Advertisement for orthosearch.org.uk
Results 1 - 20 of 1462
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 59 - 59
19 Aug 2024
Bakircioglu S Bulut MA Oral M Caglar O Atilla B Tokgozoglu AM
Full Access

Extensive and severe bone loss of the femur may be a result of a failed total hip arthroplasty (THA) or total knee arthroplasty (TKA) with multiple revision surgeries which may be caused by factors such as infection, periprosthetic fracture or osteolysis. The aim of this study was to assess outcomes of using the “Push-Through Total Femoral Prosthesis” (PTTF) for revision of a total hip replacement with extreme bone loss. Fourteen patients who had extensive bone defects of the femur due to failed THR's and were treated with PTTF between 2012 and 2020 were included in this study. Primary functional outcomes were assessed using Harris Hip Score (HHS), Toronto Extremity Salvage Score (TESS) and Musculoskeletal Tumor Society (MSTS) scores. Range of motion, complications, and ambulatory status were also recorded to assess secondary outcomes. Two of 14 patients underwent surgery with PTTF for both knee and hip arthroplasty revision. The mean time between index surgery and PTTF was 15 years (3 to 32 yrs.). Acetabular components were revised in six of 14 patients. After a mean follow-up of 5.9 years, hip dislocations occurred in 3 patients. All dislocated hips were in patients with retained non-constrained acetabular bearings. Patient satisfaction was high (MSTS: 67%, HHS: 61.2%, TESS 64.6%) despite a high re-operation rate and minor postoperative problems. PTTF is a unique alternative that may be considered for a failed THA revision procedure in patients with an extreme femoral bone defect. Patients are able to ambulate pain free relatively well. Routine usage of constrained liners should be considered to avoid hip dislocation which was our main problem following the procedure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 5 - 5
7 Jun 2023
Prakash R Abid H Wasim A Sharma A Agrawal Y
Full Access

The National Health Service produces over 500,000 tonnes of waste and 25 mega tonnes of CO2 annually. Operating room waste is segregated into different streams which are recycled, disposed of in landfill sites, or undergo costly and energy-intensive incineration processes. By assessing the quantity and recyclability of waste from primary hip and knee arthroplasty cases, we aim to identify strategies to reduce the carbon footprint of arthroplasty surgery. Data was collected prospectively at a tertiary orthopaedic hospital, in the theatres of six arthroplasty surgeons between April – July 2022. Fifteen primary total hip arthroplasty (THA) and 16 primary total knee arthroplasty (TKA) cases were included; revision and complex primary cases were excluded. Waste was categorised into non-hazardous waste, hazardous waste, recycling, sharps, and linens. Each waste category was weighed. Items disposed as non-hazardous waste were catalogued for a sample of 10 TKA and 10 THA cases. Recyclability of items was determined from packaging. Average total waste generated for THA and TKA were 14.46kg and 17.16kg respectively, with TKA generating significantly greater waste (p < 0.05). On average only 5.4% of waste was recycled in TKA and just 2.9% in THA cases. The mean recycled waste was significantly greater in TKA cases compared to THA, 0.93kg and 0.42kg respectively (p < 0.05). Hazardous waste represented the largest proportion of the waste streams for both TKA (69.2%) and THA (73.4%). On average TKA generated a significantly greater amount (11.87kg) compared to THA (10.61kg), p < 0.05. Non-hazardous waste made up 15.1% and 11.3% of total waste for TKA and THA respectively. In the non-hazardous waste, only two items (scrub brush packaging and sterile towel packaging) were identified as recyclable based on packaging. We estimate that annually total hip and knee arthroplasty generates over 2.7 million kg of waste in the UK. Through increased use of recyclable plastics for packaging, combined with clear labelling of items as recyclable, medical suppliers can significantly reduce the carbon footprint of arthroplasty. Our data highlight only a very small percentage of waste is recycled in total hip and knee arthroplasty cases


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 22 - 22
2 May 2024
Logishetty K Whitwell D Palmer A Gundle R Gibbons M Taylor A Kendrick B
Full Access

There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up. This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA, implant survivorship, clinical outcomes, and indications for re-operation. A total of 39 TFAs were performed in 38 patients between 2015–2018 (median age 68 years, IQR 17, range 46–86), with 5.3 years’ (IQR 1.2, 4.1–18.8) follow-up; 3 patients had died. The most common indication (30/39, 77%) for TFA was periprosthetic joint infection (PJI) or fracture-related infection (FRI); and 23/39 (59%) had a prior periprosthetic fracture (PPF). TFA was performed with dual-mobility or constrained cups in 31/39 (79%) patients. Within the cohort, 12 TFAs (31%) required subsequent revision surgery: infection (7 TFAs, 18%) and instability (5 TFAs, 13%) were the most common indications. 90% of patients were ambulatory post-TFA; 2 patients required disarticulation due to recurrent PJI. While 31/39 (79%) were infection free at last follow-up, the remainder required long-term suppressive antibiotics. This is the largest series of TFA for non-oncological indications. Though TFA has inherent risks of instability and infection, most patients are ambulant after surgery. Patients should be counselled on the risk of life-long antibiotics, or disarticulation when TFA fails


Bone & Joint Open
Vol. 4, Issue 5 | Pages 385 - 392
24 May 2023
Turgeon TR Hedden DR Bohm ER Burnell CD

Aims. Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design. Methods. Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m. 2. (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds. Results. Mean acetabular subsidence from baseline to 24 months was 0.087 mm (SD 0.152), below the critical threshold of 0.2 mm (p = 0.005). Mean femoral subsidence from baseline to 24 months was -0.002 mm (SD 0.194), below the published reference of 0.5 mm (p < 0.001). There was significant improvement in patient-reported outcome measures at 24 months with good to excellent results. Conclusion. RSA analysis demonstrates excellent fixation with a predicted low risk of revision at ten years of this novel reverse total hip system. Clinical outcomes were consistent with safe and effective hip replacement prostheses. Cite this article: Bone Jt Open 2023;4(5):385–392


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 12 - 12
7 Jun 2023
Qayum K Ng Z Sudarshan V Kudhail K Sapra H Guerero D Daoub A
Full Access

Patients undergoing total hip or knee arthroplasty (THA/TKA) are commonly associated with high pain scores and narcotic use. Duloxetine is effective in relieving chronic pain. The aim of this study was to evaluate the safety and efficacy of duloxetine for pain management following THA/TKA. Five major databases (PubMed, Embase, Scopus, Cochrane, and Web of Science) were searched for randomised controlled trials (RCTs) that compared duloxetine to placebo in patients that underwent THA/TKA. The primary outcome was pain reduction with rest and movement at short-term and long-term time intervals. Secondary outcomes were the use of analgesics, length of stay, and safety profile. The risk of bias was assessed using the Cochrane tool. Data were pooled using RevMan 5.4. The results were reported as mean difference (MD) or standardised MD (SMD) and 95% confidence intervals (CI). Eight RCTs with 767 patients were included. 50.2% (n=385/767) of patients received duloxetine. After one day, duloxetine was superior to the control regarding pain reduction with rest (SMD= −0.22 [−0.41, −0.03], p=0.02) after sensitivity analysis and pain reduction at movement (SMD= −0.39 [−0.55, −0.24], p<0.001). Similarly, after 12 weeks, duloxetine significantly reduced pain with rest (SMD= −0.3 [−0.52, −0.09], p=0.006) and pain with movement (SMD= −0.52 [−0.87, −0.17], p=0.003). In addition, after sensitivity analysis, duloxetine was associated with less analgesic use after one day (MD= −4.65 [−7.3, −2.01], p<0.001) and two days (MD= −5.65 [−10.62, −0.67], p=0.03). Patients who received duloxetine also required fewer analgesics after three days. However, there was no significant difference between the duloxetine and control groups in analgesic use after one week, length of stay, and adverse events. Duloxetine was superior to the placebo regarding short-term and long-term pain reduction with rest and movement following THA/TKA. Duloxetine reduced postoperative analgesic use. There was no significant difference between duloxetine and placebo regarding adverse events and length of stay


Aims. Delirium is associated with adverse outcomes following hip fracture, but the prevalence and significance of delirium for the prognosis and ongoing rehabilitation needs of patients admitted from home is less well studied. Here, we analyzed relationships between delirium in patients admitted from home with 1) mortality; 2) total length of hospital stay; 3) need for post-acute inpatient rehabilitation; and 4) hospital readmission within 180 days. Methods. This observational study used routine clinical data in a consecutive sample of hip fracture patients aged ≥ 50 years admitted to a single large trauma centre during the COVID-19 pandemic between 1 March 2020 and 30 November 2021. Delirium was prospectively assessed as part of routine care by the 4 A’s Test (4AT), with most assessments performed in the emergency department. Associations were determined using logistic regression adjusted for age, sex, Scottish Index of Multiple Deprivation quintile, COVID-19 infection within 30 days, and American Society of Anesthesiologists grade. Results. A total of 1,821 patients were admitted, with 1,383 (mean age 79.5 years; 72.1% female) directly from home. Overall, 87 patients (4.8%) were excluded due to missing 4AT scores. Delirium prevalence in the whole cohort was 26.5% (460/1,734): 14.1% (189/1,340) in the subgroup of patients admitted from home, and 68.8% (271/394) in the remaining patients (comprising care home residents and inpatients when fracture occurred). In patients admitted from home, delirium was associated with a 20-day longer total length of stay (p < 0.001). In multivariable analyses, delirium was associated with higher mortality at 180 days (odds ratio (OR) 1.69 (95% confidence interval (CI) 1.13 to 2.54); p = 0.013), requirement for post-acute inpatient rehabilitation (OR 2.80 (95% CI 1.97 to 3.96); p < 0.001), and readmission to hospital within 180 days (OR 1.79 (95% CI 1.02 to 3.15); p = 0.041). Conclusion. Delirium affects one in seven patients with a hip fracture admitted directly from home, and is associated with adverse outcomes in these patients. Delirium assessment and effective management should be a mandatory part of standard hip fracture care. Cite this article: Bone Jt Open 2023;4(6):447–456


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 8 - 8
19 Aug 2024
Kärrholm J Itayem R Angelomenos V Mohaddes M Rogmark C Rolfson O
Full Access

In 2022, approximately 60% of inserted cups and stems in Sweden utilized cemented fixation. Two predominant brands, Refobacin Bone Cement R and Palacos R+G, both incorporating gentamicin, were employed in over 90% of primary cemented Total Hip Arthroplasties (THAs) between 2012 and 2022. This study investigates whether the choice between these cement types affects the risk of revision. The five most frequently used cemented cups and the three most common stems were studied. Inclusion criteria encompassed hips with non-tumour diagnoses, operated through a direct lateral or posterior incision, featuring a 28–36 mm metal or ceramic head. Outcomes were assessed for cup revisions (n=55,457 Refobacin, 37,210 Palacos), stem revisions (n=51,732 Refobacin, 30,018 Palacos), and all-cemented THAs with either brand (n=45,265 Refobacin, 26,347 Palacos). Kaplan-Meier life tables and hazard ratios (HR) utilizing Cox regression were computed, adjusting for age, sex, diagnosis, implant type, femoral head size, and material. Over a 10-year period, the cumulative percent revision with Refobacin was consistently higher than Palacos in all three analyses (cups: Refobacin 2.4 (2.3–2.5), Palacos 2.1 (2.0–2.2); stems: Refobacin 2.6 (2.5–2.7), Palacos 2.1 (2,0–2,2); all-cemented: Refobacin 3.2 (2.9–3.5), Palacos 2.9 (2.6–3.2)). Both unadjusted and adjusted HR were 13–25% lower with Palacos. In the analysis of all-cemented THAs, the adjusted HR for Palacos was 0.85 (0.76–0.95). Separating revisions into infectious and non-infectious reasons revealed a lower risk of infectious revisions with Palacos in all three analyses (all-cemented: adjusted HR infection 0.66 (0.56–0.78); non-infectious 1.10 (0.94–1.28)). Hips cemented with Refobacin may face an increased risk of infection, potentially due to a smaller release of antibiotics into surrounding tissues. Unaccounted factors like different mixing systems or unknown biases could also influence outcomes, emphasizing the need for further investigation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 78 - 78
19 Aug 2024
Holland CT Leal J Easley ME Nunley JA Ryan SP Bolognesi MP Wellman SS Jiranek WA
Full Access

This study evaluates patient reported outcome measurement information system (PROMIS) scores after total hip arthroplasty (THA) and total ankle arthroplasty (TAA) in matched cohorts, while simultaneously evaluating implant survivorship and 90-day hospital utilization. It is hypothesized that while both procedures would yield similar PROMIS score improvements, THA would demonstrate superior mid-term implant survivorship.

Primary THA and TAA patients from 2015–2022 with minimum one-year follow-up were retrospectively reviewed. After applying exclusion criteria, 2,092 THAs and 478 TAAs were included for analysis. Demographics, pre- and post-operative patient reported outcome measures (PROMs), revision surgeries, ED visits, and re-admissions were collected. THA and TAA patients were then propensity score matched at 2:1 ratio for age, sex, race, BMI, ASA, and comorbidities, resulting in a final cohort of 844 THAs and 455 TAAs for comparison.

There were similar pre-operative PROMIS Pain Interference (PI) scores between THA and TAA, with both showing improvement at six weeks. However, THA patients exhibited lower PI scores at one year (53.0 versus 54.0; p=0.009). Pre-operative PROMIS Physical Function (PF) was worse in THA patients but showed greater improvement compared to TAA patients at both six weeks (p<0.001) and one year (p<0.001). Pre-operative PROMIS depression scores were similar and improved similarly in both groups. Joint-specific PROMs (HOOS for THA and FAAM for TAA) improved in both cohorts. THA demonstrated superior survivorship free of all-cause revision at five years compared to TAA (95% versus 77%; p<0.0001).

Patients undergoing THA or TAA experienced significant improvements in their general and joint-specific PROMs post-operatively. However, patients undergoing THA demonstrated higher PROMIS PI and PF scores at one-year when compared to TAA, as well as improved survivorship. Generic PRO instruments enable comparison of medical treatments in different anatomic sites to the patients overall health.


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 103 - 110
1 Jul 2021
Chalmers BP Lebowitz JS Chiu Y Joseph AD Padgett DE Bostrom MPG Gonzalez Della Valle A

Aims. Due to the opioid epidemic in the USA, our service progressively decreased the number of opioid tablets prescribed at discharge after primary hip (THA) and knee (TKA) arthroplasty. The goal of this study was to analyze the effect on total morphine milligram equivalents (MMEs) prescribed and post-discharge opioid repeat prescriptions. Methods. We retrospectively reviewed 19,428 patients undergoing a primary THA or TKA between 1 February 2016 and 31 December 2019. Two reductions in the number of opioid tablets prescribed at discharge were implemented over this time; as such, we analyzed three periods (P1, P2, and P3) with different routine discharge MME (750, 520, and 320 MMEs, respectively). We investigated 90-day refill rates, refill MMEs, and whether discharge MMEs were associated with represcribing in a multivariate model. Results. A discharge prescription of < 400 MMEs was not a risk factor for opioid represcribing in the entire population (p = 0.772) or in opioid-naïve patients alone (p = 0.272). Procedure type was the most significant risk factor for narcotic represcribing, with unilateral TKA (hazard ratio (HR) = 5.62), bilateral TKA (HR = 6.32), and bilateral unicompartmental knee arthroplasty (UKA) (HR = 5.29) (all p < 0.001) being the highest risk for refills. For these three procedures, there was approximately a 5% to 6% increase in refills from P1 to P3 (p < 0.001); however, there was no significant increase in refill rates after any hip arthroplasty procedures. Total MMEs prescribed were significantly reduced from P1 to P3 (p < 0.001), leading to the equivalent of nearly 500,000 fewer oxycodone 5 mg tablets prescribed. Conclusion. Decreasing opioids prescribed at discharge led to a statistically significant reduction in total MMEs prescribed. While the represcribing rate did not increase for any hip arthroplasty procedure, the overall refill rates increased by about 5% for most knee arthroplasty procedures. As such, we are now probably prescribing an appropriate amount of opioids at discharge for knee arthroplasty procedure, but further reductions may be possible for hip arthroplasty procedures. Cite this article: Bone Joint J 2021;103-B(7 Supple B):103–110


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 54 - 54
1 Oct 2020
Freiman S Schwabe M Pashos G Barrack RL Nunley R Adelani M Pascual-Garrido C Clohisy J Lawrie C
Full Access

Introduction. The purpose of the study was to determine access to and, ability to use telemedicine technology in an adult hip and knee reconstruction patient population and we seek to understand these patients' perceived benefits, risks and preferences of telemedicine. Methods. We performed a cross-sectional telephone administered survey on patients scheduled to undergo primary THA and TKA by one of six surgeons at a single academic institution between March 23 and June 2, 2020. Results. 163 patients were contacted and 113 (69.3%) completed the survey. Of the patients that completed surveys, 88% of patients reported using the internet with 94% reporting owning a device capable of videoconferencing. 78% of patients had participated in a video call in the past year and 37% having done a video visit with their physician. When asked for their preferred method for a physician visit, 80% ranked in-person as their first choice, followed by 18% preferring a video visit. Perceived benefits of telemedicine visits included reduced travel to appointments (87% agree or strongly agree) and reduced cost of attending appointments (63% agree or strongly agree). However, patients were concerned that they would not establish the same patient-physician connection (51% agree or strongly agree) and would not receive the same level of care (33% agree or strongly agree) through telemedicine visits versus in person visits. Conclusion. The majority of total hip and knee arthroplasty patients have access to and are capable of using the technology required for telemedicine visits. However, patients still prefer to have in person visit over concern that they will not establish the same patient-physician connection and will not receive the same level of care, despite benefits of reduced time spent traveling to and cost of attending appointments, and making it easier to attend appointments


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 52 - 52
2 May 2024
Bayram JM Wickramasinghe N Scott CE Clement ND
Full Access

The aims were to assess whether preoperative joint-specific function (JSF) and health-related quality of life (HRQoL) were associated with level of clinical frailty in patients waiting for a primary total hip arthroplasty (THA) or knee arthroplasty (KA).

Patients waiting for a THA (n=100) or KA (n=100) for more than six months were prospectively recruited from the study centre. Overall, 162 patients responded to the questionnaire (81 THA; 81 KA). Patient demographics, Oxford score, EuroQol five dimension (EQ-5D) score, EuroQol visual analogue score (EQ-VAS), Rockwood Clinical Frailty Score (CFS), and time spent on the waiting list were collected.

There was a significant correlation between CFS and the Oxford score (THA r=ˆ’0.838; p<0.001, KA r=ˆ’0.867; p<0.001), EQ-5D index (THA r=ˆ’0.663, p<0.001; KA r=ˆ’0.681; p< 0.001), and EQ-VAS (THA r=ˆ’0.414; p<0.001, KA r=ˆ’0.386; p<0.001). Confounding variables (demographics and waiting time) where adjusted for using multiple regression analysis. For each 8.5 (THA, 95% CI 7.1 to 10.0; p<0.001) and 9.9 (KA, 95% CI 8.4 to 11.4; p<0.001) point change in the Oxford score, there was an associated change in level of the CFS. For each 0.16 (THA, 95% CI 0.10 to 0.22; p<0.001) and 0.20 (KA, 95% CI 0.12 to 0.27; p<0.001) utility change in EQ-5D, there was an associated change in level of the CFS. EQ-VAS (THA, B=ˆ’11.5; p<0.001, KA B=ˆ’7.9; p=0.005) was also associated with CFS.

JSF and HRQoL in patients awaiting THA or KA for more than six months, were independently associated with level of clinical frailty. With further prospective studies, clinical frailty may prove to be a useful metric to assist in the prioritization of arthroplasty waiting lists.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 48 - 48
23 Jun 2023
Carender CN Perry KI Sierra RJ Trousdale RT Berry DJ Abdel MP
Full Access

There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate implant survivorship, radiographic results, and clinical outcomes in a large cohort of reimplantation THAs using MFT stems.

We identified 236 reimplantation THAs from a single tertiary care academic institution from 2000 to 2020. Two designs of MFT stems were used as part of an established two-stage exchange protocol for the treatment of PJI. Mean age at reimplantation was 65 years, mean BMI was 32 kg/m2, and 46% were female. Median stem diameter was 19 mm, and median stem length was 195 mm. Mean follow-up was 7 years. A competing risk model accounting for death was utilized.

The 15-year cumulative incidence of any revision was 24%. There were 48 revisions, with the most common reasons being dislocation (n=25) and PJI (n=16). The 15-year cumulative incidence of any reoperation was 28%. Only 13 revisions involved the fluted tapered portion of the component (FTC), for a 15-year cumulative incidence of any FTC revision of 8%. Only 2 FTCs were revised for aseptic loosening, resulting in a 15-year cumulative incidence of FTC revision for aseptic loosening of 1%. Stem subsidence >5 mm occurred in 2% of unrevised cases, and all stems were radiographically stable at most recent follow-up. Mean HHS was 77 at most recent follow-up.

This series demonstrated that MFT stems were durable and reliable even in the setting of two-stage reimplantation for infection. While the incidence of aseptic loosening was very low, the incidence of any revision was 24% at 15 years, primarily caused by dislocation and recurrent PJI.

Level of Evidence: IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 31 - 31
7 Jun 2023
Asopa V Womersley A Wehbe J Spence C Harris P Sochart D Tucker K Field R
Full Access

Over 8000 total hip arthroplasties (THA) in the UK were revised in 2019, half for aseptic loosening. It is believed that Artificial Intelligence (AI) could identify or predict failing THA and result in early recognition of poorly performing implants and reduce patient suffering.

The aim of this study is to investigate whether Artificial Intelligence based machine learning (ML) / Deep Learning (DL) techniques can train an algorithm to identify and/or predict failing uncemented THA.

Consent was sought from patients followed up in a single design, uncemented THA implant surveillance study (2010–2021). Oxford hip scores and radiographs were collected at yearly intervals. Radiographs were analysed by 3 observers for presence of markers of implant loosening/failure: periprosthetic lucency, cortical hypertrophy, and pedestal formation.

DL using the RGB ResNet 18 model, with images entered chronologically, was trained according to revision status and radiographic features. Data augmentation and cross validation were used to increase the available training data, reduce bias, and improve verification of results.

184 patients consented to inclusion. 6 (3.2%) patients were revised for aseptic loosening. 2097 radiographs were analysed: 21 (11.4%) patients had three radiographic features of failure.

166 patients were used for ML algorithm testing of 3 scenarios to detect those who were revised. 1) The use of revision as an end point was associated with increased variability in accuracy. The area under the curve (AUC) was 23–97%. 2) Using 2/3 radiographic features associated with failure was associated with improved results, AUC: 75–100%. 3) Using 3/3 radiographic features, had less variability, reduced AUC of 73%, but 5/6 patients who had been revised were identified (total 66 identified).

The best algorithm identified the greatest number of revised hips (5/6), predicting failure 2–8 years before revision, before all radiographic features were visible and before a significant fall in the Oxford Hip score. True-Positive: 0.77, False Positive: 0.29.

ML algorithms can identify failing THA before visible features on radiographs or before PROM scores deteriorate. This is an important finding that could identify failing THA early.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 18 - 18
1 Nov 2021
Sedel L Bizot P Garcia-Cimbrelo E
Full Access

Fracture risks are the most common argument against the use of Ceramic on ceramic (CoC) hip implants. Question: is ceramic material at risk in case of severe local trauma?

Over a long period, we tried to identify patients with a CoC prosthesis (Ceraver Osteal°)who did sustain a trauma. This was conducted in three different institutions.

Eleven patients were found: 9 males and 2 females aged 17 to 70 years at time of index surgery. Accident occurred 6 months to 15 years after index: one car accident, five motorcycle accident, five significant trauma after a fall, including one ski board accident. Consequences of these trauma were: six fractures of the acetabulum with socket loosening in 4 that needed revision, two femoral shaft fracture, one orifed and one stem exchanged, one traumatic hip dislocation associated to loosening of the socket revised at 10 years, and one traumatic loosening of the socket. Ten had no consequence on ceramic integrity. One experienced a fracture of the patella from a dashboard trauma, a liner shipping was discovered during socket revision 2 years later. This is the only case of possible relation between trauma and ceramic fracture. In a more recent longitudinal study on 1856 CoC prosthesis performed from 2010 to 2021, 29 severe traumas were identified with no consequence on Ceramic material.

From this limited case study, it can be assumed that Pure Alumina Ceramic well designed and manufactured, will not break after a significant trauma.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 43 - 43
23 Jun 2023
Carender CN Taunton MJ Fruth KM Pagnano MW Abdel MP
Full Access

There is a paucity of mid-term data on modular dual-mobility (MDM) constructs versus large (≥40 mm) femoral heads (LFH) in revision total hip arthroplasties (THAs). The purpose of this study was to update our prior series at 10 years, with specific emphasis on survivorships free of re-revision for dislocation, any re-revision, and dislocation.

We identified 300 revision THAs performed at a single tertiary care academic institution from 2011 to 2014. Aseptic loosening of the acetabular component (n=65), dislocation (n=59), and reimplantation as part of a two-stage exchange protocol (n=57) were the most common reasons for index revision. Dual-mobility constructs were used in 124 cases, and LFH were used in 176 cases. Mean age was 66 years, mean BMI was 31 kg/m2, and 45% were female. Mean follow-up was 7 years.

The 10-year survivorship free of re-revision for dislocation was 97% in the MDM cohort and 91% in the LFH cohort with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 5.2; p=0.03). The 10-year survivorship free of any re-revision was 90% in the MDM cohort and 84% in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.5; p=0.04). The 10-year survivorship free of any dislocation was 92% in the MDM cohort and 87% in the LFH cohort. There was a trend towards an increased risk of any dislocation in the LFH cohort (HR 2.3; p=0.06).

In this head-to-head comparison, revision THAs using MDM constructs had a significantly lower risk of re-revision for dislocation compared to LFH at 10 years. In addition, there was a trend towards lower risk of any dislocation.

Level of Evidence: IV


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 17 - 17
23 Jun 2023
Schreurs BW van Veghel MH van der Koelen RE Hannink G Rijnen WH
Full Access

Although data on uncemented short stems are available, studies on cemented short-stemmed THAs are limited. These cemented short stems may have inferior long-term outcomes and higher femoral component fracture rates. Hence, we examined the long-term follow-up of cemented short Exeter stems used in primary THA.

Within the Exeter stem range, 7 stems have a stem length of 125 mm or less. These stems are often used in small patients, in young patients with a narrow femoral canal or patients with anatomical abnormalities. Based on our local database, we included 394 consecutive cemented stems used in primary THA (n=333 patients) with a stem length ≤125 mm implanted in our tertiary referral center between 1993 and December 2021. We used the Dutch Arthroplasty Registry (LROI) to complete and cross-check the data. Kaplan-Meier survival analyses were performed to determine 20-year survival rates with stem revision for any reason, for septic loosening, for aseptic loosening and for femoral component fracture as endpoints.

The proportion of male patients was 21% (n=83). Median age at surgery was 42 years (interquartile range: 30–55). The main indication for primary THA was childhood hip diseases (51%). The 20-year stem survival rate of the short stem was 85.4% (95% CI: 73.9–92.0) for revision for any reason and 96.2% (95%CI: 90.5–98.5) for revision for septic loosening. No stems were revised for aseptic femoral loosening. However, there were 4 stem fractures at 6.6, 11.6, 16.5 and 18.2 years of follow-up. The stem survival with femoral component fracture as endpoint was 92.7% (CI: 78.5–97.6) at 20 years.

Cemented short Exeter stems in primary THA show acceptable survival rates at long-term follow-up. Although femoral component fracture is a rare complication of a cemented short Exeter stem, orthopaedic surgeons should be aware of its incidence and possible risk factors.


Full Access

Arthroplasty has consistently shown ‘beneficial and often dramatic improvements in quality of life'. In developed healthcare systems arthroplasty has evolved to minimised complications through evidence-based implant selection, rigorous infection control and high volume training. The Children's Surgical Centre has performed 256 THAs since 2007, We aim to assess the outcome of arthroplasty in a LMIC. Our primary outcome was all cause of re-operation and our secondary outcome was any complications not requiring return to theatre. A retrospective review of all consecutive THA since 2007 was conducted. Electronic and physical case notes were reviewed and basic demographics, indication for THA, risk factors for complications, implant combinations and complications were recorded. Statistical analysis was performed using MedCalc. A total of 256 THA were identified in 225 patients. The mean age was 43, with a M2:1F ratio. The most common pathologies were (1)AVN (44%), (2)OA (11%) and (3)DDH (11%). Revision rate was 13%. The mean time from implantation to revision was 2.8 years (0–9). The most common reasons for revision were (1)stem fracture (5.8%), (2)aseptic loosening (4.8%) and (3)infection (2.7%). Six different stems have been use over the time period. The best surviving were the Zimmer ML Taper and the UMA Muller stems. The UMA C-Stem was the worst performing which suffered 100% stem fracture. 109 complications were identified in 85 patients (33.2%). The three most common complications were (1)aseptic loosening (10.5%) (2)stem fracture (5.8%) and (3)dislocation (5.8%). Previous surgery (n=44) was found to be a significant risk for complications but not infection. OHS initially improved but began to decline after year 3. Patients present to CSC with neglected hip pathology, disability and significant pre-operative deformity. These patients benefit from THA and the initially high complication rates at CSC are declining suggesting the apex of the ‘learning curve' has passed. Cheap poorly manufactured implants continue to cause catastrophic failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 42 - 42
23 Jun 2023
Lustig S Cotte M Foissey C Asirvatham R Servien E Batailler C
Full Access

The benefit of dual mobility cup (DMC) for primary total hip arthroplasties (THA) is still controversial. This study aimed to compare 1) the complications rate, 2) the revisions rate, 3) the survival rate after monobloc DMC compared to large femoral heads (LFH) in primary THA.

Between 2010 and 2019, 2,075 primary THA using cementless DMC or LFH were included. Indications for DMC were patients older than 70 years old or with high risk of dislocation. Every other patient received a LFH. Exclusion criteria were cemented implants, femoral neck fracture, a follow-up of less than one year. 1,940 THA were analyzed: 1,149 DMC (59.2%), 791 LFH (40.8%). The mean age was 73 ±9.2 years old in DMC group and 57 ±12 in LFH group. The complications and the revisions have been assessed retrospectively.

The mean follow-up was 41.9 months ±14 [12–134]. There were significantly fewer dislocations in DMC group (n=2; 0.17%) compared to LFH group (n=8; 1%) (p=0.019). The femoral head size had no impact on the dislocations rate in LFH group (p=0.70). The overall complication rate in DMC (n=59; 5.1%) and LFH (n=53; 6.7%) were not statistically different (p=0.21). No specific complication was attributed to the DMC. In DMC group, 18 THA (1.6%) were revised versus 15 THA in LFH group (1.9%) (p= 0.71). There was no statistical difference for any cause of revisions in both groups. The cup aseptic revision-free survival rates at 5 years were 98% in DMC group and 97.3% in LFH group (p=0.78).

Monobloc DMC had a lower risk of dislocation in a high-risk population than LFH in a low-risk population at the mid-term follow-up. There was no significant risk of specific complications or revisions for DMC in a large cohort. Monobloc DMC can be safely used in a selected high-risk population.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 19 - 19
1 Nov 2021
Schreurs B Kuijpers M van Steenbergen L Hannink G
Full Access

The increasing number of total hip arthroplasty (THA) used in young patients will inevitably lead to more revision procedures at younger ages, especially since the outcome of primary THA in young patients is already inferior compared to older patients. However, these data are lacking in literature. The aim of this study was to determine the survival of both acetabular and femoral components placed during primary and revision hip arthroplasty in patients under 55 years using Dutch Arthroplasty Register (LROI) data. All primary THA registered in the LROI between 2007–2018 in patients under 55 years were selected (n=25,682). Subsequent cup- and stem revision procedures were included. Kaplan-Meier survival analyses were used to estimate the survival probability of primary and revised cup- and stem components. Mean follow-up of primary cups and stems was 5.8 years (SD 3.2) and 5.9 years (SD 3.2), respectively. In total, 659 cup revision procedures and 532 stem revision procedures were registered. Most common reason for cup revision was acetabular loosening (n=163), most common reason for stem revision was femoral loosening (n=202). Primary cup survival for any reason at 10 years follow-up was 96.1% (95%CI: 95.7–96.4). For primary stems, 10 year survival for any reason was 97.1% (95%CI: 96.7–97.3). Mean follow-up of all revision procedures was 4.1 years (SD 2.9). Out of 659 cup revisions, 113 cup re-revisions were registered. Survival of revised cups, with end-point cup re-revision for any reason was 82.2% (95%CI: 78.8–85.1) at 5 years follow-up. Out of 532 stem revisions, 89 stem re-revisions were registered. For revised stems, survival at 5 year follow-up, with endpoint stem re-revision for any reason was 82.0% (95%CI: 78.2–85.2). The outcome of revised acetabular and femoral components is worrisome, with a survival of 82% at 5 years follow-up. This information is valuable to provide realistic expectations for these young patients at time of primary THA


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 38 - 38
1 Oct 2019
Stevenson K Fryhofer G Lopez VMS Koressel J Hume E Nelson CL
Full Access

Introduction. The obesity epidemic is a growing problem and must be considered with the projected increased demand for total hip arthroplasty (THA). Previous studies have reported increased complication rates after THA in the obese population, which has led to hesitation in offering surgery to this population. Moreover, some insurers are denying coverage for morbidly obese patients. While many consider obesity a “modifiable” risk factor, very few patients with advanced osteoarthritis have successfully lost substantial weight. The experience of centers that utilize systematic preoperative risk stratification tools and standardized postoperative total joint pathways may be underrepresented in prior studies. The aim of this study is to describe one surgeon's experience performing THA in morbidly and super-obese patient populations using an institutional preoperative Risk Stratification Tool (RST) and total joints pathway. Methods. We conducted a retrospective review of patients undergoing primary THA between May 2014 and December 2017 performed by a single surgeon at a tertiary care referral center. All patients were assessed preoperatively using an institutional RST and had a minimum of 90-day postoperative follow up. Patients were stratified by body mass index (BMI, kg/m. 2. ): non-obese (BMI < 30), obese (30–34), severely obese (35–39), morbidly obese (40–44), and super-obese (≥ 45). Primary outcomes were inpatient and 90-day complications. Continuous and binary parameters were analyzed by Kruskal-Wallis and Fisher exact tests. Logistic regression was additionally utilized to evaluate outcomes by BMI cohort. Results. A consecutive series of 368 patients met inclusion criteria across all BMI cohorts. There was significant variation with respect to age (P=0.001), BMI (P<0.001), diabetes (P=0.008), ASA class (P<0.001), and anesthesia type (P=0.003) (Table 1). Variation among BMI cohorts was also identified for several operative and postoperative parameters, including longer operative and in-room time and greater length of stay (P<0.001) (Table 2). Compared to non-obese patients, super-obese patients had 20.1 greater odds of return to OR within 90 days for superficial surgical site infection (SSI) or prolonged round drainage (P=0.008) (Table 3). Notably, morbidly and super-obese patients were not at significantly increased risk for inpatient intensive care unit (ICU) transfer, blood transfusion, 90-day emergency room visit, or 90-day readmission compared to their non-obese counterparts. For patients in whom 1-year follow-up was available, these differences between BMI cohorts remained insignificant. Conclusions. Patients with BMI>40 are more likely than non-obese patients to have increased postoperative rehabilitation needs but are not at increased risk for in-hospital complications. Super-obese patients have greater risk of superficial SSI or prolonged wound drainage than non-obese patients but are not at increased risk for revision or deep infection in any cohort. Use of a preoperative RST may help to mitigate postoperative complications and readmissions previously associated with morbid and super-obesity. We conclude that THA can be safely performed in super-obese patients and therefore care should not be denied to this population. Summary sentence. Total hip arthroplasty (THA) can be safely performed in morbidly and super-obese patients with the use of a preoperative risk stratification tool (RST) and total joints pathway. For any tables or figures, please contact the authors directly