Abstract. Introduction. Mid-flexion instability may cause poor outcomes following TKA. Surgical
Abstract. Introduction. Derby
Aims. Ideal component sizing may be difficult to achieve in unicompartmental knee arthroplasty (UKA). Anatomical variants, incremental implant size, and a reduced surgical exposure may lead to over- or under-sizing of the components. The purpose of this study was to compare the accuracy of UKA sizing with robotic-assisted
Aims. In-hospital length of stay (LOS) and discharge dispositions following arthroplasty could act as surrogate measures for improvement in patient pathways, and have major cost saving implications for healthcare providers. With the ever-growing adoption of robotic technology in arthroplasty, it is imperative to evaluate its impact on LOS. The objectives of this study were to compare LOS and discharge dispositions following robotic arm-assisted total knee arthroplasty (RO TKA) and unicompartmental arthroplasty (RO UKA) versus conventional
Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this
Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed.Aims
Methods
Introduction. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasties (TKAs). However, if the diaphysis has been previously violated (as in revision of a failed stemmed implant), the resultant sclerotic canal can impair cemented stem fixation, which is vital for cone ingrowth and long-term fixation. We report the outcomes of our novel solution to this problem, in which impaction grafting and a cemented stem in the diaphysis was combined with an uncemented metaphyseal cone for revision TKAs with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems in a novel fashion for 35 revision TKAs. Mean age at revision TKA was 70 years, with 63% being male. Patients had a mean of 4 prior knee arthroplasty procedures. Indications for the revision with this construct were aseptic loosening (80%) and two-stage re-implantation for periprosthetic infection (PJI; 20%). Mean follow-up was 3 years. Results. Survivorship free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at 5 years. Survivorships free from any revision of the cone/impaction grafting construct and free from any reoperation were 92% and 73% at 5 years, respectively. Six knees (17%) required a reoperation (4 for infection/wound issues and 2 for periprosthetic fractures). Radiographically, 97% of cones were ingrown (1 loose cone in setting of PJI). In all but one case, impacted diaphyseal bone graft appeared to have incorporated radiographically. Conclusions. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this innovative
Objectives. The lack of effective treatment for cartilage defects has prompted investigations using tissue engineering
Intro/Purpose. Lateral partial knee replacement is indicated as an alternative to total knee replacement for isolated end stage lateral compartment degenerative joint disease. The purpose of this study is to report the surgical
Introduction. There are numerous surgical
Purpose of Study. 1- To introduce a new graft
Aims. This non-blinded randomised controlled trial compared the effect
of patient-controlled epidural analgesia (PCEA) versus local
infiltration analgesia (LIA) within an established enhanced recovery
programme on the attainment of discharge criteria and recovery one
year after total knee arthroplasty (TKA). The hypothesis was that
LIA would increase the proportion of patients discharged from rehabilitation
by the fourth post-operative day but would not affect outcomes at
one year. Patients and Methods. A total of 242 patients were randomised; 20 were excluded due
to failure of spinal anaesthesia leaving 109 patients in the PCEA
group and 113 in the LIA group. Patients were reviewed at six weeks
and one year post-operatively. Results. There was no difference in the proportion of patients discharged
from rehabilitation by the fourth post-operative day, (77% in the
PCEA group, 82% in the LIA group, p = 0.33), mean length of stay
(four days in each group, p = 0.540), day of first mobilisation
(p = 0.013) or pain (p = 0.278). There was no difference in mean
Oxford Knee Scores (41 points in each group, p = 0.915) or the rate
of complications in the two groups. Conclusion. Both
We have compared a new
The aim of this study was to analyse the gait
pattern, muscle force and functional outcome of patients who had undergone
replacement of the proximal tibia for tumour and alloplastic reconstruction
of the extensor mechanism using the patellar-loop
We assessed the reliability, accuracy and variability of closed-wedge high tibial osteotomy (HTO) using computer-assisted surgery compared to the conventional
Infection following TKA can be a catastrophic complication that can cause significant pain, morbidity and jeopardize limb viability. The integrity of the soft tissue envelope is critical to successful treatment and infection control. While local tissue flaps can provide adequate coverage for most soft tissue defects around the knee, there are cases that require salvage using microvascular free tissue transfers. The purpose of this study is to evaluate the 1) rate of limb salvage; 2) infection control; and 3) clinical function following free flap coverage for salvage of the infected TKA. We retrospectively reviewed 23 microvascular free tissue transfers for management of soft tissue defects in infected TKA. There were 16 men and 7 women with a mean age of 61.2 years (range 39–81). The median number of procedures performed prior to soft tissue coverage was 5 (range 2–9) and all patients had failed at least one 2 stage reimplantation procedure. Clinical outcomes were measured using the Knee Society Scoring system for pain and function. The rate of limb salvage and infection control were recorded.Introduction
Materials and Methods
The dysplastic Trochlear is a developmental condition characterised by an abnormally flat or dome-shaped trochlea and it is recognised as a significant cause of patella instability, with the increased sulcus angle being is the most common finding. Surgical correction of the shape of the Trochlear Groove is frequently performed. The described methods in the literature involve open arthrotomy to normalise and maintain the trochlear morphology achieving normal alignment and tracking of the patella. Open procedures carries a significant risk of arthrofibrosis. The
A prospective study of 276 TKA's performed in patients with valgus knee deformity ≥ 10° using a Modified Surgical
We describe the results of 50 operations carried out on 46 patients with medial osteoarthritis of the knee of Ahlbäck grade 1 to 3. Patients were randomised either to a closed-wedge high tibial osteotomy (HTO) or an open-wedge procedure based on the hemicallotasis
Anterior cruciate ligament (ACL) reconstruction
is commonly performed and has been for many years. Despite this, the
technical details related to ACL anatomy, such as tunnel placement,
are still a topic for debate. In this paper, we introduce the flat
ribbon concept of the anatomy of the ACL, and its relevance to clinical
practice. Cite this article: