Abstract. Introduction. The Syn-VAR RCT is the first of its kind comparing hamstrings autograft v
Abstract. Introduction. The aim of this study was to determine if elite athletes could return to professional sport after MCL or PLC reconstruction using LARS ligaments and to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries and complications. Methods. A retrospective review of all extra-articular knee ligament reconstructions in elite athletes utilising LARS ligaments by 3 knee surgeons between January 2013 and October 2020 was undertaken. Return to play (RTP) was defined as competing at professional level or national/ international level in amateur sport. Results. Sixty-four (84.2%) MCL and 12 (15.8%) PLC reconstructions utilising LARS in elite athletes were included. 52 (68.4%) underwent concomitant cruciate(s) reconstruction. The mean age was 25.1 years (SD +/− 4.50. Most were football (35, 46.1%) or rugby players (35, 46.1%). Sixty-seven athletes (88.2%) RTP with 65 (97.0%) of these playing at the same or higher Tegner level. 56 (83.6%) and 20 (57.1%) were still playing at 2 and 5 years post-surgery. Six (7.9%) players (5 of whom RTP) required further surgery relating to the LARS / metalwork and there was one case of adverse local inflammatory reaction to the
Purposes of the study. To assess the performance of an acellular
Abstract. Introduction. Traumatic knee dislocations are devastating injuries and there is no single best accepted treatment. This study looked at functional outcome of a single surgeon case series of patients who underwent surgical management of their knee dislocation. Methods. Eighty-seven patients with knee dislocation were treated at a major trauma centre. Acute surgical repair and reconstruction with fracture fixation within 4 weeks was preferred unless the patient was too unstable (Injury severity score>16). The collaterals were repaired and augmented using a variety of autografts, allografts or
Patient dissatisfaction following primary total knee arthroplasty (TKA) with manual jig-based instruments has been reported to be as high as 30%. Robotic-assisted total knee arthroplasty (RA-TKA) has been increasingly used in an effort to improve patient outcomes, however there is a paucity of literature examining patient satisfaction after RA-TKA. This study aims to identify the incidence of patients who were not satisfied following RA-TKA and to determine factors associated with higher levels of dissatisfaction. This was a retrospective review of 674 patients who underwent primary TKA between October 2016 and September 2020 with a minimum two-year follow-up. A five-point Likert satisfaction score was used to place patients into two groups: Group A were those who were very dissatisfied, dissatisfied, or neutral (Likert score 1 to 3) and Group B were those who were satisfied or very satisfied (Likert score 4 to 5). Patient demographic data, as well as preoperative and postoperative patient-reported outcome measures, were compared between groups.Aims
Methods
As many as 25% to 40% of unicompartmental knee
replacement (UKR) revisions are performed for pain, a possible cause
of which is proximal tibial strain. The aim of this study was to
examine the effect of UKR implant design and material on cortical
and cancellous proximal tibial strain in a
The aim of this study was to compare patient-reported outcomes (PROMs) following isolated anterior cruciate ligament reconstruction (ACLR), with those following ACLR and concomitant meniscal resection or repair. We reviewed prospectively collected data from the UK National Ligament Registry for patients who underwent primary ACLR between January 2013 and December 2022. Patients were categorized into five groups: isolated ACLR, ACLR with medial meniscus (MM) repair, ACLR with MM resection, ACLR with lateral meniscus (LM) repair, and ACLR with LM resection. Linear regression analysis, with isolated ACLR as the reference, was performed after adjusting for confounders.Aims
Methods
The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95th percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone.Aims
Methods
One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD).Aims
Methods
Meniscal injuries are common and often induce knee pain requiring surgical intervention. To develop effective strategies for meniscus regeneration, we hypothesized that a minced meniscus embedded in an atelocollagen gel, a firm gel-like material, may enhance meniscus regeneration through cell migration and proliferation in the gel. Hence, the objective of this study was to investigate cell migration and proliferation in atelocollagen gels seeded with autologous meniscus fragments in vitro and examine the therapeutic potential of this combination in an in vivo rabbit model of massive meniscus defect. A total of 34 Japanese white rabbits (divided into defect and atelocollagen groups) were used to produce the massive meniscus defect model through a medial patellar approach. Cell migration and proliferation were evaluated using immunohistochemistry. Furthermore, histological evaluation of the sections was performed, and a modified Pauli’s scoring system was used for the quantitative evaluation of the regenerated meniscus.Aims
Methods
The extensive variation in axial rotation of tibial components can lead to coronal plane malalignment. We analyzed the change in coronal alignment induced by tray malrotation. We constructed a computer model of knee arthroplasty and used a virtual cutting guide to cut the tibia at 90° to the coronal plane. The virtual guide was rotated axially (15° medial to 15° lateral) and with posterior slopes (0° to 7°). To assess the effect of axial malrotation, we measured the coronal plane alignment of a tibial tray that was axially rotated (25° internal to 15° external), as viewed on a standard anteroposterior (AP) radiograph.Aims
Methods
Recently biodegradable
Purpose. We conducted a prospective study to investigate the role of the LARS ligament system to reconstruct the posterior cruciate ligament and the postero-lateral corner of the knee. We present a prospective single surgeon case series to evaluate early clinical and functional outcomes of postero-lateral corner and posterior cruciate ligament reconstruction in the knee using the LARS (ligament Augmentation and Reconstruction System) artificial ligament. 23 patients with multi-ligament knee injuries or isolated PCL injuries were treated with a mean follow up of 8 months (range: 2-37 months). Outcomes were assessed using the modified International Knee Documentation Committee score, and a modified Tegner- Lysholm score. 2 patients had acute reconstructive surgery within 7 days of injury, 5 patients within 3 months (semi-acute) and 16 were chronic cases that were operated on after three months from the date of injury. The LARS ligament reconstruction achieved a significant improvement between preoperative and postoperative assessment in relation to knee stability, function and patient satisfaction. The sooner the patients were treated the greater the improvements in functional scores were noted. Most patients achieved a full functional range of movement within six months. We had 2 complications, one superficial wound infection and one stiff knee requiring a manipulation. To date we have had no LARS ligament failures. In the short term the LARS functions well, with high clinical patient satisfaction, no signs of progressive laxity, synovitis or failure. We found no significant difference in functional score post reconstruction between the isolated PCL reconstructions and the multi ligament reconstructions. Our results show no early signs of the problems associated with
PURPOSE OF STUDY. 20-70% of patients need blood transfusion postoperatively. There remain safety concerns regarding allogenic blood transfusion. Tranexamic acid (TA) is a
Background. The management of chondral lesions in the knee, especially in young fit patients, remains an area of considerable controversy. Articular cartilage repair or reconstruction techniques may offer these patients alternatives to arthroplasty or realignment osteotomy. The TruFit plug (Smith & Nephew, London, UK) is a
Aims. Wales in collaboration with the Welsh Assembly Government, has attempted to start a national ligament register. Introduction. Norway is the lead in Europe for running a successful national quality knee ligament registry. As yet there is no UK wide registry encompassing all forms of knee ligament surgery. The issue has been discussed at previous society meetings, but no consensus has been reached. Method. A pilot study covering three NHS Trusts in South Wales was run between April 2010 and September 2010. Data is gathered prospectively on non-operatively treated and surgically treated knee ligament injuries performed in the regions. This data is recorded on the WKLR form which is then sent to the WKLR centre and entered onto a secure database. Four knee surgeons agreed to take part in the study, from three NHS Health Boards. The data is recorded at the time of the operation on a tick box form akin to that used by the NJR. The prospectively gathered data is stored at the central registry office in Princess of Wales Hospital Bridgend. Results. A total of 68 forms were returned to the registry, 58 Males and 10 Females, average age 30 and 35 years respectively. Four per cent of ACL ruptures were treated non-operatively. Sixty two (96%) ACL ruptures were reconstructed; 57 primary reconstructions; 3 revisions; 2 were multi-ligament injuries. The most common mechanisms of injury in females were basketball and football. Rugby was the most common mechanism for males. Six PCL injuries were reported, half (3) were reconstructed, all using allograft Achilles tendon. Of the fifty seven primary ACL reconstructions, twenty nine (47%) ACL reconstructions were recorded with no meniscal injury, thirty (53%) of ACL reconstructions had concomitant meniscal injury, which equates to 8% requiring repair (5 medial, 1 lateral) and 25 (43%) requiring meniscectomy for non-repairable tears (15 medial, 10 Lateral). Cartilage lesions were seen in 18 reconstructions (27%). Of these 2 (3%) had
Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function. A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6).Aims
Materials and Methods
We propose a state-of-the-art temporary spacer, consisting of a cobalt-chrome (CoCr) femoral component and a gentamicin-eluting ultra-high molecular weight polyethylene (UHMWPE) tibial insert, which can provide therapeutic delivery of gentamicin, while retaining excellent mechanical properties. The proposed implant is designed to replace conventional spacers made from bone cement. Gentamicin-loaded UHMWPE was prepared using phase-separated compression moulding, and its drug elution kinetics, antibacterial, mechanical, and wear properties were compared with those of conventional gentamicin-loaded bone cement.Aims
Methods
Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation. A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry.Objectives
Methods