Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXII | Pages 58 - 58
1 May 2012
Parker L Smitham P McCarthy I Garlick N
Full Access

Conventionally, medial malleolus fractures are treated surgically with anatomical reduction and internal fixation using screws. There seems to be no consensus, backed by scientific study on the optimal screw characteristics in the literature.

We retrospectively examined case notes and radiographs of 48 consecutive patients taken from our trauma database (21 male, 27 female) with an average age of 50 years (range 16-85) who had undergone medial malleolus fracture fixation with screws at the Royal Free Hospital, London between January 2009 and June 2010.

The most commonly used screw was the AO 4.0 mm diameter cancellous partially-threaded screw in 40, 45 and 50 mm lengths (40 mm n = 28, 45 mm n = 26, 50 mm n = 23) with the threads passing beyond the physeal scar in all cases. Incomplete reduction defined as > 1mm fracture displacement was observed on post-operative x-rays in 12 out of 48 cases (25%), all of which relied on partially-threaded screw fixation. In 5 cases where AO 4.0 mm diameter fully-threaded screws engaging the physeal scar had been used, no loss of reduction was observed.

This unusual, occasional use of fully-threaded screws prompted us to investigate further using a porcine model and adapted pedo-barographic transducer. We compared pressures generated within the fracture site using AO 4.0 mm partially-threaded cannulated screws, 4.0 mm partially-threaded cancellous screws and 4.0 mm fully-threaded cancellous screws.

Fully-threaded cancellous 4.0 mm diameter screws generated almost 3 times the compression of a partially-threaded cancellous screw with superior stability at the fracture. Partially-threaded screws quickly lost purchase, compression and stability particularly when they were cannulated. We also observed that screw thread purchase seemed enhanced in the physeal region.

We conclude that fully-threaded cancellous 4.0 mm AO screws are superior to longer partially-threaded screws and that use of cannulated 4.0 mm partially-threaded screws should be avoided in fixation of medial malleolus fractures.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 16 - 16
1 Dec 2015
Shivji F Weston S Addison T Erskine R Milner S
Full Access

Purpose

Ankle and hindfoot surgery is associated with severe post-operative pain, leading to a reliance on opiate analgesia and its side effects, longer hospital stays, and patient dissatisfaction. Popliteal sciatic nerve blockade has the potential to resolve these issues. We present our experience with using a continuous local anaesthetic nerve block delivered by an elastomeric pump in patients undergoing major foot and ankle surgery.

Methods

All patients undergoing major ankle or hindfoot surgery during a one-year period under a single surgeon were eligible for a continuous popliteal block. An ultrasound-guided popliteal nerve catheter was inserted immediately before surgery and a bolus of bupivacaine infiltrated. Using a 250ml elastomeric pump, a continuous infusion was started immediately post operatively and terminated 48 hours later. Prospective data including post-operative analgesia, nausea and vomiting (PONV), length of stay (LOS), pain scores, and patient satisfaction were recorded daily for 48 hours post operatively.