Advertisement for orthosearch.org.uk
Results 1 - 20 of 412
Results per page:
Bone & Joint Open
Vol. 4, Issue 9 | Pages 682 - 688
6 Sep 2023
Hampton M Balachandar V Charalambous CP Sutton PM

Aims. Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA. Methods. A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’ knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA. Results. In total, 81 experts (round 1) and 80 experts (round 2 and 3) completed the Delphi Study. Four domains with a total of 24 statements were identified. 100% consensus was reached within the cement preparation, pressurization, and cement curing domains. 90% consensus was reached within the cement application domain. Consensus was not reached with only one statement regarding the handling of cement during initial application to the tibial and/or femoral bone surfaces. Conclusion. The Cementing Techniques In Knee Surgery (CeTIKS) Delphi consensus study presents comprehensive recommendations on the optimal technique for component cementing in TKA. Expert opinion has a place in the hierarchy of evidence and, until better evidence is available these recommendations should be considered when cementing a TKA. Cite this article: Bone Jt Open 2023;4(9):682–688


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 2 - 2
1 Dec 2015
Miller R
Full Access

Introduction. Diabetes is increasing on a global scale. By 2030, 10% of the global population, ½ billon people, are predicted to have diabetes. Potentially there will be a corresponding increase in number of patients referred for surgery. Traditional surgical management of these patients is challenging. Presented is a case series utilizing Minimally Invasive Surgical Techniques of percutaneous metatarsal neck osteotomies, metatarsal head debridement, mid-foot closing-wedge osteotomies and hind-foot arthrodesis, for the surgical management of diabetic foot pathology. The potential socio-economic benefits analysis with regards to reduction in out-patient and theatre time, patient length of stay and time to healing are also postulated. Methods. Minimally Invasive Surgical Techniques of metatarsal neck osteotomy, metatarsal head debridement, closing wedge osteotomy, mid-fusion and hind-foot arthrodesis nailing are described. Procedures are preformed as day cases with fluoroscopic guidance. Low speed, high torque burrs and wedges, create the osteotomies, which can be held with percutaneous fixation. Comparative cost analysis of conservative treatment, including clinic visits, out-patient debridement, dressings, intravenous and oral antibiotics, versus Minimally Invasive Surgical Techniques is presented. Results. Six patients had metatarsal osteotomies for mechanical ulceration. Five reported good outcome. One patient required revision to forefoot arthroplasty due to mal-union. Five patients had debridement of metatarsal heads, which healed on average at six to eight weeks. Eight patients had mid-foot arthrodesis. Two infected cases required removal of metalwork. Three patients had hind-foot arthrodesis for arthritis following ankle fracture with degeneration and deformity. Patients had good short and early medium term outcomes, with no reports of below-knee amputation. This technique is reproducible once the initial learning curve is mastered. Comparative cost analysis, suggests significant financial savings by reducing inpatient admissions, clinic visits and theatre time. Conclusion. Minimally Invasive Surgical Techniques may provide an alternative surgical management for diabetic patient with foot and ankle pathology


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 532 - 540
2 May 2022
Martin H Robinson PG Maempel JF Hamilton D Gaston P Safran MR Murray IR

There has been a marked increase in the number of hip arthroscopies performed over the past 16 years, primarily in the management of femoroacetabular impingement (FAI). Insights into the pathoanatomy of FAI, and high-level evidence supporting the clinical effectiveness of arthroscopy in the management of FAI, have fuelled this trend. Arthroscopic management of labral tears with repair may have superior results compared with debridement, and there is now emerging evidence to support reconstructive options where repair is not possible. In situations where an interportal capsulotomy is performed to facilitate access, data now support closure of the capsule in selective cases where there is an increased risk of postoperative instability. Preoperative planning is an integral component of bony corrective surgery in FAI, and this has evolved to include computer-planned resection. However, the benefit of this remains controversial. Hip instability is now widely accepted, and diagnostic criteria and treatment are becoming increasingly refined. Instability can also be present with FAI or develop as a result of FAI treatment. In this annotation, we outline major current controversies relating to decision-making in hip arthroscopy for FAI.

Cite this article: Bone Joint J 2022;104-B(5):532–540.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 49 - 49
2 Jan 2024
Duquesne K Emmanuel A
Full Access

For many years, marker-based systems have been used for motion analysis. However, the emergence of new technologies, such as 4D scanners provide exciting new opportunities for motion analysis. In 4D scanners, the subjects are measured as a dense mesh, which enables the use of shape analysis techniques. In this talk, we will explore how the combination of the rising new motion analysis methods and shape modelling may change the way we think about movement and its analysis.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 389 - 389
1 Oct 2006
Abu-Rajab R Kelly I Nicol A Stansfield B Nunn T
Full Access

The purpose of this study was to evaluate the effect on movement under load of different techniques of reat-tachment of the humeral tuberosities following 4-part proximal humeral fracture. Biomechanical test sawbones were used. 4-part fracture was simulated and a cemented Neer3 prosthesis inserted. Three different techniques of reattachment of the tuberosities were used – 1)tuberosities attached to the shaft, and to each other through the lateral fins in the prosthesis with one cerclage suture through the anterior hole in the prosthesis, 2)as 1 without cerclage suture, and 3)tuberosities attached to the prosthesis and to the shaft. All methods used a number 5 ethibond suture. Both tuberosities and the shaft had multiple markers attached. Two Digital cameras formed an orthogonal photogrammetric system allowing all segments to be tracked in a 3-D axis system. Humeri were incrementally loaded in abduction using an Instron machine, to a minimum 1200N, and sequential photographs taken. Photographic data was analysed to give 3-D linear and angular motions of all segments with respect to the anatomically relevant humeral axis, allowing intertuberosity and tuberosity-shaft displacement to be measured. Techniques 1 and 2 were the most stable constructs with technique 3 allowing greater separation of fragments and angular movement. True intertuberosity separation at the midpoint of the tuberosities was significantly greater using technique 3 (p< 0.05). The cerclage suture used in technique 2 added no further stability to the fixation. In conclusion, our model suggests that the most effective and simplest technique of reattachment involves suturing the tuberosities to each other as well as to the shaft of the humerus. The cerclage suture appears to add little to the fixation in abduction, although the literature would suggest it may have a role in resisting rotatory movements


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 6 - 6
7 Aug 2023
Hampton M Balachandar V Charalambous C Sutton P
Full Access

Abstract

Introduction

Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA) and this has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA.

Methodology

A UK based, three round, online modified Delphi Expert Consensus Study was completed focussing on cementation technique in TKA. Experts were identified as having a minimum of 5 years Consultant experience in the NHS and fulfilling any one of the following three criteria:

· A ‘high volume’ knee arthroplasty practice (>150 TKA per annum) as identified from the National joint registry (NJR).

· A senior author of at least 5 peer reviewed articles related to TKA in the previous 5 years

· A named trainer for a post CCT fellowship in TKA.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 11 - 11
1 Dec 2022
Bergomi A Adriani M De Filippo F Manni F Motta M Saccomanno M Milano G
Full Access

Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator cuff repair.

The study was designed as a retrospective comparative study on prospectively collected data from a consecutive cohort of patients. All patients who underwent arthroscopic revision rotator cuff repair for symptomatic failure of previous posterosuperior rotator cuff repair were considered eligible for the study. Symptomatic failure had been diagnosed according to clinical examination and confirmed by magnetic resonance imaging (MRI). Structural integrity had been assessed on MRI and classified according to Sugaya classification. Only patients affected by stage IV-V were considered eligible. Tear reparability was confirmed during arthroscopy. Only patients with a minimum 2 years follow-up were included. Patients were divided in two groups. In group 1 (control group) a standard arthroscopic revision and microfractures of the greater tuberosity were performed; in group 2 (experimental group), microfractures of the greater tuberosity and a ECM patch graft were used to enhance tendon repair, followed by postoperative PC injections. Minimum follow-up was 12 months. Primary outcome was the Constant-Murley score (CMS) normalized for age and gender. Subjective outcome was assessed with the Disabilities of the Arm, Shoulder and Hand (DASH) score in its short version (Quick-DASH). Tendon integrity was assessed with MRI at 6 months after surgery. Comparison between groups for all discrete variables at baseline and at follow-up was carried out with the Student's t-test for normally distributed data, otherwise Mann-Whitney U-test was used. Within-group differences (baseline vs follow-up) for discrete variables were analyzed by paired t-test, or by Wilcoxon signed-rank test in case of data with non-normal distribution. Differences for categorical variables were assessed by chi-squared test. Significance was considered for p values < 0.05.

Forty patients were included in the study (20 patients for each group). The mean follow-up was 13 ± 1.6 months. No patients were lost at the follow up. Comparison between groups did not show significant differences for baseline characteristics. At follow-up, mean CMS was 80.7 ± 16.6 points in group 1 and 91.5 ± 11.5 points in group 2 (p= 0.022). Mean DASH score was 28.6 ± 21.6 points in group 1 and 20.1 ± 17.4 points in group 2 (p= 0.178). Post-operative MRI showed 6 healed shoulders in Group 1 and 16 healed shoulders in Group 2 (p<0.004). No postoperative complications were reported in both groups.

The combination of microfractures of the greater tuberosity, ECM patch graft, and subsequent PC subacromial injections is an effective strategy in improving tendon healing rate.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 334 - 334
1 Sep 2005
Abu-Rajab R Kelly I Nicol A Stansfield B
Full Access

Introduction and Aims: The purpose of this study was to evaluate the effect on movement under load of different techniques of reattachment of the humeral tuberosities following four-part proximal humeral fracture. Method: Biomechanical test sawbones were used. Four-part fracture was simulated and a cemented Neer3 prosthesis inserted. Three different techniques of reattachment of the tuberosities were used: 1) tuberosities attached to the shaft, and to each other through the lateral fins in the prosthesis with one cerclage suture through the anterior hole in the prosthesis; 2) as one without cerclage suture; 3) tuberosities attached to the prosthesis and to the shaft. All methods used a number five ethibond suture. Both tuberosities and the shaft had multiple markers attached. Two digital cameras formed an orthogonal photogrammetric system, allowing all segments to be tracked in a 3-D axis system. Humeri were incrementally loaded in abduction using an Instron machine, to a minimum 1200N, and sequential photographs taken. Photographic data was analysed to give 3-D linear and angular motions of all segments with respect to the anatomically relevant humeral axis, allowing intertuberosity and tuberosity-shaft displacement to be measured. Results: Techniques one and two were the most stable constructs with technique three, allowing greater separation of fragments and angular movement. True inter-tuberosity separation at the midpoint of the tuberosities was significantly greater using technique three (p< 0.05). The cerclage suture used in technique two added no further stability to the fixation. Conclusion: Our model suggests that the most effective and simplest technique of reattachment involves suturing the tuberosities to each other, as well as to the shaft of the humerus. The cerclage suture appears to add little to the fixation in abduction, although the literature would suggest it may have a role in resisting rotatory movements


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 159 - 159
1 Apr 2005
Abu-Rajab RB Kelly IG Nicol AC Stansfield B Nunn T
Full Access

The purpose of this study was to evaluate the effect on movement under load of different techniques of reattachment of the humeral tuberosities following 4-part proximal humeral fracture. Biomechanical test sawbones were used. 4-part fracture was simulated and a cemented Neer3 prosthesis inserted. Three different techniques of reattachment of the tuberosities were used – 1)tuberosities attached to the shaft, and to each other through the lateral fins in the prosthesis with one cerclage suture through the anterior hole in the prosthesis, 2)as 1 without cerclage suture, and 3)tuberosities attached to the prosthesis and to the shaft. All methods used a number 5 ethibond suture. Both tuberosities and the shaft had multiple markers attached. Two Digital cameras formed an orthogonal photogrammetric system allowing all segments to be tracked in a 3-D axis system. Humeri were incrementally loaded in abduction using an Instron machine, to a minimum 1200N, and sequential photographs taken. Photographic data was analysed to give 3-D linear and angular motions of all segments with respect to the anatomically relevant humeral axis, allowing intertuberosity and tuberosity-shaft displacement to be measured. Techniques 1 and 2 were the most stable constructs with technique 3 allowing greater separation of fragments and angular movement. True intertuberosity separation at the midpoint of the tuberosities was significantly greater using technique 3 (p< 0.05). The cerclage suture used in technique 2 added no further stability to the fixation. In conclusion, our model suggests that the most effective and simplest technique of reattachment involves suturing the tuberosities to each other as well as to the shaft of the humerus. The cerclage suture appears to add little to the fixation in abduction, although the literature would suggest it may have a role in resisting rotatory movements


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 9 - 9
1 Oct 2022
Rahman T Baxan N Murray R Tavana S Schaer T Smith N Bull J Newell N
Full Access

Introduction

Nucleus replacement surgery has the potential to be an early treatment option for chronic lower back pain. The surgery involves removal (nuclectomy) and replacement of the native degenerated nucleus with a material designed to restore the disc's physiological properties. Multiple techniques have been considered to perform a nuclectomy, however the advantages and disadvantages of each are not well understood. The aim of this study was to quantitatively compare three nuclectomy techniques: automated-shaver, rongeurs, and laser.

Methods and results

Fifteen human vertebra-disc-vertebra lumbar specimens were split into three groups. Before and after nuclectomy axial mechanical tests were performed and T2-weighted 9.4T MRIs were acquired for each specimen. Using the automated-shaver and rongeur similar volumes of disc material were removed (2.51±1.10% and 2.76±1.39% of the total disc volume, respectively), whilst considerably less material was removed when using the laser (0.12±0.07%). Using the automated-shaver and rongeur significantly reduced the toe-region stiffness, while the linear region stiffness was significantly reduced only in the rongeur group. From the MRIs, more homogeneous cavities were seen in the center of the disc when using the automated shaver compared to rongeur, whilst laser ablation resulted in small, localized cavities.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 59 - 59
1 Dec 2022
Hoffer A Peck G Kingwell D McConkey M Leith J Lodhia P
Full Access

To document and assess the available evidence regarding single bundle, hamstrings autograft preparation techniques for Anterior Cruciate Ligament reconstruction (ACLR) and provide graft preparation options for different clinical scenarios.

Three online databases (Embase, PubMed and Ovid [MEDLINE]) were searched from database inception until April 10, 2021. The inclusion criteria were English language studies, human studies, and operative technique studies for single bundle hamstrings autograft preparation for ACLR. Descriptive characteristics, the number of tendons, number of strands, tendon length, graft length and graft diameter were recorded. The methodological quality was assessed using the Methodological Index for Non-Randomized Studies (MINORS) instrument and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system for non-randomized and randomized studies, respectively.

The initial search yielded 5485 studies, 32 met the inclusion criteria. The mean MINORS score across all nonrandomized studies was 8.2 (standard deviation, SD 6.6) indicating an overall low quality of evidence. The mean MINORS score for comparative studies was 17.4 (SD 3.2) indicating a fair quality of evidence. The GRADE assessment for risk of bias in the randomized study included was low.

There were 2138 knees in 1881 participants, including 1296 (78.1%) males and 363 (21.9%) females recorded. The mean age was 30.3 years. The mean follow-up time was 43.9 months when reported (range 16-55 months). Eleven studies utilized the semitendinosus tendon alone, while 21 studies used both semitendinosus and gracilis tendons. There were 82 (3.8%) two-strand grafts, 158 (7.4%) three-strand grafts, 1044 (48.8%) four-strand grafts, 546 (25.5%) five-strand grafts, and 308 (14.4%) six-strand grafts included. Overall, 372 (19.7%) participants had a single-tendon ACLR compared to 1509 (80.2%) participants who had a two-tendon ACLR.

The mean graft diameter was 9.4mm when reported. The minimum semitendinosus and gracilis tendon lengths necessary ranged from 210-280mm and 160-280mm respectively. The minimum graft length necessary ranged from 63-120mm except for an all-epiphyseal graft in the paediatric population that required a minimum length of 50mm. The minimum femoral, tibial, and intra-articular graft length ranged from 15-25mm, 15-35mm and 20-30mm respectively. Thirteen studies detailed intra-operative strategies to increase graft size such as adding an extra strand or altering the tibial and/or femoral fixation strategies to shorten and widen the graft.

Two studies reported ACL reinjury or graft failure rate. One study found no difference in the re-injury rate between four-, five- and six-strand grafts (p = 0.06) and the other found no difference in the failure rate between four- and five- strand grafts (p = 0.55). There was no difference in the post-operative Lysholm score in 3 studies that compared four- and five-strand ACLR. One of the five studies that compared post-operative IKDC scores between graft types found a difference between two- and three- strand grafts, favoring three-strand grafts.

There are many single bundle hamstrings autograft preparation techniques for ACLR that have been used successfully with minimal differences in clinical outcomes. There are different configurations that may be utilized interchangeably depending on the number, size and length of tendons harvested to obtain an adequate graft diameter and successful ACLR.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 75 - 75
22 Nov 2024
Erbeznik A Šturm AC Smrdel KS Triglav T Cvitković-Špik V Kišek TC Kocjancic B Pompe B Dolinar D Mavcic B Mercun A Kolar M Avsec K Papst L Vodicar PM
Full Access

Aim

We prospectively evaluated four different microbiological tools for diagnostics of prosthetic joint infections (PJI), and assessed their impact on the categorization of infection according to EBJIS guidelines. We compared culture, in-house real-time mPCR for S. aureus, S. lugdunensis, S. hominis, S. epidermidis, S. capitis, S. haemolyticus, C. acnes (mPCR), broad-spectrum PCR (Molzym) with 16S rRNA V3-V4 amplicon Sanger sequencing (16S PCR), and 16S rRNA V3-V4 amplicon next-generation sequencing (16S NGS) on MiSeq (Ilumina).

Methods

A total of 341 samples (sonication fluid, tissue biopsy, synovial fluid) were collected from 32 patients with suspected PJI who underwent 56 revision surgeries at the Orthopaedic Centre University Hospital Ljubljana, between 2022 and 2024. Samples were processed using standard protocols for routine culture, followed by DNA isolation using the MagnaPure24 (Roche). All samples were tested with mPCR, and an additional ≥4 samples from each revision (244 in total) were subjected to further metagenomic analysis. Culture results were considered positive if the same microorganism was detected in ≥2 samples, ≥50 CFU/ml were present in the sonication fluid, or ≥1 sample was positive for a more virulent microorganism or if the patient had received antibiotic treatment.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 107 - 107
1 Nov 2021
Salini V
Full Access

Treatment of large bone defects represents a great challenge for orthopedic surgeons. The main causes are congenital abnormalities, traumas, osteomyelitis and bone resection due to cancer. Each surgical method for bone reconstruction leads its own burden of complications. The gold standard is considered the autologous bone graft, either of cancellous or cortical origin, but due to graft resorption and a limitation for large defect, allograft techniques have been identified. In the bone defect, these include the placement of cadaver bone or cement spacer to create the ‘Biological Chamber’ to restore bone regeneration, according to the Masquelet technique.

We report eight patients, with large bone defect (for various etiologies and with an average size defect of 13.3 cm) in the lower and upper limbs, who underwent surgery at our Traumatology Department, between January 2019 and October 2020. Three patients were treated with both cortical and cancellous autologous bone grafts, while five received cortical or cement spacer allografts from donors. They underwent pre and postoperative radiographs and complete osseointegration was observed in all patients already undergoing monthly radiographic checks, with a restoration of length and range of motion.

In our study, both the two stage-Masquelet and the cortical bone graft from a cadaver donor proved to be valid techniques in patients with very extensive defects to reconstruct the defect, restore the length, minimize implant left in situ and achieve complete functional recovery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 5 - 5
1 Jun 2023
Church D Pawson J Hilton C Fletcher J Wood R Brien J Vris A Iliadis A Collins K Lloyd J
Full Access

Introduction

External fixators are common surgical orthopaedic treatments for the management of complex fractures and in particular, the use of circular frame fixation within patients requiring limb reconstruction. It is well known that common complications relating to muscle length and patient function without rehabilitation can occur. Despite this there remains a lack of high-quality clinical trials in this area investigating the role of physiotherapy or rehabilitation in the management of these patients. We aim to complete a systematic review of rehabilitation techniques for patients undergoing external fixator treatment for Limb Reconstruction of the lower limb.

Materials & Methods

A comprehensive search of AMED, CINAHL, MEDLINE and COCHRANE databases was conducted to identify relevant articles for inclusion, using a search strategy developed in collaboration with a research librarian. Inclusion criteria consisted of adults aged 18 years and over who have experienced leg trauma (open fracture, soft tissue damage), elective leg deformity corrective surgery, bone infection or fracture non-union who have been treated with the use of an external fixator for fixation. Specific exclusion criteria were patients below the age of 18 years old, patients with cancer, treatment of the injury with internal nail, patients who underwent amputation, the use of external fixators for soft tissue contracture management, editorials, comment papers, review papers, conference proceedings and non-English papers.

Titles, abstracts, and full texts were screened for suitability by pairs of reviewers according to the inclusion and exclusion criteria using Rayyan QCRI online software. Any conflicts were resolved through discussion with three independent specialist senior reviewers. Following full text screening, references lists of included articles were manually searched to ensure that all relevant studies were identified. Due to lack of evidence, forward searching was also completed for studies included in the review. Data quality was assessed using the mixed methods appraisal tool and the CERT assessment tool was utilised to look at completeness of reporting of exercise interventions.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 3 - 3
23 Feb 2023
Holzer L Finsterwald M Sobhi S Yates P
Full Access

This study aimed to analyze the effect of two different techniques of cement application: cement on bone surface (CoB) versus cement on bone surface and implant surface (CoBaI) on the short-term effect of radiolucent lines (RLL) in primary fully cemented total knee arthroplasties (TKA) with patella resurfacing.

379 fully cemented TKAs (318 patients) were included in this monocentric study. Preoperative and postoperative at week 4 and 12 month after surgery all patients had a clinical and radiological examination and were administered the Oxford Knee Score (OKS). Cement was applied in two different ways among the two study groups: cement on bone surface (CoB group) or cement on bone surface and implant surface (CoBaI group). The evaluation of the presence of RLL or osteolysis was done as previously described using the updated Knee Society Radiographic Evaluation System.

The mean OKS and range of motion improved significantly in both groups at the 4-week and 12-month follow-up, with no significant difference between the groups (CoB vs. CoBaI). RLL were present in 4.7% in the whole study population and were significantly higher in the CoBaI group (10.5%) at the 4-week follow-up. At the 12-month follow-up RLL were seen in 29.8% of the TKAs in the CoBaI group, whereas the incidence was lower in the CoB group (24.0% (n.s.)). There were two revisions in each group. None of these due to aseptic loosening.

Our study indicated that the application of bone cement on bone surface only might be more beneficial than onto the bone surface and onto the implant surface as well in respect to the short-term presence of RLL in fully cemented primary TKA.

The long-term results will be of interest, especially in respect to aseptic loosening and might guide future directions of bone cement applications in TKA.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 39 - 39
23 Feb 2023
Jo O Almond M Rupasinghe H Jo O Ackland D Ernstbrunner L Ek E
Full Access

Neer Type-IIB lateral clavicle fractures are inherently unstable fractures with associated disruption of the coracoclavicular (CC) ligaments. A novel plating technique using a superior lateral locking plate with antero-posterior (AP) locking screws, resulting in orthogonal fixation in the lateral fragment has been designed to enhance stability. The purpose of this study was to biomechanically compare three different clavicle plating constructs.

24 fresh-frozen cadaveric shoulders were randomised into three groups (n=8 specimens). Group 1: lateral locking plate only (Medartis Aptus Superior Lateral Plate); Group 2: lateral locking plate with CC stabilisation (Nr. 2 FiberWire); and Group 3: lateral locking plate with two AP locking screws stabilising the lateral fragment. Data was analysed for gap formation after cyclic loading, construct stiffness and ultimate load to failure, defined by a marked decrease in the load displacement curve.

After 500 cycles, there was no statistically significant difference between the three groups in gap-formation (p = 0.179). Ultimate load to failure was significantly higher in Group 3 compared to Group 1 (286N vs. 167N; p = 0.022), but not to Group 2 (286N vs. 246N; p = 0.604). There were no statistically significant differences in stiffness (Group 1: 504N/mm; Group 2: 564N/mm; Group 3: 512N/mm; p = 0.712). Peri-implant fracture was the primary mode of failure for all three groups, with Group 3 demonstrating the lowest rate of peri-implant fractures (Group 1: 6/8; Group 2: 7/8, Group 3: 4/8; p = 0.243).

The lateral locking plate with orthogonal AP locking screw fixation in the lateral fragment demonstrated the greatest ultimate failure load, followed by the lateral locking plate with CC stabilization. The use of orthogonal screw fixation in the distal fragment may negate against the need for CC stabilization in these types of fractures, thus minimizing surgical dissection around the coracoid and potential complications.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 96 - 96
2 Jan 2024
Bauer C Moser L Otahal A Kern D Dammerer D Zantop T Nehrer S
Full Access

Mincing cartilage with commercially available shavers is increasingly used for treating focal cartilage defects. This study aimed to compare the impact of mincing bovine articular cartilage using different shaver blades on chondrocyte viability.

Bovine articular cartilage was harvested using a scalpel or three different shaver blades (2.5 mm, 3.5 mm, or 4.2 mm) from a commercially available shaver. The cartilage obtained with a scalpel was minced into fragments smaller than 1 mm3. All four conditions were cultivated in a culture medium for seven days. After Day 1 and Day 7, metabolic activity, RNA isolation, and gene expression of anabolic (COL2A1, ACAN) and catabolic genes (MMP1, MMP13), Live/Dead staining and visualization using confocal microscopy, and flow cytometric characterization of minced cartilage chondrocytes were measured.

The study found that mincing cartilage with shavers significantly reduced metabolic activity after one and seven days compared to scalpel mincing (p<0.001). Gene expression of anabolic genes was reduced, while catabolic genes were increased after day 7 in all shaver conditions. The MMP13/COL2A1 ratio was also increased in all shaver conditions. Confocal microscopy revealed a thin line of dead cells at the lesion site with viable cells below for the scalpel mincing and a higher number of dead cells diffusely distributed in the shaver conditions. After seven days, there was a significant decrease in viable cells in the shaver conditions compared to scalpel mincing (p<0.05). Flow cytometric characterization revealed fewer intact cells and proportionally more dead cells in all shaver conditions compared to the scalpel mincing.

Mincing bovine articular cartilage with commercially available shavers reduces the viability of chondrocytes compared to scalpel mincing. This indicates that mincing cartilage with a shaver should be considered a matrix rather than a cell therapy. Further experimental and clinical studies are required to standardize the mincing process with a shaver.

Acknowledgements: This study received unrestricted funding from KARL STORZ SE & Co. KG.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 36 - 36
17 Apr 2023
Davidson D Spratt D Liddle A
Full Access

Prosthetic joint infection (PJI) is an important cause of arthroplasty failure. There is no method to disclose the presence or map the distribution of the in vivo biofilm on infected arthroplasty despite the recognition that such a tool would aid intraoperative decision making and improve novel implant design. The aim of this study was to test the efficacy of four dyes to disclose bacterial biofilm in an in vitro setting.

Four dyes with known affinity to bacterial biofilm were assessed to determine their efficacy to disclose biofilms in an in vitro model of PJI. Three dyes (Methylene Blue, Indocyanine Green and Rose Bengal) have established clinical utility and the other, Thioflavin T, is known to fluoresce in the presence of amyloid a known biofilm constituent. The efficacy of the dyes to discriminate between biofilms of different mass and vitality (high, low or the non-inoculated control) was determined after three minutes exposure of the biofilm to the dyes by calculating the amount of dye bound to the biofilm via sonication and spectrophotometry, quantification of the dye through standardised photographic imaging of the stained biofilm and the calculation of inter-observer agreement. Each experiment was performed in triplicate for each dye and repeated three times.

For each of the disclosure dyes assessed there was significant difference demonstrated between the amount of dye bound to the high and low mass biofilms (p<0.05) as well as in the amount of dye quantified in photographic and fluorescent image assessment between biofilms of differing mass (p<0.01). There was excellent agreement between three observers, for each disclosure dye, in determining the biofilm mass of each stained disc (Kappa>0.91).

This study demonstrates the efficacy of biofilm disclosure dyes in an in vitro PJI model which could one day be used to disclose and map the clinical biofilm in vivo.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 69 - 69
1 Dec 2022
Clarke M Beaudry E Besada N Oguaju B Nathanail S Westover L Sommerfeldt M
Full Access

Meniscal root tears can result from traumatic injury to the knee or gradual degeneration. When the root is injured, the meniscus becomes de-functioned, resulting in abnormal distribution of hoop stresses, extrusion of the meniscus, and altered knee kinematics. If left untreated, this can cause articular cartilage damage and rapid progression of osteoarthritis. Multiple repair strategies have been described; however, no best fixation practice has been established. To our knowledge, no study has compared suture button, interference screw, and HEALICOIL KNOTLESS fixation techniques for meniscal root repairs. The goal of this study is to understand the biomechanical properties of these fixation techniques and distinguish any advantages of certain techniques over others. Knowledge of fixation robustness will aid in surgical decision making, potentially reducing failure rates, and improving clinical outcomes.

19 fresh porcine tibias with intact medial menisci were randomly assigned to four groups: 1) native posterior medial meniscus root (PMMR) (n = 7), 2) suture button (n = 4), 3) interference screw (n = 4), or 4) HEALICOIL KNOTLESS (n = 4). In 12 specimens, the PMMR was severed and then refixed by the specified group technique. The remaining seven specimens were left intact. All specimens underwent cyclic loading followed by load-to-failure testing. Elongation rate; displacement after 100, 500, and 1000 cycles; stiffness; and maximum load were recorded.

Repaired specimens had greater elongation rates and displacements after 100, 500, and 1000 cycles than native PMMR specimens (p 0.05). The native PMMR showed greater maximum load than all repair techniques (p 0.05). In interference screw and HEALICOIL KNOTLESS specimens, failure occurred as the suture was displaced from the fixation and tension was gradually lost. In suture button specimens, the suture was either displaced or completely separated from the button. In some cases, tear formation and partial failure also occurred at the meniscus luggage tag knot. Native PMMR specimens failed through meniscus or meniscus root tearing.

All fixation techniques showed similar biomechanical properties and performed inferiorly to the native PMMR. Evidence against significant differences between fixation techniques suggests that the HEALICOIL KNOTLESS technique may present an additional option for fixation in meniscal root repairs. While preliminary in vitro evidence suggests similarities between fixation techniques, further research is required to determine if clinical outcomes differ.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 70 - 70
1 Nov 2021
Yener C Aljasim O Demirkoparan M Bilge O Binboğa E Argın M Küçük L Özkayın N
Full Access

Introduction and Objective

Scapholunate instability is the most common cause of carpal instability. When this instability is left untreated, the mechanical relationship between the carpal bones is permanently disrupted, resulting in progressive degenerative changes in the radiocarpal and midcarpal joints. Different tenodesis methods are used in the treatment of acute or early chronic reducible scapholunate instability, where arthritis has not developed yet and the scapholunate ligament cannot be repaired. Although it has been reported that pain is reduced in the early follow up in clinical studies with these methods, radiological results differ between studies. The deterioration of these radiological parameters is associated with wrist osteoarthritis as previously stated. Therefore, more studies are needed to determine the tenodesis method that will improve the wrist biomechanics better and will last longer. In our study, two new tenodesis methods, spiral antipronation tenodesis, and anatomic front and back reconstruction (ANAFAB) were radiologically compared with triple ligament tenodesis (TLT), in the cadaver wrists.

Materials and Methods

The study was carried out on a total of 16 fresh frozen cadaver wrists. Samples were randomly allocated to the groups treated with 3 different scapholunate instability treatment methods. These are TLT (n: 6), spiral antipronation tenodesis (n: 5) and ANAFAB tenodesis (n: 5) groups. In all samples SLIL, DCSS, STT, DIC, RSC and LRL ligaments were cut in the same way to create scapholunate instability. Wrist CT scans were taken on the samples in 4 different states, in intact, after the ligaments were cut, after the reconstruction and after the movement cycle. In all of these 4 states, wrist CTs were taken in 6 different wrist positions. For every state and every position through tomography images; Scapholunate (SL) distance, Scapholunate (SL) angle, Radioscaphoid (RS) angle, Radiolunate (RL) angle, Capitolunate (CL) angle, Dorsal scaphoid translation (Dt) measurements were made.