Long bone fractures are a commonly presented paediatric injury. Whilst the possibility of either accidental or non-accidental aetiology ensures significant forensic relevance, there remain few clinical approaches that assist with this differential diagnosis. The aim of this current study was to generate a reproducible model of
We have analysed the initial displacement and the retention of position after reduction of 192
Elastic stable intramedullary nailing (ESIN)
is generally acknowledged to be the treatment of choice for displaced diaphyseal
femoral fractures in children over the age of three years, although
complication rates of up to 50% are described. Pre-bending the nails
is recommended, but there are no published data to support this.
Using synthetic bones and a standardised simulated fracture, we
performed biomechanical testing to determine the influence on the
stability of the fracture of pre-bending the nails before implantation.
Standard ESIN was performed on 24 synthetic femoral models with
a
Aims. The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. Methods. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals. Results. The spiral and oblique fracture patterns withstood simulated weight-bearing with minimal displacement. The multifragmented model had early implant failure with breaking of the distal locking screws. The
Aims. This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results. A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion. The commonest fracture types are B1 and
Cemented total hip replacement (THR) provides excellent outcomes and is cost-effective. Polished taper-slip (PTS) stems demonstrate successful results and have overtaken traditional composite-beam (CB) stems. Recent reports indicate they are associated with a higher risk of postoperative periprosthetic femoral fracture (PFF) compared to CB stems. This study evaluates risk factors influencing fracture characteristics around PTS and CB cemented stems. Data were collected for 584 PFF patients admitted to eight UK centres from 25/05/2006-01/03/2020. Radiographs were assessed for Unified Classification System (UCS) grade and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (PTS versus CB). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (OR) with 95% confidence intervals (CI). Median (IQR) age was 79.1 (72.0–86.0) years, 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The commonest AO/OTA type was spiral (352, 60.3%). Metaphyseal-split fractures occurred only with PTS stems with an incidence of 10.1%. Male gender was associated with a five-fold reduction in odds of a type C fracture (OR 0.22, 95% CI 0.12 to 0.41, p<0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51, 95% CI 3.72 to 24.34, p <0.001) and wedge fracture (OR 3.72, 95% CI 1.16 to 11.95, p <0.05) compared to PTS stems. This is the largest study investigating PFF characteristics around cemented stems. The commonest fracture types are B1 and
There is an increasing acceptance that the clinical outcomes following posterior malleolar fractures are less than satisfactory. Current ankle classification systems do not account for differences in fracture patterns or injury mechanisms, and as such, the clinical outcomes of these fractures are difficult to interpret. The aim of this study was to analyse our posterior malleolar fractures to better understand the anatomy of the fracture. In a series of 42 consecutive posterior malleolar, who all underwent CT imaging, we have described anatomically different fracture patterns dictated by the direction of the force and dependent on talus loading. We found 3 separate categories. Type 1 – a rotational injury in an unloaded talus resulted in an extraarticular posterior avulsion of the posterior ligaments. This occurred in 10 patients and was most commonly associated with either a high fibular
Purpose: Radial paralysis is a major complication of humeral shaft fractures. In most cases, the paralysis is regressive but in certain patients surgical repair is required to achieve full neurological recovery. We reviewed retrospectively our patients to determine the causes of non-recovery and evaluate the efficacy of different treatments. Material and methods: Thirty patients were operated between 1990 and 1997 for radial nerve paralysis that was observed immediately after trauma or developed secondarily. Mean follow-up after surgery was 6.3 years. There were 22 men and 8 women, 16 right side and 14 left side. Mean delay from injury to surgery was four months (0–730 days). Elements that could be involved in radial paralysis were noted: type of fracture, level of the fracture, treatment, approach, material used. There were ten cases with non-union. Neurological recovery at three years was assessed with muscle tests and with the Alnot criteria. An electrical recording was also made in certain patients. Surgery involved neurolysis in 23 cases, nerve grafts in five and tendon transfers in two. Results: Outcome was very good and good in 22 patients, good in one and could not be evaluated in one (tendon transfer). There were three failures (two neurolysis and one graft) and two patients were lost to follow-up. After neurolysis, mean delay to recovery was seven months; it was 15 months after nerve grafts. Recovery always occurred proximally to distally. Discussion: Radial paralysis after femoral shaft fracture regresses spontaneously in 76% to 89% of the cases, depending on the series. There is a predominance in the 20 to 30 year age range. Several factors could be involved in radial paralysis (fracture of the distal third of the humerus,
The management of radial nerve palsy associated with fractures of the shaft of the humerus has been disputed for several decades. This study has systematically reviewed the published evidence and developed an algorithm to guide management. We searched web-based databases for studies published in the past 40 years and identified further pages through manual searches of the bibliography in papers identified electronically. Of 391 papers identified initially, encompassing a total of 1045 patients with radial nerve palsy, 35 papers met all our criteria for eligibility. Meticulous extraction of the data was carried out according to a preset protocol. The overall prevalence of radial nerve palsy after fracture of the shaft of the humerus in 21 papers was 11.8% (532 palsies in 4517 fractures). Fractures of the middle and middle-distal parts of the shaft had a significantly higher association with radial nerve palsy than those in other parts. Transverse and
Introduction: The incidence of Peri-prosthetic fractures is about 1% following Lower limb arthroplasty. The management of these fractures is difþcult,complex,challenging and controversial. Aim of Study: To study the results of Dal- Miles Plating system in Peri-prosthetic fractures. To þnd the difference, if any in the outcome of Transverse vs.
The April 2023 Wrist & Hand Roundup360 looks at: MRI-based classification for acute scaphoid injuries: the OxSMART; Deep learning for detection of scaphoid fractures?; Ulnar shortening osteotomy in adolescents; Cost-utility analysis of thumb carpometacarpal resection arthroplasty; Arthritis of the wrist following scaphoid fracture nonunion; Extensor hood injuries in elite boxers; Risk factors for reoperation after flexor tendon repair; Nonoperative versus operative treatment for displaced finger metacarpal shaft fractures.
Background. Sub-trochanteric fractures are challenging to treat due to various anatomical and biomechanical factors. High tensile forces contribute to the challenge of fracture reduction. Intramedullary nailing has become the treatment of choice. If anatomical reduction is not achieved, any mal-alignment will predispose to implant failure. Open reduction with cerclage wires can add to construct stability and improve the quality of reduction. There is no consensus or classification to guide surgeons on when to perform open reduction, which is often performed intra-operatively when closed reduction fails often with no planning. This can lead to intraoperative delays as theatre staff would not have prepared the correct equipment necessary for open reduction. Objectives. The purpose of this study was to assess outcomes of closed and open reduction of traumatic sub-trochanteric fractures treated with intramedullary nailing and to propose a new classification system to dictate management. Methods. After a review of current classification systems, a 3-tier classification was proposed (Type 1, 2 and 3). Type 1 indicated a transverse fracture, Type 2 was a
We have reviewed the results of treating 75 fractures of the proximal femoral shaft in the presence of a cemented femoral prosthesis. A simple radiographic classification into four types is proposed, and suggestions are made on the appropriate management of each. Comminuted fractures around the implant need early revision, whilst
1. Linear fractures of the shaft of the long bones are divided into four basic types: 1) transverse; 2) oblique transverse; 3) spiral; and 4) oblique. 2. The mode of production of these fractures is deduced on the grounds of simple mechanical theory: 1) transverse fractures are a result of angulation; 2) oblique transyerse are the result of angulation with axial loading; 3)
Fractures of the distal tibia metaphysis comprise a challenge for the orthopaedic trauma surgeon because of the poor blood irrigation they do not heal very easy leading sometimes to pseudarthrosis and many times arise problems with the skin. We compare the following techniques: LC-DCP and LCP plates, MIPO, External fixators (hybrids or simple one), intramedullary nailing with multiple screws at the distal end. 94 cases of distal tibia fractures from all AO types were treated during last 3 years (2005–2008) with the following techniques:. 16 ORIF with LC-DCP plates. 9 ORIF with LCP plates. 19 MIPO. 35 External fixators. 15 intramedullary nailing. The simple oblique or
Between 1999 and 2002 14 children with femoral shaft fractures were treated with closed, locked intramedullary nailing. There were 11 male and 3 female patients, aged 11–16 years (mean 14.4 years). All fractures were closed. There were 9 transverse, 1 pathologic, 1 bipolar, 1 malunited and 2
Aim. In the last years, many short hip stem variants were developed, almost always sharing the principle of metaphyseal and proximal diaphyseal anchorage. In this study, we analyzed the midterm results after implanting short cementless hip stem of ESKA. Methods. A total of 380 total hip replacements using the ESKA-short cementless stems were performed in a series of 340 patients between November 2002 till May 2008. The clinical and radiological evaluation of the patients was done in September 2008. The mean follow up was 37 months (3–54 months). Results. The mean age of the patients was 65 years (35–85 years). The indications varied between osteoarthritis (n=342), avascular necrosis (n=23) and aseptic loosening of stem (n=15). Good clinical and radiological outcome without complications was observed in 361 cases. However, complications were recorded in 19 cases. Aseptic loosening was noted in 4 cases and was treated with stem exchange. Deep infection occurred in 5 cases, 3 of which had direct exchange and 2 had two-stage delayed reconstruction. Dislocation was noted in 2 cases, which were revisions after aseptic loosening. 8 patients suffered intraoperative femur fissures, 7 of which healed completely after prolonged partial weight bearing postoperatively (n=4 without osteosynthesis, n=3 needed adjunctive cerclage around the proximal femur). Only 1
This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged less than 50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. We describe the survival, radiological, and functional outcomes of 33 patients (38 THAs) at a mean follow-up of 27 years (25 to 32) between 1988 and 2018.Aims
Methods