Internal fixation is currently the standard of care for Garden I and II femoral neck fractures in the elderly. However, there may be a degree of posterior
There is a complex interaction among acetabular component position and the orientation of the femoral component in determining the maximum, impingement-free prosthetic range of motion (ROM) in total hip arthroplasty (THA). Regarding restrictions in ROM, femoral antetorsion is one of the most important parameters. But, ROM is also influenced by parameters like the deviation between the femoral shaft and the mechanical axis in a sagittal projection. This deviation is best described as “Femoral Tilt” (FT). This study analysis the incidence of FT in clinical practice and its consequences on post-operative ROM. Based on these results, the effects of changes in FT on ROM-based cup optimisation are assessed by a using a virtual ROM analysis. For studying the incidence of FT, 40 (16 male, 24 female) postoperative computerised tomography (CT) scans were analysed using a 3D CT planning software. The implant models were superimposed onto the image data to determine their exact position. The anatomical orientations were determined by planning anatomical landmarks and coordinate directions (i.e. mechanical axis, posterior condyle axis). Descriptive statistics were calculated for FT. Effects of changes in FT and CCD on ROM were analysed by calculating zones of compliance. FT was varied between 2.1° and 9.3° for 135°. The overall range of post-operative values for femoral
Displaced distal radial fractures in adults are commonplace. Acknowledging that satisfactory radiographic parameters typically will beget satisfactory functional outcomes, management of these fractures includes a reduction followed by either cast/splint immobilisation or internal fixation. While we can generally rely on internal fixation to maintain the reduction the same is not true of cast immobilisation. There are, however, limited data defining the fate of a fracture reduction in those treated in a cast and up to the time of radial union. Traditional practice is to recommend six weeks of immobilisation. Our goal was to detail the radiographic patterns of change in the radiographic parameters of radial inclination (RI), ulnar variance (UV) and radial
Sagittal pelvic tilt (SPT) can change with spinal pathologies and fusion. Change in the SPT can result in impingement and hip instability. Our aim was to determine the magnitude of the SPT change for hip instability to test the hypothesis that the magnitude of SPT change for hip instability is less than 10° and it is not similar for different hip motions. Hip implant motions were simulated in standing, sitting, sit-to-stand, bending forward, squatting and pivoting in Matlab software. When prosthetic head and liner are parallel, femoral head dome (FHD) faces the center of the liner. FHD moves toward the edge of the liner with hip motions. The maximum distance between the FHD and the center in each motion was calculated and analyzed. To make the results more reliable and to consider the possibility of bony impingement, when the FHD approached 90% of the distance between the liner-center and liner-edge, we considered the hip “in danger for dislocation”. The implant orientations and SPT were modified by 1-degree increments and we used linear regression with receiver operating characteristic (ROC) curve and area under the curve (AUC) to determine the magnitude of SPT change that could cause instability.Introduction
Methods
The aim of this study is to analyse the radiological outcomes and predictors of avascular necrosis following 2-hole DHS in Garden I and II neck of femur fractures in patients more than 60 years with a minimum follow up of one year. We retrospectively reviewed 51 consecutive patients aged more than 60 years who underwent DHS fixation for Garden I and II fractures. Demographics, fracture classification, time to surgery, pre-operative AMTS, preoperative posterior
Abstract. Background. The aim of this study is to analyse the radiological outcomes and predictors of avascular necrosis following 2-hole DHS in Garden I and II neck of femur fractures in patients >60 years with a minimum follow up of one year. Methods. We retrospectively reviewed 51 consecutive patients >60 years who underwent DHS fixation for Garden I and II fractures. Demographics, fracture classification, time to surgery, pre-operative AMTS, preoperative posterior
Thoracic hyperkyphosis (TH – Cobb angle >40°) is correlated with rotator cuff arthropathy and associated with anterior
Scapular notching is a common problem following reverse shoulder arthroplasty (RSA). This is due to impingement between the humeral polyethylene cup and scapular neck in adduction and external rotation. Various glenoid component strategies have been described to combat scapular notching and enhance impingement-free range of motion (ROM). There is limited data available detailing optimal glenosphere position in RSA with an onlay configuration. The purpose of this study was to determine which glenosphere configurations would maximise impingement free ROM using an onlay RSA prosthesis. A three-dimensional (3D) computed tomography (CT) scan of a shoulder with Walch A1, Favard E0 glenoid morphology was segmented using validated software. An onlay RSA prosthesis was implanted and a computer model simulated external rotation and adduction motion of the virtual RSA prosthesis. Four glenosphere parameters were tested; diameter (36mm, 41mm), lateralization (0mm, 3mm, 6mm), inferior
Adverse spinopelvic characteristics (ASC) have been associated with increased dislocation risk following primary total hip arthroplasty (THA). A stiff lumbar spine, a large posterior standing
Tibial plateau fracture reduction involves restoration of alignment and articular congruity. Restorations of sagittal alignment (tibial slope) of medial and lateral condyles of the tibial plateau are independent of each other in the fracture setting. Limited independent assessment of medial and lateral tibial plateau sagittal alignment has been performed to date. Our objective was to characterize medial and lateral tibial slopes using fluoroscopy and to correlate X-ray and CT findings. Phase One: Eight cadaveric knees were mounted in extension. C-arm fluoroscopy was used to acquire an AP image and the C-arm was adjusted in the sagittal plane from 15° of cephalad
Anteroposterior (AP) radiographs remain the standard of care for pre- and post-operative imaging during total hip arthroplasty (THA), despite known limitation of plain films, including the inability to adequately account for distortion caused by variations in pelvic orientation. Of specific interest to THA surgeons are distortions associated with pelvic tilt, as unaccounted for
Distal radius fractures are common in South Africa. Accurate, decisive radiographic parameter interpretation is key in appropriate management. Digital radiographic facilities are rare in the public setting and goniometer usage is known to be low, thus, visual estimates are the primary form of radiographic assessment. Previous research associated orthopaedic experience with accuracy of distal radius fracture parameter estimation but, oftentimes, doctors treating orthopaedic patients are not experienced in orthopaedics. A cross-sectional questionnaire including four distal radius fracture radiographs administered to 149 orthopaedic doctors at three Johannesburg teaching hospitals. Participants grouped into ranks of: consultants (n=36), registrars (n=41), medical officers (n=20) and interns (n=52). Participants visually estimated values of distal radius fracture parameters, stated whether they would accept the position of the fractures and stated their percentage of routine usage of goniometers in real practice. The registrar group was most accurate in visually estimating radial height, whilst the interns were least accurate (p=0.0237). The consultant, registrar and medical officer groups were equally accurate in estimating radial inclination whilst the intern group was the least accurate (p<0.0001). The consultant and registrar group were equally accurate at estimating volar
The Femoral Neck System (FNS) was introduced as an alternative device for the fixation of neck of femur fractures (NOFFs). The purported advantages include superior angular and rotatory stability compared to multiple cancellous screws, via a minimally invasive instrumentation that is simpler than conventional fixed angle devices. There were limited clinical studies regarding the utility of this device. We aimed to study the outcomes of NOFFs fixed with the FNS. This was a single-institution, retrospective review of all undisplaced elderly (≥60 years old) undisplaced young, and displaced young NOFFs fixed with the FNS. Demographics, surgical parameters, radiographic parameters, and clinical outcomes including complications were reviewed. Thirty-six subjects with a median age of 75 [44,89] years old, had NOFF fixation using the FNS. Thirty-one (86.1%) had undisplaced fractures. There were 6 (16.7%), 26 (72.2%), and 4 (11.1%) subjects with Pauwels types 1, 2, and 3 respectively. Thirty-two (88.9%) had posterior
In 2021, Vigdorchik et al. published a large multicentre study validating their simple Hip-Spine Classification for determining patient-specific acetabular component positioning in total hip arthroplasty (THA). The purpose of our study was to apply this Hip-Spine Classification to a sample of Australian patients undergoing THA surgery to determine the local acetabular component positioning requirements. Additionally, we propose a modified algorithm for adjusting cup anteversion requirements. 790 patients who underwent THA surgery between January 2021 and June 2022 were assessed for anterior pelvic plane
Imageless computer navigation systems have the potential to improve acetabular cup position in total hip arthroplasty (THA), thereby reducing the risk of revision surgery. This study aimed to evaluate the accuracy of three alternate registration planes in the supine surgical position generated using imageless navigation for patients undergoing THA via the direct anterior approach (DAA). Fifty-one participants who underwent a primary THA for osteoarthritis were assessed in the supine position using both optical and inertial sensor imageless navigation systems. Three registration planes were recorded: the anterior pelvic plane (APP) method, the anterior superior iliac spines (ASIS) functional method, and the Table
Background. The goal of patellofemoral arthroplasty (PFA) is to replace damaged cartilage, and to correct underlying deformities, to reduce pain and prevent maltracking. We aimed to determine how PFA modifies patellar height,
Distal radius fractures (DRFs) are common injuries that represent 17% of all adult upper extremity fractures. Some fractures deemed appropriate for nonsurgical management following closed reduction and casting exhibit delayed secondary displacement (greater than two weeks from injury) and require late surgical intervention. This can lead to delayed rehabilitation and functional outcomes. This study aimed to determine which demographic and radiographic features can be used to predict delayed fracture displacement. This is a multicentre retrospective case-control study using radiographs extracted from our Analytics Data Integration, Measurement and Reporting (DIMR) database, using diagnostic and therapeutic codes. Skeletally mature patients aged 18 years of age or older with an isolated DRF treated with surgical intervention between two and four weeks from initial injury, with two or more follow-up visits prior to surgical intervention, were included. Exclusion criteria were patients with multiple injuries, surgical treatment with fewer than two clinical assessments prior to surgical treatment, or surgical treatment within two weeks of injury. The proportion of patients with delayed fracture displacement requiring surgical treatment will be reported as a percentage of all identified DRFs within the study period. A multivariable conditional logistic regression analysis was used to assess case-control comparisons, in order to determine the parameters that are mostly likely to predict delayed fracture displacement leading to surgical management. Intra- and inter-rater reliability for each radiographic parameter will also be calculated. A total of 84 age- and sex-matched pairs were identified (n=168) over a 5-year period, with 87% being female and a mean age of 48.9 (SD=14.5) years. Variables assessed in the model included pre-reduction and post-reduction radial height, radial inclination, radial
Analyzing shoulder kinematics is challenging as the shoulder is comprised of a complex group of multiple highly mobile joints. Unlike at the elbow or knee which has a primary flexion/extension axis, both primary shoulder joints (glenohumeral and scapulothoracic) have a large range of motion (ROM) in all three directions. As such, there are six degrees of freedom (DoF) in the shoulder joints (three translations and three rotations), and all these parameters need to be defined to fully describe shoulder motion. Despite the importance of glenohumeral and scapulothoracic coordination, it's the glenohumeral joint that is most studied in the shoulder. Additionally, the limited research on the scapulothoracic primarily focuses on planar motion such as abduction or flexion. However, more complex motions, such as internally rotating to the back, are rarely studied despite the importance for activities of daily living. A technique for analyzing shoulder kinematics which uses 4DCT has been developed and validated and will be used to conduct analysis. The objective of this study is to characterize glenohumeral and scapulothoracic motion during active internal rotation to the back, in a healthy young population, using a novel 4DCT approach. Eight male participants over 18 with a healthy shoulder ROM were recruited. For the dynamic scan, participants performed internal rotation to the back. For this motion, the hand starts on the abdomen and is moved around the torso up the back as far as possible, unconstrained to examine variability in motion pathway. Bone models were made from the dynamic scans and registered to neutral models, from a static scan, to calculate six DoF kinematics. The resultant kinematic pathways measured over the entire motion were used to calculate the ROM for each DoF. Results indicate that anterior
Distal radius fractures are among the most common fractures seen in the emergency department. Closed reduction can provide definitive management when acceptable radiographic parameters are met. Repeated attempts of closed reduction are often performed to improve the alignment and avoid operative management. However, multiple reduction attempts may worsen dorsal comminution and lead to eventual loss of reduction, resulting in no demonstrable benefit. We hypothesize that compared to one closed reduction attempt, repeated closed reduction of extra-articular, dorsally angulated, displaced distal radius fractures has a low success rate in the prevention of operative fixation and improvement of radiographic parameters. Initial and post reduction radiographs for all distal radius fractures managed at Vancouver General Hospital between 2015 and 2018 were reviewed. Inclusion criteria were based on the AO fracture classification and included types 23-A2.1, 23-A2.2 and 23-A3. Exclusion criteria included age less than 18, intra-articular involvement with more than two millimeters of displacement, volar or dorsal Barton fractures, fracture-dislocations, open fractures and volar angulation of the distal segment. Distal radius fractures that met study criteria and underwent two or more attempts of closed reduction were matched by age and gender with fractures that underwent one closed reduction. Radiographic parameters including radial height and inclination, ulnar variance and volar
Distal radius fractures are among the most common fractures seen in the emergency department. Closed reduction can provide definitive management when acceptable radiographic parameters are met. Repeated attempts of closed reduction are often performed to improve the alignment and avoid operative management. However, multiple reduction attempts may worsen dorsal comminution and lead to eventual loss of reduction, resulting in no demonstrable benefit. We hypothesize that compared to one closed reduction attempt, repeated closed reduction of extra-articular, dorsally angulated, displaced distal radius fractures has a low success rate in the prevention of operative fixation and improvement of radiographic parameters. Initial and post reduction radiographs for all distal radius fractures managed at Vancouver General Hospital between 2015 and 2018 were reviewed. Inclusion criteria were based on the AO fracture classification and included types 23-A2.1, 23-A2.2 and 23-A3. Exclusion criteria included age less than 18, intra-articular involvement with more than two millimeters of displacement, volar or dorsal Barton fractures, fracture-dislocations, open fractures and volar angulation of the distal segment. Distal radius fractures that met study criteria and underwent two or more attempts of closed reduction were matched by age and gender with fractures that underwent one closed reduction. Radiographic parameters including radial height and inclination, ulnar variance and volar