Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 28 - 28
17 Apr 2023
Jimenez-Cruz D Dubey M Board T Williams S
Full Access

Hip joint biomechanics can be altered by abnormal morphology of the acetabulum and/or femur. This may affect load distribution and contact stresses on the articular surfaces, hence, leading to damage and degradation of the tissue. Experimental hip joint simulators have been used to assess tribology of total hip replacements and recently methods further developed to assess the natural hip joint mechanics. The aim of this study was to evaluate articular surfaces of human cadaveric joints following prolonged experimental simulation under a standard gait cycle. Four cadaveric male right hips (mean age = 62 years) were dissected, the joint disarticulated and capsule removed. The acetabulum and femoral head were mounted in an anatomical hip simulator (Simulation Solutions, UK). A simplified twin peak gait cycle (peak load of 3kN) was applied. Hips were submerged in Ringers solution (0.04% sodium azide) and testing conducted at 1 Hertz for 32 hours (115,200 cycles). Soft tissue degradation was recorded using photogrammetry at intervals throughout testing. All four hips were successfully tested. Prior to simulation, two samples exhibited articular surface degradation and one had a minor scalpel cut and a small area of cartilage delamination. The pre-simulation damage got slightly worse as the simulation continued but no new areas of damage were detected upon inspection. The samples without surface degradation, showed no damage during testing and the labral sealing effect was more obvious in these samples. The fact that no new areas of damage were detected after long simulations, indicates that the loading conditions and positioning of the sample were appropriate, so the simulation can be used as a control to compare mechanical degradation of the natural hip when provoked abnormal conditions or labral tissue repairs are simulated


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 39 - 39
1 Mar 2021
Jimenez-Cruz D Masterson A Dubey M Board T Williams S
Full Access

Abstract. OBJECTIVES. Abnormal joint mechanics have been proposed as adversely affecting natural hip joint tribology, whereby increased stress on the articular cartilage from abnormal loading leads to joint degeneration. The aim of this project was to assess the damage caused by different loading conditions on the articular surfaces of the porcine hip joint in an experimental simulator. METHODS. Porcine hip joints were dissected and mounted in a single station hip simulator (SimSol, UK) and tested under loading scenarios (that corresponded to equivalent of different body mass index's’ (BMI) in humans), as follows:“Normal” (n=4), the loading cycle consisted of a simplified gait cycle based on a scaled version of a simplified twin-peak human gait cycle, the peak load was 900N (representative of a healthy BMI). Representative of an “Overweight” BMI (n=3), as the normal cycle with a peak load of 1,130N Representative of an “Obese” BMI (n=1), as the normal cycle with a peak load of 1,340N Tests were conducted at 1Hz for 14,400 cycles in Ringers solution; photogrammetry was used to characterise the appearance of the cartilage and labrum pre, during and post simulation. the appearance and location of damage was recorded. RESULTS. No significant damage was observed for samples tested under normal conditions. Following “overweight” condition testing, tears and detachment of the labrum were observed during testing in two (of three) samples. In addition to damaged observed in “overweight” tested samples the “obese” showed similar damage and also cartilage bruising and wear tracks on the articular surface of the acetabulum. DISCUSSION. The absence of damage in “normal” loading provides evidence that this is an appropriate methodology and loading regime for porcine hips. Increased damage with increasing loads demonstrates the potential to develop further this experimental simulation to assess adverse loading in natural hip joints. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 24 - 24
1 Dec 2022
Trisolino G Frizziero L Santi GM Alessandri G Liverani A Menozzi GC Depaoli A Martinelli D Di Gennaro GL Vivarelli L Dallari D
Full Access

Paediatric musculoskeletal (MSK) disorders often produce severe limb deformities, that may require surgical correction. This may be challenging, especially in case of multiplanar, multifocal and/or multilevel deformities. The increasing implementation of novel technologies, such as virtual surgical planning (VSP), computer aided surgical simulation (CASS) and 3D-printing is rapidly gaining traction for a range of surgical applications in paediatric orthopaedics, allowing for extreme personalization and accuracy of the correction, by also reducing operative times and complications. However, prompt availability and accessible costs of this technology remain a concern. Here, we report our experience using an in-hospital low-cost desk workstation for VSP and rapid prototyping in the field of paediatric orthopaedic surgery. From April 2018 to September 2022 20 children presenting with congenital or post-traumatic deformities of the limbs requiring corrective osteotomies were included in the study. A conversion procedure was applied to transform the CT scan into a 3D model. The surgery was planned using the 3D generated model. The simulation consisted of a virtual process of correction of the alignment, rotation, lengthening of the bones and choosing the level, shape and direction of the osteotomies. We also simulated and calculated the size and position of hardware and customized massive allografts that were shaped in clean room at the hospital bone bank. Sterilizable 3D models and PSI were printed in high-temperature poly-lactic acid (HTPLA), using a low-cost 3D-printer. Twenty-three operations in twenty patients were performed by using VSP and CASS. The sites of correction were: leg (9 cases) hip (5 cases) elbow/forearm (5 cases) foot (5 cases) The 3D printed sterilizable models were used in 21 cases while HTPLA-PSI were used in five cases. customized massive bone allografts were implanted in 4 cases. No complications related to the use of 3D printed models or cutting guides within the surgical field were observed. Post-operative good or excellent radiographic correction was achieved in 21 cases. In conclusion, the application of VSP, CASS and 3D-printing technology can improve the surgical correction of complex limb deformities in children, helping the surgeon to identify the correct landmarks for the osteotomy, to achieve the desired degree of correction, accurately modelling and positioning hardware and bone grafts when required. The implementation of in-hospital low-cost desk workstations for VSP, CASS and 3D-Printing is an effective and cost-advantageous solution for facilitating the use of these technologies in daily clinical and surgical practice


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 2 - 2
1 Jul 2014
Gao B Angibaud L
Full Access

Summary Statement. The constraint behavior of total knee arthroplasty (TKA) prosthesis usually has to be physically tested. This study presents a computer simulation model using finite element analysis (FEA) and demonstrates its effectiveness in predicting the femorotibial constraint behavior of TKA implants. Introduction. TKA prostheses are semi-constrained artificial joints. A well-functioning TKA prosthesis should be designed with a good balance between stability and mobility, meaning the femorotibial constraint of the artificial joint cannot be excessive or too lax. To assess the constraint behavior of a TKA prosthesis, physical testing is usually required, and an industrial test standard has been developed for this purpose. Benefiting from technological advancement, computer simulation has become increasingly useful in many industries, including medical device research and development. FEA has been extensively used in stress analysis and structural evaluation of various orthopaedic implants. This study presented an FEA-based simulation to evaluate the femorotibial constraint behavior of TKA prosthesis, and demonstrated the effectiveness of the method by validating it through physical testing. Methods. A Cruciate Retaining (CR) TKA prosthesis design (Optetrak Logic CR, size 3, Exactech, FL, USA) was used in this study. The prosthesis system consists of a femoral component, a tibial insert, and a tibial baseplate. CAD models of the implants assembled at 0° of flexion were used for the simulation. Finite element models were generated using 10-node tetrahedral elements, with all materials considered linear elastic. Boundary conditions were set up according to the ASTM F1223 standard. The tibial baseplate was fixed distally. A constant compressive force (710 N) was applied on the femoral component. Nonlinear Surface-Surface-Contact was defined at the femorotibial articulating surfaces as well as between the tibial insert and tibial baseplate. A coefficient of friction of 0.2 determined from the physical test was input into the simulation. The femoral component was driven under a displacement-controlled scheme to slide along the anterior-posterior (AP) direction on the tibial insert. At each time step, constraint force occurring at the articulating surface was derived from the reaction force at the distal fixation of the tibial baseplate. The force-displacement curve was plotted by combining the results of all time steps to characterize the constraint behavior of the prosthesis. A nonlinear FEA solver (NX Nastran SOL601, Siemens, TX, USA) was used to solve the simulation. In addition, five samples of the prostheses were physically tested per ASTM F1223. Simulation results were compared to the physical testing. Results. The simulation successfully captured the movement of contact location and pressure along the movement of the femoral component. The force-displacement curve predicted by the simulation exhibited a very close hysteresis loop profile as the results of physical testing. Using the curve slope from 0 to 5 mm to characterise the constraint in the most relevant displacement range, the simulation predicted 45.7 N/mm anteriorly and 36.4 N/mm posteriorly, which are less than 10% different from the physical testing results (46.4 N/mm anteriorly and 39.6 N/mm posteriorly). Discussion/Conclusion. This study demonstrated that the simulation was able to closely predict the femorotibial constraint behavior of the TKA prosthesis under ASTM F1223 testing. The simulation results resembled the physical test results not only in the general profile of the curve but also in the magnitude of slope values. The increased difference at the far anterior region could be related to the fact that no material nonlinearity was considered in the current simulation, a factor that could be improved in future studies. A validated simulation method could be very useful in TKA prosthesis design. Since no physical prototypes are required, design evaluation and optimization can be achieved in a much easier and faster manner


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 47 - 47
1 Jan 2019
Abdelgaied A Fisher J Jennings LM
Full Access

Experimental simulation is the gold standard wear testing method for total knee replacements (TKR), with reliable replication of physiological kinematic conditions. When combined with a computational model, such a framework is able to offer deeper insight into the biomechanical and wear mechanisms. The current study developed and validated a comprehensive combined experimental and computational framework for pre-clinical biomechanics and wear simulation of TKR. A six-station electro-mechanical knee simulator (SimSol, UK), capable of replicating highly demanding conditions with improved input kinematic following, was used to determine the wear of Sigma fixed bearing curved TKRs (DePuy, UK) under three different activities; standard-walking, deep-squat, and stairs-ascending. The computational model was used to predict the wear under these 3 conditions. The wear calculation was based on a modification of Archard's law which accounted for the effects of contact stress, contact area, sliding distance, and cross-shear on wear. The output wear predictions from the computational model were independently validated against the experimental wear rates. The volumetric wear rates determined experimentally under standard-walking, deep-squat, and stairs-ascending conditions were 5.8±1.4, 3.5±0.8 and 7.1±2.0 [mm3/mc] respectively (mean ± 95% CI, n=6). The corresponding predicted wear rates were 4.5, 3.7, and 5.6 [mm3/mc]. The coefficient of determination for the wear prediction of the framework was 0.94. The wear predictions from the computational model showed good agreement with the experimental wear rates. The model did not fully predict the changes found experimentally, indicating other factors in the experimental simulation not yet incorporated in the framework, such as plastic deformation, may play an additional role experimentally in high demand activities. This also emphasises the importance of the independent experimental validation of computational models. The combined experimental and computational framework offered deeper insight into the contact mechanics and wear from three different standard and highly demanding daily activities. Future work will adopt the developed framework to predict the effects of patients and surgical factors on the mechanics and wear of TKR


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 32 - 32
1 Dec 2021
Edwards T Khan S Patel A Gupta S Soussi D Liddle A Cobb J Logishetty K
Full Access

Abstract. Objectives. Evidence supporting the use of immersive virtual reality (iVR) training in orthopaedic procedures is rapidly growing. However, the impact of the timing of delivery of this training is yet to be tested. This study investigated whether spaced iVR training is more effective than massed iVR training for novices learning hip arthroplasty. Methods. 24 medical students with no hip arthroplasty experience were randomised to learning total hip arthroplasty using the same iVR simulation training either once-weekly or once-daily for four sessions. Participants underwent a baseline physical world assessment to orientate an acetabular component on a saw bone pelvis, and a baseline knowledge test. In iVR, we recorded procedural errors, time, numbers of prompts required and path lengths of the hands and head across 4 sessions. To assess skill retention, the iVR and baseline physical world assessments were repeated at one-week and one-month. Results. Baseline characteristics between the groups were comparable (p > 0.05). The daily group demonstrated faster skills acquisition, reducing the mean number of procedural errors from 76.8±37.5 (S1) to 11.1±10.1 (S4), compared to the weekly group improvement from 71.1±19.1 (S1) to 17.2±10.6 (S4), p < 0.001. The weekly group error count plateaued remaining at 16±6.7 at 1-week and 17.5±8.5 at one-month, the daily group however, showed poor retention with error counts rising to 17.8±10.5 at 1 week and becoming higher than the weekly group at one-month to (23.2±13.0 vs 17.5±10.5). A similar effect was noted for procedural time and the number of assistive prompts. In the real-world assessment, both groups significantly improved the accuracy of their acetabular component positioning, these improvements were equally maintained. Conclusions. Daily iVR training facilitates faster skills acquisition, however weekly practice has superior skills retention. Skills learnt using both regimes demonstrate sustained transfer to the real-world


Objectives. Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results. Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion. This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 51 - 51
2 Jan 2024
Grad S
Full Access

Mechanical loading is important to maintain the homeostasis of the intervertebral disc (IVD) under physiological conditions but can also accelerate cell death and tissue breakdown in a degenerative state. Bioreactor loaded whole organ cultures are instrumental for investigating the effects of the mechanical environment on the IVD integrity and for preclinical testing of new therapies under simulated physiological conditions. Thereby the loading parameters that determine the beneficial or detrimental reactions largely depend on the IVD model and its preparation. Within this symposium we are discussing the use of bovine caudal IVD culture models to reproduce tissue inflammation or matrix degradation with or without bioreactor controlled mechanical loading. Furthermore, the outcome parameters that define the degenerative state of the whole IVD model will be outlined. Besides the disc height, matrix integrity, cell viability and phenotype expression, the tissue secretome can provide indications about potential interactions of the IVD with other cell types such as neurons. Finally, a novel multiaxial bioreactor setup capable of mimicking the six degrees-of-freedom loading environment of IVDs will be introduced that further advances the relevance of preclinical ex-vivo testing.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 48 - 48
1 Apr 2018
Reyna ALP Fritz B Schwiesau J Summer B Thomas P Grupp TM
Full Access

Total knee arthroplasty is a well established treatment for degenerative joint disease with good clinical results. However, complications may occur due to a biological response to polyethylene wear particles, leading to osteolysis and aseptic loosening, as well as local and systemic hypersensitivity reactions triggered by metal ions and particles such as chromium, cobalt and molybdenum. Moreover, there is an increasing demand on the performance of these implants, as this treatment is also performed in heavier, younger and middle-aged adults who have a significant physical activity and higher life expectancy. The purpose of the following study was to compare the wear characteristics and performance of a zirconium nitride (ZrN) coated knee implant, designed for patients with metal ion hypersensitivity, against the clinically established cobalt-chromium (CoCr) version under a high demanding activities wear simulation. Medium size AS Columbus® DD (Aesculap AG, Tuttlingen, Germany) femoral and tibial components with a ZrN surface were tested in comparison with the cobalt-chromium version Columbus® DD. For both groups, ultra-high-molecular weight polyethylene (UHMWPE) gliding surfaces (size T3, high 10 mm) were used. Wear simulation was performed on a load controlled 4 station knee wear simulator (EndoLab GmbH, Thansau, Germany) capable of reproducing loads and movement of daily activities measured in vivo (Bergmann et al, 2014) on 8 patients and normalized to a patient weight of 100 kg (Schwiesau et al, 2014). The load profiles were applied for 5 million cycles in a combination of 40% stairs up, 40% stairs down, 10% level walking, 8% chair raising and 2% deep squatting. Test serum was changed every 0.5 million cycles and all the components were cleaned and analyzed according to ISO 14243-2:2009(E). The gliding surfaces were evaluated for gravimetric wear and wear patterns, femur components analyzed for scratches and the test medium analyzed for metal ion concentration (cobalt, chromium, molybdenum and zirconium) using ICP-MS according to ISO 17294-2. The present study showed a wear rate reduction for the ZrN group (1.01 ± 0.29 mg/million) in comparison with the CoCr group (2.40 ± 1.18 mg/million cycles). The articulation surface of the ZrN coated femurs remained polished after the testing period, whereas the uncoated femurs showed wear scratches. Furthermore, the metal ion release from the ZrN coated implants was reduced orders of magnitude in comparison with the CoCr implants through the entire test. These results demonstrate the efficiency of ZrN coated knee implants to reduce wear as well as to prevent metal ion release in the knee joint


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 48 - 48
1 Apr 2018
Kebbach M Grawe R Geier A Winter E Kluess D Woernle C Bader R
Full Access

Introduction. Despite decades of clinical research in artificial joints and underlying failure mechanisms, systematical and reproducible identification of reasons for complications in total knee replacements (TKR) remains difficult. Due to the complex dynamic interaction of implant system and biological situs, malfunction eventually leading to failure is multifactorial and remains not fully understood. The aim of present study was to evaluate different TKR designs and positions with regard to joint kinematics and stability under dynamic conditions by using a robot-based hardware-in-the-loop (HiL) setup. Material & methods. An industrial 6-axis robot with 6-axis force-torque sensor mounted into its end-effector moved and loaded real, commercially available TKR (bicondylar, cruciate-retaining) that were in virtual interaction with a subject-specific computational multibody model representing the anatomical situs of the knee joint while performing passive seated deep knee flexion. The subject-specific musculoskeletal multibody model (MMB) included rigid bones of the lower right extremity. Bone and cartilage geometries were reconstructed from MRT/ CT data sets preserving anatomical landmarks and allowing for the calculation of inertial properties. M. quadriceps femoris was modeled as single passive tensile force elements. Knee ligaments were modelled as elastic spring elements with a nonlinear force-displacement characteristic. Providing the flexion angle, the robot moved and loaded the mounted femoral implant component with respect to the tibial component while being in continuous interaction with the MMB. Several influencing parameters like implant position (internal/external rotation, varus/valgus alignment) and design (fixed vs. mobile bearing, tibia-insert height) as well as ligament insufficiency and joint loading on joint kinematics and stability was systematically analysed. Results. Improper implant positioning caused joint instability, which was demonstrated in higher magnitudes of the relative kinematics. Negative effects by incorrect implant positioning could be partially compensated by a mobile bearing design. However, this was accompanied with an increase in tibiofemoral contact forces. High correlation of tibia-insert height on ligament and contact force was found. After releasing ligament structures, lower tibiofemoral contact forces and joint opening during deep knee flexion were observed. Conclusion. By means of HiL simulation different clinical and technical parameters of TKR were evaluated in a systematical and reproducible fashion under physiological-like boundary conditions with regard to joint kinematics and stability. The proposed HiL test setup combining robot-based testing with MMBs can contribute to deeper understanding of knee joint function and improvement of total knee implant systems. Acknowledgement. The authors would like to thank the Deutsche Forschungsgemeinschaft (grant numbers: WO WO 452/8-1, BA 3347/3-1 and KL 2327/4-1) for supporting the project


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 23 - 23
1 Nov 2018
Sano H Komatsuda T Inawashiro T Sasaki D Noguchi M Irie T Abe H Abrassart S
Full Access

Latarjet procedure (transfer of coracoid process to the anterior glenoid rim) has been widely used for severe anterior shoulder instability. The purpose of the present study was to investigate the intraarticular stress distribution after this procedure to clarify the pathomechanism of its postoperative complications. CT-DICOM data of the contralateral healthy shoulder in 10 patients with unilateral anterior shoulder instability (9 males and 1 female, age: 17–49) was used for the present study. Three-dimensional finite element models of the glenohumeral joint was developed using software, Mechanical Finder (RCCM, Japan). In each shoulder, a 25% bony defect was created in the anterior glenoid cavity, where coracoid process was transferred using two half-threaded screws. The arm position was determined as 0-degree and 90-degree abduction. While medial margin of the scapula was completely constrained, a standard compressive load (50 N) toward the centre of the glenoid was applied to the lateral wall of the greater tuberosity. A tensile load (20N) was also applied to the tip of coracoid process along the direction of conjoint tendon. Then, elastic analysis was performed, and the distribution pattern of Drucker-Prager equivalent stress was investigated in each model. The proximal half of the coracoid represented significantly lower equivalent stress than the distal half (p < 0.05). In particular, the lowest mean equivalent stress was seen in its proximal-medial-superficial part. On the other hand, a high stress concentration newly appeared in the antero-inferior aspect of the humeral head exactly on the site of coracoid bone graft. We assumed that the reduction of mean equivalent stress in the proximal half of the coracoid was caused by the stress shielding, which may constitute one of the pathogenetic factors of its osteolysis. A high stress concentration in the humeral head may eventually lead shoulder joint to osteoarthritis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 46 - 46
1 Aug 2012
Taylor S Tsiridis E Ingham E Jin Z Fisher J Williams S
Full Access

Tribology and wear of articular cartilage is associated with the mechanical properties, which are governed by the extracellular matrix (ECM). The ECM adapts to resist the loads and motions applied to the tissue. Most investigations take cartilage samples from quadrupeds, where the loading and motions are different to human. However, very few studies have investigated the differences between human and animal femoral head geometry and the mechanical properties of cartilage.

This study assessed the differences between human, porcine, ovine and bovine cartilage from the femoral head; in terms of anatomical geometry, thickness, equilibrium elastic modulus and permeability.

Diameter of porcine (3-6 months old), bovine (18-24 months old), ovine (4 years old) and human femoral heads were measured (n=6). Plugs taken out of the superior region of each femoral head and creep indentation was performed. The human femoral heads were obtained from surgery due to femoral neck fracture. Cartilage thickness was measured by monitoring the resistive force change as a needle traversed the cartilage and bone at a constant feed rate using a mechanical testing machine. The percentage deformation over time was determined by dividing deformation by thickness. A biphasic finite element model was used to obtain the intrinsic material properties of each plug. Data is presented as the mean ± 95% confidence limits. One-way ANOVA was used to test for significant differences (p < or = 0.05).

Significant differences in average femoral head diameter were observed between all animals, where bovine showed the largest femoral head. Human cartilage was found to be significantly thicker than cartilage from all quadrupedal hips. Human cartilage had a significantly larger equilibrium elastic modulus compared to porcine and bovine cartilage. Porcine articular cartilage was measured to be the most permeable which was significantly larger than all the other species. No significant difference in permeability was observed between human and the other two animals: bovine and ovine (Table 1).

The current study has shown that articular cartilage mechanical properties, thickness and geometry of the femoral heads differ significantly between different species. Therefore, it is necessary to consider these variations when choosing animal tissue to represent human.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 46 - 46
1 Aug 2013
Gillespie J Gislason M Ugbolue U Hems T
Full Access

Wrist arthrodesis is a common surgical procedure that provides a high level of functional outcome and pain relief among patients.[1] Upon partial arthrodesis, the wrist experiences changes in load transmission that are influenced by the type of arthrodesis performed. Measuring the load through the wrist joint is difficult, however, combined with computational models [2], it is possible to obtain data regarding the load mechanics of the wrist joint. Although successful fusion rates among patients have been reported, it remains unclear what the biomechanical consequences are.

The aim of the study is to quantify pre and post operative load transmission through a cadaveric wrist which has undergone simulated arthrodesis of the radiolunate(RL) joint. An embalmed human wrist was dissected dorsally exposing distal radius, radiocarpal and carpometacarpal joints, and dorsal ligaments. The radioscaphoid(RS) ligament was sacrificed to accommodate insertion of a PPSEN-09375 force sensitive resistor (FSR) into the RS joint. The FSR was calibrated prior to measuring the contact force on the RS joint.

The wrist was aligned in the neutral position in cardboard piping, and secured proximally and distally with Dental Plaster (OthoBock Healthcare Plc, Surrey, UK). The midsection of piping was windowed to permit placement of the FSR in the RS joint, and fixation of the RL joint using 2 Kirschner wires. The window was completed circumferentially and the specimen was placed in the Instron where a graduated axial compression was applied at 20 N/min.

The results showed that when the radiolunate joint is fused, and a total axial load of 100N is applied, the load transmitted through the RS joint was approx 65N. i.e. 65% of the force. This is greater than the 56% measured experimentally by Blevens et al (1989) in an unfused specimen[3]. We plan to repeat our measurements and compare to an untreated cadaveric wrist.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 1 - 1
11 Apr 2023
Mischler D Knecht M Varga P
Full Access

Surgical education of fracture fixation biomechanics relies mainly on simplified illustrations to distill the essence of the underlying principles. These mostly consist of textbook drawings or hands-on exercises during courses, both with unique advantages such as broad availability and haptics, respectively. Computer simulations are suited to bridge these two approaches; however, the validity of such simulations must be guaranteed to teach the correct aspects. Therefore, the aim of this study was to validate finite element (FE) simulations of bone-plate constructs to be used in surgical education in terms of fracture gap movement and implant surface strain. The validation procedure was conducted in a systematic and hierarchical manner with increasing complexity. First, the material properties of the isolated implant components were determined via four-point bending of the plate and three-point bending of the screw. Second, stiffness of the screw-plate interface was evaluated by means of cantilever bending to determine the properties of the locking mechanism. Third, implant surface strain and fracture gap motion were measured by testing various configurations of entire fixation constructs on artificial bone (Canevasit) in axial compression. The determined properties of the materials and interfaces assessed in these experiments were then implemented into FE models of entire fixation constructs with different fracture width and screw configurations. The FE-predicted implant surface strains and fracture gap motions were compared with the experimental results. The simulated results of the different construct configurations correlated strongly with the experimentally measured fracture gap motions (R. 2. >0.99) and plate surface strains (R. 2. >0.95). In a systematic approach, FE model validation was achieved successfully in terms of fracture gap motion and implant deformation, confirming trustworthiness for surgical education. These validated models are used in a novel online education tool OSapp (. https://osapp.ch/. ) to illustrate and explain the biomechanical principles of fracture fixations in an interactive manner


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 80 - 80
2 Jan 2024
Mischler D Windolf M Gueorguiev B Varga P
Full Access

Osteosynthesis aims to maintain fracture reduction until bone healing occurs, which is not achieved in case of mechanical fixation failure. One form of failure is plastic plate bending due to overloading, occurring in up to 17% of midshaft fracture cases and often necessitating reoperation. This study aimed to replicate in-vivo conditions in a cadaveric experiment and to validate a finite element (FE) simulation to predict plastic plate bending. Six cadaveric bones were used to replicate an established ovine tibial osteotomy model with locking plates in-vitro with two implant materials (titanium, steel) and three fracture gap sizes (30, 60, 80 mm). The constructs were tested monotonically until plastic plate deformation under axial compression. Specimen-specific FE models were created from CT images. Implant material properties were determined using uniaxial tensile testing of dog bone shaped samples. The experimental tests were replicated in the simulations. Stiffness, yield, and maximum loads were compared between the experiment and FE models. Implant material properties (Young's modulus and yield stress) for steel and titanium were 184 GPa and 875 MPa, and 105 GPa and 761 MPa, respectively. Yield and maximum loads of constructs ranged between 469–491 N and 652–683 N, and 759–995 N and 1252–1600 N for steel and titanium fixations, respectively. FE models accurately and quantitatively correctly predicted experimental results for stiffness (R2=0.96), yield (R2=0.97), and ultimate load (R2=0.97). FE simulations accurately predicted plastic plate bending in osteosynthesis constructs. Construct behavior was predominantly driven by the implant itself, highlighting the importance of modelling correct material properties of metal. The validated FE models could predict subject-specific load bearing capacity of osteosyntheses in vivo in preclinical or clinical studies. Acknowledgements: This study was supported by the AO Foundation via the AOTRAUMA Network (Grant No.: AR2021_03)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 27 - 27
11 Apr 2023
Puente Reyna A Schwiesau J Altermann B Grupp T
Full Access

The purpose of the study was to compare the mechanical properties, oxidation and wear resistance of a vitamin E blended and moderately crosslinked polyethylene for total knee arthroplasty (MXE) in comparison with clinically established polyethylene materials. The following polyethylene materials were tested: CPE (30 kGy e-beam sterilized), XLPE (75 kGy gamma crosslinked @ 100°C), ViXLPE (0.1 % vitamin E blended, 80 kGy e-beam crosslinked @ 100°C), and MXE (0.1 % vitamin E blended polyethylene, 30 kGy gamma sterilized). For the different tests, the polyethylene materials were either unaged or artificially aged for two or six weeks according to ASTM F2003-02. The oxidation index was measured based on ASTM F2102 at a 1 mm depth. Small punch testing was performed based on ASTM F2977. Mechanical properties were measured on unaged materials according to ASTM D638. Wear simulation was performed on a load controlled 3 + 1 station knee wear simulator (EndoLab GmbH, Thansau, Germany) capable of reproducing loads and movement of highly demanding activities (HDA) as well as ISO 14243-1 load profiles. The load profiles were applied for 5 million cycles (mc) or delamination of the polyethylene components. Medium size AS e.motion. ®. PS Pro (Aesculap AG, Tuttlingen, Germany) femoral and tibial components with a ZrN-multilayer surface, as well as Columbus. ®. CR cobalt-chrome alloy femoral and tibial components were tested. Particle analysis was performed on the serum samples of the ISO 14243-1 wear simulations based on ISO 17853:2011 and ASTM F1877. The analysis of the mechanical properties show that moderately crosslinked polyethylene (MXE) might be a superior material for total knee arthroplasty applications [Schwiesau et al. 2021]. The addition of vitamin E in a moderately crosslinked polyethylene prevented its oxidation, kept its mechanical characteristics, and maintained a low wear, even under a HDA knee wear simulation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 138 - 138
2 Jan 2024
Muñoz-Moya E Ruiz C Piella G Noailly J
Full Access

This study investigates the relationships between Intervertebral Disc (IVD) morphology and biomechanics using patient-specific (PS) finite element (FE) models and poromechanical simulations. 169 3D lumbar IVD shapes from the European project MySpine (FP7-269909), spanning healthy to Pfirrmann grade 4 degeneration, were obtained from MRIs. A Bayesian Coherent Point Drift algorithm aligned meshes to a previously validated structural FE mesh of the IVD. After mesh quality analyses and Hausdorff distance measurements, mechanical simulations were performed: 8 and 16 hours of sleep and daytime, respectively, applying 0.11 and 0.54 MPa of pressure on the upper cartilage endplate (CEP). Simulation results were extracted from the anterior (ATZ) and posterior regions (PTZ) and the center of the nucleus pulposus (CNP). Data mining was performed using Linear Regression, Support Vector Machine, and eXtreme Gradient Boosting techniques. Mechanical variables of interest in DD, such as pore fluid velocity (FLVEL), water content, and swelling pressure, were examined. The morphological variables of the simulated discs were used as input features. Local morphological variables significantly impacted the local mechanical response. The local disc heights, respectively in the mid (mh), anterior (ah), and posterior (ph) regions, were key factors in general. Additionally, fluid transport, reflected by FLVEL, was greatly influenced (r2 0.69) by the shape of the upper and lower cartilage endplates (CEPs). This study suggests that disc morphology affects Mechanical variables of interest in DD. Attention should be paid to the antero-posterior distribution and local effects of disc heights. Surprisingly, the CEP morphology remotely affected the fluid transport in NP volumes around mid-height, and mechanobiological implications shall be explored. In conclusion, patient-specific IVD modeling has strong potential to unravel important correlations between IVD phenotypes and local tissue regulation. Acknowledgments: European Commission: Disc4All-MSCA-2020-ITN-ETN GA: 955735; O-Health-ERC-CoG-2021-101044828


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 130 - 130
1 Nov 2021
Giorgino R Luca A Ruberto E Besozzi G Banfi G Peretti G
Full Access

Introduction and Objective. Over the past few years, a reorganization of the educational pathways has been promoted with the purpose of optimizing the acquisition of competences and their assessment, so as to reduce the risks to both health care professionals and end users. Virtual reality (VR) has been repeatedly tested, initially as a positive reinforcement for more traditional educational pathways and, more recently, as their potential substitute. The aim of this study was to demonstrate the potentiality of VR simulation training in spine surgery. Materials and Methods. The VR simulator reproduced the lateral lumbar access to the spine. The simulation included a tutorial, the preoperative settings, and the surgical session with different levels of procedural complexity. A total of 10 users were recruited for this study: 3 senior surgeons (group A) and 7 orthopedic residents or junior orthopedic surgeons (group B). Each user completed the simulation twice. Results. The user's age or previous experience with VR technology did not show any relevance. On average, the entire simulation was completed in 24 minutes and 36 seconds. Group B showed an improvement between the 2 attempts in both sessions, the preoperative settings and the surgical simulation. The number of major errors dropped from an average of 5.2 to 1.8 and from an average of 4 (1–6) to 1.4, respectively. The simulation was never interrupted because of technical bugs or adverse effects related to the technology. Conclusions. VR-based training pathways might promote a high standard of care. Our preliminary experience suggests an effective implementation of the traditional coaching process


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 44 - 44
17 Nov 2023
Radukic B Phillips A
Full Access

Abstract. 1.0 Objectives. Predictive structural models resulting in a trabecular bone topology closely resembling real bone would be a step toward 3D printing of sympathetic prosthetics. This study modifies an established trabecular bone structural adaptation approach, with the objective of achieving an improved adapted topology, specifically connectivity, compared to CT imaging studies; whilst retaining continuum level mechanical properties consistent with those reported in experimental studies. Strain driven structural adaptation models successfully identify trabecular trajectories, although tend to overpredict connectivity and skew trabecular radii distribution towards the smallest radius included in the adaptation. Radius adaptation of each trabecula is driven by a mechanostat approach with a target strain (1250 µɛ) below which radius is decreased (resorption), and above which radius is increased (apposition). Simulations include a lazy zone, in which neither resorption nor apposition takes place (1000 to 1500 µɛ); and a dead zone (<250 µɛ) in which complete resorption of trabeculae with the smallest included radius takes place. This study assesses the impact of increasing the dead zone threshold from <250 µɛ to <1000 µɛ, the lower limit of the lazy zone. 2.0 Methods. In-silico structural models with an initial connectivity (number of trabeculae connecting at each joint) of 14 were generated using a nearest neighbour approach applied to a random cloud of points. Trabeculae were modelled using circular beams whose radii were adapted in response to normal strains caused by the axial force and bending moments due to a vertical pressure of 1 MPa applied to the top of the lattice, with the bottom of the lattice fixed in the vertical direction. Lattices in which nodes are either able (rigid jointed) or unable (pin jointed) to transmit bending moments were considered. Five virtual samples of each lattice type were used, and each simulation repeated twice: with a dead zone of either <250 µɛ or <1000 µɛ. 3.0 Results. In pin jointed lattices the increase in dead zone threshold resulted in reduction of predicted Young's Modulus from 580 MPa (95% CI [577 MPa, 583 MPa]) to 408 MPa (95% CI [397 MPa, 419 MPa]) whilst in rigid jointed lattices it increased form 839MPa (95% CI [832 MPa, 846 MPa]) to 933 MPa (95% CI [931 MPa, 936 MPa]). Mean connectivity decreased from 10.2 to 5.8 in pin jointed simulations and from 9.6 to 3.8 in fixed joined simulations. Topological studies of trabecular bone CT images report a mean connectivity of around 3.4. Pin jointed lattice mean radius increased from 33mm to 45mm, and rigid jointed lattice mean radius increased from 33mm to 64mm. Prevalence of smallest included radius beams decreased in both. 4.0 Conclusion. Improved in-silico representations of trabecular bone can be achieved in structural adaptions by increasing the dead zone threshold and adopting a bending dominated (rigid jointed) lattice structure. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 59 - 59
4 Apr 2023
MacLeod A Roberts S Mandalia V Gill H
Full Access

Conventional proximal tibial osteotomy is a widely successful joint-preserving treatment for osteoarthritis; however, conventional procedures do not adequately control the posterior tibial slope (PTS). Alterations to PTS can affect knee instability, ligament tensioning, knee kinematics, muscle and joint contact forces as well as range of motion. This study primarily aimed to provide a comprehensive investigation of the variables influencing PTS during high tibial osteotomy using a 3D surgical simulation approach. Secondly, it aimed to provide a simple means of implementing the findings in future 3D pre-operative planning and /or clinically. The influence of two key variables: the gap opening angle and the hinge axis orientation on PTS was investigated using three independent approaches: (1) 3D computational simulation using CAD software to perform virtual osteotomy surgery and simulate the post-operative outcome. (2) Derivation of a closed-form mathematical solution using a generalised vector rotation approach (3) Clinical assessment of synthetically generated x-rays of osteoarthritis patients (n=28; REC reference: 17/HRA/0033, RD&E NHS, UK) for comparison against the theoretical/computational approaches. The results from the computational and analytical assessments agreed precisely. For three different opening angles (6°, 9° and 12°) and 7 different hinge axis orientations (from −30° to 30°), the results obtained were identical. A simple analytical solution for the change in PTS, ΔP. s,. based on the hinge axis angle, α, and the osteotomy opening angle, θ, was derived:. ΔP. s. =sin. -1. (sin α sin θ). The clinical assessment demonstrated that the absolute values of PTS, and changes resulting from various osteotomies, matched the results from the two relative prediction methods. This study has demonstrated that PTS is impacted by the hinge axis angle and the extent of the osteotomy opening angle and provided computational evidence and analytical formula for general use