We report a prospective study of the use of intramedullary bone blocks to improve the fixation of a matt-finish femoral stem in Charnley low-friction arthroplasties. There were 379 patients (441 hips), but at a minimum follow-up of ten years there were 258 arthroplasties in 221 patients including some which had been revised. The mean age at surgery was 41 years (17 to 51) and the mean follow-up was 13.4 years (1 to 20 including the early revisions). Nine stems (3.5%) had been revised for aseptic loosening, but there were no stem fractures. Survivorship of stems was 99.2% at ten years and 94.35% at 15 and 20 years. We found that the patient’s gender, the position of the stem and the experience of the surgeon all influenced the outcome. Our findings suggest that using our method of
To achieve the functional benefits of the direct anterior (DA) approach and the fixation benefits of cemented replacement, this study combined the two techniques posing the following questions: does the limited access of the DA approach adversely affect the cement technique?; and does such a cementing technique reduce the incidence of cementless complications? A consecutive series of 341 patients (360 hips) receiving the DA approach between 2016 and 2018 were reviewed. There were 203 cementless stems and 157 cemented stems. Mean age was 75 years (70 to 86) in the cementless group and 76 years (52 to 94) in the cemented group, with 239 (70%) females in the whole series. Femoral complications were compared between the two groups. Mean follow-up was 1.5 years (0.1 to 4.4) for patients in the cementless group and 1.3 years (0.0 to 3.9) for patients in the cemented group.Aims
Methods
The early revision rate in elective Total Hip Arthroplasty (THA) three years after surgery in elderly patients over 80 years is significantly lower for cemented stems in the German Arthroplasty Register (EPRD): cemented 3,1% (3.0 – 3.2) vs. uncemented 4.2% (4.1 – 4.3; p < 0.001). However, the mortality rate in elderly patients is elevated for cemented fixation. This study presents a detailed analysis of the influence of stem type and fixation on revision and mortality rate in this patient cohort. Elective primary THA cases for primary Coxarthrosis using uncemented cups from the EPRD data base were analysed (n0= 37,183). Four stem type groups were compared: cementless, cementless with collar, cementless short, and cemented. Stems with at least 300 cases at risk three years after surgery were analysed individually. The reference stem was determined as the stem with the lowest revision rate and at least 1000 cases under surveillance 3 years after surgery (n3 = 28,637). The revision rate for cemented stems (2.5% [2.2–1.81] was lower than for uncemented (4.5% [4.2–4.9]; p<0.001) and uncemented short stems (4.2% [3.1–5.7]; p=0.002). The revision rate of uncemented collared stems (2.3% [1.5–3.6]) was similar to cemented stems (p=0.89) and lower than for uncemented stems (p=0.02). One year mortality showed no sig. differences between the groups (p>0.17): cemented 3.2% [2.9–3.6], uncemented 3.4% [3.1–3.7], uncemented short 3.5% [2.5–4.9], uncemented collar 2.0% [1.2–3.2]. “Cementless” and “cementless short” stems should not be used in patients over 80 years due to the higher revision risk. If cementing should be avoided, “cementless collared” stems seem to be a good alternative combined with a tendency for a lower one year mortality rate.
The acknowledged benefit of the direct anterior (DA) approach is early functional return. Most surgeons in the U.S. use cementless femoral replacement given the negative track record of some cemented designs. However, delayed osseointegration of a femoral stem typically seen in older patients with poor bone quality will delay recovery, diminishing the benefits of the DA approach. Registry studies have shown a higher revision rate and complications in this patient population leading to a renewed interest in cemented fixation. To achieve the functional benefits of the DA approach and the fixation benefits of cemented replacement, this study combined the 2 techniques posing the following questions:1) Does the limited access of the DA approach adversely affect the cement technique? 2) Does such a cementing technique reduce the incidence of cementless complications?Background
Questions posed
The calcar femorale is a vertical plate of bone lying deep to the lesser trochanter and is formed as a result of traction of the iliopsoas which separates the femoral cortex into two distinct layers, the calcar femorale and the medial femoral cortex. They fuse together proximally to form the medial femoral neck. A stem placed centrally will abut against the calcar femorale with little or no space for cement. Clearing of the calcar will offer space for a cement layer, which will support the stem proximally on the posterior aspect. We compared two consecutive groups of Charnley low-friction arthroplasties, with and without clearing of the calcar. In 330 patients who had an arthroplasty without clearing the calcar, there were ten revisions for aseptic loosening of the stem and six other stems were considered ‘definitely loose’, giving a rate of failure of 4.8%. In 111 patients in whom the calcar was cleared there was only one revision for aseptic loosening and no stems were classed as ‘definitely loose’, giving a rate of failure of 0.9%. Survivorship analysis has again shown the need for long-term follow-up; the differences became clear after ten years but because of the relatively small numbers, statistical analysis is not yet applicable. We now clear the calcar femorale routinely and advocate optimal access to the medullary canal and insertion of the stem in the area of the piriform fossa.
Aims. To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs). Methods. In this registry study, data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man (NJR) were linked with manufacturing data supplied by manufacturers. The primary endpoint was revision of any component. Cox proportional hazard regression was a primary analytic approach adjusting for competing risk of death, patient characteristics, head composition, and
Aims. Osteoporosis can determine surgical strategy for total hip arthroplasty (THA), and perioperative fracture risk. The aims of this study were to use hip CT to measure femoral bone mineral density (BMD) using CT X-ray absorptiometry (CTXA), determine if systematic evaluation of preoperative femoral BMD with CTXA would improve identification of osteopenia and osteoporosis compared with available preoperative dual-energy X-ray absorptiometry (DXA) analysis, and determine if improved recognition of low BMD would affect the use of cemented
Aims. Revision total hip arthroplasty in patients with Vancouver type B3 fractures with Paprosky type IIIA, IIIB, and IV femoral defects are difficult to treat. One option for Paprovsky type IIIB and IV defects involves modular cementless, tapered, revision femoral components in conjunction with distal interlocking screws. The aim of this study was to analyze the rate of reoperations and complications and union of the fracture, subsidence of the stem, mortality, and the clinical outcomes in these patients. Methods. A total of 46 femoral components in patients with Vancouver B3 fractures (23 with Paprosky type IIIA, 19 with type IIIB, and four with type IV defects) in 46 patients were revised with a transfemoral approach using a modular, tapered, cementless revision Revitan curved femoral component with distal cone-in-cone fixation and prospectively followed for a mean of 48.8 months (SD 23.9; 24 to 112). The mean age of the patients was 80.4 years (66 to 100). Additional distal interlocking was also used in 23 fractures in which distal cone-in-cone fixation in the isthmus was < 3 cm. Results. One patient (2.2%) died during the first postoperative year. After six months, 43 patients (93.5%) had osseous, and three had fibrous consolidation of the fracture and the bony flap, 42 (91.3%) had bony ingrowth and four had stable fibrous
Aims. This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and
Introduction. In the United States, cementless femoral fixation remains the dominant mode of fixation for femoral neck fractures, despite strong worldwide registry data that supports cemented fixation. The reason for this discrepancy remains unknown, controversial and often difficult to compare due to multiple variables. The purpose of this study was to evaluate a matched cohort of patients undergoing arthroplasty for femoral neck fractures and assess outcomes of revisions, periprosthetic fractures and mortality. Methods. This is an exact matched cohort study. Cemented fixation cases were exact matched to cementless fixation cases in a 1:1 fashion based on age, sex and Charlson Comorbidity Index (CCI). Outcome variables included: revision for periprosthetic fracture; all cause revision and mortality at any time point; all cause revision and mortality within 1-year and within 90-days. The primary independent variable was femoral fixation (cemented, cementless) and covariates included race (black, white, other), ethnicity (hispanic, non-hispanic), teaching status (minor, major, nonteaching) and bedsize (1–99, 100–399, >=400). Chi-square tests and multivariable logistic regression models were used for statistical analysis. Results. A total of 64,283 femoral neck fractures were evaluated. 17,138 cementless femoral stems were matched exactly to cemented femoral stems based on age, gender and Charleston comorbidity index (CCI). In the multivariate logistic regression analysis, compared to cementless femoral fixation, cemented fixation was associated with a 20% reduction in overall revision (OR 0.796, 0.675–0.939), a 30% reduction in revision at 1 year (OR: 0.709, 0.589–0.854) and a 86% reduction in revision for periprosthetic fracture (OR: 0.144, 0.07–0.294). However, cemented
Introduction. Patients with FNF may be treated by either total hip arthroplasty (THA) or hemiarthroplasty (HA). Utilizing American Joint Replacement Registry (AJRR) data, we aimed to evaluate outcomes in FNF treatment. Methods. Medicare patients with FNF treated with HA or THA reported to the AJRR database from 2012–2019 and CMS claims data from 2012–2017 were analyzed in this retrospective cohort study. “Early” was defined as less than 90 days from index procedure. A logistic regression model, including index arthroplasty, age, sex,
Aims. BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems. Methods. A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery. Results. At three months, the mean total translation (TT) was 0.95 mm (95% confidence interval (CI) 0.68 to 1.22) in the P group and 0.57 mm (95% CI 0.31 to 0.83) in the PBM group (p = 0.047). From two to five years, the TT increased by a mean of 0.14 mm (95% CI 0.03 to 0.25) more in the P group than in the PBM group (p = 0.021). In osteopenic patients (n = 20), the mean TT after three months was 1.61 mm (95% CI 1.03 to 2.20) in the P group and 0.73 mm (95% CI 0.25 to 1.21) in the PBM group (p = 0.023). After 60 months, the mean TT in osteopenic patients was 1.87 mm (95% CI 1.24 to 2.50) in the P group and 0.82 mm (95% CI 0.30 to 1.33) in the PBM group (p = 0.011). Conclusion. There was less early and midterm migration of cementless stems with BoneMaster coating compared with those with only a porous titanium plasma-sprayed coating. Although a BoneMaster coating seems to be important for
Our previous work presented at BHS revealed a reduced risk of revision for all reasons in THAs using lipped (asymmetric) liners. Some audience members felt that this finding may be due to unaccounted confounders and the hip surgery community remains sceptical. A fully adjusted Cox model was built after exploratory Kaplan-Meier analyses. The following surgical approaches were included in the analysis: Posterior, Hardinge/anterolateral, Other. The variables included in the final Cox model included: Gender, liner asymmetry, age, head composition,
Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems. Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and
Aim. To assess the effect of the bearing surface and head size on the survival of total hip replacements with modern bearing surface combinations. Methods. We combined the NJR dataset with polyethylene manufacturing properties as supplied by the manufacturers to sub-divide polyethylene into conventional (PE) and highly crosslinked (XLPE). Cause specific and overall reasons for revisions were analysed using Kaplan-Meier and multi-variate Cox proportional hazard regression survival analyses. The bearing surface analysis was repeated in patients undergoing THR under the age of 55. Results. A total of 337,786 primary THR cases were included with an associated 5,618 revisions. Head size was grouped in <= 28mm (group A), 32mm (group B) and >=36mm (group C). A Cox regression model adjusted for age, gender, bearing combination and
Aims. The goals of this study were to define the risk factors, characteristics,
and chronology of fractures in 5417 revision total hip arthroplasties
(THAs). . Patients and Methods. From our hospital’s prospectively collected database we identified
all patients who had undergone a revision THA between 1969 and 2011
which involved the femoral stem. The patients’ medical records and
radiographs were examined and the relevant data extracted. Post-operative
periprosthetic fractures were classified using the Vancouver system.
A total of 5417 revision THAs were identified. Results. There were 668 intra-operative fractures, giving an incidence
of 12%. Fractures were three times more common with uncemented stems
(19%) than with cemented stems (6%) (p <
0.001). The incidence
of intra-operative femoral fracture varied by uncemented stem type:
fully-coated (20%); proximally-coated (19%); modular fluted tapered
(16%) (p <
0.05). Most fractures occurred during the insertion
of the femoral component (35%). One-third involved the diaphysis
and 26% were of the calcar: 69% were undisplaced. There were 281 post-operative fractures of the femur (20-year
probability = 11%). There was no difference in risk for cemented
and uncemented stems. Post-operative fractures were more common
in men <
70 years (p = 0.02). Periprosthetic fractures occurred
earlier after uncemented revision of the femoral component, but
later after a cemented revision. The most common fracture type was
a Vancouver B. 1. (31%). Of all post-operative fractures,
24% underwent open reduction and internal fixation and 15% revision
arthroplasty. Conclusion. In revision THA, intra-operative fractures occurred three times
more often with an uncemented stem. Many were undisplaced diaphyseal
fractures treated with cerclage fixation. . While the risk of post-operative fracture is similar between
uncemented and cemented components, they occur at notably different
times depending on the type of
Introduction. The Vancouver Classification System presents a systematic approach to classification of periprosthetic fractures of the proximal femur (PFPFs) that has been validated in previous studies. However, with the introduction of tapered fluted stems and cable plates since the introduction of the Vancouver System, the connection between fracture class and the preferred method of treatment is often unclear. The present study was undertaken to identify fracture patterns surrounding contemporary femoral stems and the relationship between the current method of treatment and the Vancouver Class of the periprosthetic fracture. Methods. Three experienced joint surgeons collected plain radiographs (AP and lateral) and CT/MR scans (n=40) from 72 cases of Vancouver A or B periprosthetic fractures performed over the period 2016–2018. We identified the mode of primary
Background. Antibiotic loaded bone cement (ALBC) is commonly used in cemented total hip arthroplasty (THA) in an attempt to reduce the risk of prosthetic joint infection (PJI). However, its role versus plain cement remains controversial due to the potential risk of developing resistant organisms and potential excess costs incurred from its usage. We investigated the relationship of ALBC and plain cement in affecting outcome of revision surgery after primary THA. Methodology. We conducted a retrospective study of data collected from National Joint Registry for England and Wales, Northern Ireland and the Isle of Man between 1. st. September 2005 until 31. st. August 2017. A logistic regression analysis model was used to investigate the association between ALBC versus plain cement and the odds ratio (OR) for revision, adjusting for age, ASA grade, bearing surfaces, head size and cup and
When performing revision total hip arthroplasty using diaphyseal-engaging titanium tapered stems (TTS), the recommended 3 to 4 cm of stem-cortical diaphyseal contact may not be available. In challenging cases such as these with only 2 cm of contact, can sufficient axial stability be achieved and what is the benefit of a prophylactic cable? This study sought to determine, first, whether a prophylactic cable allows for sufficient axial stability when the contact length is 2 cm, and second, if differing TTS taper angles (2° vs 3.5°) impact these results. A biomechanical matched-pair cadaveric study was designed using six matched pairs of human fresh cadaveric femora prepared so that 2 cm of diaphyseal bone engaged with 2° (right femora) or 3.5° (left femora) TTS. Before impaction, three matched pairs received a single 100 lb-tensioned prophylactic beaded cable; the remaining three matched pairs received no cable adjuncts. Specimens underwent stepwise axial loading to 2600 N or until failure, defined as stem subsidence > 5 mm.Aims
Methods
Cementing in arthroplasty for hip fracture is associated with improved postoperative function, but may have an increased risk of early mortality compared to uncemented fixation. Quantifying this mortality risk is important in providing safe patient care. This study investigated the association between cement use in arthroplasty and mortality at 30 days and one year in patients aged 50 years and over with hip fracture. This retrospective cohort study used linked data from the Australian Hip Fracture Registry and the National Death Index. Descriptive analysis and Kaplan-Meier survival curves tested the unadjusted association of mortality between cemented and uncemented procedures. Multilevel logistic regression, adjusted for covariates, tested the association between cement use and 30-day mortality following arthroplasty. Given the known institutional variation in preference for cemented fixation, an instrumental variable analysis was also performed to minimize the effect of unknown confounders. Adjusted Cox modelling analyzed the association between cement use and mortality at 30 days and one year following surgery.Aims
Methods