Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Bone & Joint Research
Vol. 11, Issue 2 | Pages 82 - 90
7 Feb 2022
Eckert JA Bitsch RG Sonntag R Reiner T Schwarze M Jaeger S

Aims. The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. Methods. Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. Results. At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. Conclusion. Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82–90


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 29 - 29
1 Mar 2012
White SH Roberts SJ Jones PW
Full Access

This is a study of the quality of outcome of the first 100 patients who received the Twin Peg Oxford Partial knee replacement; which has been designed with a 15 degree extra surface for contact in deep flexion, and two pins for more secure fixation. We measured the outcome in patients with anteromedial osteoarthritis at 2 years after implantation using patient perception outcome measures: the OKS (Oxford Knee Score) and a patient satisfaction questionnaire. We also measured range of motion, the AKS (American Knee Society Score-Objective), the AFS (American Knee Society Score-Functional), and carried out a radiological assessment. The results showed a mean OKS of 41, a mean AKS of 93, a mean AFS of 84, a mean range of motion of 130 degrees and a 97% satisfaction rate. Results were significantly better in male patients. There were no deaths, infections, dislocations, fractures or revisions. There were no radiolucent lines of 2 mms or more at the femoral bone-cement interfaces. The introduction of this new version of the Oxford knee shows excellent clinical and radiological results which are at least as good as those seen with the Phase 3 Oxford Partial knee replacement. Small adjustments were made to the minimally invasive approach: a reduced invasive incision for ease of implantation. For those surgeons who are concerned over the risks of femoral loosening with the Phase 3 implant, or desire an improved surface area of contact at high angles of flexion, this Twin Peg Oxford Partial knee replacement offers an excellent alternative


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 896 - 901
1 Jul 2014
Reiner T Jaeger S Schwarze M Klotz MC Beckmann NA Bitsch RG

Aseptic loosening of the femoral component is an important indication for revision surgery in unicompartmental knee replacement (UKR). A new design of femoral component with an additional peg was introduced for the cemented Oxford UKR to increase its stability. The purpose of this study was to compare the primary stability of the two designs of component. Medial Oxford UKR was performed in 12 pairs of human cadaver knees. In each pair, one knee received the single peg and one received the twin peg design. Three dimensional micromotion and subsidence of the component in relation to the bone was measured under cyclical loading at flexion of 40° and 70° using an optical measuring system. Wilcoxon matched pairs signed-rank test was performed to detect differences between the two groups. . There was no significant difference in the relative micromotion (p = 0.791 and 0.380, respectively) and subsidence (p = 0.301 and 0.176, respectively) of the component between the two groups at both angles of flexion. Both designs of component offered good strength of fixation in this cadaver study. Cite this article: Bone Joint J 2014;96-B:896–901


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims

The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery.

Methods

A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series.