Advertisement for orthosearch.org.uk
Results 1 - 20 of 1300
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 536 - 539
1 May 2019
Cassidy RS O hEireamhoin S Beverland DE

Aims. The aim of this retrospective audit was to determine the route of referral or presentation of patients requiring revision following primary total hip arthroplasty (THA). Patients and Methods. A total of 4802 patients were implanted with an Orthopaedic Data Evaluation Panel (ODEP) 10A* cementless implant (Corail/Pinnacle) between 2005 and 2015; 80 patients with a mean age of 67.8 years (. sd. 10.8) underwent a subsequent revision. The primary outcome measure was route of referral for revision. Results. Of the 80 revisions, 31 (38.8%) took place within the first year and 69 (86.3%) took place within six years. Only two of the 80 patients were picked up at a routine review clinic, one for infection and the other for liner dissociation. A total of 36 revised patients (45.0%) were reviewed following self-referral. Of the remaining 44 revised patients (55.0%), 15 (18.8%) were General Practitioner referrals, 13 (16.3%) were other hospital referrals, six (7.5%) were inpatients, six (7.5%) were Emergency Department referrals, and two (2.5%) were readmitted from their homes. No revisions were carried out on asymptomatic patients. Conclusion. Our experience suggests that if there is a robust system in place for self-referral, patients with an ODEP 10A* hip implant can, if asymptomatic, be safely discharged at the time of their first postoperative review. Cite this article: Bone Joint J 2019;101-B:536–539


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 31 - 31
2 May 2024
Stedman T Hatfield T McWilliams A
Full Access

Arthroplasty in patients who are intravenous drug abusers presents a complex challenge, frequently requiring intervention at a younger age. The cohort suffer increased complication rates due to significant co-morbidities and poor engagement in medical services, in comparison to other patients undergoing lower limb arthroplasty. Multiple small studies show arthroplasty in this patient cohort is associated with high complication and mortality rates. A search of electronic databases were undertaken with the assistance of the library services from the Rotherham NHS Foundation Trust, including Chocraine, SCOPUS and PubMed. Abstracts were reviewed and relevant studies extracted for full review. Full text articles were reviewed based on strict inclusion and exclusion criteria. Searches identified Two thousand and forty-four papers; twenty-seven studies were identified for full review of the paper based on the inclusion criteria above. From this, nine studies were deemed appropriate to for data extraction. These nine papers present one hundred and thirty-two cases of lower limb arthroplasty, fifty nine Total Knee Arthroplasty and seventy three Total Hip Arthroplasty. From this the authors examined incidences of implant failure due to infection, revision, mortality, dislocation, aseptic loosening, peri-prosthetic fracture, or other causes. Of these, 58% of patients (n = 77) with a history of intravenous drug abuse suffered some form of significant complication; 4% of this cohort (n = 5) were lost to follow up. Infection was reported in 32% of cases and a mortality rate of 4.7%. The rising demand of lower limb arthroplasty for intra-venous drug abusers presents a very real problem for the modern Orthopaedic surgeon. Within the studies examined, more than half report implant failure. This study synthesises the available literature regarding treatment of these patients to help facilitate decision making and informed consent


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 10 - 10
7 Jun 2023
Mistry D Ahmed U Aujla R Aslam N D'Alessandro P Malik S
Full Access

Industries such as agriculture, construction and military have stringent rules about hearing protection due to the risk of noise induced hearing loss (NIHL). Due to the use of power tools, orthopaedic staff may be at risk of the same condition. The UK Health and Safety Executive (HSE) have clear standards as to what is deemed acceptable occupational noise levels on an A-weighted and C weighted scale. This review is aimed to assess evidence on noise exposure testing within Orthopaedic theatres to see if it exceeds the HSE regulations. A targeted search of online databases PUBMED and EMBASE was conducted using Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) principles. This review was registered prospectively in PROSPERO. An eligibility criterion identifying clinical studies which assessed noise exposure for Orthopaedic staff in theatres were included. Noise exposure data was extracted from these studies and a comparison was made with A weighted and C weighted acceptable exposure levels as quoted in the HSE regulations. Fourteen papers were deemed eligible, which reviewed 133 Orthopaedic operations and 64 Orthopaedic instruments. In total, 61% (81 of 132) of Orthopaedic operations and 70% (45 of 64) of instruments exceeded the noise regulations on an A weighted scale. 22% (10 of 46) of operations exceeded the maximum C weighted peak acceptable noise level. Orthopaedic instruments and operations can exceed safe occupational noise levels. NHS Trusts have clear policies about noise exposure in the workplace but have yet to identify Orthopaedic theatres as a potential at risk area. Orthopaedic staff need education, monitoring and protection whereas Employers and Occupational Health should consider assessments to identify at risk staff in Orthopaedic theatres and offer preventative methods from NIHL


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 39 - 39
2 May 2024
Saroha S Raheman F Jaiswal P Patel A
Full Access

In this study, we examined the impact of dual-mobility (DM) versus fixed-bearing (FB) implants on outcomes following total hip arthroplasty (THA), a common and successful operation. We examined all-cause revision, revision due to dislocation, postoperative complications and functional scores in patients undergoing primary and revision THA. A systematic review was performed according to PRISMA guidelines, and was registered in PROSPERO (ID CRD42023403736). The Cochrane Library, Embase, MEDLINE, Web of Science, and Scopus were searched from inception to 12th March 2023. Eligible studies underwent meta-analysis and methodological assessment using the ROBINS-I tool. Data were pooled using a random-effects maximum-likelihood model. Eight comparative, non-randomised studies involving 2,810 DM implants and 3,188 FB implants were included. In primary THA, the difference in all-cause revision was imprecise (OR 0.82, 95% CI 0.25–2.72), whilst the DM cohort had a statistically significant benefit in revision due to dislocation (OR 0.08, 95% CI 0.02–0.28). In revision THA, the DM cohort showed significant benefit in all-cause revision (OR 0.57, 95% CI 0.31–1.05) and revision due to dislocation (OR 0.14, 95% CI 0.04–0.53). DM implants were associated with a lower incidence of implant dislocation and infection. Functional outcome analysis was limited due to underreporting. No intraprosthetic dislocations were observed. The results suggest that contemporary DM designs may be advantageous in reducing the risk of all-cause revision, revision due to dislocation, and postoperative complication incidence at mid-term follow-up. Further high-quality prospective studies are needed to evaluate the long-term performance of this design, especially in revision cases


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 23 - 23
2 May 2024
Dulleston J Yoshitani J Fard ARR Khanduja V
Full Access

Although total hip arthroplasty (THA) is beneficial for many patients with hip osteoarthritis (OA), a subset of patients experience minimal benefit. It is therefore pertinent to understand the predictors of poor functional outcome to facilitate shared decision making. One such predictor is preoperative radiographic OA severity. The aim of this systematic review was to determine whether preoperative radiographic OA severity could predict postoperative patient-reported outcome measures (PROMs) and satisfaction rates after THA. This systematic review was conducted according to PRISMA guidelines, and the protocol published in PROSPERO (ID:Â CRD42023445918). A literature search was performed using Embase, MEDLINE and Cochrane Library databases. Demographics, radiographic OA severity, PROMs, satisfaction, and complications after THA were collected. A meta-analysis was performed, where appropriate, using a random-effects model. Of 631 identified articles, 12 were included in the final analysis (8,034 participants; mean age 65.2, 38.1% male, mean BMI 29.1 kg/m2). There were three key findings. Firstly, those with mild OA are less likely to achieve a meaningful clinical improvement in PROMs (odds ratio (OR) 0.50, 95% confidence interval (CI) 0.38, 0.65; p < 0.00001). Secondly, two studies indicates that postoperative patient satisfaction was lower in participants with mild OA. Thirdly, participants with mild arthritis experience less improvement in SF-36 physical functioning (mean difference (MD) -8.31, 95% CI -10.97, -5.64; p < 0.00001) and role physical (MD -5.59, 95% CI -8.40, -2.77; p < 0.0001), but showed higher improvement in general health (MD 1.68, 95% CI 0.31, 3.06; p = 0.02). Patients with mild OA, as determined radiographically, are less likely to achieve meaningful clinical improvements in PROMs and have lower postoperative satisfaction after THA. This information will improve collaborative decision-making in the preoperative period


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 24 - 30
1 Jan 2014
Haddad B Konan S Haddad FS

We have reviewed the current literature to compare the results of surgery aimed to repair or debride a damaged acetabular labrum. We identified 28 studies to be included in the review containing a total of 1631 hips in 1609 patients. Of these studies 12 reported a mean rate of good results of 82% (from 67% to 100%) for labral debridement. Of the 16 studies that reported a combination of debridement and re-attachment, five reported a comparative outcome for the two methods, four reported better results with re-attachment and one study did not find any significant difference in outcomes. Due to the heterogeneity of the studies it was not possible to perform a meta-analysis or draw accurate conclusions. Confounding factors in the studies include selection bias, use of historical controls and high rates of loss of follow-up. It seems logical to repair an unstable tear in a good quality labrum with good potential to heal in order potentially to preserve its physiological function. A degenerative labrum on the other hand may be the source of discomfort and its preservation may result in persistent pain and the added risk of failure of re-attachment. The results of the present study do not support routine refixation for all labral tears. Cite this article: Bone Joint J 2014;96-B:24–30


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 9 - 9
23 Jun 2023
Lachiewicz PF Skalla LA Purcell KP
Full Access

Severe heterotopic ossification (grade III and IV) after contemporary total hip arthroplasty (THA) requiring excision is very uncommon. We performed a systematic review of the literature, and report a new case series with operative treatment after primary uncemented THA. A systematic review identified papers describing patients who had excision of heterotopic ossification (HO) after contemporary THA, defined as performed after 1988. Concepts of hip arthroplasty, heterotopic ossification, and surgical excision were searched in MEDLINE, Embase, and Scopus, from database inception to November 2022. Inclusion criteria were: articles that included specific patient data on grade of heterotopic ossification, operative procedure, and prophylaxis. Studies were screened for inclusion by two independent reviewers. Extracted data included demographic data, interval from index surgery to excision, clinical results, and complications. One surgeon performed reoperation for ankylosis of primary THA in three patients with severe pain and deformity. Seven case series or case report studies were included. There were 41 patients, with grade III or IV HO, that had excision, and in five patients, revision of a component was also performed. Perioperative prophylaxis was irradiation alone in 10 patients, irradiation and indomethacin in 10, and indomethacin alone in 21 patients. At a mean follow-up time of 14.8 months, definition of the results was not uniform, and range of motion was improved, but relief of pain was inconsistent. There was one dislocation, one gastrointestinal complication, and two recurrences. Treatment of the three patients, with wide excision of peri-articular bone, selective exchange of components, and peri-operative irradiation prophylaxis, was successful in improving motion and deformity. There is insufficient data on the treatment of severe symptomatic HO after contemporary THA. Prophylaxis with low-dose irradiation was successful to prevent recurrence. Multicenter studies will be needed to determine the optimum timing and prognosis for treatment


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 27 - 27
1 Apr 2022
Evans J Inman D Johansen A
Full Access

The National Hip Fracture Database (NHFD) started collecting data on peri-prosthetic femoral fractures (PPFF) in December 2019. We reviewed the data from the first year of data collection to describe the patients being admitted with PPFF and the care they received according to established Key Performance Indicators (KPIs) used in hip fracture surgery. We performed a retrospective review of the NHFD between 1 January and 31 December 2020. Analyses consisted of the summary statistics used to generate the NHFD annual report. Of the KPIs used in hip fracture, data were available for PPFF on time to assessment by a geriatrician (KPI 1), time to theatre (if applicable) (KPI 2), and mobilisation the day after surgery (if applicable) (KPI 4). There were 2,411 PPFF fractures around a hip or knee replacement reported out of a total of 2,606 PPFF. Of the 171 hospitals reporting data to the NHFD, 135 reported at least one. The median number of fractures per hospital was 14 (IQR 8, 25, range 1 to 110). The median age of patients was 84 (range 60 to 104) and 1,604 (67%) patients were female. Of the 1,850 occasions a time to geriatrician review was documented, review within 72 hours was achieved on 89.2% of occasions. Of the 1,973 patients who underwent operative interventions, 546 patients went to theatre before the 36-hour target (28.4%). Of patients who had surgery 1,323 (67.4%) were mobilised the following day. In the first year collecting data on PPFF we can give the first idea of the incidence of these life changing injuries. Whilst geriatrician review with 72 hours was achieved in a high proportion of cases nationally, our data suggest fewer patients are mobilised the day after surgery. Notably, only 28.4% of patients who were managed operatively went to theatre within 36 hours of admission. We provide the first insight into the incidence and management of these injuries


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 578 - 582
1 May 2013
Kim S Postigo R Koo S Kim JH

The timing of total hip replacement (THR) in patients with active tuberculosis (TB) of the hip is controversial, because of the potential risk of reactivation of infection. There is little information about the outcome of THR in these patients. We conducted a systematic review of published studies that evaluated the outcome of THR in patients with active TB of the hip. A review of multiple databases referenced articles published between 1950 and 2012. A total of six articles were identified, comprising 65 patients. TB was confirmed histologically in all patients. The mean follow-up was 53.2 months (24 to 108). Antituberculosis treatment continued post-operatively for between six and 15 months, after debridement and THR. One non-compliant patient had reactivation of infection. At the final follow-up the mean Harris hip score was 91.7 (56 to 98). We conclude that THR in patients with active TB of the hip is a safe procedure, providing symptomatic relief and functional improvement if undertaken in association with extensive debridement and appropriate antituberculosis treatment. Cite this article: Bone Joint J 2013;95-B:578–82


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 12 - 12
1 Apr 2022
Walton T Huntley D Whitehouse S Ross A Kassam A
Full Access

The aim of this study was to systemically review the evidence for the use of intra-operative cell salvage (ICS) among patients undergoing revision hip arthroplasty, and synthesis the available data to quantify any associated reduction in allogeneic blood transfusion. An electronic database search of MEDLINE (PubMed), EMBASE, Scopus and the Cochrane Library was completed from the date of inception to 9. th. February 2021, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were (i) adult patients >18 years, (ii) ICS utilised in one study group, (iii) revision hip arthroplasty performed. Exclusion criteria were (i) pre-donation of red blood cells, (ii) mixed reporting without dedicated subgroup analysis for revision hip arthroplasty. Screening for eligibility, and quality assessment of included studies, was performed independently by two authors (TW and DH), and any disputes settled by third author (AK). Of the 187 records identified, 11 studies were included in the qualitative analysis, and 5 studies suitable for quantitative meta-analysis. Across the included studies there were 1856 participants, with a mean age of 63.86 years and a male: female ratio of 0.90. Quality assessment demonstrated low or medium risk of bias only. For revision hip arthroplasty patients receiving ICS, 37.07% required ABT with a mean transfusion of 1.92 units or 385ml per patient. For patients treated without ICS, 64.58% required ABT with a mean transfusion of 4.02 units or 803ml per patient. This difference achieved statistical significance (p < 0.05). This study has demonstrated a significant reduction in the need for allogenic blood transfusion associated with intra-operative cell salvage use among patients undergoing revision hip arthroplasty. This study therefore supports the routine use of ICS in this patient group. However, a major limitation is the lack of clinical outcomes reported by the available studies. Further research is required to determine whether this effect is associated with sub-groups of revision arthroplasty procedure, and whether ICS impacts clinical outcomes such as length of stay, rehabilitation progress and mortality


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 22 - 22
7 Jun 2023
Sahemey R Ridha A Stephens A Farhan-Alanie M Riemer B Jozdryk J
Full Access

Revision total hip arthroplasty (rTHA) in the presence of femoral defects can be technically challenging. Reconstruction with long stems is widely accepted as the standard. However long stems can be difficult to insert and can compromise distal bone stock for future revisions. The aims of this study were to identify whether there was a difference in survival and outcomes following rTHA using a long versus standard or short femoral stem. A comprehensive systematic review was performed according to PRISMA guidelines using the MEDLINE, EMBASE, Chochrane Library and Web of Science databases. Inclusion criteria were (i) adult patients >18 years; (ii) randomised controlled trials, joint registry, or cohort studies; (iii) single or staged rTHA for Paprosky 1–3B femoral defects. Exclusion criteria were (i) mixed reporting without subgroup analysis for revision stem length; (ii) ex-vivo studies. Screening for eligibility and assessment of studies was performed by the authors. Out of 341 records, 9 studies met criteria for analysis (including 1 study utilising joint registry data and 1 randomised controlled trial). Across studies there were 3102 rTHAs performed in 2982 patients with a mean age of 67.4 years and a male: female ratio of 0.93. Revision prostheses were long-stemmed in 1727 cases and short or standard in 1375 cases with a mean follow up of 5 years (range, 0-15 years). On subgroup analysis the use of a long cemented stem compared to a long cementless prosthesis was associated with fewer complications and periprosthetic fracture in older patients. Survivorship was 95% with short stems compared to 84% with long stems at 5 years. Moderate quality evidence suggests that in rTHA with Paprosky type 1-3B femoral defects, the use of a short or standard stem can achieve comparable outcomes to long stems with fewer significant complications and revisions. Using a shorter stem may yield a more straightforward surgical technique and can preserve distal bone stock for future revision


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 19 - 19
1 Apr 2022
Lim A Zhu J Khanduja V
Full Access

There are a number of patients in whom hip preservation surgery is not indicated as they have developed signs of early osteoarthritis, and nor can they have a hip replacement as they are too early in the disease process. The use of PRP in OA of the hip has not been studied systematically and this study concisely collates all the available data in the use of PRP in Hip OA. This systematic review and meta-analysis aimed to assess intra-articular platelet-rich plasma as a therapeutic intervention for hip osteoarthritis, including the duration of efficacy, influence of dose and composition of PRP, and the incidence of adverse effects. We performed literature searches on the MEDLINE, EMBASE, CINHAL, WEB OF SCIENCE, COCHRANE and SCOPUS databases, and PRSIMA guidelines were followed. Data was pooled using random effects meta-analysis. We assessed quality of the included studies using the Methodological Index for Non-Randomised Studies (MINORS) instrument, with an additional assessment for Randomised Controlled Trials with the Revised Cochrane risk-of-bias tool for randomized trials (RoB 2). Eight studies were included in the analysis, with data from a total of 331 patients. PRP significantly reduced pain compared to baseline at multiple timepoints, with the greatest effect at 1–2mo follow-up. PRP only significantly improved function at the 1–2mo follow-up. A significantly larger reduction in pain was achieved with a single injection or PRP compared to multiple injections, a total injected dose of PRP <15mL compared to ≥15mL or using a leukocyte-poor PRP preparation compared to leukocyte-rich PRP. There were no lasting adverse effects. Low and moderate quality evidence suggests that PRP reduces pain and improves function at endpoint compared to baseline. Moderate quality evidence suggests a larger reduction in pain is achieved with a single injection of PRP compared to multiple injections, and low quality evidence attributes a larger reduction of pain with a total injected dose of PRP <15mL compared to ≥15mL or using leukocyte-poor PRP compared to leukocyte-rich PRP


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 732 - 737
1 Jun 2013
Kosuge D Yamada N Azegami S Achan P Ramachandran M

The term developmental dysplasia of the hip (DDH) describes a spectrum of disorders that results in abnormal development of the hip joint. If not treated successfully in childhood, these patients may go on to develop hip symptoms and/or secondary osteoarthritis in adulthood. In this review we describe the altered anatomy encountered in adults with DDH along with the management options, and the challenges associated with hip arthroscopy, osteotomies and arthroplasty for the treatment of DDH in young adults. Cite this article: Bone Joint J 2013;95-B:732–7


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 23 - 23
7 Jun 2023
Coveney E Hutton C Patel N Whitehouse S Howell J Wilson M Hubble M Kassam A
Full Access

Venous thromboembolism (VTE) is a preventable cause of morbidity and mortality in patients undergoing elective hip arthroplasty surgery. The balance of post-operative VTE prophylaxis and risk of post-operative haemorrhage remains at the forefront of surgeon's mind. The National Institute for Clinical Excellence (NICE) has altered their prophylaxis guidance in the setting of total hip arthroplasty (THA). The aim of this study was to present the VTE incidence in 8,890 patients who underwent total hip arthroplasty between January 1997 and March 2018 with Aspirin as the primary agent for pharmacological thromboprophylaxis. Analysis of prospective data collection from consecutive patients undergoing THA was performed with the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) occurring within 6 months of the index operation as the primary outcome measure. 90-day all-cause mortality of this cohort of patients was also analysed. 8890 patients were reviewed. This included 7235 primary, 224 complex primary and 1431 revision cases. The incidence of DVT was 0.64% after elective THA and the incidence of PE was 0.54%. There was no difference in the incidence between primary and revision cases. The 90-day all-cause mortality was 0.88%. Cardiovascular and respiratory disease were the main causes of death following surgery. Only 0.03% of deaths (n= 3) within 90 days of index surgery were due to VTE. Our results support the use of aspirin as an effective form of prophylaxis against VTE following THA. It is not associated with an increased incidence in symptomatic DVT, PE or death compared to other published studies. The fact that it is inexpensive, readily available, requires no monitoring and does not pose an increased risk of bleeding are other attractive advantages of using aspirin for VTE prophylaxis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 29 - 29
2 May 2024
Gibbs V Champaneria R Sandercock J Welton N Geneen L Brunskill S Doree C Kimber C Palmer A Estcourt L
Full Access

Preoperative anaemia and intraoperative blood loss result in ∼90% of individuals being anaemic following hip and knee arthroplasty. Reducing blood loss offers the opportunity to improve outcomes and reduce the risk of transfusion and costs. This review's aim was to determine the effectiveness of drugs for preventing blood loss, and identify optimal dose, route, and timing of administration. Cochrane network meta-analysis of randomised controlled trials was conducted. Inclusion criteria: adults undergoing primary or revision elective hip or knee arthroplasty. Drugs studied: tranexamic acid (TXA), aprotinin, epsilon-aminocaproic acid, desmopressin, factor VIIa and XIII, fibrinogen, fibrin sealants, and non-fibrin sealants. Primary outcomes: need for allogenic blood transfusion, all• cause mortality (within 30 days). Secondary outcomes: mean number of transfusion episodes, re-operation, length of hospital stay and adverse events (DVT, PE, CVA, MI). 102 studies with 8418 participants. Trials included more women (63%). 47 studies (4398 participants) were included within the blood transfusion NMA. TXA given intra-articularly and orally at a total dose of greater than 3g pre-incision, intraoperatively and postoperatively ranked the highest, with anticipated absolute effect of 147 fewer transfusions per 1000 (53% chance ranking 1st) (relative risk(RR) 0.02, 95% credible interval(CrI) 0–0.31); moderate-certainty). Aprotinin (RR 0.59, 95%:CrI 0.36–0.86; low certainty evidence), fibrin (RR 0.86, CrI 0.25–2.93; very-low certainty) and EACA (RR 0.60, 95%:CrI 0.29–1.27; very-low certainty) were not shown to be as effective as TXA. TXA was the most effective drug for preventing bleeding in lower limb arthroplasty. Aprotinin and EACA were not as effective. Currently, the optimal dose, route and timing of administration of TXA is unclear. However, TXA given at higher doses and via mixed routes ranked higher in the treatment hierarchy. Oral TXA may be as effective as intavenous. There was no evidence of harm associated with higher doses of TXA


Bone & Joint Open
Vol. 2, Issue 2 | Pages 93 - 102
1 Feb 2021
Thompson JW Wignadasan W Ibrahim M Beasley L Konan S Plastow R Magan A Haddad FS

Aims. We present the development of a day-case total hip arthroplasty (THA) pathway in a UK National Health Service institution in conjunction with an extensive evidence-based summary of the interventions used to achieve successful day-case THA to which the protocol is founded upon. Methods. We performed a prospective audit of day-case THA in our institution as we reinitiate our full capacity elective services. In parallel, we performed a review of the literature reporting complication or readmission rates at ≥ 30-day postoperative following day-case THA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed. Results. Our evaluation and critique of the evidence-based literature identifies day-case THA to be safe, effective, and economical, benefiting both patients and healthcare systems alike. We further validate this with our institutional elective day surgery arthroplasty pathway (EDSAP) and report a small cohort of successful day-case THA cases as an example in the early stages of this practice in our unit. Conclusion. Careful patient selection and education, adequate perioperative considerations, including multimodal analgesia, surgical technique and blood loss management protocols and appropriate postoperative pathways comprising reliable discharge criteria are essential for successful day-case THA. Cite this article: Bone Jt Open 2021;2(2):93–102


Bone & Joint Research
Vol. 10, Issue 9 | Pages 574 - 590
7 Sep 2021
Addai D Zarkos J Pettit M Sunil Kumar KH Khanduja V

Outcomes following different types of surgical intervention for femoroacetabular impingement (FAI) are well reported individually but comparative data are deficient. The purpose of this study was to conduct a systematic review (SR) and meta-analysis to analyze the outcomes following surgical management of FAI by hip arthroscopy (HA), anterior mini open approach (AMO), and surgical hip dislocation (SHD). This SR was registered with PROSPERO. An electronic database search of PubMed, Medline, and EMBASE for English and German language articles over the last 20 years was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We specifically analyzed and compared changes in patient-reported outcome measures (PROMs), α-angle, rate of complications, rate of revision, and conversion to total hip arthroplasty (THA). A total of 48 articles were included for final analysis with a total of 4,384 hips in 4,094 patients. All subgroups showed a significant correction in mean α angle postoperatively with a mean change of 28.8° (95% confidence interval (CI) 21 to 36.5; p < 0.01) after AMO, 21.1° (95% CI 15.1 to 27; p < 0.01) after SHD, and 20.5° (95% CI 16.1 to 24.8; p < 0.01) after HA. The AMO group showed a significantly higher increase in PROMs (3.7; 95% CI 3.2 to 4.2; p < 0.01) versus arthroscopy (2.5; 95% CI 2.3 to 2.8; p < 0.01) and SHD (2.4; 95% CI 1.5 to 3.3; p < 0.01). However, the rate of complications following AMO was significantly higher than HA and SHD. All three surgical approaches offered significant improvements in PROMs and radiological correction of cam deformities. All three groups showed similar rates of revision procedures but SHD had the highest rate of conversion to a THA. Revision rates were similar for all three revision procedures


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 5 - 5
1 Aug 2021
Thompson J Corbett J Bye D Jones A Tissingh E Nolan J
Full Access

The Exeter. ™. V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems. A systematic literature search was performed adhering to PRISMA criteria. In parallel we performed a retrospective single centre study of Exeter. ™. V40 femoral stem prosthetic fractures between April 2003– June 2020. There are 25 reported cases of such prosthetic fractures confined to small case series and case reports within the literature. We report an additional 19 cases to the literature (mean age 66.3 ± 11.7 years; 12 female [63%]; body mass index 32.9 ± 5.9 kg/m. 2. ). The mean time from index procedure to fracture was 7.8 years (2.5–16.3, ±3.6). Exeter V40 stem fracture incidence was 0.27%. Incidence was significantly higher in 125 mm length stems compared to ≥150 mm length stems (1.26% vs 0.13%, respectively, p <0.001) and revision arthroplasty (1.209% vs 0.149%, p <0.001). When comparing different stem length cohorts, 125-mm short-stem were associated with stem body fractures (92% vs 29%, p = 0.0095), earlier time to fracture (6.2 vs 11.0 years, p = 0.0018), younger patient age at time of fracture (62.7 vs 72.6 years old, p = 0.037) and female sex (75% vs 43%, p = 0.33). This case series in conjunction with the systematic review provides evidence stem morphology plays a role in femoral implant fracture. This complication remains rare, although we report a significantly higher incidence at up to 17 years follow-up than in the literature. As femoral geometries remain the same, increasing BMIs in THR patients should raise concern. Short 125 mm length Exeter V40 stems undoubtedly have a role in restoring anatomy and biomechanics in smaller femoral geometries, although the surgeon has to appreciate the higher risk of stem fracture and the associated predisposing factors which may necessitate meticulous surgical technique and planning


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 9 - 9
19 Aug 2024
Pulik Ł Łęgosz P Brzóska E Mierzejewski B Grabowska I Ciemerych MA Hube R
Full Access

This meta analysis address the relationship between infection developing after total hip arthroplasty (THA) and heterotopic ossification (HO). To identify the gaps in available knowledge, we screened for full-length peer-reviewed research articles listed in PubMed, Embase, and Web of Science over the past 20 years. The following search terms and Boolean operators were used: heterotopic ossification AND infection AND (hip replacement OR hip arthroplasty). The search resulted in the identification of as few as 14 articles describing periprosthetic joint infection (PJI) and HO after THA. Data summarized from 6 studies suitable for further meta-analysis yielded a cumulative sample size of 753 observations, with 186 recorded events of HO. The pooled RR was estimated at 2.22 (95% CI: 1.00 to 4.91, p = 0.0497), suggesting a more than twofold risk of HO compared to the group without PJI. In conclusion, there is a clear association between a higher risk of HO and PJI. Basic research findings support the hypothesis that bacterial pathogen-associated molecular patterns (PAMPs) can lead to osteogenesis through a toll-like receptor (TLR) and nuclear factor kappa B (NF-κB) pathway in the course of HO development. Together, these results suggest that HO prophylaxis should always be prescribed in PJI after THA. Moreover, during revisions following THA for presumed non-septic reasons, the presence of HO warrants consideration for infection, as there is a potential heightened risk of pathologic ossification induced by PAMPs.

Keywords: heterotopic ossification; total hip arthroplasty; total hip replacement; periprosthetic joint infection; bacteria

Authors Ł. Pulik and P. Łęgosz contributed equally to this work.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 71 - 78
1 Jan 2021
Maggs JL Swanton E Whitehouse SL Howell JR Timperley AJ Hubble MJW Wilson MJ

Aims. Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification. Methods. We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment. Results. In total, 47 B2W fractures (54.0%) and one B3 fracture (1.1%) had cement that remained well-fixed at the cement-bone interface. These cases were treated with cement-in-cement (CinC) revision arthroplasty. Overall, 43 fractures with follow-up united, and two patients sustained further fractures secondary to nonunion and required further revision surgery. A total of 19 B2L fractures (21.8%) and 19 B3 fractures (21.8%) had cement that was loose at the cement-bone interface. These cases were managed by revision arthroplasty with either cemented or uncemented femoral components, or proximal femoral arthroplasty. One case could not be classified. Conclusion. We endorse a modification of the original Vancouver system to include a subclassification of B2 fractures around cemented femoral prostheses to include B2W (where cement is well-fixed to bone) and B2L (where the cement is loose). Fractures around taper-slip design stems are more likely to fracture in a B2W pattern compared to fractures around composite beam design stems which are more likely to fracture in a B2L pattern. B2W fractures can reliably be managed with CinC revision. Cite this article: Bone Joint J 2021;103-B(1):71–78