Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model.Aims
Methods
The National Health Service produces over 500,000 tonnes of waste and 25 mega tonnes of CO2 annually. Operating room waste is segregated into different streams which are recycled, disposed of in landfill sites, or undergo costly and energy-intensive incineration processes. By assessing the quantity and recyclability of waste from primary hip and knee arthroplasty cases, we aim to identify strategies to reduce the carbon footprint of arthroplasty surgery. Data was collected prospectively at a tertiary orthopaedic hospital, in the theatres of six arthroplasty surgeons between April – July 2022. Fifteen primary total hip arthroplasty (THA) and 16 primary total knee arthroplasty (TKA) cases were included; revision and complex primary cases were excluded. Waste was categorised into non-hazardous waste, hazardous waste, recycling, sharps, and linens. Each waste category was weighed. Items disposed as non-hazardous waste were catalogued for a sample of 10 TKA and 10 THA cases. Recyclability of items was determined from packaging. Average total waste generated for THA and TKA were 14.46kg and 17.16kg respectively, with TKA generating significantly greater waste (p < 0.05). On average only 5.4% of waste was recycled in TKA and just 2.9% in THA cases. The mean recycled waste was significantly greater in TKA cases compared to THA, 0.93kg and 0.42kg respectively (p < 0.05). Hazardous waste represented the largest proportion of the waste streams for both TKA (69.2%) and THA (73.4%). On average TKA generated a significantly greater amount (11.87kg) compared to THA (10.61kg), p < 0.05. Non-hazardous waste made up 15.1% and 11.3% of total waste for TKA and THA respectively. In the non-hazardous waste, only two items (scrub brush packaging and sterile towel packaging) were identified as recyclable based on packaging. We estimate that annually
Aims. Instability is a common cause of failure after total hip arthroplasty. A novel reverse
Patients undergoing
Introduction. The purpose of the study was to determine access to and, ability to use telemedicine technology in an adult hip and knee reconstruction patient population and we seek to understand these patients' perceived benefits, risks and preferences of telemedicine. Methods. We performed a cross-sectional telephone administered survey on patients scheduled to undergo primary THA and TKA by one of six surgeons at a single academic institution between March 23 and June 2, 2020. Results. 163 patients were contacted and 113 (69.3%) completed the survey. Of the patients that completed surveys, 88% of patients reported using the internet with 94% reporting owning a device capable of videoconferencing. 78% of patients had participated in a video call in the past year and 37% having done a video visit with their physician. When asked for their preferred method for a physician visit, 80% ranked in-person as their first choice, followed by 18% preferring a video visit. Perceived benefits of telemedicine visits included reduced travel to appointments (87% agree or strongly agree) and reduced cost of attending appointments (63% agree or strongly agree). However, patients were concerned that they would not establish the same patient-physician connection (51% agree or strongly agree) and would not receive the same level of care (33% agree or strongly agree) through telemedicine visits versus in person visits. Conclusion. The majority of
In 2022, approximately 60% of inserted cups and stems in Sweden utilized cemented fixation. Two predominant brands, Refobacin Bone Cement R and Palacos R+G, both incorporating gentamicin, were employed in over 90% of primary cemented
Extensive and severe bone loss of the femur may be a result of a failed total hip arthroplasty (THA) or total knee arthroplasty (TKA) with multiple revision surgeries which may be caused by factors such as infection, periprosthetic fracture or osteolysis. The aim of this study was to assess outcomes of using the “Push-Through Total Femoral Prosthesis” (PTTF) for revision of a total hip replacement with extreme bone loss. Fourteen patients who had extensive bone defects of the femur due to failed THR's and were treated with PTTF between 2012 and 2020 were included in this study. Primary functional outcomes were assessed using Harris Hip Score (HHS), Toronto Extremity Salvage Score (TESS) and Musculoskeletal Tumor Society (MSTS) scores. Range of motion, complications, and ambulatory status were also recorded to assess secondary outcomes. Two of 14 patients underwent surgery with PTTF for both knee and hip arthroplasty revision. The mean time between index surgery and PTTF was 15 years (3 to 32 yrs.). Acetabular components were revised in six of 14 patients. After a mean follow-up of 5.9 years, hip dislocations occurred in 3 patients. All dislocated hips were in patients with retained non-constrained acetabular bearings. Patient satisfaction was high (MSTS: 67%, HHS: 61.2%, TESS 64.6%) despite a high re-operation rate and minor postoperative problems. PTTF is a unique alternative that may be considered for a failed THA revision procedure in patients with an extreme femoral bone defect. Patients are able to ambulate pain free relatively well. Routine usage of constrained liners should be considered to avoid hip dislocation which was our main problem following the procedure.
This study evaluates patient reported outcome measurement information system (PROMIS) scores after total hip arthroplasty (THA) and total ankle arthroplasty (TAA) in matched cohorts, while simultaneously evaluating implant survivorship and 90-day hospital utilization. It is hypothesized that while both procedures would yield similar PROMIS score improvements, THA would demonstrate superior mid-term implant survivorship. Primary THA and TAA patients from 2015–2022 with minimum one-year follow-up were retrospectively reviewed. After applying exclusion criteria, 2,092 THAs and 478 TAAs were included for analysis. Demographics, pre- and post-operative patient reported outcome measures (PROMs), revision surgeries, ED visits, and re-admissions were collected. THA and TAA patients were then propensity score matched at 2:1 ratio for age, sex, race, BMI, ASA, and comorbidities, resulting in a final cohort of 844 THAs and 455 TAAs for comparison. There were similar pre-operative PROMIS Pain Interference (PI) scores between THA and TAA, with both showing improvement at six weeks. However, THA patients exhibited lower PI scores at one year (53.0 versus 54.0; p=0.009). Pre-operative PROMIS Physical Function (PF) was worse in THA patients but showed greater improvement compared to TAA patients at both six weeks (p<0.001) and one year (p<0.001). Pre-operative PROMIS depression scores were similar and improved similarly in both groups. Joint-specific PROMs (HOOS for THA and FAAM for TAA) improved in both cohorts. THA demonstrated superior survivorship free of all-cause revision at five years compared to TAA (95% versus 77%; p<0.0001). Patients undergoing THA or TAA experienced significant improvements in their general and joint-specific PROMs post-operatively. However, patients undergoing THA demonstrated higher PROMIS PI and PF scores at one-year when compared to TAA, as well as improved survivorship. Generic PRO instruments enable comparison of medical treatments in different anatomic sites to the patients overall health.
Aims. The aim of this study was to compare the rate of perioperative
complications following aseptic revision
Dual mobility implants in total hip arthroplasty are designed to increase the functional head size, thus decreasing the potential for dislocation. Modular dual mobility (MDM) implants incorporate a metal liner (e.g. cobalt-chromium alloy) in a metal shell (e.g. titanium alloy), raising concern for mechanically assisted crevice corrosion at the modular liner-shell connection. We sought to examine fretting and corrosion on MDM liners, to analyze the corrosion products, and to examine histologically the periprosthetic tissues. A total of 60 retrieved liners were subjectively scored for fretting and corrosion. The corrosion products from the three most severely corroded implants were removed from the implant surface, imaged using scanning electron microscopy, and analyzed using Fourier-transform infrared spectroscopy.Aims
Methods
Fracture risks are the most common argument against the use of Ceramic on ceramic (CoC) hip implants. Question: is ceramic material at risk in case of severe local trauma? Over a long period, we tried to identify patients with a CoC prosthesis (Ceraver Osteal°)who did sustain a trauma. This was conducted in three different institutions. Eleven patients were found: 9 males and 2 females aged 17 to 70 years at time of index surgery. Accident occurred 6 months to 15 years after index: one car accident, five motorcycle accident, five significant trauma after a fall, including one ski board accident. Consequences of these trauma were: six fractures of the acetabulum with socket loosening in 4 that needed revision, two femoral shaft fracture, one orifed and one stem exchanged, one traumatic hip dislocation associated to loosening of the socket revised at 10 years, and one traumatic loosening of the socket. Ten had no consequence on ceramic integrity. One experienced a fracture of the patella from a dashboard trauma, a liner shipping was discovered during socket revision 2 years later. This is the only case of possible relation between trauma and ceramic fracture. In a more recent longitudinal study on 1856 CoC prosthesis performed from 2010 to 2021, 29 severe traumas were identified with no consequence on Ceramic material. From this limited case study, it can be assumed that Pure Alumina Ceramic well designed and manufactured, will not break after a significant trauma.
Aims. Many case reports and small studies have suggested that cobalt
ions are a potential cause of cardiac complications, specifically
cardiomyopathy, after metal-on-metal (MoM)
Many different designs of
Background. High complication rates and poor outcomes have been widely reported in patients undergoing revision of large head metal-on-metal arthroplasty. A previous study from our center showed high rates of dislocation, nerve injury, early cup loosening and pseudotumor recurrence. After noting these issues, we implemented the following changes in surgical protocol in all large head MOM revisions: 1. Use of highly porous shells in all cases 2. Use of largest femoral head possible 3. Low threshold for use of dual mobility and constrained liners when abductors affected or absent posterior capsule 4. Use of ceramic head with titanium sleeve in all cases 5. Partial resection of pseudotumor adjacent to sciatic and femoral nerves. Questions/purposes. The purpose of the present study is to compare the new surgical protocol above to our previously reported early complications in this group of patients. We specifically looked at (1) complications including reoperations; (2) radiologic outcomes; and (3) functional outcomes. Complication rates after (Group 1), and before (Group 2) modified surgical protocol were compared using Chi-square test, assuming statistical significance p<0.05. Results. Major complications occurred in 4 (8.3%) of 48 patients who had modified surgical technique, compared to 12 (38%) of 32 revisions prior to modification (p<0.05). Two hips of 48 (4.17%) endured dislocations in Group 1, compared to 9 of 32 (28%) in Group 2 (p<0.05). Four patients of 48 had repeat revision in Group 1: 2 for recurrence of pseudotumor, 1 for dislocation, and 1 for infection, compared to 6 patients who had 7 repeat revisions of 32 patients in Group 2: 3 for acetabular loosening, 3 for dislocation, and 1 for recurrence of pseudotumor (p=0.1). None of 48 revisions in Group 1 had acetabular loosening, compared to 4 of 32 in Group 2 (p=0.02). Two patients had nerve injury in Group 2, compared to none in Group 1 (p=0.16). The mean WOMAC pain score was 87.1 of 100 and the function score was 88.4 of 100 in Group 1, compared to a mean WOMAC pain score of 78 of 100 (p=0.6) and a function score of 83 of 100 in Group 2 (p=0.8). Conclusions. Modification of the surgical techniques described in the introduction has resulted in a significant decrease in complications in revision of large head MOM
The aims were to assess whether preoperative joint-specific function (JSF) and health-related quality of life (HRQoL) were associated with level of clinical frailty in patients waiting for a primary total hip arthroplasty (THA) or knee arthroplasty (KA). Patients waiting for a THA (n=100) or KA (n=100) for more than six months were prospectively recruited from the study centre. Overall, 162 patients responded to the questionnaire (81 THA; 81 KA). Patient demographics, Oxford score, EuroQol five dimension (EQ-5D) score, EuroQol visual analogue score (EQ-VAS), Rockwood Clinical Frailty Score (CFS), and time spent on the waiting list were collected. There was a significant correlation between CFS and the Oxford score (THA r=ˆ’0.838; p<0.001, KA r=ˆ’0.867; p<0.001), EQ-5D index (THA r=ˆ’0.663, p<0.001; KA r=ˆ’0.681; p< 0.001), and EQ-VAS (THA r=ˆ’0.414; p<0.001, KA r=ˆ’0.386; p<0.001). Confounding variables (demographics and waiting time) where adjusted for using multiple regression analysis. For each 8.5 (THA, 95% CI 7.1 to 10.0; p<0.001) and 9.9 (KA, 95% CI 8.4 to 11.4; p<0.001) point change in the Oxford score, there was an associated change in level of the CFS. For each 0.16 (THA, 95% CI 0.10 to 0.22; p<0.001) and 0.20 (KA, 95% CI 0.12 to 0.27; p<0.001) utility change in EQ-5D, there was an associated change in level of the CFS. EQ-VAS (THA, B=ˆ’11.5; p<0.001, KA B=ˆ’7.9; p=0.005) was also associated with CFS. JSF and HRQoL in patients awaiting THA or KA for more than six months, were independently associated with level of clinical frailty. With further prospective studies, clinical frailty may prove to be a useful metric to assist in the prioritization of arthroplasty waiting lists.
There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems. We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m2, and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized. The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up. This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI. Level of Evidence: IV
Over 8000 total hip arthroplasties (THA) in the UK were revised in 2019, half for aseptic loosening. It is believed that Artificial Intelligence (AI) could identify or predict failing THA and result in early recognition of poorly performing implants and reduce patient suffering. The aim of this study is to investigate whether Artificial Intelligence based machine learning (ML) / Deep Learning (DL) techniques can train an algorithm to identify and/or predict failing uncemented THA. Consent was sought from patients followed up in a single design, uncemented THA implant surveillance study (2010–2021). Oxford hip scores and radiographs were collected at yearly intervals. Radiographs were analysed by 3 observers for presence of markers of implant loosening/failure: periprosthetic lucency, cortical hypertrophy, and pedestal formation. DL using the RGB ResNet 18 model, with images entered chronologically, was trained according to revision status and radiographic features. Data augmentation and cross validation were used to increase the available training data, reduce bias, and improve verification of results. 184 patients consented to inclusion. 6 (3.2%) patients were revised for aseptic loosening. 2097 radiographs were analysed: 21 (11.4%) patients had three radiographic features of failure. 166 patients were used for ML algorithm testing of 3 scenarios to detect those who were revised. 1) The use of revision as an end point was associated with increased variability in accuracy. The area under the curve (AUC) was 23–97%. 2) Using 2/3 radiographic features associated with failure was associated with improved results, AUC: 75–100%. 3) Using 3/3 radiographic features, had less variability, reduced AUC of 73%, but 5/6 patients who had been revised were identified (total 66 identified). The best algorithm identified the greatest number of revised hips (5/6), predicting failure 2–8 years before revision, before all radiographic features were visible and before a significant fall in the Oxford Hip score. True-Positive: 0.77, False Positive: 0.29. ML algorithms can identify failing THA before visible features on radiographs or before PROM scores deteriorate. This is an important finding that could identify failing THA early.
There is a paucity of mid-term data on modular dual-mobility (MDM) constructs versus large (≥40 mm) femoral heads (LFH) in revision total hip arthroplasties (THAs). The purpose of this study was to update our prior series at 10 years, with specific emphasis on survivorships free of re-revision for dislocation, any re-revision, and dislocation. We identified 300 revision THAs performed at a single tertiary care academic institution from 2011 to 2014. Aseptic loosening of the acetabular component (n=65), dislocation (n=59), and reimplantation as part of a two-stage exchange protocol (n=57) were the most common reasons for index revision. Dual-mobility constructs were used in 124 cases, and LFH were used in 176 cases. Mean age was 66 years, mean BMI was 31 kg/m2, and 45% were female. Mean follow-up was 7 years. The 10-year survivorship free of re-revision for dislocation was 97% in the MDM cohort and 91% in the LFH cohort with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 5.2; p=0.03). The 10-year survivorship free of any re-revision was 90% in the MDM cohort and 84% in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.5; p=0.04). The 10-year survivorship free of any dislocation was 92% in the MDM cohort and 87% in the LFH cohort. There was a trend towards an increased risk of any dislocation in the LFH cohort (HR 2.3; p=0.06). In this head-to-head comparison, revision THAs using MDM constructs had a significantly lower risk of re-revision for dislocation compared to LFH at 10 years. In addition, there was a trend towards lower risk of any dislocation. Level of Evidence: IV
Although data on uncemented short stems are available, studies on cemented short-stemmed THAs are limited. These cemented short stems may have inferior long-term outcomes and higher femoral component fracture rates. Hence, we examined the long-term follow-up of cemented short Exeter stems used in primary THA. Within the Exeter stem range, 7 stems have a stem length of 125 mm or less. These stems are often used in small patients, in young patients with a narrow femoral canal or patients with anatomical abnormalities. Based on our local database, we included 394 consecutive cemented stems used in primary THA (n=333 patients) with a stem length ≤125 mm implanted in our tertiary referral center between 1993 and December 2021. We used the Dutch Arthroplasty Registry (LROI) to complete and cross-check the data. Kaplan-Meier survival analyses were performed to determine 20-year survival rates with stem revision for any reason, for septic loosening, for aseptic loosening and for femoral component fracture as endpoints. The proportion of male patients was 21% (n=83). Median age at surgery was 42 years (interquartile range: 30–55). The main indication for primary THA was childhood hip diseases (51%). The 20-year stem survival rate of the short stem was 85.4% (95% CI: 73.9–92.0) for revision for any reason and 96.2% (95%CI: 90.5–98.5) for revision for septic loosening. No stems were revised for aseptic femoral loosening. However, there were 4 stem fractures at 6.6, 11.6, 16.5 and 18.2 years of follow-up. The stem survival with femoral component fracture as endpoint was 92.7% (CI: 78.5–97.6) at 20 years. Cemented short Exeter stems in primary THA show acceptable survival rates at long-term follow-up. Although femoral component fracture is a rare complication of a cemented short Exeter stem, orthopaedic surgeons should be aware of its incidence and possible risk factors.
Introduction. In 2010, a widely used metal-on-metal hip implant was voluntarily recalled from the market by the manufacturer. Our lab performed detailed retrieval analysis of 548 of the explanted devices and 165 periprosthetic tissue specimens. We reported a high degree of variability in the multiple measurements that we performed on the components, including volumetric wear. Other studies using semi-quantitative tissue grading methods to describe the histology of the periprosthetic tissues from metal-on-metal hips have looked for relationships between component wear and histological features. Grammatopoulos et al found higher ALVAL scores in 45 hip resurfacing patients with pseudotumors compared to 11 without pseudotumors and a moderately positive correlation between wear and the histological rankings for tissue necrosis and lymphocytic response. We examined correlations between the component wear measurements from retrieval analysis and the tissue features in this large group of one metal-on-metal hip design. Materials and Methods. Tissues were processed routinely into paraffin sections, stained with H&E and characterized with light microscopic semi-quantitative scores for ALVAL features and for the number of macrophages and lymphocytes, extent of metal debris and the estimated percentage of necrosis per slide. Spearman correlation analysis was conducted to evaluate any correlations between retrieval wear measurements and histological findings. Results. The median combined cup and ball wear volume was 17.5mm3 in these 165 cases. The median tissue ALVAL score was 5.5 out of 10. Component total wear volume was not predictive of the ALVAL score (P = 0.09, R = −0.007) or the number of lymphocytes (P= 0.170, R= −0.077) but there was a positive correlation between wear volume and the ranking for macrophages in the tissues (P< 0.001, R=0.215). No other correlations were found for component wear. The median time to revision was 4.84 years. There was a negative correlation between tissue inflammation ranking (P=0.002, R=−0.183) and for lymphocyte ranking and time to revision (P=0.003, R=−0.173). There was a positive correlation between time to revision and the macrophage ranking (P=0.005, R=0.166). Conclusion. From this large-scale retrieval analysis of one design of metal-on-metal