Introduction. The pathophysiology of osteonecrosis of femoral head (ONFH) is uncertain for most cases with speculation of vascular impairment and changes in cell biology due to multi-factorial etiologies including corticosteroid, alcohol, smoking, trauma, radiation or caisson disease and genetic. Extracorporeal shockwave therapy (ESWT) began with an incidental observation of osteoblastic response pattern during animal studies in the mid-1980 that generated an interest in the application of ESWT to musculoskeletal disorders. The mechanism of shockwave therapy is not fully understood but several reports showed better clinical outcomes and promoted bone remodelling and regeneration effect of the femoral head after ESWT in ONFH. Therefore, we compared the clinical results of the use of extracorporeal
Paediatric bone and joint infections remain common in low- and middle-income countries (LMICs). We aimed to determine the complication rate and incidence of disseminated infection in paediatric bone and joint infections in an LMIC setting. Secondly, we aimed to elucidate factors associated with complications and disseminated disease. We retrospectively reviewed our database for children that presented with bone and joint infections between September 2015 and March 2019. Data were extracted to identify factors that were associated with development of complications and disseminated infection. We analysed 49 children. The median age at presentation was 6 years (range 1 month to 12 years). Locally advanced disease was present in 13 children (27%). The remaining 36 children were evenly divided (18/49 each, 37%) between isolated AHOM and SA, respectively. Disseminated disease was present in 16 children (33%) and was associated with locally advanced disease, an increase in number of surgeries and an increased length of stay. Twenty-six complications were documented in 22 (45%) children. Chronic osteomyelitis developed in 15/49 (31%) cases, growth arrest in 5/49 (10%), and pathological fracture, DVT and septic
Aim. The aim of our study was to analyze putative genes for virulence factors of Cutibacterium isolates obtained from implant-associated infections. Methods. We analyzed 64 isolates of Cutibacterium spp. (C. acnes (53/64), C. avidum (6/64), C. granulosum (4/64), C. namnetense (1/64)) using NextSeq 550 (Illumina, San Diego, CA, USA) and performed genomic analysis of 24 genes associated with virulence factors (VFs) of C. acnes previously reported in the literature. Most isolates were obtained from implant-associated infections (IAI) between 2012–2021 at the Institute of Microbiology and Immunology, Faculty of Medicine, Ljubljana. Additionally, we included the first C. namnetense isolated in our laboratory from surgical site infection. Results. C. acnes and C. namnetense have the highest number of VFs among those examined. The VFs gntK (shikimate kinase) and HYL-IB / II (hyaluronate lyase) are absent in phylotype IA. 1. (sequence types (ST) A, C, D according to the SLST scheme). Repressor gene of porphyrin synthesis, deoR is present in all Cutibacterium spp. isolates. The phylotypes II and IB show a similar distribution of VFs, with the presence of the VFs rcsB (compound for biofilm formation) and HYL-IA (hyaluronate lyase), which are absent in other C. acnes phylotypes and other Cutibacterium spp. In phylotypes IA. 1. and IB, the sequence of genes encoding VFs dsA1 and dsA2 does not have 100% genomic coverage, possibly indicating homologs between species. The isolates of C. acnes and C. namnetense possess all three CAMP (1,2,4) factors, which are not detected in other Cutibacterium spp. However, further analysis revealed species-specific CAMP factors in C. avidum and C. granulosum. Both species also have similar other genes for VFs, mainly encoding heat
Aim. A novel anti-infective biopolymer implant coating was developed to prevent bacterial biofilm formation and allow on-demand burst release of anti-infective silver (Ag) into the surrounding of the implant at any time after surgery via focused high-energy extracorporeal
A retrospective case control study of all rehabilitated patients who suffered amputations of the lower extremity by sepsis was performed in the HELIOS centre of rehabilitation for amputees, Bad Berleburg, Germany. This study examines patients who had undertaken an amputation of the lower extremity caused by severe sepsis and septic
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and toxic
Objective. This paper aims to analyze the kinetics of the over-ground wheel-type body weight supporting system (BWS); tendency changes of low extremity joint moment (hip, knee, ankle), 3 axis accelerations of a trunk, cadence and gait velocity as weight bearing level changes. Method. 15 subjects (11 males, 4 females, age:23.63.5, height:170.65.1cm, weight:69.0210.75kg) who had no history of surgery participated. 6 levels (0%, 10%, 20%, 30%, 40% and 50%) of BWS were given to subjects at self-selected gait velocity and kinetic data was calculated using a motion capture system, Vicon. ®. (Vicon, UK). Results. Maximum joint moments at the hip, knee, and ankle decrease as weight bearing increases on the sagittal plane. However, no significant decrease was found after 20% level of BWS at the hip and knee joint. On the other hand, the maximum ankle joint moment keeps decreasing. The root mean square (RMS) values of the acceleration in three directions: anterior-posterior (AP), medial-lateral (ML), and vertical(V) are analyzed. All 3-dimensional accelerations decrease as BWS increases while there is no significant difference over 20% level of BWS in the ML acceleration. V acceleration is reduced almost by half as soon as BWS level starts, but no further significant decrease can be found after 30% level of BWS. The AP acceleration tends to keep decreasing as BWS level increases. The cadence and gait velocity with wheel-type BWS decreases as BWS increases. Discussion. The maximum joint moments of the hip and knee do not significantly decrease when BWS exceeds a certain level, which is different from the case with BWS on treadmill; the maximum moments tend to keep decreasing linearly as BWS level increases on treadmill. In the case of the hip joint, the maximum moment is generated between toe-off and pre-swing phase, which generates force to push a trunk forward. With higher BWS, forward progression of the trunk is assisted by the wheel rather than driven by the lower extremity. It should be noticed that not only the tendency is different from BWS on treadmill, but the magnitude of the maximum hip moment is smaller than that of BWS on treadmill when BWS level is over 20%. The maximum knee joint moment is generated at the loading-response phase working as braking and
Anterior cruciate ligament (ACL) rupture with associated meniscal pathology commonly occurs in a young, active population. Preserving a greater proportion of the meniscus may improve long-term outcomes by maintaining
Previous studies have indicated that prolonged surgical time may lead to higher rates of infection following total hip arthroplasty (THA). The purpose of this study was to evaluate the influence of surgical time on 30-day complications following THA and to determine if there was a time interval associated with worse outcomes. Patients ≥18 years who underwent THA between 2005 and 2016 were identified from the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database using procedural codes. Patients with surgical durations >240 minutes were excluded. Patient demographics, operation length, and 30-day major and minor complications were ascertained. Multivariable regression was used to determine if the rate of complications differed depending on length of operation, while adjusting for relevant covariables, and to identify independent predictors of operation length. Covariables of interest included age, sex, American Society of Anaesthesiologists (ASA) class, smoking status, functional status, comorbidities, anesthesia type, and Body Mass Index (BMI). A total of 131,361 THA patients (average age 65 ±12 years) were identified from the database. Of these, 2,177 (1.64%) experienced a major complication, and 3,504 (2.64%) experienced a minor complication within 30-days of the initial procedure. Average operation length was 91.9 minutes (range 20 – 240 minutes). Independent predictors of prolonged operation length included overweight/obese BMI, male sex, cancer, dependent functional status, epidural anaesthetic, lower pre-operative hematocrit, and ASA class II, III or IV vs. I Alternatively, older age, current smoking, and spinal anaesthetic were associated with shorter surgical durations. Unadjusted rates of both major and minor complications were significantly higher for patients whose operation lengths were ≥ 120 minutes (P>0.001). Specifically, patients whose operations lasted ≥ 120 minutes had higher rates of septic
DAIR procedure is well established for Prosthetic Joint Infection (PJI) in acute setting after total hip and knee replacements. We present our experience of DAIR following hip and knee replacements in a District General Hospital (DGH), where we delivered comparable results to leading tertiary centres in short to mid-term followup. We undertook a retrospective study involving 14 patients, who underwent DAIR in our DGH between August 2012 and December 2015. Patient cohort included primary, complex primary and revision hip and knee replacements. Microbiological support was provided by a Microbiologist with interest in musculoskeletal infections. 14 patients [9 males, 5 females; age 62 to 78 years (Mean 70.7); BMI 22 to 44.2 (Mean 33.8)] with multiple comorbidities underwent DAIR procedure within 3 weeks of onset of symptoms. 12 out of 14 grew positive cultures with two growing Vancomycin resistant Enterococci. Intravenous antibiotics were started after multiple samples intraoperatively and continued in six patients after discharge, while 8 were discharged with oral antibiotics. One patient died of overwhelming intraoperative septic
To evaluate efficacy and outcome of embolisation following pelvic ring injuries in patients presented with ongoing hypovolaemic
The meniscus is at the cornerstone of knee joint function, imparting stability and ensuring
Purpose. Total knee replacement is the one of the most performed surgeries. However, patient's satisfaction rate is around 70–90 % only. The sacrifice of cruciate ligament might be the main reason, especially in young and active patients. ACL stabilizes the knee by countering the anterior displacing and pivoting force, absorbs the
INTRODUCTION. Lumbar total disc replacement (TDR) is an alternative treatment to avoid fusion related adverse events, specifically adjacent segment disease. New generation of elastomeric non-articulating devices have been developed to more effectively replicate the
Introduction. The viscoelastic cervical disk prosthesis CP-ESP is an innovative one-piece deformable but cohesive interbody spacer. It is an evolution of the LP-ESP lumbar disk implanted since 2006. The implant provides 6 full degrees of freedom including
High-energy pelvic ring fractures are associated with polytrauma where staged surgery is recommended. While temporary skeletal stabilisation is part of the acute management, definitive care is done in a later phase. The purpose of this study was to evaluate the safety and efficacy of acute pelvic ORIF by comparing its short term outcome with those who were stabilised late. A 45-month retrospective review of the prospective pelvic fracture database of a level one trauma centre was performed. All high-energy trauma patients who were potential candidates for minimally invasive internal fixation of the pelvic ring were included. Patients were categorised as acute ORIF (<24 hrs) or late ORIF (>24 hrs). Demographics, ISS, pelvic AIS, 24 hour pack cell transfusions, physiological parameters, time to operating theatre, angiography requirement, LOS and mortality were recorded. Data was presented as mean+/−SD or percentages. Statistical significance was determined at ∗p<0.05 based on univariate analysis. Forty-three patients met inclusion criteria, seventeen patients had acute definitive ORIF (5.5 hrs to OT) and twenty-six late definitive ORIF (5 days to OT). Acute and late ORIF patients had statistically not different demographics (age: 48+/−22 years vs 40+/− 14, gender: 82% vs 79% males), injury severity (ISS: 30+/−18 vs 24.5+/−13, pelvic AIS: 3.7+/− 1 vs 3.4+/− 1.1) and 24 hour transfusion (4.7+/−5 U vs 6.6+/−4 U). Initial
This study aimed to investigate the risk of postoperative complications in COVID-19-positive patients undergoing common orthopaedic procedures. Using the National Surgical Quality Improvement Programme (NSQIP) database, patients who underwent common orthopaedic surgery procedures from 1 January to 31 December 2021 were extracted. Patient preoperative COVID-19 status, demographics, comorbidities, type of surgery, and postoperative complications were analyzed. Propensity score matching was conducted between COVID-19-positive and -negative patients. Multivariable regression was then performed to identify both patient and provider risk factors independently associated with the occurrence of 30-day postoperative adverse events.Aims
Methods
Introduction. Aseptic acetabular component failure rates have been reported to be similar or even slightly higher than femoral component failure. Obtaining proper initial stability by press fitting the cementless acetabular cup into an undersized cavity is crucial to allow for secondary osseous integration. However, finding the insertion endpoint that corresponds to an optimal initial stability is challenging. This in vitro study presents an alternative method that allows tracking the insertion progress of acetabular implants in a non-destructive, real-time manner. Materials and Methods. A simplified acetabular bone model was used for a series of insertion experiments. The bone model consisted of polyurethane solid foam blocks (Sawbones #1522-04 and #1522-05) into which a hemispherical cavity and cylindrical wall, representing the acetabular rim, were machined using a computer numerically controlled (CNC) milling machine (Haas Automation Inc., Oxnard, CA, USA). Fig. 1 depicts the bone model and setup used. A total of 10 insertions were carried out, 5 on a low density block, 5 on a high density block. The acetabular cups were press fitted into the bone models by succeeding hammer hits. The acceleration of the implant-insertor combination was measured using 2
London's Air Ambulance (LAA) was first set-up in 1989 as a direct result of a Royal College of Surgeons of England Report highlighting poor trauma care provision. Since its inception, the service's mission is to be an innovative and effective provider of advanced pre-hospital care. The service provides a senior Doctor and senior Paramedic to the scene of any incident within the M25 by helicopter, during the day, and by fast-response car at night. The vast majority of doctors are usually Emergency Medicine Physicians or Anaesthetists. During a 6-month tenure, doctors will usually have completed a number of procedures, which include rapid sequence induction of anaesthesia, pre-hospital blood transfusion, and, procedural sedation. In terms of innovations, the organisation was the first in the UK to provide a 24/7 service. It was also the first to start pre-hospital Rapid Sequence Induction of Anaesthesia for the severely injured; Resuscitative Thoracotomy for the victims of penetrating trauma; and pre-hospital Blood Transfusion for
Military personnel operating on high speed marine craft are exposed to Whole-Body Vibration (WBV). Additionally planing craft operate at speeds with minimal contact of the hull with warer making the crew vulnerable to mechanical