Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 1 - 1
23 Feb 2023
Chong S Khademi M Reddy K Anderson G
Full Access

Treatment of posterior malleolar (PM) ankle fractures remain controversial. Despite increasing recommendation for small PM fragment fixation, high quality evidence demonstrating improved clinical outcomes over the unfixated PM is limited. We describe the medium-to-long term clinical and radiographical outcomes in younger adult patients with PM ankle fractures managed without PM fragment fixation. A retrospective cohort study of patients aged 18–55 years old admitted under our orthopaedic unit between 1st of April 2009 and 31st of October 2013 with PM ankle fractures was performed. Inclusion criteria were that all patients must mobilise independently pre-trauma, have no pre-existing ankle pathologies, and had satisfactory bimalleolar and syndesmotic stabilisation. Open fractures, talar fractures, calcaneal fractures, pilon fractures, subsequent re-injury and major complications were excluded. All PM fragments were unfixated. Clinical outcomes were evaluated using Foot and Ankle Ability Measure (FAAM) with activities of daily living (ADL) and sports subscale, visual analogue scale (VAS) and patient satisfaction ratings. Osteoarthrosis was assessed using modified Kellgren-Lawrence scale on updated weightbearing ankle radiographs. 61 participants were included. Mean follow-up was 10.26 years. Average PM size was 16.19±7.39%. All participants were evaluated for clinical outcomes, demonstrating good functional outcomes (FAAM-ADL 95.48±7.13; FAAM-Sports 86.39±15.52) and patient satisfaction (86.16±14.42%), with minimal pain (VAS 1.13±1.65). Radiographical outcomes were evaluated in 52 participants, showing no-to-minimal osteoarthrosis in 36/52 (69.23%), mild osteoarthrosis in 14/52 (26.92%) and moderate osteoarthrosis in 2/52 (3.85%). Clinical outcomes were not associated with PM fragment size, post-reduction step-off, dislocation, malleoli fractured or syndesmotic injury. PM step-off and dislocation were associated with worse radiographical osteoarthrosis. Other published medium-to-long term studies reported overall good outcomes, with no differences after small fragment fixation. The unfixated smaller posterior malleolus fragment demonstrated overall satisfactory clinical and radiographical outcomes at 10-year follow-up and may be considered a valid treatment strategy


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 105 - 105
1 Dec 2022
Hébert S Charest-Morin R Bédard L Pelet S
Full Access

Despite the current trend favoring surgical treatment of displaced intra-articular calcaneal fractures (DIACFs), studies have not been able to demonstrate superior functional outcomes when compared to non-operative treatment. These fractures are notoriously difficult to reduce. Studies investigating surgical fixation often lack information about the quality of reduction even though it may play an important role in the success of this procedure. We wanted to establish if, amongst surgically treated DIACF, an anatomic reduction led to improved functional outcomes at 12 months. From July 2011 to December 2020, at a level I trauma center, 84 patients with an isolated DIACF scheduled for surgical fixation with plate and screws using a lateral extensile approach were enrolled in this prospective cohort study and followed over a 12-month period. Post-operative computed tomography (CT) imaging of bilateral feet was obtained to assess surgical reduction using a combination of pre-determined parameters: Böhler's angle, calcaneal height, congruence and articular step-off of the posterior facet and calcaneocuboid (CC) joint. Reduction was judged anatomic when Böhler's angle and calcaneal height were within 20% of the contralateral foot while the posterior facet and CC joint had to be congruent with a step-off less than 2 mm. Several functional scores related to foot and ankle pathology were used to evaluate functional outcomes (American Orthopedic Foot and Ankle Score - AOFAS, Lower Extremity Functional Score - LEFS, Olerud and Molander Ankle Score - OMAS, Calcaneal Functional Scoring System - CFSS, Visual Analog Scale for pain - VAS) and were compared between anatomic and nonanatomic DIAFCs using Student's t-test. Demographic data and information about injury severity were collected for each patient. Among the 84 enrolled patients, 6 were excluded while 11 were lost to follow-up. Thirty-nine patients had a nonanatomic reduction while 35 patients had an anatomic reduction (47%). Baseline characteristics were similar in both groups. When we compared the injury severity as defined by the Sanders’ Classification, we did not find a significant difference. In other words, the nonanatomic group did not have a greater proportion of complex fractures. Anatomically reduced DIACFs showed significantly superior results at 12 months for all but one scoring system (mean difference at 12 months: AOFAS 3.97, p = 0.12; LEFS 7.46, p = 0.003; OMAS 13.6, p = 0.002, CFSS 7.5, p = 0.037; VAS −1.53, p = 0.005). Univariate analyses did not show that smoking status, worker's compensation or body mass index were associated with functional outcomes. Moreover, fracture severity could not predict functional outcomes at 12 months. This study showed superior functional outcomes in patients with a DIACF when an anatomic reduction is achieved regardless of the injury severity


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 70 - 70
1 Dec 2022
Hébert S Charest-Morin R Bédard L Pelet S
Full Access

Despite the current trend favoring surgical treatment of displaced intra-articular calcaneal fractures (DIACFs), studies have not been able to demonstrate superior functional outcomes when compared to non-operative treatment. These fractures are notoriously difficult to reduce. Studies investigating surgical fixation often lack information about the quality of reduction even though it may play an important role in the success of this procedure. We wanted to establish if, amongst surgically treated DIACF, an anatomic reduction led to improved functional outcomes at 12 months. From July 2011 to December 2020, at a level I trauma center, 84 patients with an isolated DIACF scheduled for surgical fixation with plate and screws using a lateral extensile approach were enrolled in this prospective cohort study and followed over a 12-month period. Post-operative computed tomography (CT) imaging of bilateral feet was obtained to assess surgical reduction using a combination of pre-determined parameters: Böhler's angle, calcaneal height, congruence and articular step-off of the posterior facet and calcaneocuboid (CC) joint. Reduction was judged anatomic when Böhler's angle and calcaneal height were within 20% of the contralateral foot while the posterior facet and CC joint had to be congruent with a step-off less than 2 mm. Several functional scores related to foot and ankle pathology were used to evaluate functional outcomes (American Orthopedic Foot and Ankle Score - AOFAS, Lower Extremity Functional Score - LEFS, Olerud and Molander Ankle Score - OMAS, Calcaneal Functional Scoring System - CFSS, Visual Analog Scale for pain – VAS) and were compared between anatomic and nonanatomic DIAFCs using Student's t-test. Demographic data and information about injury severity were collected for each patient. Among the 84 enrolled patients, 6 were excluded while 11 were lost to follow-up. Thirty-nine patients had a nonanatomic reduction while 35 patients had an anatomic reduction (47%). Baseline characteristics were similar in both groups. When we compared the injury severity as defined by the Sanders’ Classification, we did not find a significant difference. In other words, the nonanatomic group did not have a greater proportion of complex fractures. Anatomically reduced DIACFs showed significantly superior results at 12 months for all but one scoring system (mean difference at 12 months: AOFAS 3.97, p = 0.12; LEFS 7.46, p = 0.003; OMAS 13.6, p = 0.002, CFSS 7.5, p = 0.037; VAS −1.53, p = 0.005). Univariate analyses did not show that smoking status, worker's compensation or body mass index were associated with functional outcomes. Moreover, fracture severity could not predict functional outcomes at 12 months. This study showed superior functional outcomes in patients with a DIACF when an anatomic reduction is achieved regardless of the injury severity


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 66 - 66
1 Sep 2012
Heesterbeek P Labey L Wong P Innocenti B Wyemnga A
Full Access

Introduction. After total knee arthroplasty (TKA) with a PCL-retaining implant the location of the tibiofemoral contact point should be restored in order to obtain normal kinematics. The difficulty during surgery is to control this location since the position of the femur on the tibia cannot easily be measured from the back of the joint. Therefore, we developed a simple “spacer technique” to check the contact point indirectly in 90° flexion after all bone cuts are made by measuring the step-off between the distal cut of the femur and the anterior edge of the tibia with a spacer in place. The goal of this experiment was to investigate whether this new PCL balancing approach with the spacer technique created the correct contact point location. Methods. Nine fresh-frozen full leg cadaver specimens were used. After native testing, prototype components of a new PCL-retaining implant were implanted using navigation and a bone-referenced technique. After finishing the bone cuts of tibia and femur, the spacer was inserted in flexion and positioned on the anterior edge of the bony surface to measure the step-off. If necessary, an extra cut was made to balance the PCL. The specimen was mounted on the knee kinematics rig and a squat with constant vertical ankle force (130N) and constant medial and lateral hamstrings forces (50N) was performed between 30° and 130° of knee flexion. The trajectories of the reflective tibial and femoral markers were continuously recorded using six infrared cameras. The projections of the femoral condylar centers on the horizontal plane of the tibia were calculated and compared. Results. Of the 9 specimens, the calculated step-off was correct in 7 after finishing the bone cuts and in 2 specimens an additional tibia cut with 2–3 degrees more slope was sufficient to achieve the correct step-off. No lift-off of the tibial tray occurred during the tests. The patterns of the kinematics of the native and replaced knee showed a considerable similarity (fig 1). The projected medial femoral condylar center of the knee implant is at the same position as the projected medial femoral condylar center of the native knee. No paradoxical roll forward is seen in the knee implants, showing that the PCL balancing apparently seems to work quite well. The projected lateral femoral condylar center of the knee has a similar kinematic pattern in flexion before and after TKA. The knee implant shows a slightly more anterior location near extension but this is only marginal. Discussion and conclusion. The kinematics of the PCL-retaining implant are on average comparable to the kinematic pattern of the native knee. Apparently, the joint surfaces of the anatomic knee designed with a dished medial insert surface and a convex lateral insert surface and a 3 degrees varus of the joint line is guiding the motion towards that of a normal knee joint. We feel that correct balancing of the PCL during implantation is of major importance in achieving these results. The spacer technique to balance the PCL seems to work well in this experiment