Advertisement for orthosearch.org.uk
Results 1 - 20 of 36
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 36 - 36
7 Aug 2023
Matthews S Acton D Tucker A Graham J
Full Access

Abstract. Introduction. The Syn-VAR RCT is the first of its kind comparing hamstrings autograft v synthetic neoligament for MPFL reconstruction. Our aim is to evaluate short and long term patient related outcomes measures (PROMs) following synthetic / autologous MPFL reconstruction in a heterogenous cohort of patients with recurrent patellar instability. Method. 20 patients meeting inclusion criteria were recruited and randomised. Standardised surgery was performed by a single surgeon in Altnagelvin Hospital with data collected over 3 years from 2016. Kujala score was the primary outcome measure with data captured preoperatively and 12 weeks/2 years postoperatively. Secondary outcomes included four other validated scores and complications including Norwich Patellar Instability, Lysholm, IKDC and Banff. Results. 20 patients with an average age of 19 included 9 females and 11 males. At 12 weeks and 2 years Kujala improvement in the hamstring group was 18 and 32 (both p<0.05) compared to the synthetic group where the increase was 2 and 20 (p<0.05). All secondary score improvements at 2 years were significant (p<0.05) with no difference in any score at all time intervals when comparing both groups (p<0.05). Discussion. Our RCT validates the non-inferiority of synthetic MPFL reconstruction as a treatment for restoring patellar stability in a small heterogenous group with positive long term data and minimal morbidity. With no hamstring harvesting offering a reduction in theatre time with this offers a safe, efficient and viable alternative with reduced morbidity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 68 - 68
7 Aug 2023
Ball S Jones M Pinheiro VH Church S Williams A
Full Access

Abstract. Introduction. The aim of this study was to determine if elite athletes could return to professional sport after MCL or PLC reconstruction using LARS ligaments and to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries and complications. Methods. A retrospective review of all extra-articular knee ligament reconstructions in elite athletes utilising LARS ligaments by 3 knee surgeons between January 2013 and October 2020 was undertaken. Return to play (RTP) was defined as competing at professional level or national/ international level in amateur sport. Results. Sixty-four (84.2%) MCL and 12 (15.8%) PLC reconstructions utilising LARS in elite athletes were included. 52 (68.4%) underwent concomitant cruciate(s) reconstruction. The mean age was 25.1 years (SD +/− 4.50. Most were football (35, 46.1%) or rugby players (35, 46.1%). Sixty-seven athletes (88.2%) RTP with 65 (97.0%) of these playing at the same or higher Tegner level. 56 (83.6%) and 20 (57.1%) were still playing at 2 and 5 years post-surgery. Six (7.9%) players (5 of whom RTP) required further surgery relating to the LARS / metalwork and there was one case of adverse local inflammatory reaction to the synthetic material. There was one MCL re-rupture, sustained 4 years after RTP. Conclusion. Utilising LARS in extra-articular knee ligament reconstructions allows 88.2% of athletes, with a variety of knee ligament injuries, to return to elite sport. The low morbidity rates coupled with 57% of athletes still playing 5 years post-surgery suggests the LARS is safe and effective in these cases


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 17 - 17
1 Mar 2012
Verdonk P Huysse W Verdonk R
Full Access

Purposes of the study. To assess the performance of an acellular synthetic scaffold in the treatment of painful partial meniscal tissue loss. Methods. Subjects recruited (n=52) had irreparable medial or lateral meniscus partial meniscus loss, intact rim, presence of both horns and a stable well aligned knee. Diagnostic imaging was used to assess tissue ingrowth at 3 months post-implantation by evidence of vascularisation in the scaffold using DCE-MRI with intravenous gadolinium contrast material (n=42). All DCE-MRI scans were assessed centrally for neovascularisation in the peripheral half of the scaffold meniscus and integration of the implanted device. Stability of tissue ingrowth and cartilage scores in the index compartment were assessed at 12 and 24 months post-implantation using anatomic MRI scans. Results. The 52 patients recruited (75% males) had a mean age of 30.8 ± 9.4 years and mean longitudinally measured lesions of 47.1 ± 10.0 mm, involving 34 medial and 18 lateral indications. At 3 months post-implantation tissue ingrowth was demonstrated in the peripheral half of the scaffold, in 36/42 (85.7%) subjects. To date stable or improved cartilage scores were seen in the index compartment at 12 months (n= 47) and 24 months (n=9). No signs of an inflammatory reaction to the scaffold or its degradation products were observed. The tissue observed on MRI at 12 months (n=47) remained stable at 24 months (n=9). No safety issues related to the scaffold were reported. Conclusions. These preliminary results indicate that this novel scaffold induces ingrowth of stable tissue


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 88 - 88
1 Jul 2022
Rajput V Reddy G Singh S Iqbal S Salim M Anand S
Full Access

Abstract. Introduction. Traumatic knee dislocations are devastating injuries and there is no single best accepted treatment. This study looked at functional outcome of a single surgeon case series of patients who underwent surgical management of their knee dislocation. Methods. Eighty-seven patients with knee dislocation were treated at a major trauma centre. Acute surgical repair and reconstruction with fracture fixation within 4 weeks was preferred unless the patient was too unstable (Injury severity score>16). The collaterals were repaired and augmented using a variety of autografts, allografts or synthetic grafts. PCL was primarily braced and reconstructed subsequently, if required. Outcome was collected prospectively using IKDC score, KOOS and Tegner score. Results. The mean age of the patients was 33.6yrs (SD 11.9), 66 males and 21 females. According to Schenck classification, 26 were KD-I (30%), 6 KD-II (7%), 13 were KD-III (15%), 7 were KD-IV (8%) and 35 were KD-V (40%). 7 patients had CPN injury (8%), 3 had vascular injury (3.4%), 2 had combined CPN and vascular injury (2.3%). Acute surgical treatment was done in 62 patients while 10 had staged reconstruction. 22 patients had delayed reconstruction. The mean follow-up period was 5.8 years (1- 12 yrs), mean IKDC score was 57.6 (SD 23.6). The mean Tegner activity scale postoperatively was 4.5(SD 2) and the mean KOOS score was 74.9 (SD 19.6). Conclusion. A large proportion of cases were KD-V but still had a good outcome with surgical management. Current classification systems do not cover all dislocation patterns and a modification is proposed


Bone & Joint Open
Vol. 5, Issue 9 | Pages 758 - 765
12 Sep 2024
Gardner J Roman ER Bhimani R Mashni SJ Whitaker JE Smith LS Swiergosz A Malkani AL

Aims

Patient dissatisfaction following primary total knee arthroplasty (TKA) with manual jig-based instruments has been reported to be as high as 30%. Robotic-assisted total knee arthroplasty (RA-TKA) has been increasingly used in an effort to improve patient outcomes, however there is a paucity of literature examining patient satisfaction after RA-TKA. This study aims to identify the incidence of patients who were not satisfied following RA-TKA and to determine factors associated with higher levels of dissatisfaction.

Methods

This was a retrospective review of 674 patients who underwent primary TKA between October 2016 and September 2020 with a minimum two-year follow-up. A five-point Likert satisfaction score was used to place patients into two groups: Group A were those who were very dissatisfied, dissatisfied, or neutral (Likert score 1 to 3) and Group B were those who were satisfied or very satisfied (Likert score 4 to 5). Patient demographic data, as well as preoperative and postoperative patient-reported outcome measures, were compared between groups.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1339 - 1347
1 Oct 2013
Scott CEH Eaton MJ Nutton RW Wade FA Pankaj P Evans SL

As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves (‘hits’) produced when damage occurs in material. Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint. . Cite this article: Bone Joint J 2013;95-B:1339–47


Bone & Joint Open
Vol. 5, Issue 11 | Pages 1003 - 1012
8 Nov 2024
Gabr A Fontalis A Robinson J Hage W O'Leary S Spalding T Haddad FS

Aims

The aim of this study was to compare patient-reported outcomes (PROMs) following isolated anterior cruciate ligament reconstruction (ACLR), with those following ACLR and concomitant meniscal resection or repair.

Methods

We reviewed prospectively collected data from the UK National Ligament Registry for patients who underwent primary ACLR between January 2013 and December 2022. Patients were categorized into five groups: isolated ACLR, ACLR with medial meniscus (MM) repair, ACLR with MM resection, ACLR with lateral meniscus (LM) repair, and ACLR with LM resection. Linear regression analysis, with isolated ACLR as the reference, was performed after adjusting for confounders.


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims

The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA).

Methods

Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95th percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone.


Bone & Joint Research
Vol. 11, Issue 4 | Pages 229 - 238
11 Apr 2022
Jaeger S Eissler M Schwarze M Schonhoff M Kretzer JP Bitsch RG

Aims

One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined.

Methods

A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD).


Bone & Joint Research
Vol. 10, Issue 4 | Pages 269 - 276
1 Apr 2021
Matsubara N Nakasa T Ishikawa M Tamura T Adachi N

Aims

Meniscal injuries are common and often induce knee pain requiring surgical intervention. To develop effective strategies for meniscus regeneration, we hypothesized that a minced meniscus embedded in an atelocollagen gel, a firm gel-like material, may enhance meniscus regeneration through cell migration and proliferation in the gel. Hence, the objective of this study was to investigate cell migration and proliferation in atelocollagen gels seeded with autologous meniscus fragments in vitro and examine the therapeutic potential of this combination in an in vivo rabbit model of massive meniscus defect.

Methods

A total of 34 Japanese white rabbits (divided into defect and atelocollagen groups) were used to produce the massive meniscus defect model through a medial patellar approach. Cell migration and proliferation were evaluated using immunohistochemistry. Furthermore, histological evaluation of the sections was performed, and a modified Pauli’s scoring system was used for the quantitative evaluation of the regenerated meniscus.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 43 - 48
1 Jun 2020
D’Lima DP Huang P Suryanarayan P Rosen A D’Lima DD

Aims

The extensive variation in axial rotation of tibial components can lead to coronal plane malalignment. We analyzed the change in coronal alignment induced by tray malrotation.

Methods

We constructed a computer model of knee arthroplasty and used a virtual cutting guide to cut the tibia at 90° to the coronal plane. The virtual guide was rotated axially (15° medial to 15° lateral) and with posterior slopes (0° to 7°). To assess the effect of axial malrotation, we measured the coronal plane alignment of a tibial tray that was axially rotated (25° internal to 15° external), as viewed on a standard anteroposterior (AP) radiograph.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 15 - 15
1 Mar 2012
Verghese N Joshy S Cronin M Forster MC Robertson A
Full Access

Recently biodegradable synthetic scaffolds (Trufit plug) have provided novel approach to the management of chondral and osteochondral lesions. The aim of this study was to assess our 2 year experience with the Trufit plug system. 22 patients aged 20 to 50 years old all presenting with knee pain over a 2 year period were diagnosed either by MRI or arthroscopically with an isolated chondral or osteochondral lesion and proceeded to either arthroscopic or mini arthrotomy Trufit plug implantation. In 5 patients plug implantation was undertaken along with ACL reconstruction (3), medial meniscal repair (1) and contralateral knee OCD screw fixation (1). Pre and post operative IKDC scores were obtained to assess change in knee symptoms and function. At a mean follow up of 15 months (range 2 – 24 months) improved IKDC scores were achieved with the scores improving with time. 2 patients have had a poor result and have had further surgery for their chondral lesions. One patient had failure of graft incorporation at second look arthroscopy and went onto to have a good result after ACI. The second patient had good graft incorporation on second look but had progression of osteoarthritic degeneration throughout the other compartments of the knee which were not initially identified at the time of Trufit plugging. We conclude that Trufit plug is an alternative method for managing isolated chondral and osteochondral lesions of the knee which avoids harvest site morbidity or the need for staged surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 66 - 66
1 Jul 2012
Anand BS Krishnan BH Houilhan-Burne D
Full Access

Purpose. We conducted a prospective study to investigate the role of the LARS ligament system to reconstruct the posterior cruciate ligament and the postero-lateral corner of the knee. We present a prospective single surgeon case series to evaluate early clinical and functional outcomes of postero-lateral corner and posterior cruciate ligament reconstruction in the knee using the LARS (ligament Augmentation and Reconstruction System) artificial ligament. 23 patients with multi-ligament knee injuries or isolated PCL injuries were treated with a mean follow up of 8 months (range: 2-37 months). Outcomes were assessed using the modified International Knee Documentation Committee score, and a modified Tegner- Lysholm score. 2 patients had acute reconstructive surgery within 7 days of injury, 5 patients within 3 months (semi-acute) and 16 were chronic cases that were operated on after three months from the date of injury. The LARS ligament reconstruction achieved a significant improvement between preoperative and postoperative assessment in relation to knee stability, function and patient satisfaction. The sooner the patients were treated the greater the improvements in functional scores were noted. Most patients achieved a full functional range of movement within six months. We had 2 complications, one superficial wound infection and one stiff knee requiring a manipulation. To date we have had no LARS ligament failures. In the short term the LARS functions well, with high clinical patient satisfaction, no signs of progressive laxity, synovitis or failure. We found no significant difference in functional score post reconstruction between the isolated PCL reconstructions and the multi ligament reconstructions. Our results show no early signs of the problems associated with synthetic grafts used in the past. Such grafts appear to be an attractive alternative to the use of autografts and allografts


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 21 - 21
1 Mar 2012
Sharda P Alshryda S Shetty A Kalia P Nargol A Maheswaran S
Full Access

PURPOSE OF STUDY. 20-70% of patients need blood transfusion postoperatively. There remain safety concerns regarding allogenic blood transfusion. Tranexamic acid (TA) is a synthetic antifibrinolytic agent that has been successfully used to stop bleeding in other specialties. We applied TA topically prior to the wound closure to find out the effect on blood loss as well as need for subsequent blood transfusion. This method of administration is quick, easy, has less systemic side effect and provides a higher concentration at the bleeding site. MATERIALS AND METHODS. A double blind randomised controlled trial of 154 patients who underwent unilateral primary cemented total knee replacement. Patients were randomised into tranexamic acid group (1g drug mixed with saline to make up 20mls) or placebo (20ml 0.9% saline). The administration technique and drain protocol was standardised for all patients. Drain output was measured at 24 hours, and both groups compared for need of Blood transfusion. Outcome measures - blood loss, transfusion, complications, Euroqol and Oxford Knee Score. RESULTS. The two groups were comparable in age, weight, height, BMI, and Tourniquet time. There was significant difference in the amount of blood loss and blood transfusion in favour of tranexamic acid (p=0.001 and 0.007 respectively). Fourteen patients needed blood transfusion (ranged from 2 to 6 units). Thirteen were in the Placebo group and only one in the Tranexamic acid. There was no significant difference among other outcomes, in particular complications rates such as DVT and PE. Use of Tranexamic acid is recommended as routine to reduce bleeding and blood transfusion rates following primary Total Knee replacement


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 19 - 19
1 Jul 2012
Yasen S Melton J Wilson A
Full Access

Background. The management of chondral lesions in the knee, especially in young fit patients, remains an area of considerable controversy. Articular cartilage repair or reconstruction techniques may offer these patients alternatives to arthroplasty or realignment osteotomy. The TruFit plug (Smith & Nephew, London, UK) is a synthetic biphasic polymer scaffold that is designed for implantation at the site of a focal chondral defect. It is intended to resorb and allow tissue ingrowth 6-9 months following implantation and may be placed either arthroscopically or via an open approach depending on the site of the lesion. Methods. 11 patients with focal chondral defects in the knee underwent TruFit plug implantation. Postoperative management entailed a period of 6 weeks of restricted weight bearing or restricted knee flexion according to implantation site. Radiological evaluation with MRI or CT arthrogram (or both) was conducted at various time points postoperatively according to clinical indication. Functional scoring with the Oxford knee score (OKS), Tegner activity scale and Lysholm score were completed. Results. 35 TruFit plugs were implanted in 12 knees of 11 patients (4 men, 7 women) between June 2007 and December 2009. Mean age at time of surgery 46.9 years (range32-72years). Mean change in OKS 1.33 (range -13 to 29), Lysholm 13.8 (range -19 to 61), Tegner 0.33 (range -2 to 2 levels). Imaging characteristics on MRI and CT arthrogram show delayed incorporation of the grafts in all patients with no osseous integration at up to 24 months follow up. Conclusions. Early results from the TruFit plug show variable functional outcome scores which appear independent of patient age, number of plugs used and site of implantation. All show delayed tissue integration. Our group is currently not implanting any further TruFit plugs pending longer term outcomes from larger case series


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 93 - 93
1 Jul 2012
Kempshall P Guro R Lewis M Mintowt-Czyz W Chandratreya A Roy W
Full Access

Aims. Wales in collaboration with the Welsh Assembly Government, has attempted to start a national ligament register. Introduction. Norway is the lead in Europe for running a successful national quality knee ligament registry. As yet there is no UK wide registry encompassing all forms of knee ligament surgery. The issue has been discussed at previous society meetings, but no consensus has been reached. Method. A pilot study covering three NHS Trusts in South Wales was run between April 2010 and September 2010. Data is gathered prospectively on non-operatively treated and surgically treated knee ligament injuries performed in the regions. This data is recorded on the WKLR form which is then sent to the WKLR centre and entered onto a secure database. Four knee surgeons agreed to take part in the study, from three NHS Health Boards. The data is recorded at the time of the operation on a tick box form akin to that used by the NJR. The prospectively gathered data is stored at the central registry office in Princess of Wales Hospital Bridgend. Results. A total of 68 forms were returned to the registry, 58 Males and 10 Females, average age 30 and 35 years respectively. Four per cent of ACL ruptures were treated non-operatively. Sixty two (96%) ACL ruptures were reconstructed; 57 primary reconstructions; 3 revisions; 2 were multi-ligament injuries. The most common mechanisms of injury in females were basketball and football. Rugby was the most common mechanism for males. Six PCL injuries were reported, half (3) were reconstructed, all using allograft Achilles tendon. Of the fifty seven primary ACL reconstructions, twenty nine (47%) ACL reconstructions were recorded with no meniscal injury, thirty (53%) of ACL reconstructions had concomitant meniscal injury, which equates to 8% requiring repair (5 medial, 1 lateral) and 25 (43%) requiring meniscectomy for non-repairable tears (15 medial, 10 Lateral). Cartilage lesions were seen in 18 reconstructions (27%). Of these 2 (3%) had synthetic mosaic plasty. Four lesions (6%) had chondroplasty and the remaining 12 (18%) treatment was not required but noted. Conclusion. The WKLR, although in its infancy, has shown that a ‘National Quality Database’ of this type is feasible and will provide the necessary quality assurance demanded by this active young group of patients. The WKLR will provide an invaluable research tool for assessing and comparing outcomes of the various techniques, graft types, and fixation devices. Failing implants can be identified early. Under performing institutions can be identified, and performance can be compared to the national average. All of these aims are focused at improving patient safety, satisfaction and outcome


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1238 - 1247
1 Oct 2019
Soreide E Denbeigh JM Lewallen EA Thaler R Xu W Berglund L Yao JJ Martinez A Nordsletten L van Wijnen AJ Kakar S

Aims

Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function.

Materials and Methods

A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6).


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 151 - 157
1 Jun 2020
Gil D Atici AE Connolly RL Hugard S Shuvaev S Wannomae KK Oral E Muratoglu OK

Aims

We propose a state-of-the-art temporary spacer, consisting of a cobalt-chrome (CoCr) femoral component and a gentamicin-eluting ultra-high molecular weight polyethylene (UHMWPE) tibial insert, which can provide therapeutic delivery of gentamicin, while retaining excellent mechanical properties. The proposed implant is designed to replace conventional spacers made from bone cement.

Methods

Gentamicin-loaded UHMWPE was prepared using phase-separated compression moulding, and its drug elution kinetics, antibacterial, mechanical, and wear properties were compared with those of conventional gentamicin-loaded bone cement.


Bone & Joint Research
Vol. 8, Issue 2 | Pages 65 - 72
1 Feb 2019
Cowie RM Aiken SS Cooper JJ Jennings LM

Objectives

Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation.

Methods

A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 438 - 442
1 Oct 2019
Kayani B Haddad FS