Advertisement for orthosearch.org.uk
Results 1 - 20 of 1106
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 367 - 370
1 Mar 2013
Bini SA Chen Y Khatod M Paxton EW

We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used while in 2713 TKRs the non-pre-coated version of the same tray was used. All the TKRs were performed between 2001 and 2009 and were cemented. TKRs implanted with a pre-coated tibial component had a lower cumulative survival than those with a non-pre-coated tibial component (p = 0.01). After adjusting for diagnosis, age, gender, body mass index, American Society of Anesthesiologists grade, femoral coupling design, surgeon volume and hospital volume, pre-coating was an independent risk factor for all-cause aseptic revision (hazard ratio 2.75, p = 0.006). Revision for aseptic loosening was uncommon for both pre-coated and non-pre-coated trays (rates of 0.12% and 0%, respectively). Pre-coating with PMMA does not appear to be protective of revision for this tibial tray design at short-term follow-up.

Cite this article: Bone Joint J 2013;95-B:367–70.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 26 - 26
1 Oct 2019
Dalury DF Chapman DM Miller MJ
Full Access

Introduction. Enhanced pain and rehabilitation protocols have significantly improved patient recovery following primary TKR. Little has been written on how the protocols have affected the revision TKR patient. We report on a matched group of revision and primary TKR patients treated with the identical pain and rehab program. Materials and Methods. 40 aseptic RTKR patients who underwent a full femoral and tibial revision were matched by age, sex, and BMI to a group of patients who underwent a cemented tri-compartmental primary TKR. All revision knees had uncemented stemmed femurs and tibias. All 40 patients had either a metaphyseal sleeve on either the femur or tibia or both. Patients in both groups were treated with an identical post op pain protocol (Spinal anesthetic, local infiltrative analgesia and multimodal oral pain management along with rapid rehabilitation). All patients were mobilized on POD1 and allowed weight bearing as tolerated. Patients were followed for a minimum of 1 year. KSS at 6 weeks and 1 year were recorded for both groups. Results. There was no significant difference in length of stay between the RTKR and the primary TKR (1.2 days versus 1.1 days). Average oral morphine equivalents used during the hospitalization was 38 for the RTKR and 42 for the primary group. There was 1 readmission in each group: GI distress in the RTKR and urinary retention in the primary group. There no were reoperations, wound healing problems, identified thromboembolic events or manipulations under anesthesia in either group. KSS for the RTKR group averaged 87.3 at 6 weeks (range 45 to 99) and 89.1at minimum 1 year (range 52 to100). KSS for the primary group averaged 89.9 (range 71 to 100) at 6 week follow-up and 93.2 (range 54 to 100) at minimum follow-up. Range of motion at final follow up averaged1.2 (0–10) to 114.1 (55–135) for the RTKR group and 1 (0–8) to 121.3 (85–140) for the primary group. Conclusion. Despite more complex surgery in the revision total knee patient, enhanced pain and rehabilitation protocols have enabled the RTKR patient to have a similar recovery and outcome compared to the primary TKR patient. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 10 - 10
1 Feb 2021
Rahman F Chan H Zapata G Walker P
Full Access

Background. Artificial total knee designs have revolutionized over time, yet 20% of the population still report dissatisfaction. The standard implants fail to replicate native knee kinematic functionality due to mismatch of condylar surfaces and non-anatomically placed implantation. (Daggett et al 2016; Saigo et al 2017). It is essential that the implant surface matches the native knee to prevent Instability and soft tissue impingement. Our goal is to use computational modeling to determine the ideal shapes and orientations of anatomically-shaped components and test the accuracy of fit of component surfaces. Methods. One hundred MRI scans of knees with early osteoarthritis were obtained from the NIH Osteoarthritis Initiative, converted into 3D meshes, and aligned via an anatomic coordinate system algorithm. Geomagic Design X software was used to determine the average anterior-posterior (AP) length. Each knee was then scaled in three dimensions to match the average AP length. Geomagic's least-squares algorithm was used to create an average surface model. This method was validated by generating a statistical shaped model using principal component analysis (PCA) to compare to the least square's method. The averaged knee surface was used to design component system sizing schemes of 1, 3, 5, and 7 (fig 1). A further fifty arthritic knees were modeled to test the accuracy of fit for all component sizing schemes. Standard deviation maps were created using Geomagic to analyze the error of fit of the implant surface compared to the native femur surface. Results. The average shape model derived from Principal Component Analysis had a discrepancy of 0.01mm and a standard deviation of 0.05mm when compared to Geomagic least squares. The bearing surfaces showed a very close fit within both models with minimal errors at the sides of the epicondylar line (fig 2). The surface components were lined up posteriorly and distally on the 50 femurs. Statistical Analysis of the mesh deviation maps between the femoral condylar surface and the components showed a decrease in deviation with a larger number of sizes reducing from 1.5 mm for a 1-size system to 0.88 mm for a 7-size system (table 1). The femoral components of a 5 or 7-size system showed the best fit less than 1mm. The main mismatch was on the superior patella flange, with maximum projection or undercut of 2 millimeters. Discussion and Conclusion. The study showed an approach to total knee design and technique for a more accurate reproduction of a normal knee. A 5 to 7 size system was sufficient, but with two widths for each size to avoid overhang. Components based on the average anatomic shapes were an accurate fit on the bearing surfaces, but surgery to 1-millimeter accuracy was needed. The results showed that an accurate match of the femoral bearing surfaces could be achieved to better than 1 millimeter if the component geometry was based on that of the average femur. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 20 - 20
10 May 2024
Sim K Zhu M Young S
Full Access

Introduction. Individuals with significant hip and knee trauma receive total knee (TKA) and total hip arthroplasty (THA) as definitive end-stage procedures. In Aotearoa, injury-related costs, including workers compensation, may be funded by ACC. With a steady increase of arthroplasty procedures in Aotearoa, we aim to understand the magnitude and characteristics of such procedures to inform future healthcare strategies. Method. This is a longitudinal collaborative study from 1st January 2000 to 31st December 2020, using ACC and New Zealand Joint Registry databases. Total cost was subcategorised into social and medical cost for analysis. Results. ACC funded 10179 TKA and 5611 THA, amounting to 918 million New Zealand Dollars. Most clients were between 55 and 65 years of age at time of surgery, with greater representation by Male sex and European prioritised ethnicity. Māori and Pacific peoples represent less than 10% of the study population. ACC identified requiring more than 182 days of workers’ compensation as a significant marker for needing additional supports. Risk of this was 21% for TKA and 11% for THA, with risk factors being younger age (RR 0.96), Male sex (TKA RR 1.12, THA RR 1.23), and heavy work-types (TKA RR 1.50, THA RR 1.57). Discussion. Supporting individuals with post-traumatic lower limb arthroplasty is costly. Workers’ compensation contributes to a significant proportion of social expenditure. Risk factors for increased cost utilisation can be used to highlight vulnerable clients and target interventions. Conclusions. This is one of few nationwide studies investigating the healthcare cost of post-traumatic lower limb arthroplasty. We need to focus on injury prevention, targeted treatment, and rehabilitation protocols to improve recovery and reduce time off work. These findings would be of interest to multiple stakeholders


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 33 - 33
1 Dec 2022
Abbas A Lex J Toor J Mosseri J Khalil E Ravi B Whyne C
Full Access

Total knee and hip arthroplasty (TKA and THA) are two of the highest volume and resource intensive surgical procedures. Key drivers of the cost of surgical care are duration of surgery (DOS) and postoperative inpatient length of stay (LOS). The ability to predict TKA and THA DOS and LOS has substantial implications for hospital finances, scheduling and resource allocation. The goal of this study was to predict DOS and LOS for elective unilateral TKAs and THAs using machine learning models (MLMs) constructed on preoperative patient factors using a large North American database. The American College of Surgeons (ACS) National Surgical and Quality Improvement (NSQIP) database was queried for elective unilateral TKA and THA procedures from 2014-2019. The dataset was split into training, validation and testing based on year. Multiple conventional and deep MLMs such as linear, tree-based and multilayer perceptrons (MLPs) were constructed. The models with best performance on the validation set were evaluated on the testing set. Models were evaluated according to 1) mean squared error (MSE), 2) buffer accuracy (the number of times the predicted target was within a predesignated buffer of the actual target), and 3) classification accuracy (the number of times the correct class was predicted by the models). To ensure useful predictions, the results of the models were compared to a mean regressor. A total of 499,432 patients (TKA 302,490; THA 196,942) were included. The MLP models had the best MSEs and accuracy across both TKA and THA patients. During testing, the TKA MSEs for DOS and LOS were 0.893 and 0.688 while the THA MSEs for DOS and LOS were 0.895 and 0.691. The TKA DOS 30-minute buffer accuracy and ≤120 min, >120 min classification accuracy were 78.8% and 88.3%, while the TKA LOS 1-day buffer accuracy and ≤2 days, >2 days classification accuracy were 75.2% and 76.1%. The THA DOS 30-minute buffer accuracy and ≤120 min, >120 min classification accuracy were 81.6% and 91.4%, while the THA LOS 1-day buffer accuracy and ≤2 days, >2 days classification accuracy were 78.3% and 80.4%. All models across both TKA and THA patients were more accurate than the mean regressors for both DOS and LOS predictions across both buffer and classification accuracies. Conventional and deep MLMs have been effectively implemented to predict the DOS and LOS of elective unilateral TKA and THA patients based on preoperative patient factors using a large North American database with a high level of accuracy. Future work should include using operational factors to further refine these models and improve predictive accuracy. Results of this work will allow institutions to optimize their resource allocation, reduce costs and improve surgical scheduling. Acknowledgements:. The American College of Surgeons National Surgical Quality Improvement Program and the hospitals participating in the ACS NSQIP are the source of the data used herein; they have not verified and are not responsible for the statistical validity of the data analysis or the conclusions derived by the authors


Bone & Joint Open
Vol. 2, Issue 8 | Pages 679 - 684
2 Aug 2021
Seddigh S Lethbridge L Theriault P Matwin S Dunbar MJ

Aims. In countries with social healthcare systems, such as Canada, patients may experience long wait times and a decline in their health status prior to their operation. The aim of this study is to explore the association between long preoperative wait times (WT) and acute hospital length of stay (LoS) for primary arthroplasty of the knee and hip. Methods. The study population was obtained from the provincial Patient Access Registry Nova Scotia (PARNS) and the Canadian national hospital Discharge Access Database (DAD). We included primary total knee and hip arthroplasties (TKA, THA) between 2011 and 2017. Patients waiting longer than the recommended 180 days Canadian national standard were compared to patients waiting equal or less than the standard WT. The primary outcome measure was acute LoS postoperatively. Secondarily, patient demographics, comorbidities, and perioperative parameters were correlated with LoS with multivariate regression. Results. A total of 11,833 TKAs and 6,627 THAs were included in the study. Mean WT for TKA was 348 days (1 to 3,605) with mean LoS of 3.6 days (1 to 98). Mean WT for THA was 267 days (1 to 2,015) with mean LoS of 4.0 days (1 to 143). There was a significant increase in mean LoS for TKA waiting longer than 180 days (2.5% (SE 1.1); p = 0.028). There was no significant association for THA. Age, sex, surgical year, admittance from home, rural residence, household income, hospital facility, the need for blood transfusion, and comorbidities were all found to influence LoS. Conclusion. Surgical WT longer than 180 days resulted in increased acute LoS for primary TKA. Meeting a shorter WT target may be cost-saving in a social healthcare system by having shorter LoS. Cite this article: Bone Jt Open 2021;2(8):679–684


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 138 - 138
1 Feb 2020
Schwarzkopf R Chow J Burkhardt J Gittins M Kaper B Fabi D Hanson B Kopjar B
Full Access

Background. The JOURNEY™ II Cruciate-Retaining Total Knee System (JIICR) and the JOURNEY™ II Bi-Cruciate Stabilized Total Knee System (JIIBCS) (both, Smith & Nephew, Memphis, TN, USA) are used for the treatment of end-stage degenerative knee arthritis. Belonging to the JOURNEY family of knee implants, the relatively new devices are designed to provide guided motion. Studies suggest that long-term outcomes of robotic-assisted navigation in total knee arthroplasty (TKA) are superior to the classical approach. This is the first report describing early postoperative outcomes of the NAVIO® robotic-assisted surgical navigation using the JOURNEY™ II family of knee implants. Materials & Methods. In this ongoing study, six investigational sites in the US prospectively enrolled 122 patients (122 TKAs, 64 JIIBCS and 58 JIICR). Patients underwent TKA using the NAVIO system (Figure 1), a next-generation semi-autonomous tool that uses handheld miniaturized robotic-assisted instrumentation that the surgeon manipulates in 6 degrees of freedom, but restricts cutting to within the confines of the pre-designated resection area of the patient's bone. The primary outcome was postoperative mechanical alignment on long leg X-ray at one month postoperative compared to operative target alignment. Alignment within ±3 degrees of the target alignment was considered a success. Results. Average age was 65.7 years (range, 39–79); 60.7% were females. All patients underwent patella resurfacing. Two patients had revision prior to the one-month follow-up visit; two patients withdrew from the study. 95% (112/118) attended the one-month follow-up. Four patients were missing either baseline or follow-up long leg X-ray, resulting in 108 evaluated TKAs. Overall, 92.6% (100/108) of TKAs were within 3 degrees of the target alignment. Of these, 24.1%, 39.8-, 19.4%, and 9.3% were at 0, 1, 2, and 3 degrees of the target alignment, respectively. There were two revisions, one at 18 days postoperative and the second at 27 days postoperative. Discussion. At the one-month follow-up, the NAVIO™ Robotic Assisted TKA procedures resulted in a very high success rate of 92.6% in achieving planned mechanical alignment compared to standard instruments as historical control (73.4%) based on literature. 1. This demonstrates the improved accuracy and reliability of the NAVIO™ Robotic Assisted Surgical System for TKA procedures. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 118 - 118
2 Jan 2024
Stroobant L Verstraete M Onsem S Victor J Chevalier A
Full Access

Numerous papers present in-vivo knee kinematics data following total knee arthroplasty (TKA) from fluoroscopic testing. Comparing data is challenging given the large number of factors that potentially affect the reported kinematics. This paper aims at understanding the effect of following three different factors: implant geometry, performed activity and analysis method.

A total of 30 patients who underwent TKA were included in this study. This group was subdivided in three equal groups: each group receiving a different type of posterior stabilized total knee prosthesis. During single-plane fluoroscopic analysis, each patient performed three activities: open chain flexion extension, closed chain squatting and chair-rising. The 2D fluoroscopic data were subsequently converted to 3D implant positions and used to evaluate the tibiofemoral contact points and landmark-based kinematic parameters.

Significantly different anteroposterior translations and internal-external rotations were observed between the considered implants. In the lateral compartment, these differences only appeared after post-cam engagement. Comparing the activities, a significant more posterior position was observed for both the medial and lateral compartment in the closed chain activities during mid-flexion. A strong and significant correlation was found between the contact-points and landmarks-based analyses method. However, large individual variations were also observed, yielding a difference of up to 25% in anteroposterior position between both methods.

In conclusion, all three evaluated factors significantly affect the obtained tibiofemoral kinematics. The individual implant design significantly affects the anteroposterior tibiofemoral position, internal-external rotation and timing of post-cam engagement. Both kinematics and post-cam engagement additionally depend on the activity investigated, with a more posterior position and associated higher patella lever arm for the closed chain activities. Attention should also be paid to the considered analysis method and associated kinematics definition: analyzing the tibiofemoral contact points potentially yields significantly different results compared to a landmark-based approach.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 55 - 55
1 Apr 2019
Van Onsem S Verstraete M Van Der Straeten C Victor J
Full Access

Background. Kinematic patterns in total knee arthroplasty (TKA) can vary considerably from the native knee. No study has shown a relation between a given kinematic pattern and patient satisfaction yet. Questions. The purpose of this study was to test whether the kinematical pattern, and more specifically the anteroposterior translation during (1) open kinetic chain flexion-extension, (2) closed kinetic chain chair rising and (3) squatting, is related to the level of patient satisfaction after TKA. Methods. Thirty TKA patients were tested using single plane fluoroscopy. Tibiofemoral kinematics were analyzed for 3 activities of daily living (open chain flexion-extension (FE) and closed chain chair rising (CH) and squatting(SQ)). A two- step cluster analysis was performed which resulted in two clusters of patients based on the KOOS and KSS questionnaires. Cluster 1 (CL1) contained patients with good PROMs, cluster 2 (CL2) contained patients with poorer PROMs. Tibiofemoral kinematics were compared between and within both clusters. Results. Significant worse PROMs were found in cluster 2 for all KOOS and KSS subscores (P<0.001). Open chain movement: Concerning the open chain flexion extension no significant difference was found between the two clusters. Closed chain movements: On the medial side, an initial anterior translation (femur relative to tibia) was found in cluster 1 during early flexion but in cluster 2 this translation was steeper and ran more anteriorly. In mid-flexion a stable medial compartment was found in cluster 1 where cluster 2 started moving posteriorly already. In deep flexion a posterior translation was evaluated in both clusters. Concerning the lateral side, a small initial anterior translation in early flexion was found followed by a posterior translation in mid flexion which continued in deep flexion Cluster 1 moved significantly more posterior in deep flexion. Conclusion. This is one of the first studies to evaluate the influence of total knee kinematics on patient reported outcomes. We found that patients with poorer PROMs experience (1) a more pronounced paradoxical anterior motion on the medial side followed by (2) a less stable medial compartment in mid flexion and (3) less posterior translation in deep flexion on the lateral side


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 52 - 52
1 Oct 2020
Dalury DF Chapman DM
Full Access

Introduction. One of the main considerations in the revision TKR setting is deciding on the level of constraint to be utilized once the bone defects have been reconstructed. There is a fear that employing a maximally constrained insert could compromise long term results. We report on a consecutive series of full tibial and femoral component revisions all treated with a maximally conforming insert and followed for a minimum of 5 years. Materials and Methods. The study group consisted of 76 consecutive revision TKR in 76 patients where both the femur and the tibia were revised. 4 patients died and 6 were lost to follow up. Final cohort had an average age of 70 years, average BMI of 31 and there were 39 males in the group. Average time to revision was 7 years (range 1–10 years) and the reasons for revision included infection in 28, aseptic loosening 26, osteolysis and poly wear in 9 and 13 other. All were treated with the same revision system and an identical maximally conforming tibial rotating platform insert and followed for an average of 7 years (range 5–14 years). Results. one patient required additional surgery during the study period for a patella fracture. There were no manipulations. Average Knee Society Scores increased from an average of 55 to 89 at final follow up. No implants were loose or at risk of loosening and no knee sustained any mechanical complications related to the insert. Conclusion. Despite fears to the contrary, we did not identify any issues in using a maximally constrained insert in this consecutive group of revision total knee patients. It is unclear if the fact that these inserts were of a rotating platform design is important. In this group of revision TKRs, using the maximal level of constraint did not appear to negatively influence outcome at mid-term follow up


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 273 - 273
1 Mar 2004
Guiton T
Full Access

Aims: The purpose of this report is to present the short-term clinical performance of total knee arthroplasties performed with the Scorpio+ posteriorly stabilized mobile bearing knee. Methods: 100 Scorpio+ knees were implanted in 96 patients consecutively by the same surgeon and evaluated at one year of follow-up. All patients were assessed clinically using the IKS Score, Western Ontario McMaster Score (WOMAC), a chair rise evaluation6 and radiographically with long leg radiographs, standard A/P, lateral and patellar skyline views. Results: At one year of follow-up the average Range of Motion was 123° with an IKS Score averaging 191, an average knee score of 94, an average functional knee score of 97, and an average WOMAC score of 92. Furthermore, 95 out of 96 patients were able to arise from a chair without using their arms at 1 year of follow-up.

Radiographically no radiolucent lines were visible and all patellar components were centered. Conclusions: Patients with the Scorpio+ MBK demonstrated satisfactory clinical outcomes especially regarding overall stability, range of motion (average flexion 123°) and extensor mechanism function with 98% of patients being able to arise from a chair without the use of their arms at three months of follow-up.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 977 - 983
5 Nov 2024
Danielsen O Jensen CB Varnum C Jakobsen T Andersen MR Bieder MJ Overgaard S Jørgensen CC Kehlet H Gromov K Lindberg-Larsen M

Aims

Day-case success rates after primary total hip arthroplasty (THA), total knee arthroplasty (TKA), and medial unicompartmental knee arthroplasty (mUKA) may vary, and detailed data are needed on causes of not being discharged. The aim of this study was to analyze the association between surgical procedure type and successful day-case surgery, and to analyze causes of not being discharged on the day of surgery when eligible and scheduled for day-case THA, TKA, and mUKA.

Methods

A multicentre, prospective consecutive cohort study was carried out from September 2022 to August 2023. Patients were screened for day-case eligibility using well defined inclusion and exclusion criteria, and discharged when fulfilling predetermined discharge criteria. Day-case eligible patients were scheduled for surgery with intended start of surgery before 1.00 pm.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 16 - 16
1 Jul 2020
Neufeld M Masri BA
Full Access

A large proportion of wait times for primary total knee (TKA) and hip (THA) arthroplasty is the time from primary care referral to surgical consultation. To our knowledge, no study has investigated whether a referral Oxford Knee or Hip Score (OKHS) could be used to triage non-surgical referrals appropriately. The primary purpose of the current study was to determine if a referral OKHS has the predictive ability to discriminate when a knee or hip referral will be deemed conservative as compared to surgical by the surgeon during their first consultation, and to identify an OKHS cut-off point that accurately predicts when a primary TKA or THA referral will be deemed conservative. We retrospectively reviewed all consecutive primary TKA and THA consultations from a single surgeon's tertiary, high volume practice over a three-year period. Patients with a pre-consultation OKHS, BMI < 4 1, and no absolute contraindication to TJR were included. Consultation knees/hips were categorized into two groups based on surgeon's decision, those that were offered TJR during their first consolation (surgical) versus those that were not (conservative). Baseline demographic data and OKHS were abstracted. Variables of interest were compared between cohorts using the exact chi-square test and Wilcoxon rank-sum test. Spearman's rank correlation coefficients were used to measure association between pre-consult OKHS and the surgeon's decision. A receiver operator characteristic (ROC) curve analysis was used to calculate the area under the curve (AUC) and to identify a cut-off point for the pre-operative OKHS that identified whether or not a referral was deemed conservative. TKA and THA referrals were analyzed separately. The study included 1,436 knees (1,016 patients) with a median OKS of 25 (IQR 19–32) and 478 hips (388 patients) with a median OHS of 22 (IQR 16–29). Median pre-consultation OKHS demonstrated clinically and statistically significant differences between the surgical versus conservative cohorts (p 32 (sensitivity=0.997, NPV=0.992) and for hips is OHS >34 (sensitivity=0.997 NPV=0.978). ROC analysis identified severable potential lower OKHS thresholds, depending on weight of prioritization of sensitivity, specificity, and NPV. Referral OKS and OHS demonstrate good ability to discriminate when a primary TKA or THA referral will be deemed non-surgical versus surgical at their first consultation in a single surgeon's practice. Multiple potential effective OKHS thresholds can be applied as a tool to decrease wait times for primary joint arthroplasty. However, a cost analysis would aid in identifying the optimal cut-off score, and these findings need to be externally validated before they can be broadly applied


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 118 - 118
1 Sep 2012
Nakamura S Nakamura T Kobayashi M Ito H Ikeda N Nakamura K Komistek R
Full Access

Introduction. Achieving high flexion after total knee arthroplasty is very important for patients in Asian countries where deep flexion activities are an important part of daily life. The Bi-Surface Total Knee System (Japan Medical Material, Kyoto, Japan), which has a unique ball-and-socket mechanism in the mid-posterior portion of the femoral and tibial components, was designed to improve deep knee flexion and long-term durability after total knee arthroplasty (Figure 1). The purpose of this study was to determine the in vivo three dimensional kinematics of Bi-Surface Total Knee System in order to evaluate and analyze the performance of this system with other conventional TKA designs currently available in the market today. Materials and Methods. Three dimensional kinematics were evaluated during a weight-bearing deep knee bend activity using fluoroscopy and a 2D-to-3D registration technique for 66 TKA. Each knee was analyzed to determine femorotibial kinematics, including weight-bearing range of motion, anterior/posterior contact position, and tibio-femoral rotation. Results. The average weight-bearing range of motion for the entire group was 125.5∗∗∗∗∗. Forty three of sixty six knees had greater range of motion than 120∗∗∗∗∗. At full extension, the average contact positions were −0.5mm (range, from −12.2mm to 6.8mm; standard deviation 3.5mm), and −3.8mm (range, from −14.1mm to 6.0mm; standard deviation 4.9mm) for the medial compartment and the lateral compartment, respectively. At maximum flexion, the average contact position was −9.2mm (range, from −17.8mm to 2.4mm; standard deviation 3.7mm), and −14.8mm (range, from −20.1mm to 5.7mm; standard deviation 2.7mm) for the medial compartment and the lateral compartment, respectively (Figure 2). From full extension to maximum flexion, the average posterior femoral rollback observed was −8.7mm (range, from −22.1mm to 1.0mm; standard deviation 4.3mm) for the medial compartment, and −11.0mm (range, from −21.9mm to 6.6mm; standard deviation 5.4mm) for the lateral compartment. At full extension, the average axial orientation was 3.8∗∗∗∗∗ (range, from −5.3∗∗∗∗∗ to 26.4∗∗∗∗∗; standard deviation 5.2∗∗∗∗∗) of external femoral rotation. At maximum flexion, the average axial orientation was 9.5∗∗∗∗∗ (range, from −5.9∗∗∗∗∗ to 27.7∗∗∗∗∗; standard deviation 6.7∗∗∗∗∗). Therefore, from full extension to maximum flexion, the average amount of axial rotation was 5.7∗∗∗∗∗ (range, from −15.1∗∗∗∗∗ to 22.2∗∗∗∗∗; standard deviation 6.4∗∗∗∗∗). Discussion. The Bi-Surface Knee System was designed to accommodate the life style led by Asian populations, by aiming to improve both, knee flexion and long-term durability. Though durability of the device is beyond the scope of this study, subjects in this study did achieve high weight-bearing flexion, excellent posterior femoral rollback of both condyles and a normal axial rotation patterns, albeit, less than the normal knee. Also, this is the first in vivo study conducted to understand the kinematic patterns generated for subject implanted with this device. The amount of posterior rollback and axial rotation were found to be similar in nature to the normal knee as well as other established TKA devices available for implantation today, but again less than the normal knee


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 20 - 20
1 Jun 2016
Simpson J Hamer A
Full Access

Introduction. Orthopaedic theatres can be noisy. Noise exposure is known to be related to reduced cognition, reduced manual dexterity and increased rates of post-operative wound infection. Up to 50% of orthopaedic theatre staff have features of Noise-Induced Hearing Loss (NIHL) with higher levels in consultants compared to registrars. Exposure to noise levels of 90dB(A) at work for a career of 40 years, equates to a 51% risk of hearing loss. Materials & methods. A Casella CEL-242 meter was positioned in the corner of the theatre tent. Recordings were taken for 17 Total Knee Replacements (TKRs) and 11 Total Hip Replacements (THRs). This meter recorded the decibel level once per second (whereas EU Regulation requires equivalent continuous level measurement). Results. Noise levels reached 105.6dB(A) using a hammer during a TKR and 97.9dB(A) with an oscillating saw. Decibel levels exceeded 90dB(A) in every operation within the sample. Percentages of readings at 80.0dB(A) or above, per case, were calculated to estimate the proportion of our data above the EU regulation Lower Action Level; the maximum was 12.6% and they appeared to be greater in TKRs. Discussion. The small percentage of values at 80.0dB(A) or above indicates that the equivalent continuous decibel level for an average 8 hour day would be below the EU Lower Action Level. It was expected that TKRs would have higher percentages of decibels at 80.0dB(A) or above, given the greater time spent sawing in this procedure. Exposure to levels above 90dB (which occurred in every case) for short time periods is proven to cause irreversible loss of hearing. Minor damage accumulates throughout a career of 40 years, and can result in NIHL. Conclusion. Tools used in orthopaedic theatre produce impulse noises that can cause NIHL. Average daily exposure can be assumed to be acceptable. Further investigation is required


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 28 - 28
1 Mar 2017
Sun H Choi D Lipman J Wright T
Full Access

Background. Patellofemoral complications have dwindled with contemporary total knee designs that market anatomic trochlear grooves that intend to preserve normal patella kinematics. While most reports of patellofemoral complications address patella and its replacement approach, they do not focus on shape of trochlear grooves in different prostheses [1]. The purpose of this study was to characterize 3D geometry of trochlear grooves of contemporary total knee designs (NexGen, Genesis II, Logic, and Attune) defined in terms of sulcus angle and medial-lateral offset with respect to midline of femoral component in coronal view and to compare to those of native femurs derived from 20 osteoarthritic patient CT scans. Materials and Methods. Using 3D models of each implant and native femur, sulcus location and orientation were obtained by fitting a spline to connect sulcus points marked at 90°, 105°, 130°, and 145° of femoral flexion (Fig A). Implant reference plane orientations were established using inner facets of distal and posterior flanges. Reference planes of native femurs were defined using protocols developed by Eckhoff et al. [2] where coronal plane was defined using femoral posterior condyles and greater trochanter. In the coronal plane, a best fit line was used to measure sulcus angle and medial-lateral offset with respect to midline at the base of trochlear groove (Fig B). Results. With exception to Logic (0° sulcus angle & 0 mm offset), contemporary knee designs include high valgus angulations (4° to 18°) with laterally-biased offsets (3 to 5 mm). The native sulcus angle on average was slightly valgus, but varied significantly among the cohort (−0.2° ± 4.6°). Native trochlear groove offset was biased laterally (2.5 ± 1.7 mm). Discussion. We observed a considerable geometric deviation between native femur and implants in terms of sulcus angle while both geometries displayed comparable lateral bias at the base of trochlear groove. Similar to past studies by Iranpour et al. [4] and Feinstein et al. [5], a large variation in sulcus angle was observed among the selected native femurs with an average of small valgus angulation (Fig C). However, most contemporary trochlear grooves are biased towards higher valgus angulations. Retrieval and registry studies have shown that NexGen trochlear groove design (4° sulcus angle) has been shown to better accommodate natural patellas, which highlights that the differences among designs may be significant [5,6]. It remains unclear which features specifically translate to better patellafemoral outcomes, which is a merit for further study. Conflict of Interest: None. Figure A. Sulcus points defined at various flexion angles. Figure B. Best fit line to measure ML-offset and sulcus angle. Figure C. Sulcus angle comparison to past studies. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Bone & Joint Open
Vol. 5, Issue 10 | Pages 837 - 843
7 Oct 2024
Zalikha AK Waheed MA Twal C Keeley J El-Othmani MM Hajj Hussein I

Aims

This study aims to evaluate the impact of metabolic syndrome in the setting of obesity on in-hospital outcomes and resource use after total joint replacement (TJR).

Methods

A retrospective analysis was conducted using the National Inpatient Sample from 2006 to the third quarter of 2015. Discharges representing patients aged 40 years and older with obesity (BMI > 30 kg/m2) who underwent primary TJR were included. Patients were stratified into two groups with and without metabolic syndrome. The inverse probability of treatment weighting (IPTW) method was used to balance covariates.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 25 - 25
1 Jul 2022
Phillips J Tucker K
Full Access

Abstract

Introduction

There are a wide variety of implant brands and types of knee replacement available to surgeons. With time, the options available within many implant brand portfolios has grown, with alternative tibial or femoral components, tibial insert materials or shapes and patella resurfacings.

Aim

To investigate the effect of the expansion of implant brand portfolios, and to establish the potential numbers of compatible implant construct combinations.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 3 - 3
1 Jul 2022
Sheridan G Cassidy R McKee C Hughes I Hill J Beverland D
Full Access

Abstract

Introduction

With respect to survivorship following total knee arthroplasty (TKA), joint registries consistently demonstrate higher revision rates for both sexes in those less than 55 years. The current study analyses the survivorship of 500 cementless TKAs performed in this age group in a high-volume primary joint unit where cementless TKA has traditionally been used for the majority of patients.

Methods

This was a retrospective review of 500 consecutive TKAs performed in patients under the age of 55 between March 1994 and April 2017. The primary outcome measure for the study was all-cause revision. Secondary outcome measures included clinical, functional and radiological outcomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 110 - 110
23 Feb 2023
Francis S Murphy B Elsiwy Y Babazadeh S Clement N Stoney J Stevens J
Full Access

This study aims to implement and assess the inter and intra-reliability of a modernised radiolucency assessment system; the Radiolucency In cemented Stemmed Knee (RISK) arthroplasty classification. Furthermore, we assessed the distribution of regions affected by radiolucency in patients undergoing stemmed cemented knee arthroplasty.

Stemmed knee arthroplasty cases over 7-year period at a single institution were retrospectively identified and reviewed. The RISK classification system identifies five zones in the femur and five zones in the tibia in both the anteroposterior (AP) and lateral planes. Post-operative and follow-up radiographs were scored for radiolucency by four blinded reviewers at two distinct time points four weeks apart. Reliability was assessed using the kappa statistic. A heat map was generated to demonstrate the reported regions of radiolucency.

29 cases (63 radiographs) of stemmed knee arthroplasty were examined radiographically using the RISK system. Intra-reliability (0.83) and Inter-reliability (0.80) scores were both consistent with a strong level of agreement using the kappa scoring system. Radiolucency was more commonly associated with the tibial component (76.6%) compared to the femoral component (23.3%), and the tibial anterior-posterior (AP) region 1 (medial plateau) was the most affected (14.9%).

The RISK classification system is a reliable assessment tool for evaluating radiolucency around stemmed knee arthroplasty using defined zones on both AP and lateral radiographs. Zones of radiolucency identified in this study may be relevant to implant survival and corresponded well with zones of fixation, which may help inform future research.