Advertisement for orthosearch.org.uk
Results 1 - 20 of 72
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1045 - 1050
1 Aug 2012
Malek IA King A Sharma H Malek S Lyons K Jones S John A

Plasma levels of cobalt and chromium ions and Metal Artefact Reduction Sequence (MARS)-MRI scans were performed on patients with 209 consecutive, unilateral, symptomatic metal-on-metal (MoM) hip arthroplasties. There was wide variation in plasma cobalt and chromium levels, and MARS-MRI scans were positive for adverse reaction to metal debris (ARMD) in 84 hips (40%). There was a significant difference in the median plasma cobalt and chromium levels between those with positive and negative MARS-MRI scans (p < 0.001). Compared with MARS-MRI as the potential reference standard for the diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt or chromium with a cut-off of > 7 µg/l was 57%. The specificity was 65%, positive predictive value was 52% and the negative predictive value was 69% in symptomatic patients. A lowered threshold of > 3.5 µg/l for cobalt and chromium ion levels improved the sensitivity and negative predictive value to 86% and 74% but at the expense of specificity (27%) and positive predictive value (44%).

Metal ion analysis is not recommended as a sole indirect screening test in the surveillance of symptomatic patients with a MoM arthroplasty. The investigating clinicians should have a low threshold for obtaining cross-sectional imaging in these patients, even in the presence of low plasma metal ion levels.


Bone & Joint Research
Vol. 12, Issue 9 | Pages 590 - 597
20 Sep 2023
Uemura K Otake Y Takashima K Hamada H Imagama T Takao M Sakai T Sato Y Okada S Sugano N

Aims. This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. Methods. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm. 3. ). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. Results. CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm. 2. . Conclusion. Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery. Cite this article: Bone Joint Res 2023;12(9):590–597


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims. Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results. Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion. We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 760 - 767
1 Jul 2023
Tanaka S Fujii M Kawano S Ueno M Sonohata M Kitajima M Mawatari D Mawatari M

Aims. The aims of this study were to validate the Forgotten Joint Score-12 (FJS-12) in the postoperative evaluation of periacetabular osteotomy (PAO), identify factors associated with joint awareness after PAO, and determine the FJS-12 threshold for patient-acceptable symptom state (PASS). Methods. Data from 686 patients (882 hips) with hip dysplasia who underwent transposition osteotomy of the acetabulum, a type of PAO, between 1998 and 2019 were reviewed. After screening the study included 442 patients (582 hips; response rate, 78%). Patients who completed a study questionnaire consisting of the visual analogue scale (VAS) for pain and satisfaction, FJS-12, and Hip disability and Osteoarthritis Outcome Score (HOOS) were included. The ceiling effects, internal consistency, convergent validity, and PASS thresholds of FJS-12 were investigated. Results. The median follow-up was 12 years (interquartile range 7 to 16). The ceiling effect of FJS-12 was 7.2%, the lowest of all the measures examined. FJS-12 correlated with all HOOS subscales (ρ = 0.72 to 0.77, p < 0.001) and pain and satisfaction-VAS (ρ = -0.63 and 0.56, p < 0.001), suggesting good convergent validity. Cronbach’s α was 0.95 for the FJS-12, which indicated excellent internal consistency. The median FJS-12 score for preoperative Tönnis grade 0 hips (60 points) was higher than that for grade 1 (51 points) or 2 (46 points). When PASS was defined as pain-VAS < 21 and satisfaction-VAS ≥ 77, the FJS-12 threshold that maximized the sensitivity and specificity for detecting PASS was 50 points (area under the curve (AUC) = 0.85). Conclusion. Our results suggest that FJS-12 is a valid and reliable assessment tool for patients undergoing PAO, and the threshold of 50 points may be useful to determine patient satisfaction following PAO in clinical settings. Further investigation of the factors influencing postoperative joint awareness may enable improved prediction of treatment efficacy and informed decision-making regarding the indication of PAO. Cite this article: Bone Joint J 2023;105-B(7):760–767


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 40 - 40
1 Jul 2020
Bhaskar D Higgins M Mosby D Townsend R Harrison T
Full Access

Literature debates whether fluid aspirates for suspected PJI should undergo prolonged incubation for cultures. We looked at sensitivity and specificity of 14-day cultures, compared to 7-days, for aspirates from prosthetic hips and knees. Design and methods. Conducted at a quaternary referral centre for PJIs from Jan 2017 to July 2019. Suspected PJIs who underwent aspiration, incubated 14 days and later surgical intervention with minimum three tissue samples were included. Results. 176 aspirates were included. This is an increased number compared to our historic figures (average 88 Vs 48 pts/yr). 47 patients had fluid and tissue positive (true positive), 20 fluid +ive but tissue -ive (false positive), 98 fluid and tissue -ive (true negative) and 15 fluid negative but tissue +ive (False negative). Thus, sensitivity 76%, specificity 83%, positive predictive value70% and negative predictive value 87%. Of 88 positive aspirates, only 75% were within 7-day cultures. Low virulence organisms as Propionibacterium acnes and coagulase negative staph were grown later. Of 48 with only one tissue sample positive, 38 were culture-negative on aspiration and 6 grew different organisms on aspirate and tissues. Also, as many were cultured later, it suggests contamination. Conclusion. Increased numbers reflect quaternary referral nature of institution and increasing PJI load. Modest drop in sensitivity and specificity of 14-day cultures compared to 7-day(84 and 85% respectively) is due to higher false negatives. Contamination contributes to false-ive as more tissue samples become positive (there were 1076 tissue samples due to multiple sampling Vs 176 aspirates). Higher tissue yield may also be because they are more representative. Effect of antibiotic use between samples cannot be determined. Organism profile suggest14-day culture produces more contaminant growth despite a well-equipped microbiology lab with laminar airflow for subcultures. Caution in interpreting 14-day results in diagnosis of PJI of Hip and Knee is advised


Bone & Joint Open
Vol. 3, Issue 4 | Pages 307 - 313
7 Apr 2022
Singh V Bieganowski T Huang S Karia R Davidovitch RI Schwarzkopf R

Aims. The Forgotten Joint Score-12 (FJS-12) is a validated patient-reported outcome measure (PROM) tool designed to assess artificial prosthesis awareness during daily activities following total hip arthroplasty (THA). The patient-acceptable symptom state (PASS) is the minimum cut-off value that corresponds to a patient’s satisfactory state-of-health. Despite the validity and reliability of the FJS-12 having been previously demonstrated, the PASS has yet to be clearly defined. This study aims to define the PASS of the FJS-12 following primary THA. Methods. We retrospectively reviewed all patients who underwent primary elective THA from 2019 to 2020, and answered both the FJS-12 and the Hip Disability and Osteoarthritis Outcome Score, Joint Replacement (HOOS, JR) questionnaires one-year postoperatively. HOOS, JR score was used as the anchor to estimate the PASS of FJS-12. Two statistical methods were employed: the receiver operating characteristic (ROC) curve point, which maximized the Youden index; and 75th percentile of the cumulative percentage curve of patients who had the HOOS, JR score difference larger than the cut-off value. Results. This study included 780 patients. The mean one-year FJS-12 score was 65.42 (SD 28.59). The mean one-year HOOS, JR score was 82.70 (SD 16.57). A high positive correlation between FJS-12 and HOOS, JR was found (r = 0.74; p<0.001), making the HOOS, JR a valid external anchor. The threshold score of the FJS-12 that maximized the sensitivity and specificity for detecting a PASS was 66.68 (area under the curve = 0.8). The cut-off score value computed with the 75th percentile approach was 92.20. Conclusion. The PASS threshold for the FJS-12 at one year following primary THA was 66.68 and 92.20 using the ROC curve and 75th percentile approaches, respectively. These values can be used to achieve consensus about meaningful postoperative improvement to maximize the utility of the FJS-12 to evaluate and counsel patients undergoing THA. Cite this article: Bone Jt Open 2022;3(4):307–313


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 372 - 377
1 Apr 2019
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E

Aims. Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection. Patients and Methods. A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields. Results. The sensitivity and specificity of the LE assay were 100% and 93.8%, respectively; the positive (PPV) and the negative (NPV) predictive values were 79.3% and 100%, respectively. The mean time between the collection of the sample and the result being known was 20.1 minutes (. sd. 4.4). The sensitivity and specificity of FS histology were 78.3% and 96.9%, respectively; the PPV and the NPV were 85.7% and 94.9%, respectively. The mean time between the collection of the sample and the result being known was 27.2 minutes (. sd. 6.9). Conclusion. The sensitivity of LE assay was higher, with similar specificity and diagnostic accuracy, compared with FS histology. The faster turnaround time, its ease of use, and low costs make LE assay a valuable alternative to FS histology. We now use it routinely for the intraoperative diagnosis of PJI. Cite this article: Bone Joint J 2019;101-B:372–377


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 83 - 83
19 Aug 2024
Tarabichi S Lizcano JD Abe EA Olin B Courtney PM Parvizi J
Full Access

No single test has demonstrated absolute accuracy in the diagnosis of periprosthetic joint infection (PJI). Leukocyte esterase (LE) is a synovial marker that has proven utility in the diagnosis of PJI. The purpose of this prospective study was to (1) identify the optimal cutoff for the use of LE in the diagnosis of PJI and (2) determine whether performance of the LE strip test varied by infecting organism. This prospective study enrolled 1,015 patients undergoing hip or knee revision arthroplasty at a single institution from 2009 to September 2021. PJI was defined using a modified version of 2018 International Consensus Meeting (ICM) criteria that excluded LE when calculating the ICM score. Receiver operating characteristic curves were used to assess the utility of the LE strip test in the diagnosis of PJI. 973 patients were included in the analyses. 246 (25.4%) were classified as ICM-positive and 727 (74.6%) were classified as ICM-negative. An LE cutoff of “1+” (AUC 0.819, sensitivity 73.2%, specificity 90.6%) had superior accuracy to an LE cutoff of “2+” (AUC 0.713, sensitivity 43.9%, specificity 98.8%) in the overall diagnosis of PJI (p<0.001). When stratifying by organism type, an LE cutoff of “1+” had the best diagnostic utility for PJI caused by methicillin resistant Staphylococcus aureus (AUC 0.888, sensitivity 87.0%, n=23) followed by Streptococcus spp. (AUC 0.882, sensitivity 85.7%, n=28), coagulase negative Staphylococci (AUC 0.836, sensitivity 76.6%, n=47), methicillin sensitive Staphylococcus aureus (AUC 0.806, sensitivity 70.6%, n=34), culture negative (AUC 0.793, sensitivity 67.9%, n=56), and gram negative rods (AUC 0.763, sensitivity 61.9%, n=21). To our knowledge, this is the largest study evaluating the utility of the LE strip test in the diagnosis of PJI. Based on our findings, it appears that a “1+” cutoff has higher diagnostic utility than a cutoff of “2+”


Introduction. Pre-operative aspiration and culture is the gold standard for the diagnosis of peri-prosthetic infection. This study aimed to ascertain the diagnostic accuracy of culture of joint aspiration with or without saline re-aspiration in the event of a dry-tap. Patients/Materials & Methods. Retrospective analysis of 343 hip aspirations in patients deemed to have moderate-high risk of infection and ultimately proceeded to revision arthroplasty over 12 years at a large quaternary referral centre where pre-operative aspiration is routine. Results. Fluid was aspirated in 141(41%) cases and dry taps in which saline injection-re-aspiration was performed occurred in 202 (59%) cases. Overall sensitivity and specificity of diagnostic aspirate were 82% (74–88%) and 79% (74–84%) respectively. Sensitivity and specificity of saline injection-re-aspiration after dry tap were 79% (64–87%) and 86% (78–92%) compared to 84% (74–91%) and 74% (66–81%) for direct aspiration. Discussion. Pre-operative joint aspiration and culture is a sensitive and specific test for the confirmation of diagnosis in patients at a moderate to high risk of prosthetic joint infection. Culture of saline injection-re-aspiration also provides accurate diagnostic information in the event of a dry tap. Both methods allow susceptibility testing of relevant organisms and are therefore able to guide peri-operative and cement instilled antibiotic therapy. Conclusions. Culture of pre-operative joint aspirates provides sensitive and specific diagnostic information, including antimicrobial susceptibility results. Saline injection-re-aspiration is a useful additional technique in those patients in whom fluid cannot be aspirated


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 27 - 27
1 Aug 2018
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E
Full Access

Leukocyte esterase (LE) has shown to be an accurate marker of prosthetic joint infections and has been proposed as an alternative to frozen section (FS) for intra-operative diagnosis. In this study, intra-operative determination of LE was compared with FS for the diagnosis of periprosthetic hip infections. One hundred and nineteen patients undergoing hip revision surgery due to prosthetic joint failure from June 2015 to December 2017 were considered. Joint fluids were collected before the arthrotomy for determination of LE which was performed by using enzymatic colorimetric strips. Four to six samples were stained with hematoxylin eosin for FS and considered suggestive for infection when at least 5 polymorphonuclear leukocytes in 5 fields at high power fields were found. Sensitivity and specificity of LE were 100% and 93.8 %, respectively. The positive predictive value was 79.3 %, while the negative predictive value was 100%. Time from collection to response was 20.1 ± 4.4 minutes. Sensitivity and specificity of FS were 83.3 % and 92.1 %, respectively. The positive and negative predictive values were 84.6 % and 97.1%. Time from sample collection response was 27.2 ± 6.9 minutes. LE showed a higher sensitivity and a slightly lower specificity and the same diagnostic accuracy of intraoperative FS. The faster turnaround time (about 20 minutes from receiving of sample by the laboratory), its ease of use and the low costs make this test a valuable alternative to frozen sections and is going to replace FS in our clinical practice


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 29 - 29
1 Aug 2018
Stockley I Partridge D Cooper R Townsend R
Full Access

No single test is 100% sensitive and specific for the diagnosis of prosthetic joint infection. Joint aspiration is currently the only preoperative investigation that can establish the identity of the infecting organism and its antibiotic susceptibilities. Frequently when attempting to aspirate a joint a ‘dry tap occurs as fluid cannot be aspirated. In this situation, normal saline may be injected into the joint and then reaspirated to provide fluid for culture. The aim of this study was to ascertain the diagnostic accuracy of culture of joint aspiratie with or without saline reaspiration in the event of a dry tap. A retrospective analysis of 580 hip and knee aspirations in patients deemed to have moderate-high risk of infection and ultimately proceeded to revision arthroplasty over 12 years at a large quaternary referral centre where pre operative aspiration is routine. Fluid was aspirated in 313 (54%) cases and dry taps in which saline injection reaspiration was performed occurred in 267 (46%) cases. Overall sensitivity and specificity of diagnostic aspiration were 84% (78–89%) and 85% (81–88%) respectively. Sensitivity and specificity of saline injection-reaspiration after dry tap were 87% (79–82%) and 79% (72–84%) compared to 81% (71–88%) and 90% (85–93%) for direct aspiration. Pre operative joint aspiration and culture is a sensitive and specific test for the confirmation of diagnosis in patients at a moderate to high risk of prosthetic joint infection. Culture of saline injection-reaspiration also provides accurate diagnostic information in the event of a dry tap. Both methods allow susceptibility testing of relevant organisms and are therefore able to guide peri-operative and cement instilled antibiotic therapy. Culture of pre operative joint aspirates provides sensitive and specific diagnostic information including antimicrobial susceptibility results. Saline injection-reaspiration is a useful additional technique in those patients in whom fluid cannot be aspirated


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 781 - 785
1 Jun 2005
Temmerman OPP Raijmakers PGHM Berkhof J Hoekstra OS Teule GJJ Heyligers IC

In this meta-analysis we included 32 English-language articles published between January 1975 and June 2004 on the diagnostic performance of plain radiography, subtraction arthrography, nuclear arthrography and bone scintigraphy in detecting aseptic loosening of the femoral component, using criteria based on the Cochrane systematic review of screening and diagnostic tests. The mean sensitivity and specificity were, respectively, 82% (95% confidence interval (CI) 76 to 87) and 81% (95% CI 73 to 87) for plain radiography and 85% (95% CI 75 to 91) and 83% (95% CI 75 to 89) for nuclear arthrography. Pooled sensitivity and specificity were, respectively, 86% (95% CI 74 to 93) and 85% (95% CI 77 to 91) for subtraction arthrography and 85% (95% CI 79 to 89) and 72% (95% CI 64 to 79) for bone scintigraphy. Although the diagnostic performance of the imaging techniques was not significantly different, plain radiography and bone scintigraphy are preferred for the assessment of a femoral component because of their efficacy and lower risk of patient morbidity


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 43 - 43
1 Jun 2017
Kiran M Shivarathre D Peter V
Full Access

There has been a significant decline in the use of metal-on-metal (MoM) bearings due to concerns regarding adverse reaction to metal debris (ARMD). The Medicines and Healthcare products Regulatory Agency (MHRA) recommends annual follow-up for life with blood Cobalt (Co) and Chromium (Cr) ion level measurement in all MoM THRs with femoral head size greater than or equal to 36mm. We present the serial ten year serum Co and Cr levels in a cohort of large head MoM THRs and analyse the utility of measuring serum ions levels annually. All patients who underwent unilateral large head MoM THR between January 2004 and December 2006 were included in this prospective study. Annual serum Co and Cr measurements were measured. Clinical case notes and radiographs were reviewed for failure, revision surgery and the occurrence of ARMD. Mann Whitney test was used to analyse changes in serum Co and Cr levels. Receiver Operating Characteristic (ROC) curve was plotted based on their sensitivity and specificity to detect ARMD. 256 patients were included. There was a significant increase in serum ion values in the first two years. After 7 years, there was no significant change in Co values(p=0.78) and there was a decline in Cr value after 9 years(p<0.001). With 7 µg/l as the cut-off value, the sensitivity and specificity of Co was 82.1% and 65.5% and of Cr was 53.5% and 91.3%. Annual follow-up of patients with MoM THR based on the MHRA guideline to obtain serum metal ion levels can cost about £9 million/year. Our study noted poor discriminatory ability for both Co and Cr values in the ROC curve. There is poor correlation between serum metal ion levels and the occurrence of ARMD on MARS MRI. Based on our results we find limited utility in doing ion levels after 7 years in asymptomatic patients


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 902 - 909
1 Aug 2019
Innmann MM Merle C Gotterbarm T Ewerbeck V Beaulé PE Grammatopoulos G

Aims. This study of patients with osteoarthritis (OA) of the hip aimed to: 1) characterize the contribution of the hip, spinopelvic complex, and lumbar spine when moving from the standing to the sitting position; 2) assess whether abnormal spinopelvic mobility is associated with worse symptoms; and 3) identify whether spinopelvic mobility can be predicted from static anatomical radiological parameters. Patients and Methods. A total of 122 patients with end-stage OA of the hip awaiting total hip arthroplasty (THA) were prospectively studied. Patient-reported outcome measures (PROMs; Oxford Hip Score, Oswestry Disability Index, and Veterans RAND 12-Item Health Survey Score) and clinical data were collected. Sagittal spinopelvic mobility was calculated as the change from the standing to sitting position using the lumbar lordosis angle (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA), and acetabular anteinclination (AI) from lateral radiographs. The interaction of the different parameters was assessed. PROMs were compared between patients with normal spinopelvic mobility (10° ≤ ∆PT ≤ 30°) or abnormal spinopelvic mobility (stiff: ∆PT < ± 10°; hypermobile: ∆PT > ± 30°). Multiple regression and receiver operating characteristic (ROC) curve analyses were used to test for possible predictors of spinopelvic mobility. Results. Standing to sitting, the hip flexed by a mean of 57° (. sd. 17°), the pelvis tilted backwards by a mean of 20° (. sd. 12°), and the lumbar spine flexed by a mean of 20° (. sd. 14°); strong correlations were detected. There was no difference in PROMs between patients in the different spinopelvic mobility groups. Maximum hip flexion, standing PT, and standing AI were independent predictors of spinopelvic mobility (R. 2. = 0.42). The combined thresholds for standing was PT ≥ 13° and hip flexion ≥ 88° in the clinical examination, and had 90% sensitivity and 63% specificity of predicting spinopelvic stiffness, while SS ≥ 42° had 84% sensitivity and 67% specificity of predicting spinopelvic hypermobility. Conclusion. The hip, on average, accounts for three-quarters of the standing-to-sitting movement, but there is great variation. Abnormal spinopelvic mobility cannot be screened with PROMs. However, clinical and standing radiological features can predict spinopelvic mobility with good enough accuracy, allowing them to be used as reliable screening tools. Cite this article: Bone Joint J 2019;101-B:902–909


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 42 - 42
1 Jun 2017
Della Valle C Fillingham Y Bohl D Kelly M Hall D Pourzal R Jacobs J
Full Access

Recently, corrosion at the head-neck junction in metal-on-polyethylene bearing total hip arthroplasty (THA) has been recognized as a cause of adverse local tissue reactions (ALTR). Serum metal levels have been advocated as a tool for the diagnosis of ALTR, however no prior studies have specifically examined their utility. The purpose of this study was to determine the optimal cut-off values for serum cobalt and chromium in diagnosing ALTR after metal-on-polyethylene bearing THA. We reviewed 447 consecutive patients with serum metal levels tested at our institution and identified 62 with a metal-on-polyethylene bearing who had axial imaging or underwent reoperation to confirm the presence or absence of ALTR. Receiver operating characteristic curves were produced to identify cut-off thresholds to optimize sensitivity and diagnostic test performance was characterized. 42 Of the 62 patients (66%) were positive for an ALTR. The best test for the diagnosis of ALTR was the serum cobalt level (area under the curve [AUC]=99%). A threshold cut-off of ≥ 1.0 ng/ml had a sensitivity of 100%, specificity of 90%, positive predictive value (PPV) of 96%, and negative predictive value (NPV) of 100%. Serum chromium levels were also diagnostic (AUC=87%). A threshold cut-off of ≥ 0.15 ng/ml had a sensitivity of 100%, specificity of 50%, PPV of 81%, and NPV of 100%. Finally, serum cobalt to chromium ratio was also helpful for diagnosis (AUC=90%). A threshold cut-off of 1.4 for the cobalt to chromium ratio offered a sensitivity of 93%, specificity of 70%, PPV of 87%, and NPV of 82%. Measurement of serum cobalt with a threshold value of 1.0 ng/ml in our experience is the best test for identifying the presence of ALTR in patients with a metal-on-polyethylene THA. Measurement of chromium and the ratio of cobalt to chromium are also of value


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 25 - 25
1 Oct 2019
Vail TP Shah R Bini S
Full Access

Background. 80% of health data is recorded as free text and not easily accessible for use in research and QI. Natural Language Processing (NLP) could be used as a method to abstract data easier than manual methods. Our objectives were to investigate whether NLP can be used to abstract structured clinical data from notes for total joint arthroplasty (TJA). Methods. Clinical and hospital notes were collected for every patient undergoing a primary TJA. Human annotators reviewed a random training sample(n=400) and test sample(n=600) of notes from 6 different surgeons and manually abstracted historical, physical exam, operative, and outcomes data to create a gold standard dataset. Historical data collected included pain information and the various treatments tried (medications, injections, physical therapy). Physical exam information collected included ROM and the presence of deformity. Operative information included the angle of tibial slope, angle of tibial and femoral cuts, and patellar tracking for TKAs and approach and repair of external rotators for THAs. In addition, information on implant brand/type/size, sutures, and drains were collected for all TJAs. Finally, the occurrence of complications was collected. We then trained and tested our NLP system to automatically collect the respective variables. Finally, we assessed our automated approach by comparing system-generated findings against the gold standard. Results. Overall, the NLP algorithm performed well at abstracting all variables in our random test dataset (accuracy=96.3%, sensitivity=95.2%, specificity=97.4%). It performed better at abstracting historical information (accuracy=97.0%), physical exam information (accuracy=98.8%), and information on complications (accuracy=96.8%) compared to operative information (accuracy=94.8%), but it performed well with a sensitivity and specificity >90.0% for all variables. Discussion. The NLP system achieved good performance on a subset of randomly selected notes with querying information about TJA patients. Automated algorithms like the one developed here can help orthopedic practices collect information for registries and help guide QI without increased time-burden. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 17 - 17
1 Nov 2015
Jeans E Syed A Mohammed A
Full Access

Introduction. Magnetic resonance arthrogram (MRA) is the investigation of choice in young adults with symptoms of femero acetabular impingement. The aim of the study is to assess the accuracy of MRA when correlated with surgical findings on hip arthroscopy. Materials and Method. Between June 2007 and January 2014, 136 patients had MRA followed by subsequent arthroscopy at our institution. The radiology information system was used to gather MRA data. All scans were reported by a consultant radiologist with a specialist interest in musculoskeletal radiology. Patient records were reviewed to gather surgical data. Assessment was made of labral injury, Camshaft (CAM) or Pincer lesion and degeneration of the cartilage. Results. Mean age at MRA was 34.5 years with a 2.5:1 female to male ratio. For labral pathology sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89, 100, 100 and 22% respectively. For CAM (62, 80, 79 and 64% respectively) and Pincer lesions (15, 84, 81 and 18% respectively). MRA was specific for picking up Grade 3/4 degenerate changes in the articular cartilage (92.2%) but was not as sensitive (60%), PPV 55 and NPV 94. Conclusion. These findings demonstrate that MRA is a sensitive and specific imaging modality for assessing the labrum and articular surface, but not as good for assessing CAM and Pincer lesions. This could be due to the static nature of the MRA or a lack of firm definition as to what constitutes a CAM or Pincer lesion leading to under reporting. This maybe better assessed with plane X ray or Computed tomography with 3 dimensional reconstruction. Further to this it would be interesting to combine the plane X ray and MRA finding and see if sensitivity and specificity was improved


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 320 - 325
1 Mar 2016
Gundtoft PH Pedersen AB Schønheyder HC Overgaard S

Aims. The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). Patients and Methods. We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005 and followed them until first-time revision, death, emigration or until 31 December 2012. Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records. We estimated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for PJI in the DHR alone and in the DHR when combined with microbiology databases. Results. In total, 1382 of the 37 826 primary THAs in the DHR were registered as having been revised for any cause once 26 patients with errors in registration had been excluded: 232 of these were for PJI. For this group, the sensitivity was 67%, specificity 95%, PPV 77%, and NPV 92%. Combining the data from the DHR with those from microbiology databases increased the sensitivity to 90% and also improved specificity (100%), PPV (98%) and NPV (98%). Conclusion. Only two thirds of revisions for PJI were captured in the DHR and only 77% of the PJI reported to the DHR could be confirmed to be infected. . Take home message: combining the data from the DHR with those from microbiology databases substantially improved the validity of the diagnosis of PJI and should enable future register-based studies. Cite this article: Bone Joint J 2016;98-B:320–5


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 32 - 32
1 May 2018
Kiran M Donnelly T Kapoor B Kumar G Peter V
Full Access

Introduction. Fluorodeoxuglucose(FDG) Positron Emission Tomography(PET) scan is used in the diagnosis of prosthetic joint infection, when the inflammatory markers and aspiration of the joint do not establish a definitive diagnosis. The aim of our study was to analyse the utility of FDG PET scan in decision making in these patients. Methods. We performed a prospective study of patients who underwent a FDG PET scan for suspected prosthetic hip infection, between September 2013 and July 2017. We analysed the results of aspiration, culture and sensitivity, histology of intra-operative samples and inflammatory markers. Our gold standard for diagnosis of infection was 3 or more positive cultures of the same organism. Diagnostic utility statistics for FDG PET were performed. Results. 55 revisions total hip replacements were included. The mean age of the patients was 67.5±4.85 years. The mean ESR, CRP and WCC were 19.83 mm/hr, 22.21 mg/l and 9.05×10. 9. /l respectively. The sensitivity and specificity for FDG PET were 93.75% and 35.89% respectively. The positive predictive value(PPV) was 37.5% and negative predictive value(NPV) was 93.33%. The accuracy of detecting an infection was 52.7%. The false positive rate was 62.5%. Discussion. FDG PET has a large number of false positive results and low specificity. If the inflammatory markers and aspiration do not establish infection, addition of FDG PET has limited accuracy in confirming the diagnosis of prosthetic joint infection. Conclusion. FDG PET may be useful for ruling out infection, but a positive result may not indicate the presence of infection


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 910 - 914
1 Aug 2019
Kiran M Donnelly TD Armstrong C Kapoor B Kumar G Peter V

Aims. Prosthetic joint infection (PJI) and aseptic loosening in total hip arthroplasty (THA) can present with pain and osteolysis. The Musculoskeletal Infection Society (MSIS) has provided criteria for the diagnosis of PJI. The aim of our study was to analyze the utility of F18-fluorodeoxyglucose (FDG) positron emission tomography (PET) CT scan in the preoperative diagnosis of septic loosening in THA, based on the current MSIS definition of prosthetic joint infection. Patients and Methods. A total of 130 painful unilateral cemented THAs with a mean follow-up of 5.17 years (. sd. 1.12) were included in this prospective study. The mean patient age was 67.5 years (. sd. 4.85). Preoperative evaluation with inflammatory markers, aspiration, and an F18 FDG PET scan were performed. Diagnostic utility tests were also performed, based on the MSIS criteria for PJI and three samples positive on culture alone. Results. The mean erythrocyte sedimentation rate, C-reactive protein, and white cell count were 47.83 mm/hr, 25.21 mg/l, and 11.05 × 10. 9. /l, respectively. The sensitivity, specificity, accuracy, negative predictive value, and false-positive rate of FDG PET compared with MSIS criteria were 94.87%, 38.46 %, 56.38%, 94.59 %, and 60.21%, respectively. The false-positive rate of FDG PET compared with culture alone was 77.4%. Conclusion. FDG PET has a definitive role in the preoperative evaluation of suspected PJI. This the first study to evaluate its utility based on MSIS criteria and compare it with microbiology results alone. However, FDG PET has a high false-positive rate. Therefore, we suggest that F18 FDG PET is useful in confirming the absence of infection, but if positive, may not be confirmatory of PJI. Cite this article: Bone Joint J 2019;101-B:910–914