Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach. We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis. Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps. Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (. sd). 5.5), 0.3° valgus (. sd. 2.7), and 0.7° extension (. sd. 3.2) for the humeral component, and 9.3° pronation (. sd. 9.7), 0.3° valgus (. sd. 4.0), and 8.6° extension (. sd. 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs. . The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results. . Cite this article: 2015;97-B:1096–1101


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 4 - 4
1 Sep 2014
Dachs R Roche S Chivers D Fleming M
Full Access

Aim. To compare radiological and clinical outcomes between triceps-detaching and triceps-sparing approaches in total elbow arthroplasty, with specific focus on cementing technique and post-operative range of motion. Methods. A retrospective review was completed of medical records and radiographs of 56 consecutively managed patients who underwent a primary total elbow arthroplasty between 2000 and 2012 at a tertiary hospital. Rheumatoid Arthritis was the predominant pathology (47/56). Data analysed included patient demographics, range of motion pre-operatively and at various stages post-operatively, approach utilized, operative time and complications. Cementing technique was graded as adequate, marginal or inadequate according to Morrey's criteria. Results. 12 patients were lost to follow-up or had incomplete records, leaving 44 patients for analysis. 15 patients had a triceps-sparing approach, and 29 had a variation of a triceps-detaching approach. Average follow-up was 56.1 months. Flexion range of motion in the triceps-sparing group improved from 25°–122° (±19.6°) pre-op to 10°–140° (±22.5°) at final follow-up, and in the triceps-detaching group from 41°–104° (± 22.2°) pre-op to 27°–129° (±35.0°) at final follow-up. Tourniquet time averaged 85.4 (±17.0) minutes for the triceps-sparing group and 96.1 (±22.6) minutes for the triceps-detaching group. The complication rate in the triceps-sparing group was 13.3%, and included one olecranon fracture and one case of superficial wound sepsis. The complication rate for the triceps-detaching group was 24.1%, and included one patient with persistent ulnar nerve symptoms requiring transposition, one medial condyle fracture and five triceps ruptures. Three patients who had attempted repairs of the rupture developed deep infections requiring multiple further surgeries. Cementing technique was adequate in 91.7% in the triceps-sparing group and in 70.6% in the triceps-detaching group and marginal in the remainder of the cohort. Conclusion. A triceps-sparing approach results in a predictable improvement in range of motion with no compromise of the cement mantle. NO DISCLOSURES


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1198 - 1204
1 Sep 2008
Peden JP Morrey BF

This study reports our experience with total elbow replacement for fused elbows.

Between 1982 and 2004, 13 patients with spontaneously ankylosed elbows were treated with a linked semi-constrained non-custom total elbow implant. The mean age at operation was 54 years (24 to 80). The stiffness was a result of trauma in ten elbows, juvenile rheumatoid arthritis in one, and rheumatoid arthritis in two. The patients were followed for a mean of 12 years (2 to 26) and were evaluated clinically using the Mayo Elbow Performance Score, as well as radiologically.

A mean arc from 37° of extension to 118° of flexion was achieved. Outcomes were good or excellent for seven elbows at final review. Ten patients felt better or much better after total elbow replacement. However, there was a high complication rate and re-operation was required in over half of patients. Two developed peri-operative soft-tissue breakdown requiring debridement. A muscle flap with skin grafting was used for soft-tissue cover in one. Revision was undertaken in one elbow following fracture of the ulnar component. Three patients developed a deep infection. Three elbows were manipulated under anaesthesia for post-operative stiffness. Prophylactic measures for heterotopic ossification were unsuccessful.

Total elbow replacement for the ankylosed elbow should be performed with caution. However, the outcome can be reliable in the long term and have a markedly positive impact on patient function and satisfaction. The high potential for complications must be considered. We consider total elbow replacement to be an acceptable procedure in selected patients with reasonable expectations.