Aims. In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene bearings match those of Birmingham hip MoM components. If the acetabular component is satisfactorily positioned, well integrated into the bone, and has no surface damage, this presents the opportunity for revision with exchange of the metal head for ADM/MDM polyethylene bearings without removal of the acetabular component. Methods. Between 2012 and 2020, across two centres, 94 patients underwent revision of Birmingham MoM hip arthroplasties or resurfacings. Mean age was 65.5 years (33 to 87). In 53 patients (56.4%), the acetabular component was retained and dual-mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). Patients underwent follow-up of minimum two-years (mean 4.6 (2.1 to 8.5) years). Results. In the DM group, two (3.8%) patients underwent further surgery: one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (9.8%) underwent further procedures: two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operating time (68.4 vs 101.5 mins, p < 0.001), postoperative drop in haemoglobin (16.6 vs 27.8 g/L, p < 0.001), and length of stay (1.8 vs 2.4 days, p < 0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p < 0.001), although there was no difference between groups for this reduction (p = 0.674 (cobalt); p = 0.186 (chromium)). Conclusion. In selected patients with Birmingham MoM hips, where the acetabular component is well-fixed and in a satisfactory position with no surface damage, the metal head can be exchanged for polyethylene ADM/MDM bearings with
In metal-on-metal (MoM) hip replacements or resurfacings, mechanical induced corrosion can lead to a local inflammatory response, pseudo tumours and elevated serum metal ions, requiring revision surgery. The size and diametral clearance of Anatomic (ADM) and Modular (MDM) Dual Mobility bearings matches that of certain MOM components. Presenting the opportunity for revision with exchange of the metal head for ADM/MDM bearings without removal of the acetabular component if it is well-fixed and appropriately positioned. Between 2012 and 2020, across two centres, 94 patients underwent revision of a MoM hip replacement or resurfacing. The mean age was 65.5 (33–87) years. In 53 patients (56.4%), the acetabular component was retained, and dual mobility bearings were used (DM); in 41 (43.6%) the acetabulum was revised (AR). DM was only considered where the acetabular component was satisfactorily positioned and well-integrated into bone, with no surface damage. Patients underwent clinical and radiographic follow-up to at least one-year (mean 42.4 (12–96) months). One (1.1%) patient died before one-year, for reasons unrelated to the surgery. In the DM group, two (3.8%) patients underwent further surgery; one (1.9%) for dislocation and one (1.9%) for infection. In the AR group, four (12.2%) underwent further procedures; two (4.9%) for loosening of the acetabular component and two (4.9%) following dislocations. There were no other dislocations in either group. In the DM group, operative time (68.4 v 101.5 mins, p<0.001), postoperative drop in haemoglobin (16.6 v 27.8 g/L, p<0.001), and length of stay (1.8 v 2.4 days, p<0.001) were significantly lower. There was a significant reduction in serum metal ions postoperatively in both groups (p<0.001 both Cobalt and Chromium) although there was no difference between groups for this reduction (p=0.674 Cobalt; p=0.186 Chromium). In selected patients with MoM hip arthroplasty, where the acetabular component is well-fixed, in a satisfactory position and there is no surface damage, the metal head can be exchanged for ADM/MDM bearings with
Although cement in cement acetabular revision is a recognised option in the presence of a well-fixed cement mantle, partial cement mantle
Introduction. We aim to evaluate the outcome of debridement and implant
To analyse the effectiveness of debridement and implant retention
(DAIR) in patients with hip periprosthetic joint infection (PJI)
and the relationship to patient characteristics. The outcome was
evaluated in hips with confirmed PJI and a follow-up of not less
than two years. Patients in whom DAIR was performed were identified from our
hip arthroplasty register (between 2004 and 2013). Adherence to
criteria for DAIR was assessed according to a previously published
algorithm.Aims
Patients and Methods
Advocates of debridement, antibiotics and implant retention (DAIR)
in hip periprosthetic joint infection (PJI) argue that a procedure
not disturbing a sound prosthesis-bone interface is likely to lead
to better survival and functional outcome compared with revision.
This case-control study aims were to compare outcome of DAIRs for
infected primary total hip arthroplasty (THA) with outcomes following
primary THA and two-stage revision of infected primary THAs. We retrospectively reviewed all DAIRs, performed for confirmed
infected primary hip arthropasty (n = 82) at out institution, between
1997 and 2013. Data recorded included full patient information and
type of surgery. Outcome measures included complications, mortality,
implant survivorship and functional outcome. Outcome was compared with
two control groups matched for gender and age; a cohort of primary
THAs (n = 120) and a cohort of two-stage revisions for infection
(n = 66).Aims
Patients and Methods
The outcome at ten years of 100 Freeman hip stems (Finsbury Orthopaedics, Leatherhead, United Kingdom) retaining the neck with a proximal hydroxyapatite coating in a series of 52 men (six bilateral) and 40 women (two bilateral), has been described previously. None required revision for aseptic loosening. We have extended the follow-up to 20 years with a minimum of 17 years. The mean age of the patients at total hip replacement was 58.9 years (19 to 84). Six patients were lost to follow-up, but were included up to their last clinical review. A total of 22 patients (22 hips) had died, all from causes unrelated to their surgery. There have been 43 re-operations for failure of the acetabular component. However, in 38 of these the stem was not revised since it remained stable and there was no associated osteolysis. Two of the revisions were for damage to the trunnion after fracture of a modular ceramic head, and in another two, removal of the femoral component was because of the preference of the surgeon. In all cases the femoral component was well fixed, but could be extracted at the time of acetabular revision. In one case both components were revised for deep infection. There has been one case of aseptic loosening of the stem which occurred at 14 years. This stem had migrated distally by 7.6 mm in ten years and 8.4 mm at the time of revision at which stage it was found to be rotationally loose. With hindsight this component had been undersized at implantation. The survivorship for the stem at 17 years with aseptic loosening as the endpoint was 98.6% (95% confidence interval 95.9 to 100) when 62 hips were at risk. All remaining stems had a satisfactory clinical and radiological outcome. The Freeman proximally hydroxyapatite-coated femoral component is therefore a dependable implant and its continued use can be recommended.
The reported success rate after treatment with debridement, antibiotics and implant retention (DAIR) of hip prosthesis infections has been found variable. We evaluated all reoperations performed because of infection and reported to Swedish Hip Arthroplasty Register (SHAR) between 1999 and 2016. The analyses were separated into reoperations performed for the first time and those which had been preceded by at least one previous reoperation performed because of the same reason. The outcome was repeated reoperation performed because of infection. 1,882 were first-time procedures (Group I) and 2,275 had been preceded by at least one reoperation due to infection (Group II). Head and/or liner exchange had been performed in 47% of the cases in group I, and in 22% in Group II. The mean age varied between 70 and 71 years and there was a dominance of males in all groups (52–59%). Compared to all primary THR performed during this period (n=319,813) patients with inflammatory disease, idiopathic femoral head necrosis and sequel after childhood disease were overrepresented for this type of procedure. Between 1999 and 2016 the number of DAIR procedures increased from 29 to 383 per year corresponding to 21 and 72 % of all reoperations performed due to infection. In first time reoperations the survival was 74.5±3.1% if the head/liner had been exchanged and 46.2±3.2% if only irrigation and synovectomy had been performed. In patients reoperated at least one time previously due to infection the survival rates dropped to 68.6±4.6% and 34.5±2.4%. Compared to first time reoperation with exchange of femoral and/or liner, synovectomy and irrigation without exchange of any implant part(s) resulted in an almost tripled risk of a second reoperation due to same reason (Hazard Ratio: 2.8, 95% confidence interval: The comparatively good results observed after exchange of head and liner might indicate that this is necessary to perform a sufficiently radical debridement. This observation could also be biased by a surgeon related factor suggesting that component exchange mainly is performed by surgeons with long experience of revision surgery.
The aims of the study were to review and analyse the reported
series of debridement, antibiotics and implant retention (DAIR)
in the management of infected total hip arthroplasties (THAs) to
establish the overall success and the influencing factors. Using a standardised recognised study protocol, meta-analysis
of observational studies in epidemiology guidelines, a comprehensive
review and analysis of the literature was performed. The primary
outcome measure was the success of treatment. The search strategy
and inclusion criteria which involved an assessment of quality yielded
39 articles for analysis, which included 1296 patients.Aims
Patients and methods
The value of Debridement-Antibiotics-and-Implant-Retention (DAIR) in prosthetic-joint-infection (PJI) is still a matter of debate as most studies to-date are underpowered with variable end-points. In our, tertiary referral, bone infection unit we consider DAIR to be a suitable option in all PJIs with soundly fixed prostheses, despite chronicity. The aims of this study were to define the long-term outcome following DAIR in hip PJI and identify factors that influence it. This is a retrospective consecutive case series of DAIRs performed between 1997 and 2013. Only infected cases confirmed by established criteria were included. Data recorded included patient demographics, medical history (ASA grade, Charlson and KLICC scores), type of surgery performed (DAIR or DAIR + exchange of modular components) and organism grown. Outcome measures included complications, implant survivorship and functional outcome (Oxford Hip Score, OHS).Introduction
Methods
The aims of the study were primarily to establish the overall success of debridement, antibiotics and implant retention (DAIR) in the management of infected total hip replacements (THRs) and secondarily to identify risk factors for failure. Using a standardised and recognised study protocol (“Meta-analysis of observational studies in epidemiology (MOOSE) guidelines) a systematic review and meta-analysis of the literature was performed. The primary outcome measure of interest was treatment success. The search strategy and inclusion criteria plus quality assessment yielded 39 articles eligible for analysis. The proportion of success from the literature following DAIR in the management of infected THRs is improving over time – the pooled mean proportion of success is 84.5% in studies from 2011–15. There was improved success with early debridement (75.7%) compared with delayed debridement (48.1%) (p=0.006). The reported outcomes following DAIR appear to be improving with time. One of the most influential determinants of outcome is timing of debridement from onset of symptoms. Surgeons should have a low threshold for investigating deep infection when presented with an acutely symptomatic THR and be aware of the updated reported outcomes associated with DAIR when considering management options.
Aims. The aim of this study was to examine the implant accuracy of custom-made partial pelvis replacements (PPRs) in revision total hip arthroplasty (rTHA). Custom-made implants offer an option to achieve a reconstruction in cases with severe acetabular bone loss. By analyzing implant deviation in CT and radiograph imaging and correlating early clinical complications, we aimed to optimize the usage of custom-made implants. Methods. A consecutive series of 45 (2014 to 2019) PPRs for Paprosky III defects at rTHA were analyzed comparing the preoperative planning CT scans used to manufacture the implants with postoperative CT scans and radiographs. The anteversion (AV), inclination (IC), deviation from the preoperatively planned implant position, and deviation of the centre of rotation (COR) were explored. Early postoperative complications were recorded, and factors for malpositioning were sought. The mean follow-up was 30 months (SD 19; 6 to 74), with four patients lost to follow-up. Results. Mean CT defined discrepancy (Δ) between planned and achieved AV and IC was 4.5° (SD 3°; 0° to 12°) and 4° (SD 3.5°; 1° to 12°), respectively. Malpositioning (Δ > 10°) occurred in five hips (10.6%). Native COR reconstruction was planned in 42 cases (93%), and the mean 3D deviation vector was 15.5 mm (SD 8.5; 4 to 35). There was no significant influence in malpositioning found for femoral stem
We hypothesised that the removal of the subchondral
bone plate (SCBP) for cemented acetabular component fixation in
total hip arthroplasty (THA) offers advantages over
The management of prosthetic joint infection (PJI) has been widely performed for total hip arthroplasties (THA), but none has compared it with hip resurfacing arthroplasty (RSA). We also carried out a retrospective case-control study comparing the surgical treatment of PJI by surgical debridement and implant
Aims. Periprosthetic joint infections (PJIs) with prior multiple failed surgery for reinfection represent a huge challenge for surgeons because of poor vascular supply and biofilm formation. This study aims to determine the results of single-stage revision using intra-articular antibiotic infusion in treating this condition. Methods. A retrospective analysis included 78 PJI patients (29 hips; 49 knees) who had undergone multiple prior surgical interventions. Our cohort was treated with single-stage revision using a supplementary intra-articular antibiotic infusion. Of these 78 patients, 59 had undergone more than two prior failed debridement and implant
High doses of intra-articular (IA) antibiotics has been shown to effectively achieve a minimal biofilm eradication concentration which could mitigate the need for removal of infected but well-ingrown cementless components of a total hip arthroplasty (THA). However, there are concerns that percutaneous catheters could lead to multi-resistance or multi-organism peri-prosthetic joint infections (PJI) following single stage THA revisions for PJI. Eighteen single-stage revision procedures were performed for acute (N=9) or chronic (N=9) PJI following a primary (N=12) or revision (N=6) cementless THA. Modular and loosened components were replaced. All well ingrown components were retained. Two Hickmann catheters were placed in the joint space. Along with intravenous antibiotics, IA antibiotics were injected twice a day for two weeks, followed by 3 months of oral antibiotics. Per-operative cultures demonstrated 4 multi-bacterial PJIs. None of the patients developed post-operatively an AB related renal or systemic dysfunction. At a mean follow-up of 38 months [range, 8–72] all patients had normal erythrocyte sedimentation rate and white blood cell count. Four had a slightly elevated C-reactive protein but were completely symptom free and did not show any sign of loosening at a mean of 27 months [range, 16–59]. Addition of high doses of IA antibiotics following single-stage revision for PJI in cementless THA, is an effective and safe treatment option that allows for
Periprosthetic joint infection is a serious complication of primary total hip replacement (THR) with significant associated morbidity. In acute infection, Debridement, Antibiotics and Implant
Dislocation after total hip replacement (THR) is a devastating complication. Risk factors include patient and surgical factors. Mitigation of this complication has proven partially effective. This study investigated a new innovating technique to decrease this problem using rare earth magnets. Computer simulations with design and magnetic finite element analysis software were used to analyze and quantitate the forces around hip implants with embedded magnets into the components during hip range of motion. N52 Neodymium-Iron-Boron rare earth magnets were sized to fit within the existing acetabular shells and the taper of a hip system. Additionally, magnets placed within the existing screw holes were studied. A 50mm titanium acetabular shell and a 36mm ceramic liner utilizing a taper sleeve adapter were modeled which allowed for the use of a 12mm × 5mm magnet placed in the center hole, an 18mm × 15mm magnet within the femoral head, and 10mm × 5mm magnets in the screw holes. Biomechanical testing was also performed using in-vitro bone and implant models to determine
For over a decade, modular titanium fluted tapered (TFT) stems have demonstrated excellent clinical success for femoral revision total hip arthroplasty (THA) surgery. The aim of this study was to report the short-term outcomes of a novel modern monoblock TFT stem used for revision and complex primary THA with a minimum of 2 years follow-up. We identified 126 patients who received a single monoblock TFT stem - 26 patients for complex THA (failed fracture fixation) and 100 patients for revision THA. The reasons for revision THA included 40 for previous prosthetic joint infection (PJI), 42 for aseptic loosening, 9 for trunnionosis, 9 for periprosthetic fractures. The Paprosky grading for femoral bone loss at the time of surgery and the measured subsidence of femoral stems at 3 months follow-up were determined. We evaluated the number and indications for re-operations. The mean time from surgery was 3.9 years (range 2.0 to 6.9 years). A paired t-test analysis showed significant improvement from pre-operative versus post-operative clinical outcome scores (p<0.001) for HHS (38.76 +/- 15.24vs. 83.42 +/- 15.38), WOMAC (45.6 ± 19.0 vs. 69.9 ± 21.3) and SF-12 Physical component (31.7 ± 8.1 vs. 37.8 ± 11.3) and SF-12 Mental component (48.2 ± 12.2 vs. 51.6 ± 12.5). The Paprosky grading for femoral bone loss was Grade 1 (3.9%), Grade 2 (35.7%), Grade 3A (47.6%), Grade 3B (11.1%) and Grade 4 (1.6%) cases. There were 18 re-operations (14.7%) with 13 for PJI (7 treated with implant
Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation. We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103). DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup