Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 49 - 49
17 Apr 2023
Cooper G Kennedy M Jamal B Shields D
Full Access

Our objective was to conduct a systematic review and meta-analysis, comparing differences in clinical outcomes between either autologous or synthetic bone grafts in the operative management of tibial plateau fractures: a traumatic pattern of injury, associated with poor long-term functional prognosis. A structured search of MEDLINE, EMBASE, The Bone & Joint and CENTRAL databases from inception until 07/28/2021 was performed. Randomised, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture non-union or chondral defects were excluded. Outcome data was assessed using the Risk of Bias 2 (ROB2) framework and synthesised in random-effect meta-analysis. Preferred Reported Items for Systematic Review and Meta-Analysis guidance was followed throughout. Six comparable studies involving 352 patients were identified from 3,078 records. Following ROB2 assessment, five studies (337 patients) were eligible for meta-analysis. Within these studies, more complex tibia plateau fracture patterns (Schatzker IV-VI) were predominant. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference −0.45mm, p=0.25, 95% confidence interval (95%CI): −1.21-0.31mm, I. 2. =0%) and long-term (>6 months, standard mean difference −0.56, p=0.09, 95%CI: −1.20-0.08, I. 2. =73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, defect site pain, occurrence of surgical site infections, secondary surgery, perioperative blood loss, and duration of surgery. Blood loss was lower (90.08ml, p<0.001, 95%CI: 41.49-138.67ml, I. 2. =0%) and surgery was shorter (16.17minutes, p=0.04, 95%CI: 0.39-31.94minutes, I. 2. =63%) in synthetic treatment groups. All other secondary measures were statistically comparable. Our findings supersede previous literature, demonstrating that synthetic bone grafts are non-inferior to autologous bone grafts, despite their perceived disadvantages (e.g. being biologically inert). In conclusion, surgeons should consider synthetic bone grafts when optimising peri-operative patient morbidity, particularly in complex tibial plateau fractures, where this work is most applicable


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 102 - 102
1 Mar 2021
Tazawa R Minehara H Matsuura T Kawamura T Uchida K Inoue G Saito W Takaso M
Full Access

Segmental bone transport (SBT) using an external fixator is currently a standard treatment for large-diameter bone defects at the donor site with low morbidity. However, long-term application of the device is needed for bone healing. In addition, patients who received SBT treatment sometimes fail to show bone repair and union at the docking site, and require secondary surgery. The objective of this study was to investigate whether a single injection of recombinant human bone morphogenetic protein 2 (rhBMP-2)-loaded artificial collagen-like peptide gel (rhBMP-2/ACG) accelerates consolidation and bone union at the docking site in a mouse SBT model. Six-month-old C57BL/6J mice were reconstructed by SBT with external fixator that has transport unit, and a 2.0-mm bone defect was created in the right femur. Mice were divided randomly into four treatment groups with eight mice in each group, Group CONT (immobile control), Group 0.2mm/d, Group 1.0mm/d, and Group BMP-2. Mice in Group 0.2mm/d and 1.0mm/d, bone segment was moved 0.2 mm per day for 10 days and 1.0 mm per day for 2 days, respectively. Mice in Group BMP-2 received an injection of 2.0 μg of rhBMP-2 dissolved in ACG into the bone defect site immediately after the defect-creating surgery and the bone segment was moved 1.0 mm/day for 2 days. All animals were sacrificed at eight weeks after surgery. Consolidation at bone defect site and bone union at docking site were evaluated radiologically and histologically. At the bone defect site, seven of eight mice in Group 0.2mm/d and two of eight mice in Group 1.0mm/d showed bone union. In contrast, all mice in Group CONT showed non-union at the bone defect site. At the docking site, four of eight mice in Group 0.2 mm/d and three of eight mice in Group 1.0 mm/d showed non-union. Meanwhile, all mice in Group BMP-2 showed bone union at the bone defect and docking sites. Bone volume and bone mineral content were significantly higher in Group 0.2mm/d and Group BMP-2 than in Group CONT. HE staining of tissue from Group 0.2mm/d and Group BMP-2 showed large amounts of longitudinal trabecular bone and regenerative new bone at eight weeks after surgery at the bone defect site. Meanwhile, in Group CONT and Group 1.0mm/d, maturation of regenerative bone at the bone defect site was poor. Differences between groups were analyzed using one-way ANOVA and a subsequent Bonferroni's post-hoc comparisons test. P < 0.05 was considered significant. rhBMP-2/ACG combined with SBT may be effective for enhancing bone healing in large bone defects without the need for secondary procedures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 62 - 62
1 Aug 2013
Soon V Chirputkar K Gaheer R Corrigan N Picard F
Full Access

Component malrotation in total knee arthroplasty (TKA) is a reason for early failure and revision. Assessment of possible component malrotation using computed tomography (CT) might be useful when other differentials have been excluded. The aims of our study were to determine the proportion of symptomatic patients with component malrotation on CT, and review the subsequent management of such patients. A retrospective review of case notes was performed locally for all patients who had a CT scan for a painful TKA. Measurements of the femoral and tibial component rotations were done according to the standard Berger protocol, giving net degrees of either external rotation (ER) or internal rotation (IR). Any subsequent surgery was noted, and patients were followed up as per local practice. Between 2007 and April 2012, 69 knees in 68 patients had CT scans. There were 25 males and 43 females, and mean age at primary surgery was 65.03 years. The mean femoral component rotation for all knees was 0.1° ER (range 7.0° ER – 6.7° IR), and the mean tibial component rotation for all knees was 19.1° IR (6.6° ER – 37.0° IR). No statistically significant difference was found comparing the mean femoral and tibial component rotations between patients with and without further surgery. Further surgery was performed on 39 (56.5%) knees. Overall, there were ten cases (14.5%) of isolated femoral malrotation, 26 tibial malrotation (37.7%), and two cases (2.9%) had malrotation of both components. Out of these 38 cases, secondary surgery was performed in 22 knees (57.9%), of which a satisfactory outcome was achieved in fifteen cases (68.1%). It is impossible to establish component malrotation as the only cause of pain following TKA, however, our study does show that the Berger protocol has its uses when other causes have been excluded


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 44 - 44
1 Aug 2012
Drew T Gibson J Burke J
Full Access

Growth rods are currently used in young children to hold a scoliosis until the spine has reached a mature length. Only partial deformity correction is achieved upon implantation, and secondary surgeries are required at 6-12 month intervals to lengthen the holding rod as the child grows. This process contains, rather than corrects, the deformity and spinal fusion is required at maturity. This treatment has a significant negative impact on the bio-psychosocial development of the child. Aim. To design a device that would provide a single minimally invasive, non-fusion, surgical solution that permits controlled spinal movement and delivers three dimensional spinal correction. Method. Physical and CAD implant models were developed to predict curve and rotational correction during growth. This allowed use of static structural finite element analysis to identify magnitudes and areas of maximum stress to direct the design of prototype implants. These were mechanically tested for strength, fatigue and wear to meet current Industrial standards. Results. A dynamic hinged construct, was produced. This consisted of carbon nitride coated CoCrMo components assembled in a modular fashion. Five implants were tested under static load to simulate spinal flexion establishing a mean average yield point at a bending moment of 20.8 Nm (SD 2.5 Nm). Six samples were tested for fatigue endurance to 10 million cycles. Two implants were loaded with a 10 Nm maximum bending moment without fracture. Two samples were loaded at 14 Nm with one surviving and one fracturing at 569,048 cycles. Samples loaded at 16 Nm and 17 Nm both fractured at 3,460,359 and 237,613 cycles respectively. Two implants were tested for wear, the first fractured after 290,000 cycles. A second modified implant was tested to ten million cycles and a mean wear rate of 2.03 mg per million cycles was determined during this period. Exposure of the CoCrMo implant substrate was first observed at two million cycles. Conclusion. The device met all mechanical test criteria necessary for CE marking and allowed progression to implant testing in an ovine model


Bone & Joint 360
Vol. 8, Issue 4 | Pages 46 - 47
1 Aug 2019
Das A