Ensuring the accuracy of the intra-operative orientation of the acetabular component during a total hip replacement can be difficult. In this paper we introduce a reproducible technique using the
Orientation of the native acetabular plane as defined by the
Abstract. Optimal acetabular component position in Total Hip Arthroplasty is vital for avoiding complications such as dislocation and impingement,
Background. The
Introduction: A critical determinant of early dislocation following total hip arthroplasty (THA) is correct positioning of the acetabular component. This challenging aspect of THA has not been lessened by the introduction of more minimally invasive techniques. In this paper we introduce a simple and reproducible technique, which uses the
Abstract. Background. Optimal acetabular component position in Total Hip Arthroplasty is vital for avoiding complications such as dislocation, impingement, abductor muscle strength and range of motion.
Purpose of the study: Anteversion of the cup during total hip arthroplasty (THA) is crucial for preventing the risk of dislocation. Interest has recently focused on an anatomic element often observed in the operative field during hip surgery: the
Background. Cup inclination is a major factor in the success of a total hip replacement. An open cup position can lead to dislocation or increased wear from rim loading and a closed cup position lead to impingement against the femoral neck or psoas. Although the ideal inclination for cup position is recommended as between 40 and 45 degrees, accurate positioning of the implant might be influenced by pelvic flexion and movement of the patient's pelvis during the procedure. We wanted to examine if the transvers acetabular ligament (TAL) could be used to determine cup inclination intra-operatively. Methods. 16 hips from 9 cadaveric specimens were used for the study. A computer navigation system (Brain lab) was used to measure and document the exact inclination and version of the acetabular trial component in three positions: flush with the transvers acetabular ligament (TAL), with the rim of the cup 5 mm from the TAL in a cranial direction and with the rim of the cup 5 mm caudally displaced. Statistical analysis of the results was performed by the Department of Biostatistics. Findings. With the cup positioned flush with the TAL, the average version was 43 degrees (range 37 to 47 degrees.) When there was a 5 mm gap between the TAL and the cup the average inclination was 28 degrees (21 to 35 degrees.) When the cup was opened so it covered the TAL by 5 mm the average inclination increased to 64 degrees (55 to 75 degrees.) The average anteversion angle was 18 degrees (range 15 to 25 degrees.). Conclusion. We found the
Introduction. Malalignment of cup in total hip replacement (THR) increases rates of dislocation, impingement, acetabular migration, pelvic osteolysis, leg length discrepancy and polyethylene wear. Many surgeons orientate the cup in the same anteversion and inclination as the inherent anatomy of the acetabulum. The
Introduction. The aim of this study was to assess the accuracy of aligning the cup with the
Introduction: Autopsy findings (Jensen and Lauritzen 1976, Catterall et al. 1982) as well as own MRI studies (Lange et al. 1996) indicate that in Perthes’ disease there is an early cartilaginous enlargement of the femoral head. Lack of concomitant acetabular enlargement will lead to loss of containment and subluxation. We divided the
Background: The positioning of the acetabular component is of critical importance in total hip arthroplasty. Due to the orientation of the acetabulum and limitations of observation imposed at the operative site mal-positioning is common. We believe that by utilising the
Current methods for restoring or preserving limb length following total hip arthroplasty are anatomically inaccurate, as they do not consider acetabular and femoral height independently. In order to address this, we present and evaluate a technique that uses the
Published data has shown that only 45% of acetabular components were in an acceptable position, where positioning was determined clinically by the surgeon intra-operatively. The aim of this study is to assess the accuracy of cup orientation, using computer tomography (CT), when the TAL is used as the intra-operative guide. In this prospective study, the TAL was used as the anatomical reference for positioning the cup. The TAL was graded 1 to 4 based on visibility of the ligament. The version and abduction angles were estimated clinically and recorded by the surgeon after insertion of the cup. Post-operatively the true orientation of the cup was measured using CT. Statistical analyses were carried out to calculate the difference between the intra-operative estimation of cup orientation and the true cup position as measured by CT. Ethical approval was granted and informed consent was obtained for all the patients. Forty-eight hips have been studied to date. The TAL was easily identifiable in the majority of cases. Overall, the cup version was under-estimated by the surgeon when the TAL was utilized as the anatomical landmark. The true mean acetabular component version was 26.5 degrees [range from 11 to 41 degrees]. The true mean abduction angle was 43.6 degrees [range from 35 to 55 degrees]. The mean difference between surgeon estimation and CT measurement for cup version was 4 degrees of underestimation [range from 14 degrees of underestimation to 11 degrees of overestimation]. The mean difference for abduction angle was 0.1 degrees [range from 14 degrees of underestimation to 10 degrees of overestimation]. When using TAL as an intra-operative guide, 64% of acetabular components were within the target range of 15 to 30 degrees of anteversion, as measured by CT, compared to 45% in previously published study (Wines, A &
McNicol, D, J. Arthroplasty, 2006). TAL improves the accuracy of acetabular component version, when utilized as an anatomical landmark during cup insertion in primary total hip arthroplasty. It is reliable and easily identifiable in the majority of cases.
It has recently been reported that the transverse
acetabular ligament (TAL) is helpful in determining the position
of the acetabular component in total hip replacement (THR). In this
study we used a computer-assisted navigation system to determine
whether the TAL is useful as a landmark in THR. The study was carried
out in 121 consecutive patients undergoing primary THR (134 hips),
including 67 dysplastic hips (50%). There were 26 men (29 hips)
and 95 women (105 hips) with a mean age of 60.2 years (17 to 82)
at the time of operation. After identification of the TAL, its anteversion
was measured intra-operatively by aligning the inferomedial rim
of the trial acetabular component with the TAL using computer-assisted
navigation. The TAL was identified in 112 hips (83.6%). Intra-observer reproducibility
in the measurement of anteversion of the TAL was high, but inter-observer
reproducibility was moderate. Each surgeon was able to align the trial component according
to the target value of the angle of anteversion of the TAL, but
it was clear that methods may differ among surgeons. Of the measurements
of the angle of anteversion of the TAL, 5.4% (6 of 112 hips) were
outliers from the safe zone. In summary, we found that the TAL is useful as a landmark when
implanting the acetabular component within the safe zone in almost
all hips, and to prevent it being implanted in retroversion in all
hips, including dysplastic hips. However, as anteversion of the
TAL may be excessive in a few hips, it is advisable to pay attention
to individual variations, particularly in those with severe posterior
pelvic tilt. Cite this article:
The orientation of the acetabular component can
influence both the short- and long-term outcomes of total hip replacement
(THR). We performed a prospective, randomised, controlled trial
of two groups, comprising of 40 patients each, in order to compare
freehand introduction of the component with introduction using the transverse
acetabular ligament (TAL) as a reference for anteversion. Anteversion
and inclination were measured on pelvic radiographs. With respect to anteversion, in the freehand group 22.5% of the
components were outside the safe zone versus 0%
in the
Despite a lack of long-term follow-up, there
is an increasing trend towards using femoral heads of large diameter
in total hip replacement (THR), partly because of the perceived
advantage of lower rates of dislocation. However, increasing the
size of the femoral head is not the only way to reduce the rate
of dislocation; optimal alignment of the components and repair of
the posterior capsule could achieve a similar effect. . In this prospective study of 512 cemented unilateral THRs (Male:Female
230:282) performed between 2004 and 2011, we aimed to determine
the rate of dislocation in patients who received a 22 mm head on
a 9/10 Morse taper through a posterior approach with capsular repair
and using the
Introduction. Acetabular component orientation is an important determinant of outcome following total hip arthroplasty (THA). Although surgeons aim to achieve optimal cup orientation, many studies demonstrate their inability to consistently achieve this. Factors that contribute are pelvic orientation and the surgeon's ability to correctly orient the cup at implantation. The goal of this study was to determine the accuracy with which surgeons can achieve cup orientation angles. Methods. In this in vitro study using a calibrated left and right sawbone hemipelvis model, participants (n=10) were asked to place a cup mounted on its introducer giving different targets. Measurements of cup orientation were made using a stereophotogrammetry protocol to measure radiographic inclination and operative anteversion (OA). A digital inclinometer was used to measure the intra-operative inclination (IOI) which is the angle of the cup introducer relative to the floor. First, the participant stated his or her preferred IOI and OA and positioned the cup accordingly. Second, the participant had to position the cup parallel to the anteversion of the
Ideal cup positioning remains elusive both in terms of defining and achieving target. Our aim is to restore original anatomy by using the
Introduction. Cup positioning in total hip arthroplasty (THA) is an important variable for short and long term durability of any hip implant. This novel method utilises internal and external bony landmarks, and the