Modular tapered stems have become increasingly popular in femoral revisions and stem subsidence remains a reported clinical problem. Computer modeling and biomechanical testing demonstrated a minimum initial line-to-line fit of 25 mm was required to reduce the risk of subsidence. We examined XR imaging of 110 consecutive femoral revisions by a single surgeon using two different modular tapered stems to determine if this biomechanical threshold was of clinical relevance. 72% of the revisions were done for aseptic loosening and 28% for periprosthetic fracture or infection. Stem subsidence of any degree was observed in 24 (21.8%), while 12 (10.9%) demonstrated substantial subsidence of > 10 mm. We matched this cohort to 12 patients who had no stem subsidence. The average age of patients with subsidence was 59 years (43 to 79 years). The average of patients without subsidence was 66 years (41 to 77 years). Each group had 7 men and 5 women. Stem subsidence was observed in the first 3 months post-surgery. The demographics, bone deficiency, stem design, and stem diameter were similar between groups. 83% of patients with substantial stem subsidence had less than 25 mm of line-to-line fit compared to 17% of patients without subsidence. The 12 cases of no stem subsidence had a mean line-to-line fit of 48 mm (25 to 55 mm). 75% of patients with substantial stem subsidence had also undergone an extended trochanteric osteotomy (ETO) compared to 33% of patients without subsidence. We conclude that there is a positive correlation with the biomechanical testing parameters and substantial stem subsidence. ETO was found to be associated with higher stem subsidence.
The aim of this study is to determine whether fixation, as opposed to revision arthroplasty, can be safely used to treat reducible Vancouver B type fractures in association with a cemented collarless polished tapered femoral stem (the Exeter). This is a retrospective cohort study of 152 operatively managed consecutive unilateral Vancouver B fractures involving Exeter stems. 130 were managed with open reduction and internal fixation (ORIF) and 22 with revision arthroplasty. Radiographs were assessed and classified by 3 observers. The primary outcome measure was revision of ≥1 component. Kaplan Meier survival analysis was performed. Logistic regression was used to identify risk factors for revision following ORIF. Secondary outcomes included any reoperation, complications, blood transfusion, length of hospital stay and mortality. Fractures (B1 n=74 (49%); B2 n=50 (33%); and B3 n=28 (18%)) occurred at mean 6.7±10.4 years after primary THA (n=143) or hemiarthroplasty (n=15). Mean follow up was 6.5 ±2.6 years (3.2 to 12.1). Rates of revision and reoperation were significantly higher following revision arthroplasty compared to ORIF for B2 (p=0.001) fractures and B3 fractures (p=0.05). Five-year survival was significantly better following ORIF: 92% (86.4 to 97.4 95%CI) Vs 63% (41.7 to 83.3), p<0.001. No independent predictors of revision following ORIF were identified: fixation of B2 or B3 fractures was not associated with an increased risk of revision. Dislocation was the commonest mode of failure after revision arthroplasty. ORIF was associated with reduced blood transfusion requirement and reoperations, but there were no differences in medical complications, hospital stay or mortality between surgical groups. When the bone-cement interface was intact and the fracture was anatomically reducible, Vancouver B2 fractures around Exeter stems can be treated with fixation as opposed to revision arthroplasty. Fixation of Vancouver B3 fractures can be performed in frail elderly patients without increasing revision risk.
For over a decade, modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. The aim of this study was to report the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years follow-up. We identified 126 patients who received a single monoblock TFT stem - 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous prosthetic joint infection (PJI), 42 for aseptic loosening, 9 for trunnionosis, 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3 months follow-up were determined. We evaluated the number and indications for re-operations. The mean time from surgery was 3.9 years (range 2.0 to 6.9 years). A paired t-test analysis showed significant improvement from pre-operative versus post-operative clinical outcome scores (p<0.001) for HHS (38.76 +/- 15.24vs. 83.42 +/- 15.38), WOMAC (45.6 ± 19.0 vs. 69.9 ± 21.3) and SF-12 Physical component (31.7 ± 8.1 vs. 37.8 ± 11.3) and SF-12 Mental component (48.2 ± 12.2 vs. 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%) and Grade 4 (1.6%) cases. There were 18 re-operations (14.7%) with 13 for PJI (7 treated with implant retention, 6 treated with a two-staged revision), 4 for instability and one for acetabular aseptic loosening. There were no aseptic failures of the stem. This novel modern monoblock TFT stem provided reliable femoral fixation and has increasingly supplanted the use of modular TFT stems for complex primary and revision surgery in our institution.
Tapered, fluted, modular, titanium stems are
increasingly popular in the operative management of Vancouver B2 and
selected B3 peri-prosthetic femoral fractures. We have reviewed
the results at our institution looking at stem survival and clinical
outcomes and compared this with reported outcomes in the literature.
Stem survival at a mean of 54 months was 96% in our series and 97%
for combined published cases. Review of radiology showed maintenance
or improvement of bone stock in 89% of cases with high rates of
femoral union. Favourable clinical outcome scores have reported
by several authors. No difference in survival or clinical scores
was observed between B2 and B3 fractures.
Tapered, fluted, modular, titanium stems have
a long history in Europe and are increasing in popularity in North America.
We have reviewed the results at our institution looking at stem
survival and clinical outcomes. Radiological outcomes and quality
of life assessments have been performed and compared to cylindrical
non-modular cobalt chromium stems. Survival at five years was 94%.
This fell to 85% at ten years due to stem breakage with older designs.
Review of radiology showed maintenance or improvement of bone stock
in 87% of cases. Outcome scores were superior in tapered stems despite
worse pre-operative femoral deficiency.
The aim of this study was to evaluate the suitability of the tapered cone stem in total hip arthroplasty (THA) in patients with excessive femoral anteversion and after femoral osteotomy. We included patients who underwent THA using Wagner Cone due to proximal femur anatomical abnormalities between August 2014 and January 2019 at a single institution. We investigated implant survival time using the endpoint of dislocation and revision, and compared the prevalence of prosthetic impingements between the Wagner Cone, a tapered cone stem, and the Taperloc, a tapered wedge stem, through simulation. We also collected Oxford Hip Score (OHS), visual analogue scale (VAS) satisfaction, and VAS pain by postal survey in August 2023 and explored variables associated with those scores.Aims
Methods
We describe our technique and rationale using
hybrid fixation for primary total hip arthroplasty (THA) at the Hospital
for Special Surgery. Modern uncemented acetabular components have
few screw holes, or no holes, polished inner surfaces, improved
locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented
sockets can be combined with highly cross-linked polyethylene liners,
which have demonstrated very low wear and osteolysis rates after
ten to 15 years of implantation. The results of cement fixation
with a smooth or polished surface finished stem have been excellent,
virtually eliminating complications seen with cementless fixation
like peri-operative femoral fractures and thigh pain. Although mid-term
results of modern cementless stems are encouraging, the long-term
data do not show reduced revision rates for cementless stems compared
with cemented smooth stems. In this paper we review the conduct
of a hybrid THA, with emphasis on pre-operative planning, surgical
technique, hypotensive epidural anaesthesia, and intra-operative
physiology. Cite this article:
In 2012 we reviewed a consecutive series of 92
uncemented THRs performed between 1986 and 1991 at our institution
using the CLS Spotorno stem, in order to assess clinical outcome
and radiographic data at a minimum of 21 years. The series comprised
92 patients with a mean age at surgery of 59.6 years (39 to 77)
(M:F 43;49). At the time of this review, seven (7.6%) patients had died and
two (2.2%) were lost to follow-up. The 23-year Kaplan–Meier survival
rates were 91.5% (95% confidence intervals (CI) 85.4% to 97.6%;
55 hips at risk) and 80.3% (95% CI, 71.8% to 88.7%; 48 hips at risk)
respectively, with revision of the femoral stem or of any component
as endpoints. At the time of this review, 76 patients without stem
revision were assessed clinically and radiologically (mean follow-up
24.0 years (21.5 to 26.5)). For the 76 unrevised hips the mean Harris
hip score was 87.1 (65 to 97). Femoral osteolysis was detected in
five hips (6.6%) only in Gruen zone 7. Undersized stems were at
higher risk of revision owing to aseptic loosening (p = 0.0003).
Patients implanted with the stem in a varus position were at higher risk
of femoral cortical hypertrophy and thigh pain (p = 0.0006 and p
= 0.0007, respectively). In our study, survival, clinical outcome and radiographic data
remained excellent in the third decade after implantation. Nonetheless,
undersized stems were at higher risk of revision owing to aseptic
loosening. Cite this article: