Advertisement for orthosearch.org.uk
Results 1 - 20 of 55
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 296 - 296
1 Sep 2012
Cantin O Cantin O Chouteau J Henry J Viste A Fessy M Moyen B
Full Access

Introduction. There is a challenge to detect partial tear of the ACL, the number of bundle injured and the proportion of fibers torn. The MRI was shown efficient to individualize the two anteromedial (AM) and posterolateral (PL) bundles of the ACL. The purpose of this study was to assess the ability of the MRI to detect partial tears of the ACL on axial views to display the AM and PL bundles. Materials and methods. This retrospective study included 48 patients (19 partial tears of the ACL, 16 complete rupture of the ACL and 13 normal knee) who underwent both arthroscopy and MRI examinations of the knee. The conventional MRI protocol included one sagittal T1- weighted sequence and 3 proton-density fat sat. The images from MRI were analysis by a radiologist specialized in musculoskeletal imaging who was blinding to the arthroscopic findings. The criteria for the analysis of MRI were divided into primary (those involving the ACL himself) and secondary signs (associated abnormalities). The primary signs included the horizontalisation of the ACL (ACL axis), the global ACL signal intensity and the signal intensity of each AM and PL bundle. The secondary signs included bone bruise, osteochondral impaction, popliteus muscle injury, medial collateral ligament injury and joint effusion. The ACL was classified as normal, partially or totally torn. The rupture of the AM and PL bundle was specified. Results. In our study, MRI was found to have a 75% sensitivity and a 73% specificity for the diagnosis of partial tears of the ACL. The sensitivity to detect AM bundle lesion was 88% but the specificity was 50%. The lack of horizontalisation of the ACL was a very good sign, for partial tears of the ACL, with a sensitivity of 84% and a specificity of 81% (p<0.05). Regarding the secondary signs, there was no significant difference to distinguish partial and complete tear. However, we found that there was a greater probability to find a partial tear of the ACL with the lack of joint effusion, bone bruise and medial collateral ligament injury. Quantifying the proportion of injured fibers was unsuccessful and was found as a failure of the MRI. Conclusions. MRI exhibited lower sensitivity and specificity for partial tear than for complete rupture of the ACL. However 3 important arguments can guide us: the lack of horizontalisation of the ACL, a continuous ACL signal, the display of one of two bundles on the axial view


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 204 - 205
1 Mar 2001
Thomas RH Holt MD James SH White PG

The imaging techniques available to aid the diagnosis of ruptures of tendo Achillis, the rotator cuff and the tendon of tibialis posterior in rheumatoid patients are well described. However, ruptures of tendon or muscle at other sites are uncommon and may be overlooked. Diagnosis is often made by localised tenderness, swelling and a lack of active movement associated with a palpable defect. Clinical examination may be inconclusive and can be aided by imaging studies. We report two cases in which ruptures of a tendon were suspected, and ultrasound imaging demonstrated the palpable defect to be a cleavage plane in the subcutaneous fat – a ‘fat fracture’


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 562 - 567
1 Jul 1996
van Dijk CN Bossuyt PMM Marti RK

After a severe ankle sprain the incidence of residual complaints, particularly on the medial side of the joint, is high. We studied a consecutive series of 30 patients who had operative repair of acute ruptures of lateral ligaments. During operation, arthroscopy revealed a fresh injury to the articular cartilage in 20 ankles, in 19 at the tip and/or anterior distal part of the medial malleolus as well as on the opposite medial facet of the talus. In six patients, a loose piece of articular cartilage was found. We conclude that in patients with a rupture of one or more of the lateral ankle ligaments after an inversion injury, an impingement occurs between the medial malleolus and the medial facet of the talus. Patients with a lesion of the lateral ankle ligament caused by a high-velocity injury (a faulty landing during jumping or running) had a higher incidence of macroscopic cartilage damage (p < 0.01), medially-located pressure pain (p = 0.06) and medially-located complaints at one-year follow-up (p = 0.02) than those with a low-velocity injury (a stumble)


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 525 - 530
1 May 2003
Pijnenburg ACM Bogaard K Krips R Marti RK Bossuyt PMM van Dijk CN

Consecutive patients with a confirmed rupture of at least one of the lateral ligaments of the ankle were randomly assigned to receive either operative or functional treatment. They were evaluated at a median of 8 years (6 to 11). In total, 370 patients were included. Follow-up was available for 317 (86%). Fewer patients allocated to operative treatment reported residual pain compared with those who had been allocated to functional treatment (16% versus 25%, RR 0.64, CI 041 to 1.0). Fewer surgically-treated patients reported symptoms of giving way (20% versus 32%, RR 0.62, CI 0.42 to 0.92) and recurrent sprains (22% versus 34%, RR 0.66, CI 0.45 to 0.94). The anterior drawer test was less frequently positive in surgically-treated patients (30% versus 54%, RR 0.54, CI 0.41 to 0.72). The median Povacz score was significantly higher in the operative group (26 versus 22, p < 0.001). Compared with functional treatment, operative treatment gives a better long-term outcome in terms of residual pain, recurrent sprains and stability


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_7 | Pages 7 - 7
1 May 2021
Al-Hourani K Sri K Shepperd J Zhang Y Hull B Murray IR Duckworth AD Keating JF White T
Full Access

Correct femoral tunnel position in anterior cruciate ligament reconstruction (ACLR) is critical in obtaining good clinical outcomes. We aimed to delineate whether any difference exists between the anteromedial (AM) and trans-tibial (TT) portal femoral tunnel placement techniques on the primary outcome of ACLR graft rupture. Adult patients (>18year old) who underwent primary ACLR between January 2011 – January 2018 were identified and divided based on portal technique (AM v TT). The primary outcome measure was graft rupture. Univariate analysis was used to delineate association between independent variables and outcome. Binary logistic regression was utilised to delineate odds ratios of significant variables. 473 patients were analysed. Median age at surgery was 27 years old (range 18–70). A total of 152/473, (32.1%) patients were AM group compared to 321/473 (67.9%) TT. Twenty-five patients (25/473, 5.3%) sustained graft rupture. Median time to graft rupture was 12 months (IQR 9). A higher odds for graft rupture was associated with the AM group, which trended towards significance (OR 2.03; 95% CI 0.90 – 4.56, p=0.081). Older age at time of surgery was associated with a lower odds of rupture (OR 0.92, 95% CI 0.86 – 0.98, p=0.014). There is no statistically significant difference in ACLR graft rupture rates when comparing anteromedial and trans-tibial portal technique for femoral tunnel placement. There was a trend towards higher rupture rates in the anteromedial portal group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 14 - 14
1 Dec 2023
Hems A Hopper G An J Lahsika M Giurazza G Vieira TD Sonnery-Cottet B
Full Access

Introduction. It has been contentious whether an anatomic double-bundle technique for anterior cruciate ligament reconstruction (ACLR)is superior to that of a single-bundle technique. It has been hypothesized in the literature that the double-bundle technique could provide function closer to that of the anatomical knee joint. The purpose of this study was to compare the long-term clinical outcomes after single-bundle ACLR versus double-bundle ACLR. We hypothesized that the double-bundle technique would not be superior to the single-bundle technique. Methods. A retrospective, non-randomized, matched-paired comparative study was performed. Patients undergoing primary anterior cruciate ligament reconstruction, using either a double-bundle or single-bundle technique, between 2003 and 2008 were included and matched 1:1. Matching included age, sex, BMI, time from injury to surgery, side of injury and type of sport. Patients who underwent revision procedures, multiligament reconstruction or other ACLR techniques were excluded. Patients were subsequently followed up, noting occurrence of graft rupture and any other complications. Results. A total of 1377 ACLRs were performed during the study period. Seven hundred and fifty-six patients were excluded, leaving 396patients to be included in the matching (198 matched pairs). Mean follow-up time was 176.7 +/− 7.7 months (range, 166–211 months). Overall, 40 patients (10.1%) suffered from a graft rupture which consisted of 22 patients (11.1%) in the single-bundle group and 18patients (9.1%) in the double-bundle group. A multivariate analysis was performed using the Cox model and demonstrated that graft failure had no significant association with the surgical technique (hazard ratio (HR), 0.857(0.457;1.609), p=0.6313). (Figure 1) Five patients (2.5%) in the single-bundle group and 7 patients (3.5%) in the double-bundle group underwent secondary surgery for cyclops syndrome(p=0.5637). Three patients (1.5%) in the single-bundle group and 2 patients (1.0%) in the double-bundle group underwent arthrolysis(p=0.6547). Seven patients (3.5%) in the single-bundle group underwent secondary meniscectomy compared to 6 patients (3.0%) in the double-bundle group (p=0.7630). Conclusion. Double-bundle ACLR is not superior to single-bundle ACLR at long-term follow up. Therefore, orthopaedic surgeons do not need to use a double-bundle technique when performing ACL reconstruction. For any figures or tables, please contact authors directly


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1256 - 1265
1 Nov 2022
Keene DJ Alsousou J Harrison P O’Connor HM Wagland S Dutton SJ Hulley P Lamb SE Willett K

Aims

To determine whether platelet-rich plasma (PRP) injection improves outcomes two years after acute Achilles tendon rupture.

Methods

A randomized multicentre two-arm parallel-group, participant- and assessor-blinded superiority trial was undertaken. Recruitment commenced on 28 July 2015 and two-year follow-up was completed in 21 October 2019. Participants were 230 adults aged 18 years and over, with acute Achilles tendon rupture managed with non-surgical treatment from 19 UK hospitals. Exclusions were insertion or musculotendinous junction injuries, major leg injury or deformity, diabetes, platelet or haematological disorder, medication with systemic corticosteroids, anticoagulation therapy treatment, and other contraindicating conditions. Participants were randomized via a central online system 1:1 to PRP or placebo injection. The main outcome measure was Achilles Tendon Rupture Score (ATRS) at two years via postal questionnaire. Other outcomes were pain, recovery goal attainment, and quality of life. Analysis was by intention-to-treat.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1607 - 1611
1 Dec 2009
Stufkens SAS Knupp M Lampert C van Dijk CN Hintermann B

We have compared the results at a mean follow-up of 13 years (11 to 14) of two groups of supination-external rotation type-4 fractures of the ankle, in one of which there was a fracture of the medial malleolus and in the other the medial deltoid ligament had been partially or completely ruptured. Of 66 patients treated operatively between 1993 and 1997, 36 were available for follow-up. Arthroscopy had been performed in all patients pre-operatively to assess the extent of the intra-articular lesions. The American Orthopaedic Foot and Ankle Society hind-foot score was used for clinical evaluation and showed a significant difference in both the total and the functional scores (p < 0.05), but not in those for pain or alignment, in favour of the group with a damaged deltoid ligament (p < 0.05). The only significant difference between the groups on the short-form 36 quality-of-life score was for bodily pain, again in favour of the group with a damaged deltoid ligament. There was no significant difference between the groups in the subjective visual analogue scores or in the modified Kannus radiological score. Arthroscopically, there was a significant difference with an increased risk of loose bodies in the group with an intact deltoid ligament (p < 0.005), although there was no significant increased risk of deep cartilage lesions in the two groups. At a mean follow-up of 13 years after operative treatment of a supination-external rotation type-4 ankle fracture patients with partial or complete rupture of the medial deltoid ligament tended to have a better result than those with a medial malleolar fracture


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 23 - 23
1 May 2014
Evans J Guyver P Smith C
Full Access

We present (with intra-operative imaging) 4 patients who sustained Pectoralis major ruptures on the same piece of equipment of the “Tarzan” assault course at the Commando Training Centre, Royal Marines (CTCRM). Recruits jump at running pace, carrying 21 pounds of equipment and a weapon (8 pounds) across a 6ft gap onto a vertical cargo-net. The recruits punch horizontally through the net, before adducting their arm to catch themselves, and all weight, on their axilla. All patients presented with immediate pain and reduced function. 2 had ruptures demonstrated on MRI, 1 on USS and one via clinical examination. All 4 patients were found, at operation, to have sustained type IIIE injuries. All patients underwent Pectoralis major repair using a uni-cortical button fixation and had an uneventful immediate post operative course. Patient 1 left Royal Marines training after the injury (out of choice, not because of failure to rehabilitate). All other patients are under active rehabilitation hoping to return to training. Review of 10 years of records at CTCRM reveal no documented Pectoralis major rupture prior to our first case in October 2013. There has been no change to the obstacle or technique used and all patients deny the use of steroids


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_1 | Pages 9 - 9
1 Jan 2019
Wickramasinghe N Maempel J Clement N Duckworth A Keating J
Full Access

Limited long term data exists comparing operatively and non-operatively treated Achilles tendon ruptures. A previous randomised controlled trial comparing early outcomes showed a short term advantage for surgery, but there are no long term prospective randomised comparisons. Our aim was to determine whether surgery conferred long term benefits in terms of patient reported outcomes or re-rupture. 64 patients (80%) were followed up with postal questionnaires. Patients were asked to complete the Short Musculoskeletal Function Assessment (SMFA), Achilles Tendon Total Rupture Score (ATRS) and EQ-5D questionnaires, and to report re-ruptures. 32 patients were treated non-operatively and 32 operatively; 59 completed the SMFA and 64 the ATRS and EQ-5D assessments. There was no significant difference in SMFA score (median 1.09, IQR 4.89 in the cast group versus 2.17 and 7.07 in the operative group; p=0.347), ATRS (median 96, IQR 18 versus 93 and 15; p=0.509), EQ-5D Index (median 1.0, IQR 0.163 versus 1.0 and 0.257; p=0.327) and EQ-5D Visual Analogue Score (median score 85, IQR 15 versus 85 and 24; p=0.650). There were 2 re-ruptures in the operative group and 4 in the non-operative group (p=0.067). This is the first prospective, randomised, long term report comparing operative and non-operative management. At follow up between 13–17 years after injury, patients reported good function and health related quality of life. There was no significant difference in re-rupture rate between the treatment groups


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 295 - 295
1 Sep 2012
Correa E Font J Mir X Isart A Cáceres E
Full Access

INTRODUCTION. The TFCC injuries are usually diagnosed by a coronal MRI. We have described the Float image for the diagnosis of peripheral injuries of the TFCC. In a sagital image parallel to the ulnar diaphysis and placed lateral to the ulnar fovea, we can observe the radiocubital dorsal and volar ligaments of the TFCC. A distance of more than 4mm between the dorsal edge of the meniscus and the joint capsule suggests the presence of TFCC peripheral rupture. METHOD. 51 pacients were selected from all the patients who underwent wrist arthroscopy between 2006–2009. Inclusion criteria: MRI at our hospital, arthroscopy at our hospital, no presence of radial fracture. We assessed the correlation between the presence of the Float image and a TFCC injury confirmed by arthroscopy. RESULTS. The Float image for the diagnosis of peripheral TFCC injuries has a sensibility of 0.929 [0.774 to 0.98] and a specificity of 0,857 [0.654 to 0.95]. PPV: 0.897 [0.736 to 0.964] and NPV: 0.9 [0.699 to 0.972]. CONCLUSIONS. The Float MRI is a high sensibility and specificity method for the diagnosis of peripheral TFCC. The coronal MRI is useful for diagnosing central ruptures but has less sensibility for the peripheral injuries


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 463 - 463
1 Sep 2012
Gaskin J Forde-Gaskin D Ajekigbe L
Full Access

Introduction. Flexor tendon injuries are quite common injuries. They can result in persisting functional deficit if not repaired and appropriately rehabilitated. We look at flexor tendon injuries over a period of 1 year and re-audited three years later. Method. We audited all flexor tendon injuries that were treated at our institution and repeated the same audit three years after. We looked at various aspects of the injuries including the site injured, the zone of injury, other structures injured, the type of repair and material used as well as the rehabilitation regime. Results. The initial audit had 43 patients, 83% male, 55% unemployed with 85 tendon injuries. There were 35% zone 5 injuries with 34% repaired in <24hrs with modified Kessler core 3.0 prolene sutures and 6.0 prolene peripheral sutures. The rupture rate was 3% and the infection rate was 1%. A re-audited was done 3 years later, over the same time period, there were 69 patients, 83% male, 1% unemployed with 102 tendon injuries. There were 40% zone 2 injuries with 43% repaired with modified Kessler core 3.0 prolene sutures and 6.0 prolene peripheral sutures. Rupture rate was 9% and infection rate was 1% and 10% median nerve injury. All injuries were rehabilitated using the Belfast regime. Discussion and Conclusion. Flexor tendon injuries are frequently occurring injuries and require a careful and meticulous attention to detail, relative to repair, to achieve the most effective recovery. We found that over a three year period that the zone of injury in the cohort of patients in our region had changed, as well as the unemployment rate. Other parameters were generally similar. We conclude that treatment of flexor tendon injuries should undergo the audit cycle to ensure that best practice is achieved and maintained


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 466 - 466
1 Sep 2012
Ditsios K Kapoukranidou D Boutsiadis A Chatzisotiriou A Albani M Christodoulou A
Full Access

Purpose of this study is to create an experimental model of electrophysologic evaluation of the supraspinatus muscle on rats, after traumatic rupture of its tendon. The population of this study consisted of 10 male Sprague Dawley rats weighting 300–400g. Under general anaesthesia we proceeded with traumatic rupture of the supraspinatus tendon and exposure of the muscle. The scapula was immobilized, and the supraspinatus tendon was attached to a force transducer using a 3–0 silk thread. A dissection was performed in order to identify the suprascapular nerve, which was then stimulated with a silver electrode. Stimulations were produced by a stimulator (Digitimer Stimulator DS9A) and were controlled by a programmer (Digitimer D4030). Fiber length was adjusted until a single stimulus pulse elicited maximum force during a twitch under isometric conditions. Rectangular pulses of 0.5 ms duration were applied to elicit twitch contractions. During the recordings, muscles were rinsed with Krebs solution of approximately 37 8C (pH 7.2–7.4) and aerated with a mixture of 95% O2 and 5% CO2. The output from the transducer was amplified and recorded on a digital interface (CED). The following parameters were measured at room temperature (20–21 8C): single twitch tension; time to peak; half relaxation time; tetanic tensions at 10, 20, 40, 80 and 100 Hz; and fatigue index, which was evaluated using a protocol of low frequency (40 Hz) tetanic contraction, during 250 ms in a cycle of 1 s, for a total time of 180 s. The fatigue index value was then calculated by the formula [fatigue index=(initial tetanic tension − end tetanic tension) ∗ 100/(initial tetanic tension)]. In the end, the transducer was calibrated with standard weights and tensions were converted to grams. The mean single twitch was 8.2, the time to peak 0.034 msec and the half relaxation time 0.028 msec. The strength of titanic muscle contractures was 5.7 msec at 10Hz and 17.7 at 100Hz. Finally, the fatigue index was calculated at 48.4. We believe that electrophysiologic evaluation of the supraspinatus muscle in rats will help us understanding the pathology of muscle atrophy after rotator cuff tears and possibly the functional restoration after cuff repair


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 89 - 89
1 Sep 2012
Ackermann P Schizas N Bring D Li J Andersson T Fahlgren A Aspenberg P
Full Access

Introduction. Traumatized musculoskeletal tissue often exhibits prolonged time to healing, mostly due to low blood flow and innervation. Intermittent Pneumatic Compression (IPC) increases blood flow and decreases thromboembolic event after orthopedic surgery,[1] however little is known about healing effects.[2] We hypothesized that IPC could stimulate tissue repair: 1.) blood flow 2.) nerve ingrowth 3.) tissue proliferation and during immobilisation enhance 4.) biomechanical tissue properties. Methods. Study 1: In 104 male Sprague Dawley (SD) rats the right Achilles tendon was ruptured and the animals freely mobilized. Half the group received daily IPC-treatment, using a pump and cuff over the hindpaw that inflates/deflates cyclicly, 0–55mmHg (Biopress SystemTM, Flexcell Int.), and the other half received sham-treatment. Healing was assessed at 1,3,6 weeks by perfusion-analysis with laser doppler scanner (Perimed, Sweden), histology and biomechanical testing. Study 2: 48 male SD-rats were ruptured as above. Three groups of each 16 rats were either mobilized, immobilized or immobilized with IPC treatment. Immobilization was performed by plaster cast. Healing was assessed at 2 weeks with histology and biomechanical testing. Results. Study 1: At 3 and 6 weeks reperfusion increased by 21% and 23% (p< 0.05) after IPC-treatment, strengthened by the observation of elevated numbers of blood vessels and nerves. Fibroblast density was at all time points significantly increased in the IPC group. At three and six weeks the IPC treated tendons displayed an increased tissue organization confirmed by higher collagen I/III ratio in the IPC group. No differences (p = 0.10) were found regarding biomechanical strength. Study 2: Compared to mobilization, immobilization caused a downregulation (p<0.05) of all biomechanical and histological parameters, eg. maximum force decreased 80% and collagen III occurrence by 83%. However when immobilization was combined with IPC biomechanical and histological healing increased significantly compared to pure immobilization, eg. maximum force increased 63% and collagen III occurrence by 150%. Conclusion. This study demonstrated that IPC treatment can counteract biomechanical and morphological deficits caused by immobilization by enhancing proliferative soft tissue repair. Thus, IPC promotes tissue repair by stimulating tissue perfusion and nerve ingrowth as well as accelerating both fibroblast proliferation and collagen organization


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1033 - 1039
1 Jun 2021
Coughlin T Norrish AR Scammell BE Matthews PA Nightingale J Ollivere BJ

Aims

Following cast removal for nonoperatively treated distal radius fractures, rehabilitation facilitated by advice leaflet and advice video were compared to a course of face-to-face therapy.

Methods

Adults with an isolated, nonoperatively treated distal radius fracture were included at six weeks post-cast removal. Participants were randomized to delivery of rehabilitation interventions in one of three ways: an advice leaflet; an advice video; or face-to-face therapy session(s). The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at six weeks post intervention and secondary outcome measures included DASH at one year, DASH work subscale, grip strength, and range of motion at six weeks and one year.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1629 - 1633
1 Dec 2006
Jungbluth P Frangen TM Arens S Muhr G Kälicke T

The Essex-Lopresti injury is rare. It consists of fracture of the head of the radius, rupture of the interosseous membrane and disruption of the distal radioulnar joint. The injury is often missed because attention is directed towards the fracture of the head of the radius. We present a series of 12 patients with a mean age of 44.9 years (26 to 54), 11 of whom were treated surgically at a mean of 4.6 months (1 to 16) after injury and the other after 18 years. They were followed up for a mean of 29.2 months (2 to 69). Ten patients had additional injuries to the forearm or wrist, which made diagnosis more difficult. Replacement of the head of the radius was carried out in ten patients and the Sauve-Kapandji procedure in three. Patients were assessed using standard outcome scores. The mean post-operative Disabilities of the Arm, Shoulder and Hand score was 55 (37 to 83), the mean Morrey Elbow Performance score was 72.2 (39 to 92) and the mean Mayo wrist score was 61.3 (35 to 80). The mean grip strength was 68.5% (39.6% to 91.3%) of the unaffected wrist. Most of the patients (10 of 12) were satisfied with their operation and in 11 the pain was relieved. When treating the chronic Essex-Lopresti injury, we recommend accurate realignment of the radius and ulna and replacement of the head of the radius. If this fails a Sauve-Kapandji procedure to arthrodese the distal radioulnar joint should be undertaken to stabilise the forearm while maintaining mobility


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 442 - 448
1 Mar 2021
Nikolaou VS Masouros P Floros T Chronopoulos E Skertsou M Babis GC

Aims

The aim of this study was to investigate the hypothesis that a single dose of tranexamic acid (TXA) would reduce blood loss and transfusion rates in elderly patients undergoing surgery for a subcapital or intertrochanteric (IT) fracture of the hip.

Methods

In this single-centre, randomized controlled trial, elderly patients undergoing surgery for a hip fracture, either hemiarthroplasty for a subcapital fracture or intramedullary nailing for an IT fracture, were screened for inclusion. Patients were randomly allocated to a study group using a sealed envelope. The TXA group consisted of 77 patients, (35 with a subcapital fracture and 42 with an IT fracture), and the control group consisted of 88 patients (29 with a subcapital fracture and 59 with an IT fracture). One dose of 15 mg/kg of intravenous (IV) TXA diluted in 100 ml normal saline (NS,) or one dose of IV placebo 100 ml NS were administered before the incision was made. The haemoglobin (Hb) concentration was measured before surgery and daily until the fourth postoperative day. The primary outcomes were the total blood loss and the rate of transfusion from the time of surgery to the fourth postoperative day.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 247 - 255
1 Feb 2021
Hassellund SS Williksen JH Laane MM Pripp A Rosales CP Karlsen Ø Madsen JE Frihagen F

Aims

To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years.

Methods

A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced AO/OTA A and C fractures were eligible if one of the following were found after initial closed reduction: 1) dorsal angulation > 10°; 2) ulnar variance > 3 mm; or 3) intra-articular step-off > 2 mm. Primary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) after 12 months. Secondary outcome measures were the Patient-Rated Wrist and Hand Evaluation (PRWHE), EuroQol-5 dimensions 5-level questionnaire (EQ-5D-5L), range of motion (ROM), grip strength, “satisfaction with wrist function” (score 0 to 10), and complications.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 13 - 13
1 May 2014
Arthur C Phillips J Toms A Mandalia V
Full Access

Kinematic alignment has increased in popularity over the last few years in an attempt to improve clinical outcomes following total knee arthroplasty (TKA). In our unit kinematic alignment has been used with patient-specific cutting guides as part of on-going clinical trials. We performed a retrospective analysis on all the TKA which had been planned to be implanted outside of the mechanical axis (0° ± 3°) based on pre-operative MRI scans and looked at their radiographic and clinical outcomes. We identified 21 knees which had been implanted as ‘planned outliers’. All had clinical and radiographic follow up to a mean 11.6 months post op. All had a standard long leg alignment radiograph performed at 6 weeks post op to confirm alignment. All patients had a good improvement in their Oxford Knee Scores with mean improvement from 23 pre-op to 42 at 1 year. Of our patients none had a poor clinical outcome due to the alignment of their TKA, 1 patient had a poor outcome because of a quadriceps rupture which occurred 4 months post-op. There were no post-operative radiographic abnormalities. In our unit kinematic alignment outside of the mechanical axis is not associated with an increased rate of short term complications


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_9 | Pages 14 - 14
1 May 2014
Guyver P Shuttlewood K Mehdi R Brinsden M Murphy A
Full Access

Our study aims to demonstrate the efficacy of using endobutton and interference screw technique in the repair of acute distal biceps ruptures. From April 2009 to May 2013, 25 consecutive patients had acute distal biceps tendon repairs using an endobutton and interference screw technique. 3 patients were lost to follow up leaving 22 patients available for review. Mean follow up was 24 months(1–51). All were evaluated using a questionnaire, examination, radiographs, power measurements, and Oxford Elbow and MAYO scores. Overall 95% patients (21/22) felt that their surgery was successful and rated their overall experience as excellent or good. Mean return to work was at 100 days(0–280) and mean postoperative pain relief was 23 days(1–56). 55% returned to sport at their pre-injury level. There was one case (4.5%) of heterotopic calcification with 3 superficial infections(14%). There were no intra or postoperative radial fractures, metalwork failures or metalwork soft tissue irritations. Mean pre-operative Oxford Elbow Scores were 18(6–37) and post operative 43(24–48) (p<0.00001). Mean pre-operative Mayo scores were 48(5–95) and post-operative were 95(80–100)(p<0.00001). Our study supports that distal biceps repairs using the endobutton and interference screw technique appears to lead to high patient satisfaction rates with a relatively early return to function