Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 51 - 51
1 Mar 2013
Smith S Li L Johnson G Joyce T
Full Access

Wear of polymeric glenoid components has been identified as a cause of loosening and failure of shoulder implants1,2 in vivo. A small number of shoulder joint simulators have been built for in vitro wear testing, however none have been capable of testing with physiological motion patterns in three axes and with physiological loading. The Newcastle Shoulder Wear Simulator was designed with three axes of motion, which are programmable so that different activities of daily living might be replicated. The simulator uses three pneumatic cylinders with integral position encoders to move five shoulder prostheses simultaneously in the flexion-extension, abduction-adduction, and internal-external rotation axes. Axial loading is applied with pneumatic cylinders supplied from a pneumatic proportional valve via a manifold, which also supplies a sixth static control station. In order to establish if that the machine can actually perform as intended, commissioning trials were conducted replicating lifting a 0.5 Kg weight to head height as a daily living activity. During the commissioning trials JRI Orthopaedics Reverse VAIOS shoulder prostheses were tested in 50% bovine serum at ambient temperature. The results show that the shoulder joint wear simulator can satisfactorily reproduce a daily living activity deliberately selected for having a large range of motion and loading. Other daily activities, such as drinking from a mug, are less demanding in the ranges of motion and loading and represent no difficulty in being reproduced on the simulator. Now successfully commissioned, this new multi-station shoulder wear simulator can wear test current and new designs of shoulder prosthesis in vitro


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 87 - 87
4 Apr 2023
Gehweiler D Pastor T Gueorguiev B Jaeger M Lambert S
Full Access

The periclavicular space is a conduit for the brachial plexus and subclavian-axillary vascular system. Changes in its shape/form generated by alteration in the anatomy of its bounding structures, e.g. clavicle malunion, cause distortion of the containing structures, particularly during arm motion, leading to syndromes of thoracic outlet stenosis etc., or alterations of scapular posture with potential reduction in shoulder function. Aim of this study was developing an in vitro methodology for systematic and repeatable measurements of the clinically poorly characterized periclavicular space during arm motion using CT-imaging and computer-aided 3D-methodologies. A radiolucent frame, mountable to the CT-table, was constructed to fix an upper torso in an upright position with the shoulder joint lying in the isocentre. The centrally osteotomized humerus is fixed to a semi-circular bracket mounted centrally at the end of the frame. All arm movements (ante-/retroversion, abduction/elevation, in-/external rotation) can be set and scanned in a defined and reproducible manner. Clavicle fractures healed in malposition can be simulated by osteotomy and fixation using a titanium/carbon external fixator. During image processing the first rib served as fixed reference in space. Clavicle, scapula and humerus were registered, segmented, and triangulated. The different positions were displayed as superimposed surface meshes and measurements performed automatically. Initial results of an intact shoulder girdle demonstrated that different arm positions including ante-/retroversion and abduction/elevation resulted solely in a transverse movement of the clavicle along/parallel to the first rib maintaining the periclavicular space. A radiolucent frame enabling systematic and reproducible CT scanning of upper torsos in various arm movements was developed and utilized to characterize the effect on the 3D volume of the periclavicular space. Initial results demonstrated exclusively transverse movement of the clavicle along/parallel to the first rib maintaining the periclavicular space during arm positions within a physiological range of motion


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 86 - 86
11 Apr 2023
Souleiman F Zderic I Pastor T Varga P Gueorguiev B Richards G Osterhoff G Hepp P Theopold J
Full Access

Osteochondral glenoid loss is associated with recurrent shoulder instability. The critical threshold for surgical stabilization is multidimensional and conclusively unknown. The aim of this work was to provide a well- measurable surrogate parameter of an unstable shoulder joint for the frequent anterior-inferior dislocation direction. The shoulder stability ratio (SSR) of 10 paired human cadaveric glenoids was determined in anterior-inferior dislocation direction. Osteochondral defects were simulated by gradually removing osteochondral structures in 5%-stages up to 20% of the intact diameter. The glenoid morphological parameters glenoid depth, concavity gradient, and defect radius were measured at each stage by means of optical motion tracking. Based on these parameters, the osteochondral stability ratio (OSSR) was calculated. Correlation analyses between SSR and all morphological parameters, as well as OSSR were performed. The loss of SSR, concavity gradient, depth and OSSR with increasing defect size was significant (all p<0.001). The loss of SSR strongly correlated with the losses of concavity gradient (PCC = 0.918), of depth (PCC = 0.899), and of OSSR (PCC = 0.949). In contrast, the percentage loss based on intact diameter (defect size) correlated weaker with SSR (PCC=0.687). Small osteochondral defects (≤10%) led to significantly higher SSR decrease in small glenoids (diameter <25mm) compared to large (≥ 25mm) ones (p ≤ 0.009). From a biomechanical perspective, the losses of concavity gradient, glenoid depth and OSSR correlate strong with the loss of SSR. Therefore, especially the loss of glenoidal depth may be considered as a valid and reliable alternative parameter to describe shoulder instability. Furthermore, smaller glenoids are more vulnerable to become unstable in case of small osteochondral loosening. On the other hand, the standardly used percentage defect size based on intact diameter correlates weaker with the magnitude of instability and may therefore not be a valid parameter for judgement of shoulder instability


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 74 - 74
1 Mar 2021
Meynen A Verhaegen F Debeer P Scheys L
Full Access

During shoulder arthroplasty the native functionality of the diseased shoulder joint is restored, this functionality is strongly dependent upon the native anatomy of the pre-diseased shoulder joint. Therefore, surgeons often use the healthy contralateral scapula to plan the surgery, however in bilateral diseases such as osteoarthritis this is not always feasible. Virtual reconstructions are then used to reconstruct the pre-diseased anatomy and plan surgery or subject-specific implants. In this project, we develop and validate a statistical shape modeling method to reconstruct the pre-diseased anatomy of eroded scapulae with the aim to investigate the existence of predisposing anatomy for certain shoulder conditions. The training dataset for the statistical shape model consisted of 110 CT images from patients without observable scapulae pathologies as judged by an experienced shoulder surgeon. 3D scapulae models were constructed from the segmented images. An open-source non-rigid B-spline-based registration algorithm was used to obtain point-to-point correspondences between the models. The statistical shape model was then constructed from the dataset using principle component analysis. The cross-validation was performed similarly to the procedure described by Plessers et al. Virtual defects were created on each of the training set models, which closely resemble the morphology of glenoid defects according to the Wallace classification method. The statistical shape model was reconstructed using the leave-one-out method, so the corresponding training set model is no longer incorporated in the shape model. Scapula reconstruction was performed using a Monte Carlo Markov chain algorithm, random walk proposals included both shape and pose parameters, the closest fitting proposal was selected for the virtual reconstruction. Automatic 3D measurements were performed on both the training and reconstructed 3D models, including glenoid version, critical shoulder angle, glenoid offset and glenoid center position. The root-mean-square error between the measurements of the training data and reconstructed models was calculated for the different severities of glenoid defects. For the least severe defect, the mean error on the inclination, version and critical shoulder angle (°) was 2.22 (± 1.60 SD), 2.59 (± 1.86 SD) and 1.92 (± 1.44 SD) respectively. The reconstructed models predicted the native glenoid offset and centre position (mm) an accuracy of 0.87 (± 0.96 SD) and 0.88 (± 0.57 SD) respectively. The overall reconstruction error was 0.71 mm for the reconstructed part. For larger defects each error measurement increased significantly. A virtual reconstruction methodology was developed which can predict glenoid parameters with high accuracy. This tool will be used in the planning of shoulder surgeries and investigation of predisposing scapular morphologies


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 23 - 23
1 Nov 2018
Sano H Komatsuda T Inawashiro T Sasaki D Noguchi M Irie T Abe H Abrassart S
Full Access

Latarjet procedure (transfer of coracoid process to the anterior glenoid rim) has been widely used for severe anterior shoulder instability. The purpose of the present study was to investigate the intraarticular stress distribution after this procedure to clarify the pathomechanism of its postoperative complications. CT-DICOM data of the contralateral healthy shoulder in 10 patients with unilateral anterior shoulder instability (9 males and 1 female, age: 17–49) was used for the present study. Three-dimensional finite element models of the glenohumeral joint was developed using software, Mechanical Finder (RCCM, Japan). In each shoulder, a 25% bony defect was created in the anterior glenoid cavity, where coracoid process was transferred using two half-threaded screws. The arm position was determined as 0-degree and 90-degree abduction. While medial margin of the scapula was completely constrained, a standard compressive load (50 N) toward the centre of the glenoid was applied to the lateral wall of the greater tuberosity. A tensile load (20N) was also applied to the tip of coracoid process along the direction of conjoint tendon. Then, elastic analysis was performed, and the distribution pattern of Drucker-Prager equivalent stress was investigated in each model. The proximal half of the coracoid represented significantly lower equivalent stress than the distal half (p < 0.05). In particular, the lowest mean equivalent stress was seen in its proximal-medial-superficial part. On the other hand, a high stress concentration newly appeared in the antero-inferior aspect of the humeral head exactly on the site of coracoid bone graft. We assumed that the reduction of mean equivalent stress in the proximal half of the coracoid was caused by the stress shielding, which may constitute one of the pathogenetic factors of its osteolysis. A high stress concentration in the humeral head may eventually lead shoulder joint to osteoarthritis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 115 - 115
1 Jan 2017
Ezzat A Chakravarty D Cairns D Craig N
Full Access

Newer irreversible oral anticoagulants such as rivaroxaban, a direct factor 10a inhibitor, are increasingly employed to prevent thromboembolic events in atrial fibrillation (AF) patients, and to manage venous thromboembolism (VTE). Unlike warfarin, these agents require no monitoring and involve infrequent dose adjustment. We report the case of a patient treated with rivaroxaban for AF. Patient presented with unprovoked sudden onset right shoulder pain which clinically resembled shoulder haemarthrosis. A single case was anonymised and retrospectively reviewed through examination of clinical and radiographic data. A 70 year old female with known AF presented to Accident and Emergency with sudden onset of right shoulder pain and limited movement, which developed over one hour. The pain was constant, localised to the shoulder and without trauma. Past medical history included severe aortic regurgitation and associated thoracic aortic aneurysm, heart failure, atrial fibrillation and hypertension. Observations were normal upon admission with no haemodynamic compromise or pyrexia. Examining the right shoulder demonstrated distension of shoulder joint capsule, tenderness and a reduced range of movement. Temperature and neurovascular status in the right arm were normal. Investigations upon admission included an INR of 1.2. An anteroposterior right shoulder radiograph showed no evidence of fracture. Patient was managed conservatively with simple oral analgesia. Importantly, rivaroxaban was withheld for 5 days and symptoms resolved. Warfarin therapy was subsequently commenced instead as treatment for AF. Patient was discharged one week later and seen in clinic two weeks post-discharge. A full recovery occurred and with a full range of movement in the right shoulder. In the UK, current National Institute for Health and Care Excellence (NICE) guidelines recommend the use of factor 10a inhibitors, for prevention of stroke in AF patients, and following elective total hip and knee replacement operations to prevent VTE. In turn, rivaroxaban is increasingly prescribed as first line therapy. Whereas warfarin has a documented association with haemarthrosis, there is no primary literature evaluating the incidence of factor 10a therapy associated haemarthrosis. In our case, the unprovoked shoulder haemarthrosis resolved following rivaroxaban cessation. In comparison with warfarin, rivaroxaban is irreversible. With warfarin and a high INR, vitamin K can be used to reverse the anticoagulation. There is no equivalent for rivaroxaban. We suggest further studies into incidence of haemarthrosis associated with oral anticoagulant therapy be undertaken, and treating physicians be aware of such complication


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1386 - 1391
1 Oct 2008
Ozbaydar M Elhassan B Esenyel C Atalar A Bozdag E Sunbuloglu E Kopuz N Demirhan M

We compared time-dependent changes in the biomechanical properties of single-and double-row repair of a simulated acute tear of the rotator cuff in rabbits to determine the effect of the fixation techniques on the healing process. A tear of the supraspinatus tendon was created in 80 rabbits which were separated into two equal groups. A single-row repair with two suture anchors was conducted in group 1 and a double-row repair with four suture anchors in group 2. A total of ten intact contralateral shoulder joints was used as a control group. Biomechanical testing was performed immediately post-operatively and at four and eight weeks, and histological analysis at four and eight weeks. The mean load to failure in group 2 animals was greater than in group 1, but both groups remained lower than the control group at all intervals. Histological analysis showed similar healing properties at four and eight weeks in both groups, but a significantly larger number of healed tendon-bone interfaces were identified in group 2 than in group 1 at eight weeks (p < 0.012). The ultimate load to failure increased with the number of suture anchors used immediately post-operatively, and at four and eight weeks. The increased load to failure at eight weeks seemed to be related to the increase in the surface area of healed tendon-to-bone in the double-row repair group


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 48 - 48
1 Aug 2013
Lomax A Fazzi U Watson M
Full Access

Single shot interscalene blocks are an effective analgesic for arthroscopic shoulder surgery. However, patients receiving these blocks are often found to be in significant pain when the block wears off, usually in the late evening or early hours of the morning. Overnight admission is currently routine in our unit, to ensure adequate analgesia can be administered during this period. Recent studies have suggested that adding dexamethasone to the local anaesthetic agent can prolong the duration of the block. We carried out a prospective study to assess whether addition of dexamethasone to brachial plexus blocks could reduce patient's post-operative analgesic demands and allow safe discharge on the same day after surgery. Twenty-six patients undergoing arthroscopic shoulder surgery during a morning theatre list, had ultrasound guided brachial plexus blocks using a mixture of 0.25% bupivacaine 20–30ml with 2–3mg of dexamethasone. All were admitted to the ward afterwards for analgesia and physiotherapy. Pain numerical rating scores (0–10) were recorded at rest in recovery one hour postoperatively by the attending anaesthetist and on active movement of the shoulder joint 24 hours after surgery by the attending physiotherapist. A standardised analgesia regime was prescribed with regular and as required medication, including as required strong opiates. Mean pain scores in recovery were 0.31 and on the morning after surgery were 2.38. Sixteen out of 26 required no further analgesia, with only 3 out of the 10 who did requiring opiates. The use of dexamethasone provides adequate analgesia for a prolonged period for most patients after brachial plexus block for shoulder surgery and does not result in a significant analgesic requirement when the block wears off. This may provide support for avoiding overnight admission in selected patients after arthroscopic shoulder surgery


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 177 - 177
1 Jul 2014
Razmjou H Henry P Dwyer T Holtby R
Full Access

Summary. Analysis of existing data of patients who had undergone debridement procedure for osteoarthritis (OA) of glenohumeral joint showed improvement in disability at a minimum of one year following surgery. Injured workers were significantly younger and had a poorer outcome. Introduction. There is little information on debridement for OA of the shoulder joint. The purpose of this study was to examine factors that affect the outcome of arthroscopic debridement with or without acromioplasty /resection of clavicle of patients with osteoarthritis of the glenohumeral joint, in subjective perception of disability and functional range of motion and strength at a minimum of one year following surgery. Patients and Methods. Existing data of patients with advanced OA of the glenohumeral joint who had undergone debridement were used for analysis. These patients were not good candidates for shoulder arthroplasty due to a young age, high activity level, or desire to avoid major surgery at the time of assessment. Arthroscopic debridement included removal of loose bodies, chondral flaps, and degenerative tissue. Resection of the lateral end of the clavicle or acromioplasty was performed as clinically indicated for management of osteoarthritis of the Acromioclavicular (AC) joint or subacromial impingement respectively. Disability at a minimum of 12 months following surgery was measured by the American Shoulder and Elbow Surgeon's (ASES) assessment form, Constant-Murley score (CMS), strength, and painfree range of motion (ROM) in four directions. Impact of sex, age, having acromioplasty or resection of clavicle, and having an active work-related compensation claim was examined. Results. Seventy-four patients (mean age= 55, SD: 14 (range: 25–88), range: 35–86, 34 females, 40 males) were included in analysis. The average symptom duration was 5.8 years. Fifty nine (80%) patients had an associated subacromial decompression [55 (74%) had acromioplasty, 32(43%) had resection of the lateral end of the clavicle, and 28 (38%) had both procedures]. Nineteen (26%) patients had a work-related compensation claim related to their shoulder. This group was significantly younger than the non-compensation group (45 vs. 58, p=0.0001). Paired student t-tests showed a statistically significant improvement in scores of ASES and CMS (p<0.0001), strength (p=0.001) and painfree range of motion (p=0.01) at a minimum of 1 year follow-up. The ANCOVA model that incorporated sex, age, additional decompression (AC resection or acromioplasty), compensation claim and pre-op scores, showed that the pre-op scores and having a work-related claim were the most influential predictors of post-op scores of ASES, CMS, and ROM. The post-op strength was the only factor that was affected by sex, age and having a work-related claim. Discussion/Conclusion. Arthroscopic debridement with or without acromioplasty /resection of the lateral end of the clavicle improved disability, painfree range of motion and strength in patients suffering from osteoarthritis of glenohumeral joint at a minimum of one year following surgery. Patients with an active compensation claim related to their shoulder were significantly younger and had a poorer outcome


Objectives

Adult mice lacking the transcription factor NFAT1 exhibit osteoarthritis (OA). The precise molecular mechanism for NFAT1 deficiency-induced osteoarthritic cartilage degradation remains to be clarified. This study aimed to investigate if NFAT1 protects articular cartilage (AC) against OA by directly regulating the transcription of specific catabolic and anabolic genes in articular chondrocytes.

Methods

Through a combined approach of gene expression analysis and web-based searching of NFAT1 binding sequences, 25 candidate target genes that displayed aberrant expression in Nfat1-/- AC at the initiation stage of OA, and possessed at least four NFAT1 binding sites in the promoter of each gene, were selected and tested for NFAT1 transcriptional activities by chromatin immunoprecipitation (ChIP) and promoter luciferase reporter assays using chondrocytes isolated from the AC of three- to four-month-old wild-type mice or Nfat1-/- mice with early OA phenotype.


Bone & Joint Research
Vol. 7, Issue 4 | Pages 274 - 281
1 Apr 2018
Collins KH Hart DA Seerattan RA Reimer RA Herzog W

Objectives

Metabolic syndrome and low-grade systemic inflammation are associated with knee osteoarthritis (OA), but the relationships between these factors and OA in other synovial joints are unclear. The aim of this study was to determine if a high-fat/high-sucrose (HFS) diet results in OA-like joint damage in the shoulders, knees, and hips of rats after induction of obesity, and to identify potential joint-specific risks for OA-like changes.

Methods

A total of 16 male Sprague-Dawley rats were allocated to either the diet-induced obesity group (DIO, 40% fat, 45% sucrose, n = 9) or a chow control diet (n = 7) for 12 weeks. At sacrifice, histological assessments of the shoulder, hip, and knee joints were performed. Serum inflammatory mediators and body composition were also evaluated. The total Mankin score for each animal was assessed by adding together the individual Modified Mankin scores across all three joints. Linear regression modelling was conducted to evaluate predictive relationships between serum mediators and total joint damage.


Bone & Joint Research
Vol. 5, Issue 12 | Pages 602 - 609
1 Dec 2016
Muto T Kokubu T Mifune Y Inui A Sakata R Harada Y Takase F Kurosaka M

Objectives

Triamcinolone acetonide (TA) is widely used for the treatment of rotator cuff injury because of its anti-inflammatory properties. However, TA can also produce deleterious effects such as tendon degeneration or rupture. These harmful effects could be prevented by the addition of platelet-rich plasma (PRP), however, the anti-inflammatory and anti-degenerative effects of the combined use of TA and PRP have not yet been made clear. The objective of this study was to determine how the combination of TA and PRP might influence the inflammation and degeneration of the rotator cuff by examining rotator cuff-derived cells induced by interleukin (IL)-1ß.

Methods

Rotator cuff-derived cells were seeded under inflammatory stimulation conditions (with serum-free medium with 1 ng/ml IL-1ß for three hours), and then cultured in different media: serum-free (control group), serum-free + TA (0.1mg/ml) (TA group), serum-free + 10% PRP (PRP group), and serum-free + TA (0.1mg/ml) + 10% PRP (TA+PRP group). Cell morphology, cell viability, and expression of inflammatory and degenerative mediators were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 977 - 983
1 Jul 2007
Lee JH Prakash KVB Pengatteeri YH Park SE Koh HS Han CW

We attempted to repair full-thickness defects in the articular cartilage of the trochlear groove of the femur in 30 rabbit knee joints using allogenic cultured chondrocytes embedded in a collagen gel. The repaired tissues were examined at 2, 4, 8, 12 and 24 weeks after operation using histological and histochemical methods. The articular defect filling index measurement was derived from safranin-O stained sections. Apoptotic cellular fractions were derived from analysis of apoptosis in situ using TUNEL staining, and was confirmed using caspase-3 staining along with quantification of the total cellularity. The mean articular defect filling index decreased with time. After 24 weeks it was 0.7 (sd 0.10), which was significantly lower than the measurements obtained earlier (p < 0.01). The highest mean percentage of apoptotic cells were observed at 12 weeks, although the total cellularity decreased with time. Because apoptotic cell death may play a role in delamination after chondrocyte transplantation, anti-apoptotic gene therapy may protect transplanted chondrocytes from apoptosis.