Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Bone & Joint Open
Vol. 2, Issue 5 | Pages 338 - 343
21 May 2021
Harvey J Varghese BJ Hahn DM

Aims. Displaced distal radius fractures were investigated at a level 1 major trauma centre during the COVID-19 2020 lockdown due to the implementation of temporary changes in practice. The primary aim was to establish if follow-up at one week in place of the 72-hour British Orthopaedic Association Standards for Trauma & Orthopaedics (BOAST) guidance was safe following manipulation under anaesthetic. A parallel adaptation during lockdown was the non-expectation of Bier’s block. The secondary aim was to compare clinical outcomes with respect to block type. Methods. Overall, 90 patients were assessed in a cross-sectional cohort study using a mixed, retrospective-prospective approach. Consecutive sampling of 30 patients pre-lockdown (P1), 30 during lockdown (P2), and 30 during post-lockdown (P3) was applied. Type of block, operative status, follow-up, and complications were extracted. Primary endpoints were early complications (≤ one week). Secondary endpoints were later complications including malunion, delayed union or osteotomy. Results. In P1, 86.6% of patients were seen between days one to three, 26.7% in P2, and 56.7% in P3. There were no documented complications from days one to three. Operative rate was 35.5%, which did not vary significantly (p= 0.712). Primary endpoints occurred between day four to seven, and included one patient each period treated for plaster cast pain. Secondary endpoints in P1 included delayed union (one patient). During P2, this included malunion (one patient), a pressure sore (one patient) and ulnar cutaneous nerve symptoms (two patients). In P3, malunion was identified in one patient. Mean follow-up was six months (4 to 9) with union rate 96%. Change in block practice varied significantly (p =<0.05). The risk ratio of complications using regional block (Bier’s) over haematoma block was 0.65. Conclusion. Follow-up adaptations during lockdown did not adversely affect patient outcomes. Regional anaesthesia is gold standard for manipulation of displaced distal radial fractures. Cite this article: Bone Jt Open 2021;2(5):338–343


Bone & Joint Research
Vol. 9, Issue 7 | Pages 429 - 439
1 Jul 2020
Tahir M Chaudhry EA Zaffar Z Anwar K Mamoon MAH Ahmad M Jamali AR Mehboob G

Aims. We hypothesized that the wide-awake local anaesthesia with no tourniquet (WALANT) technique is cost-effective, easy to use, safe, and reproducible, with a low learning curve towards mastery, having a high patient satisfaction rate. Furthermore, WALANT would be a suitable alternative for the austere and developing nation environments where lack of funds and resources are a common issue. Methods. This was a randomized control trial of 169 patients who required surgery for closed isolated distal radius fractures. The study was performed between March 2016 and April 2019 at a public sector level 1 trauma centre. General anaesthesia was used in 56 patients, Bier’s block in 58 patients, and WALANT in 55 patients. Data were collected on pre-, peri-, and postoperative parameters, clinical outcome, hospital costs, and patient satisfaction. One-way analysis of variance (ANOVA) was used with a p-value of 0.05 being significant. Results. Operations with WALANT proceeded sooner, and patients recovered faster, resulting in mean fewer missed working days (7.8 (SD 1.67)) compared with general anaesthesia (20.1 (SD 7.37)) or Bier’s block (14.1 (SD 7.65)) (p < 0.001). The WALANT patients did not develop complications, while the other patients did (p < 0.04). Clinical outcomes did not differ, nor did surgeon qualification affect clinical outcomes. Mean hospital costs were lower for WALANT ($428.50 (SD 77.71)) than for general anaesthesia ($630.63 (SD 114.77)) or Bier’s block ($734.00 (SD 37.54)) (p < 0.001). Patient satisfaction was also higher (p < 0.001). Conclusion. WALANT for distal radius fractures results in a faster recovery, is more cost-effective, has similar clinical outcomes, and has fewer complications than general anaesthesia or Bier's block. This makes WALANT an attractive technique in any setting, but especially in middle- and low-income countries. Cite this article: Bone Joint Res 2020;9(7):429–439


Aims. The aim of this study was to compare the clinical effectiveness of Kirschner wire (K-wire) fixation with locking-plate fixation for patients with a dorsally displaced fracture of the distal radius in the five years after injury. Patients and Methods. We report the five-year follow-up of a multicentre, two-arm, parallel-group randomized controlled trial. A total of 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation were recruited from 18 trauma centres in the United Kingdom. Patients were excluded if the surface of the wrist joint was so badly displaced it required open reduction. In all, 448 patients were randomized to receive either K-wire fixation or locking-plate fixation. In the K-wire group, there were 179 female and 38 male patients with a mean age of 59.1 years (19 to 89). In the locking-plate group, there were 194 female and 37 male patients with a mean age of 58.3 years (20 to 89). The primary outcome measure was the patient-rated wrist evaluation (PRWE). Secondary outcomes were health-related quality of life using the EuroQol five-dimension three-level (EQ-5D-3L) assessment, and further surgery related to the index fracture. Results. At 12 months, 402/448 participants (90%) recruited into the main study provided PRWE scores. At year two, 294 participants (66%) provided scores; at year five, 198 participants (44%) provided scores. There was no clinically relevant difference in the PRWE at any point during the five-year follow-up; at five years, the PRWE score was 8.3 (12.5) in the wire group and 11.3 (15.6) in the plate group (95% confidence interval -6.99 to 0.99; p = 0.139). Nor was there a clinically relevant difference in health-related quality of life. Only three participants had further surgery in the five years after their injury (one in the wire group and two in the plate group). Conclusion. This follow-up study continues to show no evidence of a difference in wrist pain, wrist function, or quality of life for patients treated with wires versus locking plates in the five years following a dorsally displaced fracture of the distal radius. Cite this article: Bone Joint J 2019;101-B:978–983


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1082 - 1089
1 Aug 2015
Tubeuf S Yu G Achten J Parsons NR Rangan A Lamb SE Costa ML

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius. . The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care. . There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89 322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30 000. . Compared with locking-plate fixation, K-wire fixation is a ‘cost saving’ intervention, with similar health benefits. Cite this article: Bone Joint J 2015;97-B:1082–9


Bone & Joint Open
Vol. 5, Issue 8 | Pages 652 - 661
8 Aug 2024
Taha R Davis T Montgomery A Karantana A

Aims

The aims of this study were to describe the epidemiology of metacarpal shaft fractures (MSFs), assess variation in treatment and complications following standard care, document hospital resource use, and explore factors associated with treatment modality.

Methods

A multicentre, cross-sectional retrospective study of MSFs at six centres in the UK. We collected and analyzed healthcare records, operative notes, and radiographs of adults presenting within ten days of a MSF affecting the second to fifth metacarpal between 1 August 2016 and 31 July 2017. Total emergency department (ED) attendances were used to estimate prevalence.


Bone & Joint Open
Vol. 4, Issue 2 | Pages 87 - 95
10 Feb 2023
Deshmukh SR Kirkham JJ Karantana A

Aims

The aim of this study was to develop a core outcome set of what to measure in all future clinical research on hand fractures and joint injuries in adults.

Methods

Phase 1 consisted of steps to identify potential outcome domains through systematic review of published studies, and exploration of the patient perspective through qualitative research, consisting of 25 semi-structured interviews and five focus groups. Phase 2 involved key stakeholder groups (patients, hand surgeons, and hand therapists) prioritizing the outcome domains via a three-round international Delphi survey, with a final consensus meeting to agree the final core outcome set.


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1225 - 1233
1 Nov 2022
Png ME Petrou S Achten J Ooms A Lamb SE Hedley H Dias J Costa ML

Aims

The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting.

Methods

An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 709 - 714
1 Jun 2022
Stirling PHC Simpson CJ Ring D Duckworth AD McEachan JE

Aims

The aim of this study was to describe the introduction of a virtual pathway for the management of patients with a suspected fracture of the scaphoid, and to report patient-reported outcome measures (PROMs) and satisfaction following treatment using this service.

Methods

All adult patients who presented with a clinically suspected scaphoid fracture that was not visible on radiographs at the time of presentation during a one-year period were eligible for inclusion in the pathway. Demographic details, findings on examination, and routine four-view radiographs at the time of presentation were collected. All radiographs were reviewed virtually by a single consultant hand surgeon, with patient-initiated follow-up on request. PROMs were assessed at a minimum of one year after presentation and included the abbreviated version of the Disabilities of the Arm, Shoulder and Hand Score (QuickDASH), the EuroQol five-dimension five-level health questionnaire (EQ-5D-5L), the Net Promoter Score (NPS), and return to work.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 997 - 1003
29 Nov 2021
Dean BJF

Aims

Current National Institute for Health and Clinical Excellence (NICE) guidance advises that MRI direct from the emergency department (ED) should be considered for suspected scaphoid fractures. This study reports the current management of suspected scaphoid fractures in the UK and assesses adherence with NICE guidance.

Methods

This national cross-sectional study was carried out at 87 NHS centres in the UK involving 122 EDs and 184 minor injuries units (MIUs). The primary outcome was availability of MRI imaging direct from the ED. We also report the specifics of patient management pathways for suspected scaphoid fractures in EDs, MIUs, and orthopaedic services. Overall, 62 of 87 centres (71%) had a guideline for the management of suspected scaphoid fractures.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1542 - 1548
2 Nov 2020
Stirling PHC Oliver WM Ling Tan H Brown IDM Oliver CW McQueen MM Molyneux SG Duckworth AD

Aims

The primary aim of this study was to describe patient satisfaction and health-related quality of life (HRQoL) following corrective osteotomy for a symptomatic malunion of the distal radius.

Methods

We retrospectively identified 122 adult patients from a single centre over an eight-year period who had undergone corrective osteotomy for a symptomatic malunion of the distal radius. The primary long-term outcome was the Patient-Rated Wrist Evaluation (PRWE) score. Secondary outcomes included the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, the EQ-5D-5L score, complications, and the Net Promoter Score (NPS). Multivariate regression analysis was used to determine factors associated with the PRWE score.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 874 - 880
1 Jul 2020
Langerhuizen DWG Bergsma M Selles CA Jaarsma RL Goslings JC Schep NWL Doornberg JN

Aims

The aim of this study was to investigate whether intraoperative 3D fluoroscopic imaging outperforms dorsal tangential views in the detection of dorsal cortex screw penetration after volar plating of an intra-articular distal radial fracture, as identified on postoperative CT imaging.

Methods

A total of 165 prospectively enrolled patients who underwent volar plating for an intra-articular distal radial fracture were retrospectively evaluated to study three intraoperative imaging protocols: 1) standard 2D fluoroscopic imaging with anteroposterior (AP) and elevated lateral images (n = 55); 2) 2D fluoroscopic imaging with AP, lateral, and dorsal tangential views images (n = 50); and 3) 3D fluoroscopy (n = 60). Multiplanar reconstructions of postoperative CT scans served as the reference standard.