Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 124 - 124
1 Mar 2012
David L Back D Hanna S Cannon S Briggs T
Full Access

Introduction. We discuss the use of the SMILES (Stanmore Modular Individualised Lower Extremity System) in salvage revision knee surgery and review the medium-long term results of 42 cases. Methods. This is a prospective, single-centre study. The SMILES prosthesis is a custom-made implant incorporating a rotating hinge knee joint. 42 prostheses were used in 40 patients as salvage revision procedures between September 1991 and September 1999. Patients undergoing surgery for tumours were excluded. The minimum follow-up was seven years with a mean follow-up of ten years and six months. Patients were independently assessed using the Knee Society Rating Score. The age of the patients ranged from 36-85 years (mean 68 years and 6 months). 23 of the patients were male. The original pathology was osteoarthritis in 32 patients and rheumatoid arthritis in 8 patients. The number of previous arthroplasties ranged from 1-4. The main indications for a SMILES prosthesis were aseptic loosening, periprosthetic fracture and infection in the presence of bone loss and ligamentous laxity. Results. There was a highly statistically significant improvement in overall Knee Society scores from a mean of 26 pre-op to 72 post-op. The mean knee score improved from 26 pre-op to 68 post-op while the mean function score improved from 27 to 75. The average range of motion was 60 degrees pre-op and 90 degrees post-op. Complications included: failure to eradicate infection in two patients, with one patient needing amputation; infection of the prosthesis leading to revision in one, and failure of the tibial component needing revision. Conclusion. The SMILES has produced satisfactory results in the medium to long term, offering an alternative to amputation in some cases. The cost compares favourably with other designs and the use is increasing in frequency


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_17 | Pages 10 - 10
1 Nov 2017
Sidharthan S Lokikere N Saraogi A Nagai H Wynn-Jones H Board T Shah N Porter M Kay P
Full Access

Background. One of the major concerns of hinge knees have been reported in literature is mechanical failure. Failure in the form of component fracture (2–10%) and hinge dislocation/ failure are worrisome. In addition, higher risk of aseptic loosening with hinge knee prosthesis has been attributed to stress transfer at bone cement interface. Methods. Retrospective review of clinical and radiological results of 71 consecutive patients operated at single centre using Smiles hinge knee (Stanmore implants) between 2010 and 2014. Data was collected till the latest follow up. Mechanical failure due to any reason was considered as primary end point. Radiological evidence of aseptic loosening was considered to be one of the surrogate end points. Results. Mean age at revision knee was 65.4 years (range 42 – 84). The number of previous revisions ranged from 1 – 4. Most common indications for revision were infection (n=26) and instability (n=26). Majority of patients had rotating hinge knee (n=66). Average follow-up was 31 months (range 3 – 72). Four patients died during follow-up due to medical reasons. There were no mechanical failures of implants apart from backing out of axle due to failure of circlip in 1 patient. Asymptomatic aseptic loosening of implant on femoral side was noted in 1 patient; however, there were no peri-prosthetic fractures in this series. Three patients had re-revision for infection and one for extensor mechanism subluxation. Conclusion. To our knowledge, this is the largest series till date reporting on mechanical outcomes of hinged knee implants for complex revisions. Clip failure is of concern; however there have been no other mechanical failures. Early results are encouraging, with no symptomatic aseptic loosening of implants to report


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 131 - 131
1 Jun 2012
Macmull S Bartlett W Miles J Blunn G Pollock R Carrington R Skinner J Cannon S Briggs T
Full Access

Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion. We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The “SMILES spacer” was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24–70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients. In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 7 - 7
1 Feb 2013
Sewell M Carrington R Pollock R Skinner J Cannon S Briggs T
Full Access

Patients with skeletal dysplasia are prone to developing advanced degenerative knee disease requiring total knee replacement (TKR) at a younger age than the general population. TKR in this unique group of patients is a technically demanding procedure due to the bone deformity, flexion contracture, generalised hypotonia and ligamentous laxity. We set out to retrospectively review the outcome of 11 TKR's performed in eight patients with skeletal dysplasia at our institution using the SMILES custom-made rotating-hinge total knee system. There were 3 males and 5 females with mean age 57 years (range, 41–79 years), mean height 138 cm (range, 122–155 cm) and mean weight 56 kg (range, 40–102 kg). Preoperative diagnoses included achondroplasia, spondyloepiphyseal dysplasia, pseudoachondroplasia, multiple epiphyseal dysplasia, morquio syndrome, diastrophic dysplasia and Larson's Syndrome. Patients were followed clinically and radiographically for a mean of 7 years (range, 3–11.5 years). Knee pain and function improved in all 11 joints. Mean Knee Society clinical and function scores improved from 24 (range, 14–36) and 20 points (range, 5–40) preoperatively to 68 (range, 28–80) and 50 points (range, 22–74) respectively at final follow-up. Four complications were recorded (36%), including a patellar fracture following a fall, a tibial periprosthetic fracture, persistent anterior knee pain and a femoral component revision for aseptic loosening. Our results suggest that custom rotating-hinge TKR in patients with skeletal dysplasia is effective at relieving pain, optimising movement and improving function. It compensates for bony deformity and ligament deficiency and reduces the need for corrective osteotomy. Patellofemoral joint complications are frequent and functional outcome is worse than primary TKR in the general population. Submission endorsed by Mr Peter Calder, Consultant Orthopaedic Surgeon and Society member