Conventional computer navigation systems using bone fixation have been validated in measuring anteroposterior (AP) translation of the tibia. Recent developments in non-invasive skin-mounted systems may allow quantification of AP laxity in the out-patient setting. We tested cadaveric lower limbs (n=12) with a commercial image free navigation system using passive trackers secured by bone screws. We then tested a non-invasive fabric-strap system. The lower limb was secured at 10° intervals from 0° to 60° knee flexion and 100N of force applied perpendicular to the tibial tuberosity using a secured dynamometer. Repeatability coefficient was calculated both to reflect precision within each system, and demonstrate agreement between the two systems at each flexion interval. An acceptable repeatability coefficient of ≤3 mm was set based on diagnostic criteria for ACL insufficiency when using other mechanical devices to measure AP
Objectives. Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results.
The function of the knee joint is to allow for locomotion and is comprised of various bodily structures including the four major ligaments; medial collateral ligament (MCL), lateral collateral ligament (LCL), anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL). The primary function of the ligaments are to provide stability to the joint. The knee is prone to injury as a result of osteoarthritis as well as ligamentous and meniscal lesions. Furthermore, compromised joint integrity due to ligamentous injury may be a result of direct and indirect trauma, illness, occupational hazard as well as lifestyle. A device capable of non-invasively determining the condition of the ligaments in the knee joint would be a useful tool to assist the clinician in making a more informed diagnosis and prognosis of the injury. Furthermore, the device would potentially reduce the probability of a misdiagnosis, timely diagnosis and avoidable surgeries. The existing Laxmeter prototype (UK IPN: GB2520046) is a Stress Radiography Device currently limited to measuring the laxity of the MCL and LCL at multiple fixed degrees of knee flexion. Laxity refers to the measure of a ligament's elasticity and stiffness i.e. the condition of the ligament, by applying a known load (200N) to various aspects of the proximal tibial and thereby inducing
Our objectives were to establish the envelope of passive movement and to demonstrate the kinematic behaviour of the knee during standard clinical tests before and after reconstruction of the anterior cruciate ligament (ACL). An electromagnetic device was used to measure movement of the joint during surgery. Reconstruction of the ACL significantly reduced the overall envelope of tibial rotation (10° to 90° flexion), moved this envelope into external rotation from 0° to 20° flexion, and reduced the anterior position of the tibial plateau (5° to 30° flexion) (p <
0.05 for all). During the pivot-shift test in early flexion there was progressive anterior tibial subluxation with internal rotation. These subluxations reversed suddenly around a mean position of 36 ± 9° of flexion of the knee and consisted of an external tibial rotation of 13 ± 8° combined with a posterior
We have tested the hypothesis that the meniscofemoral ligaments make a significant contribution to resisting anteroposterior and rotatory laxity of the posterior-cruciate-ligament-deficient knee. Eight cadaver human knees were tested for anteroposterior and rotatory laxity in a materials-testing machine. The posterior cruciate ligament (PCL) was then divided, followed by division of the meniscofemoral ligaments (MFLs). Laxity results were obtained for intact, PCL-deficient, and PCL-MFL-deficient knees. Division of the MFLs in the PCL-deficient knee increased posterior laxity between 15° and 90° of flexion. Force-displacement measurements showed that the MFLs contributed 28% to the total force resisting posterior drawer at 90° of flexion in the intact knee, and 70.1% in the PCL-deficient knee. There was no effect on rotatory laxity. This is the first study which shows a function for the MFLs as secondary restraints to posterior
Techniques for the selective cutting of ligaments in cadaver knees defined the static contributions of the posterolateral structures to external rotation, varus rotation and posterior
Summary Statement. ACL reconstruction using a quadriceps tendon autograft was quantitatively evaluated using a robotic testing system. Biomechanical results on joint stability and graft function support its use as an alternative to the hamstrings. Introduction. Recently, a number of surgeons have chosen the quadriceps tendon (QT) autograft as an alternative autograft over the hamstrings tendon for ACL reconstruction because its bone-to-bone healing on one side, large size, and preservation of lateral and rotatory knee function could lead to fewer post-operative complications. However, there have been little or no biomechanical studies that quantitatively evaluate knee function after reconstruction using a QT autograft. Therefore, the objective of this study was to assess the function of a reconstructed knee with a QT autograft and compare the results with a quadrupled semitendinosus and gracilis (QSTG) tendon autograft on the same knee. Methods. Ten human cadaveric knees (57.4 ± 4.2 years of age) were tested using a robotic/UFS testing system in 4 knee states: intact, ACL-deficient, and after ACL reconstruction with both QT and QSTG autografts. Reconstructions were performed in randomised order using posterolateral femoral tunnel placement. The knee kinematics in each state were measured at 5 flexion angles (full extension, 15°, 30°, 60°, and 90°) under 3 externally applied loading conditions: (1) 134 N anterior tibial load (ATL), (2) 134 N ATL with 200 N axial compression, and combined rotatory (CR) load of 10 Nm valgus and 5 Nm internal tibial torque (at 15° and 30°). Based on the established procedure, knee kinematics and in-situ forces were obtained using the principle of superposition. A repeated measures ANOVA was used to compare anterior