs 1.2%; p = 0.015). Nails which failed by varus cut-out had a higher tip/apex distance (TAD) (26.2mm vs 17.0mm; p < 0.001). Of concern, varus cut-out occurred in two InterTan nails with TAD of <25mm. The PFNA enjoyed a shorter operative time for both the short (59.1 vs 71.8 mins; p = 0.022) and long nails (98.8 vs 114.3 mins; p = 0.016) with no difference in 120-day survival rate. Overall failure rates of the PFNA and InterTan nailing systems were comparable. However, the failure rate of short nails in this study is concerning. Using long nails with a lag screw design for unstable intertrochanteric femoral fractures may reduce failure rates. Cumulative frequency analysis suggests stringent tip-apex distances of less than 21mm may reduce failure rates in lag-screw design cephulomedullary nails. This dataset suggests that unstable intertrochanteric fractures may be more reliably managed with a long cephalomedullary device


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 26 - 26
23 Feb 2023
George JS Norquay M Birke O Gibbons P Little D
Full Access

The risk of AVN is high in Unstable Slipped Capital Femoral Epiphysis (SCFE) and the optimal surgical treatment remains controversial. Our AVN rates in severe, unstable SCFE remained unchanged following the introduction of the Modified Dunn Procedure (MDP) and as a result, our practice evolved towards performing an Anterior Open Reduction and Decompression (AOR) in an attempt to potentially reduce the “second hit” phenomenon that may contribute. The aim of this study was to determine the early surgical outcomes in Unstable SCFE following AOR compared to the MDP. All moderate to severe, Loder unstable SCFEs between 2008 and 2022 undergoing either an AOR or MDP were included. AVN was defined as a non-viable post-operative SPECT-CT scan. Eighteen patients who underwent AOR and 100 who underwent MPD were included. There was no significant difference in severity (mean PSA 64 vs 66 degrees, p = 0.641), or delay to surgery (p = 0.973) between each group. There was no significant difference in the AVN rate at 27.8% compared to 24% in the AOR and MDP groups respectively (p = 0.732). The mean operative time in the AOR group was 24 minutes less, however this was not statistically significant (p = 0.084). The post-reduction PSA was 26 degrees (range, 13–39) in the AOR group and 9 degrees (range, -7 to 29) in the MDP group (p<0.001). Intra-operative femoral head monitoring had a lower positive predictive value in the AOR group (71% compared to 90%). Preliminary results suggest the AVN rate is not significantly different following AOR. There is less of an associated learning curve with the AOR, but as anticipated, a less anatomical reduction was achieved in this group. We still feel that there is a role for the MDP in unstable slips with a larger remodelling component


The purpose of this study was to investigate the effectiveness of casting in achieving acceptable radiological parameters for unstable ankle injuries. This retrospective observational cohort study was conducted involving the retrieval of X-rays of all ankles taken over a 2 year period in an urban setting to investigate the radiological outcomes of cast management for unstable ankle fractures using four acceptable parameters measured on a single X- ray at union. The Picture Archiving and Communication System (PACS) was used, the X-rays were measured by a single observer. From the 1st of January 2020 to the 31st of December 2021, a total of 1043 ankle fractures were treated at the three hospitals with a male to female ratio of 1:1.7. Of the 628 unstable ankle injuries, 19% of patients were lost to follow up. 190 were managed conservatively with casts, requiring an average of 4 manipulations, with a malunion rate of 23.2%. Unstable ankle injuries that were treated surgically from the outset and those who failed conservative management and subsequently converted to surgery had a malunion rate of 8.1% and 11.0% respectively. Unstable ankle fractures pose a challenge with a high rate of radiological malunion, regardless of the treatment Casting surgery from the outset or converted to surgery, with rates of 23% and 8% and 11% respectively. In this multivariate analysis we found that conservative management was the only factor influencing the incidence of malunion, age, sex and type of fracture did not have a scientific significant influence


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 94 - 94
1 May 2016
Ogawa T Takao M Sakai T Nishii T Sugano N
Full Access

Introduction. The incidence of dislocation after total hip arthroplasty (THA) was reported to be 0.5 to 10% in primary THA and 10 to 25 % in revision THA. The main causes of instability after THA were reported to be implant malalignment and inappropriate soft tissue tension. However, there was no study about quantitative data of soft tissue tension of unstable THA. The purpose of this study is to clarify the features of soft tissue tension of unstable THA in comparison to stable THA. Methods. The subjects were 15 patients with 15 THAs who had developed recurrent dislocation after primary THA. Thirty four patients with 37 THAs who developed no dislocation for one year after surgery were recruited as a stable THA group. In both group, all THAs were performed through posterolateral approach. In order to assess the soft tissue tension of THA, we recorded antero-posterior radiographs of the hips while applying distal traction to the leg with traction forces of 20?, 30%, 40% of body weight (BW). The distance of separation of the head and the cup after traction was measured under correction of magnification. Nine of 15 THAs in the unstable THA group and 32 of 37 THAs in the stable THA group were unilateral involvement. In the hips with unilateral involvement, the femoral offset difference between the healthy hip and the reconstructed hip were evaluated. Statistical analysis was performed with χ2 testand Mann-Whitney U test, and statistical significance was set at P<0.05. Results and Discussion. The average separation distance of the head and the cup was 5.2 ± 3.4mm (SD) at 40%BW, 4.3±3.2mm at 30%BW, and 3.2±2.8mm at 20%BW in the unstable THA group. The average separation distance of the head and the cup was 1.4±1.5mm at 40%BW, 1.1±1.4mm at 30%BW, and 0.9±1.2mm at 20%BW in the stable THA group. There were statistically significant differences in the separation distance between the groups in all ranges of traction force. The femoral offset difference between the operated side and the healthy side was −1.2±5.6mm in the unstable THA group and 3.1±4.8mm in the stable THA group. There were no significant difference in the femoral offset difference, however the femoral offset tends to be small in the unstable THA group compared to the stable THA group (P=0.05). The leg length discrepancy was −3.1±11.6mm in the unstable THA group and 2.7±7.1mm in the stable THA group. There were no significant difference in the leg length discrepancy (P=0.12). Conclusion. The separation distance of the head and the cup during leg distal traction in the unstable THA group is about four times larger than that in the stable THA group. The femoral offset tended to be smaller in the unstable THA group compared to the stable THA group


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 58 - 58
1 Mar 2021
Dehghan N Nauth A Schemitsch E Vicente M Jenkinson R Kreder H McKee M
Full Access

Unstable chest wall injuries have high rates of mortality and morbidity. These injuries can lead to respiratory dysfunction, and are associated with high rates of pneumonia, sepsis, prolonged ICU stays, and increased health care costs. Numerous studies have demonstrated improved outcomes with surgical fixation compared to non-operative treatment. However, an adequately powered multi-centre randomized controlled study using modern fixation techniques has been lacking. We present a multi-centred, prospective, randomized controlled trial comparing surgical fixation of acute, unstable chest wall injuries with the current standard of non-operative management. Patients aged 16–85 with a flail chest (3 or more consecutive, segmental, displaced rib fractures), or severe deformity of the chest wall, were recruited from multiple trauma centers across North America. Exclusion criteria included: severe pulmonary contusion, severe head trauma, randomization>72 hours from injury, inability to perform surgical fixation within 96 hours from injury (in those randomized to surgery), fractures of the floating ribs, or fractures adjacent to the spine not amendable to surgical fixation. Patients were seen in follow-up for one year. The primary outcome was days free from mechanical ventilation in the first 28 days following injury. Secondary outcomes were days in ICU, rates of pneumonia, sepsis, need for tracheostomy, mortality, general health outcomes, pulmonary function testing, and other complications of treatment. A sample size of 206 was required to detect a difference of 2 ventilator-free days between the two groups, using a 2-tailed alpha error of 0.05 and a power of 0.80. A total of 207 patients were recruited from 15 sites across Canada and USA, from 2011–2018. Ninety-nine patients were randomized to non-operative treatment, and 108 were randomized to surgical fixation. Overall, the mean age was 53 years, and 75% of patients were male, with 25% females. The commonest mechanisms of injury were: motor vehicle collisions (34%), falls (20%), motorcycle collisions (14%), and pedestrian injuries (11%). The mean injury severity score (ISS) at admission was 26, and patients had a mean of 10 rib fractures. Eighty-nine percent of patients had pneumothorax, 76% had haemothorax, and 54% had pulmonary contusion. There were no differences between the two groups in terms of demographics. The final results will be available and presented at the COA meeting in Halifax. This is the largest randomized controlled trial to date, comparing surgical fixation to non-operative treatment of unstable chest wall and flail chest injuries. The results of this study will shed light on the best treatment options for patients with such injuries, help understand outcomes, and guide treatment. The final results will be available and presented at the COA meeting in Halifax


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 39 - 39
23 Feb 2023
Jo O Almond M Rupasinghe H Jo O Ackland D Ernstbrunner L Ek E
Full Access

Neer Type-IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. A novel plating technique using a superior lateral locking plate with antero-posterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment has been designed to enhance stability. The purpose of this study was to biomechanically compare three different clavicle plating constructs. 24 fresh-frozen cadaveric shoulders were randomised into three groups (n=8 specimens). Group 1: lateral locking plate only (Medartis Aptus Superior Lateral Plate); Group 2: lateral locking plate with CC stabilisation (Nr. 2 FiberWire); and Group 3: lateral locking plate with two AP locking screws stabilising the lateral fragment. Data was analysed for gap formation after cyclic loading, construct stiffness and ultimate load to failure, defined by a marked decrease in the load displacement curve. After 500 cycles, there was no statistically significant difference between the three groups in gap-formation (p = 0.179). Ultimate load to failure was significantly higher in Group 3 compared to Group 1 (286N vs. 167N; p = 0.022), but not to Group 2 (286N vs. 246N; p = 0.604). There were no statistically significant differences in stiffness (Group 1: 504N/mm; Group 2: 564N/mm; Group 3: 512N/mm; p = 0.712). Peri-implant fracture was the primary mode of failure for all three groups, with Group 3 demonstrating the lowest rate of peri-implant fractures (Group 1: 6/8; Group 2: 7/8, Group 3: 4/8; p = 0.243). The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 10 - 10
1 Jan 2016
Song IS Shin SY
Full Access

Background. The aim of this study was to evaluate causes and results of revision surgery in unstable total knee arthroplasties. Methods. We retrospectively reviewed 24 knees that underwent a revision arthroplasty for unstable total knee arthroplasty. The average follow-up period was 33.8 months. We classified the instability and analyzed the treatment according to its cases. Stress radiographs, postoperative component position and joint level were measured. Clinical outcomes were assessed using the score and range of motion of the Hospital for Special Surgery (HSS). Results. Causes of instability included coronal instability with posteromedial polyethylene wear and lateral laxity in 13 knees(Fig. 1) and coronal instability with posteromedial polyethylene wear in 6 knees(Fig. 2), coronal and sagittal instability in 3 knees including post breakage in 1 knee(Fig. 3), global instability in 1 knee(Fig. 4) and flexion instability in 1 knee. Mean preoperative/postoperative varus and valgus angles were 5.8°/3.2° (p = 0.713) and 22.5°/5.6° (p = 0.032). Mean postoperative α, β, γ, δ angle were 5.34°, 89.65°, 2.74°, 6.77°. Mean changes of joint levels were from 14.1 mm to 13.6 mm from fibular head (p = 0.82). The mean HSS score improved from 53.4 to 89.2 (p = 0.04). The average range of motion was changed from 123° to 122° (p = 0.82). Conclusions. Revision total knee arthroplasty with or without a more constrained prosthesis will be a definite solution for an unstable total knee arthroplasty. The solution according to the causes is very important and seems to have a chance of avoidance of unnecessary over-constrained implant selection in revision surgery for total knee instability


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 373 - 373
1 Dec 2013
Song IS Kim TI
Full Access

Background:. To evaluate causes and results of revision arthroplasties in unstable total knee arthroplasties. Methods:. We retrospectively reviewed 24 knees that underwent revision arthroplasty for unstable total knee arthroplasty from December 2004 to December 2010. The mean age was 71.0(range, 54–85) years and the average follow-up period was 33.8 months (range, 6–70). The mean interval between the primary TKA and revision TKA was 82.5 months (range, 14–228). We classified the instability and analyzed the treatment according to its cases. Stress radiographs, postoperative component position and joint level were measured. Joint line position was measured using the fibular head as the reference point. Clinical outcomes were assessed using the Hospital for Special Surgery (HSS) score and range of motion. Wilcoxon sign rank test was employed for statistical analysis, and when p-value was over 0.05, it was analyzed as having statistical significances. Results:. Causes of instability included coronal instability with medial laxity in 13 knees (Fig. 1) and with polyethylene wear in 6 knees, coronal and sagittal instability in 3 knees including post breakage in 1 knee (Fig. 2, Fig. 3), global instability in 1 knee, and flexion instability in 1 knee. Mean preoperative/postoperative varus and valgus angles were 5.8°/3.2°(p = 0.713) and 22.5°/5.6°(p = 0.032). Mean postoperative α, β, γ, δ angle were 5.34°, 89.65°, 2.74°, 6.77°. Mean change of Joint levels were form 14.1 mm to 13.6 mm from fibular head (p = 0.82). The mean HSS score improved from 53.4 to 89.2(p = 0.04). The average range of motion was changed from 123° to 122°(p = 0.82). Conclusions:. Revision total knee arthroplasty with more constrained prosthesis was a very effective. The solution according to the causes is very important in revision surgery for unstable arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 78 - 78
1 Jun 2012
Guyen O Chevillotte C Wegrzyn J Pibarot V Bejui-Hugues J Carret J
Full Access

Introduction. Reoperations to manage unstable total hip arthroplasty are reported with a high failure rate. The dual mobility cup (figure 1) (mobile polyethylene component between the prosthetic head and the outer metal shell) is a useful option in such cases. The purpose of this retrospective study was to assess the clinical and radiologic features associated with the dual mobility cup. Materials and Methods. Fifty one unstable total hip arthroplasties (32 females, 19 males) were revised using a dual mobility socket at our institution between March 2000 and February 2005. Mean age at reoperation was 67 year old (range, 35 to 98). The outcome of the revision procedure was assessed using the Harris Hip Score, and complications were determined by detailed review of the patient's records. Anteroposterior and lateral radiographs of the involved joint were reviewed to assess the position of the prosthesis and to look for osteolysis and signs of loosening of the implant. Results. Mean follow-up was 4 years (range, 2 to 6.7). At last review 4 patients had died and one was lost to follow up. Postoperatively there was a significant improvement of the Harris Hip Score. Fifty patients (98%) had no further episodes of dislocation. There were 3 revisions for deep infection, and 2 for dissociation of the bipolar component. No cup required a revision for aseptic loosening. No radiolucent lines around the components and no osteolysis were observed at latest follow up. Conclusion. The dual mobility cup is a highly effective option to manage unstable total hip arthroplasty. Unlike constrained devices, such components provide encouraging radiologic results regarding the potential for loosening and osteolysis. Longer follow up is needed to confirm these results


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 105 - 105
1 May 2016
Kim J Park B Cho H
Full Access

Purpose. To observe the follow-up results of standard cemented bipolar hemiarthroplasty with double loop and tension band wiring technique for treatment of unstable intertrochanteric hip fractures in elderly patients with osteoporosis. Materials and Methods. From May 2000 to May 2006, 86 cemented bipolar hemiarthroplasties were performed in elderly patients who had unstable intertrochanteric fractures. The mean age at the time of surgery was 82 years old. The average follow-up period were 5.3 years. We evaluated post-operative results after operation by clinical and radiographic methods. Results. Clinically, the final follow-up of Harrsi hip score was noted 79.2. The mean time needed for full weight bearing following surgery was 4.2 weeks and 82.5% of patients regained their preoperative ambulatory level. All patients achieved union in lesser trochanter fracuture, but great trochanter displacement were observed in 4 cases. There was one case of acetabular erosion. Post-operative superficial infections were found in 2 cases. 1 case with stem subsidence(<5 mm) showed satisfactory results without further subsidence in follow-ups. Conclusion. If we properly apply indications in technique with cemented bipolar hemiarthroplasty in the treatment of unstable intertrochanteric hip fracture in elderly, we will achieve systematic postoperative rehabilitation, pain control and handy nursing which is its one of merits


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 143 - 143
1 Mar 2012
Chidambaram R Mok D
Full Access

Introduction. Unstable dorsal fracture/dislocation of PIP joint is a complex injury and difficult to treat. Different treatment methods have been described with varying results. We describe a novel technique to combine fracture fixation with volar plate repair using micro anchor suture. Material and methods. Between July and December 2005, 11 consecutive patients with unstable dorsal PIP joint dislocations underwent open reduction and volar plate repair using our technique. Nine patients had dorsal fracture dislocations and two had open dislocations. All patients were males and their average age was 26 years. All patients were reviewed with the minimum follow up of 12 months. The pain score, range of movements and grip strength were recorded and compared to the normal side. Operative Technique. Volar approach was made using a semi Brunar incision. One or two micro bioabsorbable anchors (Mitek, Ethicon Ltd, UK) were used to stabilise the joint and repair the volar plate. Additional anchor was used to repair the collateral ligament when indicated. Post-operatively the hand was rested in Edinburgh functional splint for 10 days followed by active and assisted range of movements under hand physiotherapist supervision. Results. 10 out 11 patients had excellent pain relief. The average range of movement of the PIP joint was 100 degrees. One patient with neglected PIP joint fracture dislocation for 10 weeks had mild residual pain and stiffness. The mean grip strength was 87% of that of contralateral normal side. All patients returned to their same work as before. 8 out of 9 patients returned to play their regular sports at the same level. All patients were satisfied with the functional outcome. Conclusion. Combined fracture fixation and volar plate repair through anterior approach using micro bioabsorbable anchors appears to be very effective way of treating this otherwise complex unstable fracture/dislocation of PIP joint


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 35 - 35
1 Dec 2016
Napora J Thompson G Gilmore A Son-Hing J Liu R
Full Access

Unstable slipped capital femoral epiphysis (SCFE) has an increased incidence of avascular necrosis (AVN). The purpose of this study was to determine if early identification and intervention for AVN may help preserve the femoral head. We retrospectively reviewed 48 patients (50 hips) with unstable SCFE managed between 2000 and 2014. Based on two different protocols during the same time period, 17 patients (17 hips) had a scheduled MRI between 1 and 6 months from initial surgery, with closed bone graft epiphysiodesis (CBGE) or free vascularised fibular graft (FVFG) if AVN was diagnosed. Thirty-one patients (33 hips) were evaluated by plain radiographs. Outcomes analysed were Steinberg classification and subsequent surgical intervention. We defined Steinberg class IVC as failure in treatment because all of the patients referred for osteotomy, arthoplasty, or arthrodesis in our study were grade IVC or higher. Overall, 13 hips (26%) with unstable SCFE developed AVN. MRI revealed AVN in 7 of 17 hips (41%) at a mean of 2.5 months postoperatively (range, 1.0 to 5.2 months). Six hips diagnosed by MRI received surgical intervention (4 CBGE, 1 FVFG, and 1 repinning due to screw cutout) at a mean of 4.1 months (range, 1.3 to 7.2 months) postoperatively. None of the 4 patients treated with CBGE within two months postoperatively progressed to stage IVC AVN. The two patients treated after four months postoperatively both progressed to stage VC AVN. Radiographically diagnosed AVN occurred in 6 of 33 hips (18%) at a mean of 6.8 months postoperatively (range, 2.1 to 21.1 months). One patient diagnosed with stage IVB AVN at 2.4 months had screw cutout and received CBGE at 2.5 months from initial pinning. The remaining 5 were not offered surgical intervention. Five of the 6 radiographically diagnosed AVN, including the one treated with CBGE, progressed to stage IVC AVN or greater. None of the 4 patients with unstable SCFE treated with CBGE within 2 months post pinning developed grade IVC AVN, while all patients treated with other procedures after 2 months developed IVC or greater AVN. Early detection and treatment of AVN after SCFE may alter the clinical and radiographic progression


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 23 - 23
1 May 2015
Dahill M McArthur J Acharya M Ward A Chesser T
Full Access

Traditionally, unstable anterior pelvic ring injuries have been stabilised with an external fixator or by internal fixation. Recently, a new percutaneous technique of placement of bilateral supraacetabular polyaxial screws and subcutaneous connecting bar to assemble an “internal fixator” has been described. We present the surgical technique and early clinical results of using this technique in twenty-five consecutive patients with a rotationally unstable pelvic ring injury and no diastasis of the symphysis pubis treated between April 2010 and December 2013. Additional posterior pelvic stabilisation with percutaneous iliosacral screws was used in 23 of these patients. The anterior device was routinely removed after three months. Radiological evidence of union of the anterior pelvic ring was seen in 24 of 25 patients at a minimum 6 month follow-up. Thirteen patients developed sensory deficits in the lateral femoral cutaneous nerve (five bilateral) and only one fully recovered. The anterior pelvic internal fixator is a reliable, safe and easy percutaneous technique for the treatment of anterior pelvic ring injuries, facilitating the reduction and stabilisation of rotational displacement. However, lateral femoral cutaneous nerve dysfunction is common. The technique is recommended in cases with bilateral or unilateral pubic rami fractures and no diastasis of the symphysis pubis


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 154 - 154
1 Jan 2013
Bugler K Hardie A Watson C Appleton P McQueen M Court-Brown C White T
Full Access

Techniques for fixation of the lateral malleolus have remained essentially unchanged since the 1960s, but are associated with complication rates of up to 30%. The fibular nail is an alternative method of fixation requiring a minimal incision and tissue dissection, and has the potential to reduce complications. We reviewed the results of 105 patients with unstable fractures of the ankle that were fixed between 2002 and 2010 using the Acumed fibular nail. The mean age of the patients was 64.8 years (22 to 95), and 80 (76%) had significant systemic medical comorbidities. Various different configurations of locking screw were assessed over the study period as experience was gained with the device. Nailing without the use of locking screws gave satisfactory stability in only 66% of cases (4 of 6). Initial locking screw constructs rendered between 91% (10 of 11) and 96% (23 of 24) of ankles stable. Overall, seven patients had loss of fixation of the fracture and there were five post-operative wound infections related to the distal fibula. This lead to the development of the current technique with a screw across the syndesmosis in addition to a distal locking screw. In 21 patients treated with this technique there have been no significant complications and only one superficial wound infection. Good fracture reduction was achieved in all of these patients. The mean physical component Short-Form 12, Olerud and Molander score, and AAOS Foot and Ankle outcome scores at a mean of six years post-injury were 46 (28 to 61), 65 (35 to 100) and 83 (52 to 99), respectively. There have been no cases of fibular nonunion. Nailing of the fibula using our current technique gives good radiological and functional outcomes with minimal complications, and should be considered in the management of patients with an unstable ankle fracture


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 115 - 115
1 Sep 2012
Garg B Kumar V Malhotra R Kotwal P
Full Access

A prospective, randomized, controlled trial was performed to compare the outcome of treatment of unstable fractures of the proximal part of the femur with either a sliding hip screw or a short proximal femoral nail antirotation (PFNA-XS, Synthes). Eighty one patients (April 2007 – May 2008) presenting with unstable fracture of the proximal part of the femur were randomized, at the time of admission, to fixation with use of either a short proximal femoral nail antirotation (n=42) or a sliding hip screw (n= 39). The primary outcome measure was reoperation within the first postoperative year and mortality at the end of one year. Operative time, fluoroscopy time, blood loss, and any intra-operative complication were recorded for each patient. Follow-up was undertaken at 3, 6, and 12 postoperative months and yearly thereafter. Plain AP and lateral radiographs were obtained at all visits. All changes in the position of the implant, complications, or fixation failure were recorded. Hip range of motion, pain about the hip and the thigh, walking ability score and return to work status were used to compare the outcomes. There was no significant difference between 1 year mortality rates for the two groups. Mean Operative time was significantly less in PFNA group (Mean 25 min, range 19 – 56 min) than DHS group (Mean 38 min, range 28 – 70 min). Patients treated with a PFNA experienced a shorter fluoroscopy time and less blood loss. 6 patients in DHS group had implant failure as compared to none in PFNA group. The functional outcome was also better in PFNA group. When compared to DHS, PFNA-XS provides better functional outcome for unstable trochanteric fractures with less operative time, less blood loss and less complications, however one year mortality rate remains the same


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 16 - 16
1 Jan 2016
Guyen O Pibarot V Wegrzyn J Bejui-Hugues J
Full Access

Introduction. Revision procedures for unstable total hip arthroplasty have been reported with high failure rates. Many options have been proposed in such challenging cases, including dual mobility. The purpose of this retrospective study was to assess the clinical and radiologic features associated with the dual mobility cup in case of revisions for instability. Materials and Methods. Sixty four total hip arthroplasties (62 patients) were revised for THA instability using a dual mobility cup at our institution between March 2000 and April 2008. Mean age at reoperation was 67.3 year old (range, 35 to 98). The outcome of the revision procedure was assessed using the Harris Hip Score, and complications were determined by detailed review of the patient's records. Anteroposterior and lateral radiographs of the involved joint were reviewed to assess the position of the prosthesis and to look for osteolysis and signs of loosening of the implant. Results. Mean follow-up was 7.5 years (range, 3.5 to 11.1). At last review 11 patients had died and one was lost to follow up. Postoperatively there was a significant improvement of the Harris Hip Score. Sixty-three patients (98.4%) had no further episodes of dislocation. There were 3 revisions for deep infection, and 4 for mechanical failures including 2 dissociation of the bipolar component, one head-trunion dissociation, and one aseptic loosening of the acetabular construct. For the remaining patients, no radiolucent lines around the components and no osteolysis were observed at latest follow up. Conclusion. The dual mobility cup is a highly effective option to manage unstable total hip arthroplasty. Unlike constrained devices, such implants provide encouraging radiologic results regarding the potential for loosening and osteolysis at mid- to long-term


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 185 - 185
1 Sep 2012
Slobogean GP Marra C Sanders DW
Full Access

Purpose. A recent multicentre randomized control trial (RCT) failed to demonstrate superior quality of life at one year following open reduction and internal fixation (ORIF) compared to nonoperative treatment for unstable isolated fibular fractures. We sought to determine the cost-effectiveness of ORIF compared to non-operative management of unstable fibular fractures. Method. A decision tree was used to model the results of a multicentre trial comparing ORIF versus nonoperative treatment for isolated fibular fractures. A single payer, governmental perspective was used for the analysis. Utilities (a measure of preference for a health state) were obtained from the subjects Short-Form-6D scores and used to calculated Quality Adjusted Life Years (QALYs). Probabilities for each strategy were taken from the one-year trial endpoint. Costs were obtained from the Ontario Case Costing Initiative. Sensitivity analysis was performed for all model variables to determine when ORIF is a cost-effective treatment (incremental cost per QALY gained < $75,000). Results. Nonoperative management was the preferred treatment during the one-year time-horizon. The nonoperative treatment strategy had an average cost of $2,099 $885 for an average gain of 0.717 0.064 QALYs. ORIF had an average cost of $6,455 $3,589 for an average gain of 0.734 0.051 QALYs. The incremental cost effectiveness ratio for the ORIF treatment was $256,235 per QALY. ORIF becomes the preferred treatment at extreme values for its costs (< $1,450) and its effectiveness (QALY > 0.81). Conclusion. From a single-payer, governmental perspective open reduction and internal fixation does not appear to be cost-effective; however, if operative fixation decreases the lifetime incidence of post-traumatic ankle arthrosis or a broader societal perspective with a higher willingness to pay threshold is adopted, then the economic attractiveness of ORIF would improve


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 103 - 103
1 Mar 2012
McFadyen I Curwen C Field J
Full Access

The aim of this study is to compare functional, clinical and radiological outcomes in K-wire fixation versus volar fixed-angle plate fixation in unstable, dorsally angulated distal radius fractures. Fifty-four adult patients with an isolated closed, unilateral, unstable, distal radius fracture were recruited to participate in the study. Only dorsally displaced fractures with no articular comminution were included. Patients were randomised to have their fracture treated with either closed reduction and K-wire fixation (3 wires) or fixed-angle volar plating. Both groups were immobilised in a below elbow cast for six weeks. The wires removed in the outpatients at six weeks and both groups were referred for physiotherapy. Independent clinical review was performed at three and six months post injury. Functional scoring was performed using the DASH and Gartland and Werley scoring systems. Radiographs were evaluated by an independent orthopaedic surgeon. Twenty-five patients were treated with a plate and twenty-nine with wires. There were no complications in the plate group. There were 9 complications in the K-wire group with 3 patients requiring a second operation (1 corrective osteotomy for malunion, 1 median nerve decompression and 1 retrieval of a migrated wire). The remaining complications included: 5 pin site infections (3 treated with early pin removal and 2 with oral antibiotics only), and 1 superficial radial nerve palsy. There were no tendon ruptures. Both groups scored satisfactory functional results with no statistical difference. There was a statistically significant difference in the radiological outcomes with the plate group achieving better results. We conclude that in unstable dorsally angulated distal radius fractures volar fixed-angle plate fixation is able to achieve comparable functional results to K-wire fixation with better radiological results and fewer complications. This has resulted in a change in our clinical practice