Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of intertrochanteric femoral fractures. There is a known statistical relationship between a tip-apex distance (TAD) >25mm and higher rate of implant failure. Our aim was to analyse all DHS procedures performed in our trust from seventeen months and compare their
Awareness that minimising tip apex distance (TAD) when inserting a sliding hip screw reduces the risk of screw cut out is important for orthopaedic trainees. The advent of the Picture Archive and Communication System (PACS) has made the accurate measurement of
Intra-operative Tip-Apex Distance (TAD) estimation optimises dynamic hip screw (DHS) placement during hip fracture fixation, reducing risk of cut-out. Thread-width of a standard DHS screw measures approximately 12.5 millimetres. We assessed the effect of introducing screw thread-width as an intra-operative distance reference to surgeons. The null hypothesis was that there were no differences between hip fracture fixation before and after this intervention. Primary outcome measure was
Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and national joint registry data were reviewed for follow up. No significant difference was found in overall failure rate of PFNA vs InterTan (4.84% vs 3.23%; p = 0.748). Overall, short nails were more likely to fail by cut-out than long nails (7.5% vs 1.2%; p = 0.015). Nails which failed by varus cut-out had a higher tip/apex distance (TAD) (26.2mm vs 17.0mm; p < 0.001). Of concern, varus cut-out occurred in two InterTan nails with
The PFNA is used routinely at the RUH for unstable peri-trochanteric and femoral fractures. Failure of operative treatment is associated with increased morbidity and financial burden. We analysed surgical and fracture factors, aiming to identify those associated with fixation failure. Retrospective analysis of 76 consecutive patients treated with a PFNA between 2009–2012 was performed. Patient demographics were assessed, along with fracture classification, adequacy of reduction, tip apex distance (TAD) and grade of surgeon. Failure was defined as metal work failure, non-union or need for repeat procedure. The mean age was 78.9 years (25.9–97.4). 21 were male and 49 female. There were 17 failures (24.3%) (7 required further surgery). 10 failures were per-trochanteric, 2 sub-trochanteric and 5 mid-shaft fractures. Complications included 4 broken and 6 backed-out distal locking screws, 2 blade cut-outs, 1 nail fracture and 4 non-unions. All per-trochanteric were adequately reduced with a
The aim of this study was to establish any association between implant cut-out and a Tip Apex Distance (TAD), ≥25mm, in proximal femoral fractures, following closed reduction and stabilisation, with either a Dynamic Hip Screw (DHS) or Intramedullary Hip Screw (IMHS) device. Furthermore, we investigated whether any difference in cut-out rate was related to fracture configuration or implant type. WE conducted a retrospective review of the full clinical records and radiographs of 65 consecutive patients, who underwent either DHS or IMHS fixation of proximal femoral fractures. The
Introduction. The reverse obliquity fractures of the proximal femur are anatomically and mechanically different from most intertrochanteric fractures. These fractures are complex and very difficult to treat. To evaluate the results of the treatment of reverse obliquity intertrochanteric fractures with cephalomedullary nails. Materials and Methods. Between 2005 and 2009, 1179 extracapsular fractures of the proximal femur were treated at our institution. Retrospective review of these x-rays identified 59 patients with reverse obliquity fracture pattern. We analysed our results of cephalomedullary nailing of these complex fractures and evaluated factors responsible for failure of fixation. Results. Of the 59 patients with reverse oblique fracture pattern, one patient was treated with DHS, and two other patients didn't have post-operative x-rays and therefore were excluded from the study. Of the remaining 56 patients treated with cephalomedullary nails, forty eight were treated with gamma nails, five with PFNA and three with ATN. There were 40 females and 16 males with median age of 81.3 years (17–103 years). Six of the fifty six (10.7%) failed to heal or had failure of fixation. The failure rate was four of forty eight for the gamma nails, one of five of the PFNA and one of three of ATN. One of thirty seven (2.7%) of anatomically reduced fractures and five of nineteen (26.3%) of non-anatomically reduced fractures had failure of treatment (p = 0.01). Three of thirteen (23.1%) with femoral medialisation and three of forty three (6.9%) without femoral medialisation had failure of treatment (p = 0.13). Four of forty four (9.1%) with avulsed lesser trochanter and two of twelve (16.6%) without avulsion had failure of treatment (p = 0.59). Three of thirty seven (8.1%) with tip apex distance (TAD) of less than twenty and three of nineteen (15.7%) with