Aims. The aim of this study was to investigate the potentially increased risk of dislocation in patients with neurological disease who sustain a femoral neck fracture, as it is unclear whether they should undergo total hip arthroplasty (THA) or hemiarthroplasty (HA). A secondary aim was to investgate whether dual-mobility components confer a reduced risk of dislocation in these patients. Methods. We undertook a longitudinal cohort study linking the Swedish Hip Arthroplasty Register with the National Patient Register, including patients with a neurological disease presenting with a femoral neck fracture and treated with HA, a conventional THA (cTHA) with femoral head size of ≤ 32 mm, or a dual-mobility component THA (DMC-THA) between 2005 and 2014. The dislocation rate at one- and three-year revision, reoperation, and mortality rates were recorded. Cox multivariate regression models were fitted to calculate adjusted hazard ratios (HRs). Results. A
The primary aim was to assess whether patients waiting 6-months or more for a
Introduction.
Sacral tumours are rare and can present difficult diagnostic and therapeutic challenges even at an early diagnosis. Surgical resection margins have a reported prognostic role in local recurrence and improved survival. Successful management is achieved within a specialist multidisciplinary service and involves combination chemotherapy, radiotherapy and surgery. We present our experience of patients with sacral tumours referred to our unit, who underwent
Aims. Our aim was to analyse the long-term functional outcome of two
forms of surgical treatment for active patients aged >
70 years
with a displaced intracapsular fracture of the femoral neck. Patients
were randomised to be treated with either a hemiarthroplasty or
a total hip arthroplasty (THA). The outcome five years post-operatively
for this cohort has previously been reported. We present the outcome
at 12 years post-operatively. Patients and Methods. Initially 252 patients with a mean age of 81.1 years (70.2 to
95.6) were included, of whom 205 (81%) were women. A
The aim was to perform a cost-utility analysis of total joint replacement in the current environment. Arthritis is a disabling condition that leads to long-term deterioration in quality of life. Total joint replacement, despite being one of the greatest advances in medicine in the modern era, has come under recent scrutiny. The National Health Service (NHS) has competing demands and resource allocation is challenging in times of economic restraint. Patients undergoing
Introduction. Insufficient arthroscopic cuff tear reconstruction leading to massive osteoarthritis and irreparable rotator cuff tears might be salvaged by implantation of an inverted
Background. It is unclear which form of anaesthesia is the most favourable in primary total hip replacement (THR) surgery. A recently published systematic review of modern anaesthesia techniques in primary THR surgery (Macfarlane 2009) was not able to show any convincing benefit of regional or general anaesthesia. One retrospective study that examined anaesthesia and leg length (Sathappan 2008), found an increased incidence of leg length difference > 5 mm in those patients who were operated with regional anaesthesia. Our department used a mini invasive approach in supine as standard procedure in THR. The type of anaesthesia that is chosen is up to the individual anaesthetist. Purpose. We wanted to see if there was any correlation between type of anaesthesia and leg length,
Successful return to work (RTW) is a crucial outcome after primary total knee arthroplasty (TKA) in patients under 65 years old. We aimed to determine whether TKA facilitated RTW in patients <65 years, whose intention was to return preoperatively. We prospectively assessed 106 TKA patients under 65 years over a 1 year period both preoperatively and at 1 year following surgery. Patient demographics were collected including Oxford knee score, Oxford-APQ, VAS pain/health scores and EQ-5D. A novel questionnaire was distributed to delineate pre-operative employment status and post-operative intentions. This included questions on nature of pre and post-operative occupation, whether joint disease affected their ability to work and details of retirement plans and how this was affected by their knee. 69 patients intended to return to work following their TKA. Following arthroplasty, 57/69 patients (82.6%) returned to work at a mean of 16.4 weeks (SD 16.6). Univariate analysis showed significant factors facilitating RTW included, pre-operative oxford knee score, pre-operative Oxford-APQ score and pre-operative EQ-5D score. These were not predictive on multivariate analysis. This study finds that TKA facilitates return to work in 83% of those who intend to return to work following their surgery. This could have significant positive and health and financial cost implications for the individual, health system and society.
Many psychological factors have been associated with function after joint replacement. Personality is a stable pattern of responses to external conditions and stimuli. The aim of this study was to investigate the relationship between personality, joint function, and general physical in patients undergoing
Reduced length of stay (LOS) is logistically, economically and physiologically beneficial. Although a high proportion of total joint arthroplasty (TJA) patients are suitable for same day admission (SDA), removable barriers persist in many centres. This study aimed to determine factors limiting SDA and quantify the impact of implementing both SDA and a targeted enhanced recovery programme on length of stay. This single-centre retrospective cohort study collected data on elective TJA patients aged <60. Qualitative service reviews identified opportunities for optimisation. Improvements were implemented in 2017, including: obtaining consent at the pre-assessment clinic and robustly assessing suitability for SDA. A targeted rapid recovery program was implemented in June 2018. Data was collected prior to changes in 2017, and following changes in 2018. 106 of 108 screened patients were eligible for inclusion. There were no significant between-year differences in baseline health characteristics. Significantly greater proportions of 2018 patients were consented at their pre-assessment clinic (56% vs 8.9%, p<0.001) and assessed as suitable for SDA (94% vs 57.1%, p<0.001). Pre-operative LOS was significantly reduced in 2018 for both total hip replacements (median [IQR]: 0[0,0] vs 1[1,1], p<0.001) and total knee replacements (median [IQR]: 0[0,0] vs 0[0,1], p=0.002). The departmental mean LOS improved from 4.7 days to 3.7 days following SDA. This was further shortened to 3.2 days after introduction of the rapid recovery program. When a larger proportion of patients were deemed suitable for SDA, this correlated with reduction of LOS. The department now performs above national standards in both of these parameters.
In this review, we present the data of one of the largest non-designer, mid- to long-term follow ups of the AGC. We present a
Cephalasporin antibiotics have been commonly used for prophylaxis against surgical site infection. To prevent Clostridium difficile, the preferential use of agents such as flucloxacillin and gentamicin has been recommended. The aim of this study was to investigate the bone penetration of these antibiotics during hip and knee arthroplasty, and their efficacy against Staphylococcus aureus and S. epidermidis. Bone samples were collected from 21 patients undergoing total knee arthroplasty (TKA) and 18 patients undergoing total hip replacement (THA). The concentration of both antibiotics was analysed using high performance liquid chromatography. Penetration was expressed as a percentage of venous blood concentration. The efficacy against common infecting organisms was measured using the epidemiological cut-off value for resistance (ECOFF). The bone penetration of gentamicin was higher than flucloxacillin. The concentration of both antibiotics was higher in the acetabulum than the femoral head or neck (p=0.007 flucloxacillin; p=0.021 gentamicin). Flucloxacillin concentrations were effective against S. aureus and S. epidermis in all THAs and 20 (95%) TKAs. Gentamicin concentrations were effective against S.epidermis in all bone samples. Gentamicin was effective against S. aureus in 11 (89%) femoral samples. Effective concentrations of gentamicin against S. aureus were only achieved in 4 (19%) femoral and 6 (29%) tibial samples in TKA. Flucloxacillin and gentamicin was found to effectively penetrate bone during arthroplasty. Gentamicin was effective against S. epidermidis in both THA and TKA, while it was found to be less effective against S. aureus during TKA. Bone penetration of both antibiotics was less in TKA than THA.
Tranexamic Acid (TA) has been shown to reduce transfusion rates in Total Knee Replacement (TKR) without complication. In our unit it was added to our routine enhanced recovery protocol. No other changes were made to the protocol at this time and as such we sought to examine the effects of TA on wound complication and transfusion rate. All patients undergoing primary TKR over a 12 month period were identified. Notes and online records were reviewed to collate demographics, length of stay, use of TA, thromboprophylaxis, blood transfusion, wound complications and haemoglobin levels. All patients received a Columbus navigated TKR with a tourniquet. Only patients who received 14 days of Dalteparin for thromboprophylaxis were included. 124 patients were included, 72 receiving TA and 52 not. Mean age was 70. Four patients required a blood transfusion all of whom did not receive TA (p = 0.029). Mean change in Hb was 22 without TA and 21 with (p = 0.859). Mean length of stay was 6.83 days without Tranexamic Acid and 5.15 with (p < 0.001). 15% of patients (n=11) of the TA group had a wound complication, with 40% of patients (n=21) in the non TA group (p = 0.003). There was one ultrasound confirmed DVT (non TA group). No patients were diagnosed with pulmonary embolus. In our unit we have demonstrated a significantly lower transfusion rate, wound complication rate and length of stay, without any significant increase in thromboembolic disease with the use of TA in TKR.
INTRODUCTION. Cementless Total Hip Replacement surgery is a well established procedure for relative young patients with severe hip disease. Excellent long term clinical results have been published on the performance of the femoral component. With growing clinical experience, our concern focused on excessive wear of the Ultra High Molecular Weight Polyethylene (UHMWPE) ringloc liner of the Mallory Head cementless
The purpose of this study was to compare the clinical outcomes and complications following bilateral simultaneous total knee arthroplasty in high body mass index (BMI) patients(>30kg/m2) to those of patients with a BMI<30 kg/m2. Using data from an academic arthroplasty database and review of clinic charts we obtained health related quality of life (SF-12), and disease specific functional outcome scores (WOMAC or Oxford Knee Score). We also assessed length of hospital stay, ASA grade and transfusion requirements. Sixty six patients had a BMI<30 and 151 patients had a BMI>30.Introduction
Materials and Methods
This study assesses the incidence of noise in ceramic on ceramic (COC) bearings compared to metal on polyethylene (MOP) bearings. Noise after MOP implants has rarely been studied and they never been linked to squeaking. We have developed a noise characterising hip questionnaire and sent it along with the Oxford Hip Score (OHS) to 1000 patients; 509 respondents, 282 COC and 227 MOP; median age 63.7 (range 45–92), median follow up 2.9 years (range 6–156 months). 47 (17%) of the COC patients reported noise compared to 19 (8%) of the MOP patients (P=0.048). 9 COC and 4 MOP patients reported their hip noise as squeaking. We found the incidence of squeaking in the COC hips to be 3.2% compared to 1.8% in the MOP hips. Overall, 27% patients with noise reported avoiding recreational activities because of it and patient's with noisy hips scored on average 4 points less in the OHS (COC: P=0.04 and MOP: P =0.007). This is the first study to report squeaking from MOP hip replacements. We therefore believe the squeaking hip phenomenon is not exclusive to hard bearings. Surprisingly, only a small proportion of patients described nose from their as a ‘squeak’. Noisy hip implants may have social implications, and patients should be aware of this. We have shown a relationship between noise and a lower OHS. However, longer follow-up and further study is needed to link noise to a poorly functioning implant.
Hip wear simulation is a widely used technique for the pre-clinical evaluation of new bearing designs. However, wear rates seen in vitro can often be significantly different to those seen clinically. This can be attributed to the difference between the optimal conditions in a simulator and wide ranging conditions in real patients. This study aimed to develop more clinically relevant simulator tests, looking specifically at the effects of cup inclination angle (in vivo) and stop-dwell-start (SDS) protocols on a clinically available product. Five tests using a Paul type walking cycle (ISO 14242) were carried out on two ProSim hip simulators:
28mm MoM, standard walking, cup inclination 45°, (n = 5) 36mm MoM, standard walking, cup 45°, (n = 4) 36mm MOM, SDS: 10 walking cycles and pause of 5s with stance load of 1250N cup 45°, (n = 5) 36mm MOM, SDS: 10 walking cycles and pause of 30s with stance load of 1250N, (n = 5) cup 45° 36mm MOM, standard walking, cup 55°(n = 5), and 65°(n = 5). All samples had matched clearances, measured using a CMM (Prismo Navigator, Zeiss, Germany). Wear was measured gravimetrically (Sartorius ME235S: 0.01mg).Introduction
Method
Total hip replacements have been shown to give superior outcomes in patients with intracapsular fractures of the neck of femur compared with hemiarthroplasty. Collarless uncemented femoral stems give excellent long term results in elective hip replacements but there are few studies looking at their outcomes in fractured neck of femur patients. There is some concern that in trauma patients bone quality maybe inferior as most neck of femur fractures are secondary to osteoporosis. The presence of osteoporosis and subsequent widened femoral canal may compromise the mechanical stability of uncemented femoral stems and result in early subsidence, which can lead to altered leg length and decreased hip stability. The aim of this study was to assess whether early subsidence occurred when collarless uncemented stems were used to treat patients with fractures of the neck of femur. Post-operative radiographs of 33 patients, mean age 71, who underwent an uncemented collarless total hip replacement for a fracture, were reviewed. The distance from the calcar to the tip of the prosthesis was measured for each patient on the initial post operative radiograph and again on the follow-up radiograph at 6 months post operation. Any subsidence was recorded and magnification for each radiograph was calculated by measuring the diameter of the femoral head, which was known to be 36mm. Distances were then adjusted for magnification. The same procedure was performed on 36 age-matched patients, mean age 71, who underwent elective uncemented total hip replacements for osteoarthritis. Hospital notes for each patient were reviewed to assess for complications and DEXA scan results for trauma patients were also evaluated where available. The mean femoral stem subsidence was significantly greater in the fracture cohort than in elective patients (p = 0.001) with mean subsidence of 4.07mm (range 0.02–18.5mm) and 1.57mm (range 0–5.5mm) respectively. In the fracture cohort there were 3 revisions within 6 months of surgery, 1 for infection and 2 for femoral stem subsidence leading to dislocation. There were no revisions in the elective cohort. DEXA scan results were available for 21 of the 33 fracture cohort patients. All these patients had abnormal bone density with 52% being osteoporotic and 48% osteopenic. This study showed that collarless uncemented stems subsided significantly when performed for fractures and had a high early revision rate. We therefore recommend that cemented or collared femoral stems be used in patients with femoral neck fractures requiring total hip replacement to reduce the risk of femoral stem subsidence.
Background. Previous data from our institution show that more than half of all prosthetic joint infections are due to S. aureus. A significant proportion of these bacteria may have an endogenous source. Detecting and treating asymptomatic S. aureus nasal carriers preoperatively has been shown to reduce the risk of infection. Material and Methods. This is an ongoing prospective study that started in March/2009 and involves primary