Advertisement for orthosearch.org.uk
Results 1 - 20 of 490
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 32 - 32
1 Dec 2022
Kamikovski I Woodmass J McRae S Lapner P Jong B Marsh J Old J Dubberley J Stranges G MacDonald PB
Full Access

Previously, we conducted a multi-center, double-blinded randomized controlled trial comparing arthroscopic Bankart repair with and without remplissage. The end point for the randomized controlled trial was two years post-operative, providing support for the benefits of remplissage in the short term in reducing recurrent instability. The aim of this study was to compare the medium term (3 to 9 years) outcomes of patients previously randomized to have undergone isolated Bankart repair (NO REMP) or Bankart repair with remplissage (REMP) for the management of recurrent anterior glenohumeral instability. The rate of recurrent instability and instances of re-operation were examined. The original study was a double-blinded, randomized clinical trial with two 1:1 parallel groups with recruitment undertaken between 2011 and 2017. For this medium-term study, participants were reached for a telephone follow-up in 2020 and asked a series of standardized questions regarding ensuing instances of subluxation, dislocation or reoperation that had occurred on their shoulder for which they were randomized. Descriptive statistics were generated for all variables. “Failure” was defined as occurrence of a dislocation. “Recurrent instability” was defined as the participant reporting a dislocation or two or more occurences of subluxation greater than one year post-operative. All analyses were undertaken based on intention-to-treat whereby their data was analyzed based on the group to which they were originally allocated. One-hundred and eight participants were randomized of which 50 in the NO REMP group and 52 in the REMP group were included in the analyses in the original study. The mean number of months from surgery to final follow-up was 49.3 for the NO REMP group and 53.8 for the REMP group. The rates of re-dislocation or failure were 8% (4/52) in the REMP group at an average of 23.8 months post-operative versus 22% (11/50) in the NO REMP at an average of 16.5 months post-operative. The rates of recurrent instability were 10% (5/52) in the REMP group at an average of 24 months post-operative versus 30% (15/50) in the NO REMP group at an average of 19.5 months post-operative. Survival curves were significantly different favouring REMP in both scenarios. Arthroscopic Bankart repair combined with remplissage is an effective procedure in the treatment of patients with an engaging Hill-Sachs lesion and minimal glenoid bone loss (<15%). Patients can expect favourable rates of recurrent instability when compared with isolated Bankart repair at medium term follw-up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 56 - 56
1 Aug 2020
Stockton DJ Tobias G Pike J Daneshvar P Goetz TJ
Full Access

Compared to single-incision distal biceps repair (SI), double-incision repair (DI) theoretically allows for reattachment of the tendon to a more anatomically favorable position. We hypothesized that DI repair would result in greater terminal supination torque compared to SI repair for acute distal biceps ruptures. In this retrospective cohort study, patients were included if they sustained an isolated, acute (° supinated position. Secondary outcomes included supination torque in 45° supinated, neutral, and 45° pronated positions, ASES elbow score, DASH, SF-12, and VAS. Power analysis revealed that at least 32 patients were needed to detect a minimum 15% difference in the primary outcome (β = 0.20). Statistical analysis was performed with significance level α = 0.05 using R version 3.4.1 (R Core Team 2017, Vienna, Austria). Of 53 eligible patients, 37 consented to participate. Fifteen were repaired using DI technique and 22 using SI technique. Mean age was 47.3yrs and median follow-up time was 28.1months. The groups did not differ with respect to age, time-to-follow-up, dominance of arm affected, Workers Compensation or smoking status. Mean supination torque, measured as the percentage of the unaffected side, was 60.9% (95%CI 45.1–76.7) for DI repair versus 80.4% (95%CI 69.1–91.7) for SI repair at the 60°supinated position (p=0.036). There were no statistically significant differences in mean supination torque at the 45°supinated position: 67.1% (95%CI 49.4–84.7) for DI versus 81.8% (95%CI 72.2–91.4) for SI (p=0.102), at the neutral position: 88.8% (95%CI 75.2–102.4) for DI versus 97.6% (95%CI 91.6–103.7) for SI (p=0.0.170), and at the 45°pronated position: 104.5% (95%CI 91.1–117.9) for DI versus 103.4 (95%CI 97.2–109.6) for SI (p=0.0.862). No statistically significant differences were detected in the secondary outcomes ASES Pain, ASES Function, DASH scores, SF-12 PCS or MCS, or VAS Pain. A small difference was detected in VAS Function (median 1.3 for DI repair versus 0.5 for SI repair, p=0.023). In a multivariate linear regression model controlling for arm dominance, age, and follow-up time, SI repair was associated with a greater mean supination torque than DI repair by 19.6% at the 60°supinated position (p=0.011). Contrary to our hypothesis, we found approximately a 20% mean improvement in terminal supination torque for acute distal biceps ruptures repaired with the single-incision technique compared to the double-incision technique. Patients uniformly did well with either technique, though we contend that this finding may have clinical significance for the more discerning, high-demand patient


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 58 - 58
1 Jul 2020
Stockton DJ Tobias G Pike J Daneshvar P Goetz TJ
Full Access

Compared to single-incision distal biceps repair (SI), double-incision repair (DI) theoretically allows for reattachment of the tendon to a more anatomically favorable position. We hypothesized that DI repair would result in greater terminal supination torque compared to SI repair for acute distal biceps ruptures. In this retrospective cohort study, patients were included if they sustained an isolated, acute (° supinated position. Secondary outcomes included supination torque in 45° supinated, neutral, and 45° pronated positions, ASES elbow score, DASH, SF-12, and VAS. Power analysis revealed that at least 32 patients were needed to detect a minimum 15% difference in the primary outcome (β = 0.20). Statistical analysis was performed with significance level α = 0.05 using R version 3.4.1 (R Core Team 2017, Vienna, Austria). Of 53 eligible patients, 37 consented to participate. Fifteen were repaired using DI technique and 22 using SI technique. Mean age was 47.3yrs and median follow-up time was 28.1months. The groups did not differ with respect to age, time-to-follow-up, dominance of arm affected, Workers Compensation or smoking status. Mean supination torque, measured as the percentage of the unaffected side, was 60.9% (95%CI 45.1–76.7) for DI repair versus 80.4% (95%CI 69.1–91.7) for SI repair at the 60°supinated position (p=0.036). There were no statistically significant differences in mean supination torque at the 45°supinated position: 67.1% (95%CI 49.4–84.7) for DI versus 81.8% (95%CI 72.2–91.4) for SI (p=0.102), at the neutral position: 88.8% (95%CI 75.2–102.4) for DI versus 97.6% (95%CI 91.6–103.7) for SI (p=0.0.170), and at the 45°pronated position: 104.5% (95%CI 91.1–117.9) for DI versus 103.4 (95%CI 97.2–109.6) for SI (p=0.0.862). No statistically significant differences were detected in the secondary outcomes ASES Pain, ASES Function, DASH scores, SF-12 PCS or MCS, or VAS Pain. A small difference was detected in VAS Function (median 1.3 for DI repair versus 0.5 for SI repair, p=0.023). In a multivariate linear regression model controlling for arm dominance, age, and follow-up time, SI repair was associated with a greater mean supination torque than DI repair by 19.6% at the 60°supinated position (p=0.011). Contrary to our hypothesis, we found approximately a 20% mean improvement in terminal supination torque for acute distal biceps ruptures repaired with the single-incision technique compared to the double-incision technique. Patients uniformly did well with either technique, though we contend that this finding may have clinical significance for the more discerning, high-demand patient


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 103 - 103
1 Jul 2020
Peck J Pincus D Wasserstein D Kreder H Henry P
Full Access

Rotator cuff repair (RCR) can be performed open or arthroscopically, with a recent dramatic increase in the latter. Despite controversy about the preferred technique, there has been an increase in the number of repairs performed arthroscopically. The purpose of this study was, therefore, to compare revision rates following open and arthroscopic RCR repair. Adult patients undergoing first-time, primary rotator cuff repair in Ontario, Canada (April 2003-March 2014) were identified using physician billing and hospital databases. Patients were followed for a minimum of two and up to 13 years for the primary outcome, revision rotator cuff repair, and secondary outcome, surgical site infection. The intervention considered was open versus arthroscopic technique. Patient factors (age, gender, residence, socioeconomic status, medical comorbidities) and provider factors (surgical volume, hospital setting, worked night before, year of surgery) were recorded. Standardized mean differences were used for covariate comparison. A Cox Proportional Hazards model was used to compare RCR survivorship between the two groups after adjustment for patient and provider factors, generating hazard ratios with 95% confidence intervals (HR, 95% CIs). Censoring occurred on the first of the primary outcome, death, shoulder arthroplasty or arthrodesis, or the end of the follow-up period (March 2016). A total of 37,255 patients were included. The overall revision RCR rate was 2.9% (1,096 patients) with a median time to revision of 23 months (IQR 12–52). Revision repair was more common in the arthroscopic group in comparison to the open group (3.2% vs 2.6%, NNT 166.7, p=0.004), with an adjusted HR of 0.72 (0.63–0.83 95% CI, p < 0 .0001). The surgical site infection rate was significantly higher in the open group compared with the arthroscopic group (0.5% vs 0.2%, NNT 333.3, p < 0 .001). Patient and provider covariates had no statistically significant effect on revision rates, aside from increasing age (per 10 year increase, HR 0.85, 0.81–0.90 95% CI, p < 0 .0001). Revision rotator cuff repair is approximately 30% more common in patients undergoing arthroscopic repair, in comparison to open repair, after adjustment. Surgical site infection is uncommon regardless of surgical technique, however, it is slightly more common following open repair. In the setting of an economic healthcare crisis, trends of increasing arthroscopic RCR may demand scrutiny, as the technique is associated with higher revision rates and higher costs


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1419 - 1427
3 Oct 2020
Wood D French SR Munir S Kaila R

Aims. Despite the increase in the surgical repair of proximal hamstring tears, there exists a lack of consensus in the optimal timing for surgery. There is also disagreement on how partial tears managed surgically compare with complete tears repaired surgically. This study aims to compare the mid-term functional outcomes in, and operating time required for, complete and partial proximal hamstring avulsions, that are repaired both acutely and chronically. Methods. This is a prospective series of 156 proximal hamstring surgical repairs, with a mean age of 48.9 years (21.5 to 78). Functional outcomes were assessed preinjury, preoperatively, and postoperatively (six months and minimum three years) using the Sydney Hamstring Origin Rupture Evaluation (SHORE) score. Operating time was recorded for every patient. Results. Overall, significant improvements in SHORE scores were seen at both six months and mid-term follow-up. Preoperatively, acute patients (median score 27.1 (interquartile range (IQR) 22.9)) reported significantly poorer SHORE scores than chronic patients (median score 42.9 (IQR 22.1); p < 0.001). However, this difference was not maintained postoperatively. For partial tears, acutely repaired patients reported significantly lower preoperative SHORE scores compared to chronically reapired partial tears (median score 24.3 (IQR 15.7) vs median score 40.0 (IQR 25.0); p < 0.001) but also significantly higher SHORE scores at six-month follow-up compared to chronically repaired partial tears (median score 92.9 (IQR 10.7) vs. median score 82.9 (IQR 14.3); p < 0.001). For complete tears, there was only a difference in preoperative SHORE scores between acute and chronic groups. Overall, acute repairs had a significantly shorter operating time (mean 64.67 minutes (standard deviation (SD) 12.99)) compared to chronic repairs (mean 74.71 minutes (SD = 12.0); t = 5.12, p < 0.001). Conclusion. Surgical repair of proximal hamstring avulsions successfully improves patient reported functional outcomes in the majority of patients, irrespective of the timing of their surgery or injury classification. However, reducing the time from injury to surgery is associated with greater improvement in patient outcomes and an increased likelihood of returning to preinjury functional status. Acute repair appears to be a technically less complex procedure, as indicated by reduced operating times, postoperative neurological symptoms and number of patients requiring bracing. Acute repair is therefore a preference among many surgeons. Cite this article: Bone Joint J 2020;102-B(10):1419–1427


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 50 - 50
1 Apr 2018
Kim Y Kim Y Hwang K Moon J
Full Access

Purpose. The posterolateral or posterior approach for total hip arthroplasty has the advantages of preserving the hip abductor musculature and providing good visualization during femoral preparation and component insertion. Although posterolateral approach is one of the popular approaches in hip arthroplasty, it has been reported high dislocation rate as a drawback. To compensate the drawback the repair of short external rotator of hip is thought to be important. Therefore, we investigated incidence of failed repaired short external rotator muscles, dislocation rate and time of failure between tendon to tendon and tendon to bone repair technique through prospective study more than 1 year follow up. Materials and methods. We performed 213 hip arthroplasties in 202 patients from May 2012 to January 2015. After exclusion of 15 hips due to follow-up loss(9 hips), death(2 hips), greater trochanteric fragment displacement(3 hips) and severe contracted short external rotator(1 hip), we investigated 198 hips in 187 patients. 57 patients were male and 130 patients were female. The mean age of patient was 70.4 (32–98) years. Reattachment short external rotator with posterior capsule to postero-superior aspect of greater trochanter(tendon to bone group, 111 hips) or to the tendon(tendon to tendon group, 87 hips) was performed. Two No.26 metal wire markers were fixed at the greater trochanter tip and short external rotator tendon respectively with a distance less than 1.2cm, and the distance between two wire markers was observed at postoperative 1 day, 2 weeks, 3 months, and annually radiographs in neutral position. When the distance was more than 2.5cm or one of the wire markers was invisible, we defined them the failure of short external rotator repair. The mean follow up period was 28.8 (12–45) months. Results. Failure rate of tendon to bone repair technique(17.1%) was significantly less as compared to that of tendon to tendon repair technique(70.1%)(p<0.001). The failure of short external rotator repair happened mostly within postoperative 2 weeks, which was 89.5% in tendon to bone(p=0.025) and 93.4% in tendon to tendon repair (p<0.001). Dislocation was observed in 2 (1.8%) hips in tendon to bone repair group and in 7 (8.0%) hips in tendon to tendon repair group respectively, which was significantly higher dislocation rate in tendon to tendon repair group. A significant correlation was also observed between failure of short external rotator repair and dislocation (p=0.032). Conclusions. Tendon to bone repair technique is superior to tendon to tendon technique in terms of failure rate of short external rotator repair in hip arthroplasty. Tendon to bone repair of short external rotator with posterior capsule was beneficial to reduce dislocation rate as compared with tendon to tendon repair technique. As majority of failure of short external rotator happened within postoperative 2 weeks, restriction of internal rotation should be recommended through the period


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 83 - 83
23 Feb 2023
Rossignol SL Boekel P Grant A Doma K Morse L
Full Access

Currently, the consensus regarding subscapularis tendon repair during a reverse total shoulder arthroplasty (rTSA) is to do so if it is possible. Repair is thought to decrease the risk of dislocation and improve internal rotation but may also increase stiffness and improvement in internal rotation may be of subclinical benefit. Aim is to retrospectively evaluate the outcomes of rTSA, with or without a subscapularis tendon repair. We completed a retrospective review of 51 participants (25 without and 26 with subscapularis repair) who received rTSR by a single-surgeon using a single-implant. Three patient reported outcome measures (PROM) were assessed pre-operatively and post-operative at twelve months, as well as range of movement (ROM) and plain radiographs. Statistical analysis utilized unpaired t tests for parametric variables and Mann-Whitney U test for nonparametric variables. External Rotation ROM pre-operatively was the only variable with a significance difference (p=0.02) with the subscapularis tendon repaired group having a greater range. Pre- and post-operative abduction (p=0.72 & 0.58), forward flexion (p=0.67 & 0.34), ASES (p=0.0.06 & 0.78), Oxford (p=0.0.27 & 0.73) and post-operative external rotation (p=0.17). Greater external rotation ROM pre-operatively may be indicative of the ability to repair the subscapularis tendon intra-operatively. However, repair does not seem to improve clinical outcome at 12 months. There was no difference of the PROMs and AROMs between the subscapularis repaired and not repaired groups for any of the variables at the pre-operative or 12 month post operative with the exception of the external rotation ROM pre-operatively. We can conclude that from PROM or AROM perspective there is no difference if the tendon is repaired or not in a rTSR and indeed the patients without the repair may have improved outcomes at 12 months


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 80 - 80
23 Feb 2023
Bolam S Park Y Konar S Callon K Workman J Monk A Coleman B Cornish J Vickers M Munro J Musson D
Full Access

We hypothesised that diet-induced obesity (DIO) would result in inferior enthesis healing in a rat model of rotator cuff (RC) repair and that dietary intervention in the peri-operative period would improve enthesis healing. A total of 78 male Sprague-Dawley rats were divided into three weight-matched groups from weaning and fed either: control diet (CD), high-fat diet (HFD), or HFD until surgery, then CD thereafter (HF-CD). After 12 weeks, the left supraspinatus tendon was detached, followed by immediate surgical repair. At 2 and 12 weeks post-surgery, animals were culled, and RCs harvested for biomechanical and histological evaluation. Body composition and metabolic markers were assessed via DEXA and plasma analyses, respectively. DIO was established in the HFD and HF-CD groups before surgery and subsequently reversed in the HF-CD group after surgery. Histologically, the appearance of the repaired entheses was poorer in both the HFD and HF-CD groups compared with the CD group at 12 weeks after surgery, with semiquantitative scores of 6.2 (P<0.01), 4.98 (P<0.01), and 8.7 of 15, respectively. The repaired entheses in the HF-CD group had a significantly lower load to failure (P=0.03) at 12 weeks after surgery compared with the CD group, while the load to failure in the HFD group was low but not significantly different (P=0.10). Plasma leptin were negatively correlated with histology scores and load to failure at 12 weeks after surgery. DIO impaired enthesis healing in this rat RC repair model, with inferior biomechanical and histological outcomes. Restoring normal weight with dietary change after surgery did not improve healing outcomes. Circulating levels of leptin significantly correlated with poor healing outcomes. This pre-clinical rodent model demonstrates that obesity is a potentially modifiable factor that impairs RC healing and increases the risk of failure after RC surgery


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 72 - 72
1 Dec 2022
Lamer S Ma Z Mazy D Chung-Tze-Cheong C Nguyen A Li J Nault M
Full Access

Meniscal tears are the most common knee injuries, occurring in acute ruptures or in chronic degenerative conditions. Meniscectomy and meniscal repair are two surgical treatment options. Meniscectomy is easier, faster, and the patient can return to their normal activities earlier. However, this procedure has long-term consequences in the development of degenerative changes in the knee, potentially leading to knee replacement. On the other hand, meniscal repair can offer prolonged benefits to the patients, but it is difficult to perform and requires longer rehabilitation. Sutures are used for meniscal repairs, but they have limitations. They induce tissue damage when passing through the meniscus. Furthermore, under dynamic loading of the knee, they can cause tissue shearing and potentially lead to meniscal repair failure. Our team has developed a new technology of resistant adhesive hydrogels to coat the suture used to repair meniscal tissue. The objective of this study is to biomechanically compare two suture types on bovine menisci specimens: 1) pristine sutures and 2) gel adhesive puncture sealing (GAPS) sutures, on a repaired radial tear under cyclic tensile testing. Five bovine knees were dissected to retrieve the menisci. On the 10 menisci, a complete radial tear was performed. They were separated in two groups and repaired using either pristine (2-0 Vicryl) or GAPS (2-0 Vicryl coated with adhesive hydrogels) with a single stitch and five knots. The repaired menisci were clamped on an Instron machine. The specimens were cyclically preconditioned between one and 10 newtons for 10 cycles and then cyclically loaded for 500 cycles between five and 25 newtons at a frequency of 0.16 Hz. The gap formed between the edges of the tear after 500 cycles was then measured using an electronic measurement device. The suture loop before and after testing was also measured to ensure that there was no suture elongation or loosening of the knot. The groups were compared statistically using Mann-Whitney tests for nonparametric data. The level of significance was set to 0.05. The mean gap formation of the pristine sutures was 5.61 mm (SD = 2.097) after 500 cycles of tensile testing and 2.38 mm (SD = 0.176) for the GAPS sutures. Comparing both groups, the gap formed with the coated sutures was significantly smaller (p = 0.009) than with pristine sutures. The length of the loop was equal before and after loading. Further investigation of tissue damage indicated that the gap was formed by suture filament cutting into the meniscal tissue. The long-term objective of this research is to design a meniscal repair toolbox from which the surgeon can adapt his procedure for each meniscal tear. This preliminary experimentation on bovine menisci is promising because the new GAPS sutures seem to keep the edges of the meniscal tear together better than pristine sutures, with hopes of a clinical correlation with enhanced meniscal healing


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 66 - 66
1 Dec 2022
Lamer S Ma Z Mazy D Chung-Tze-Cheong C Nguyen A Li J Nault M
Full Access

Meniscal tears are the most common knee injuries, occurring in acute ruptures or in chronic degenerative conditions. Meniscectomy and meniscal repair are two surgical treatment options. Meniscectomy is easier, faster, and the patient can return to their normal activities earlier. However, this procedure has long-term consequences in the development of degenerative changes in the knee, potentially leading to knee replacement. On the other hand, meniscal repair can offer prolonged benefits to the patients, but it is difficult to perform and requires longer rehabilitation. Sutures are used for meniscal repairs, but they have limitations. They induce tissue damage when passing through the meniscus. Furthermore, under dynamic loading of the knee, they can cause tissue shearing and potentially lead to meniscal repair failure. Our team has developed a new technology of resistant adhesive hydrogels to coat the suture used to repair meniscal tissue. The objective of this study is to biomechanically compare two suture types on bovine menisci specimens: 1) pristine sutures and 2) gel adhesive puncture sealing (GAPS) sutures, on a repaired radial tear under cyclic tensile testing. Five bovine knees were dissected to retrieve the menisci. On the 10 menisci, a complete radial tear was performed. They were separated in two groups and repaired using either pristine (2-0 Vicryl) or GAPS (2-0 Vicryl coated with adhesive hydrogels) with a single stitch and five knots. The repaired menisci were clamped on an Instron machine. The specimens were cyclically preconditioned between one and 10 newtons for 10 cycles and then cyclically loaded for 500 cycles between five and 25 newtons at a frequency of 0.16 Hz. The gap formed between the edges of the tear after 500 cycles was then measured using an electronic measurement device. The suture loop before and after testing was also measured to ensure that there was no suture elongation or loosening of the knot. The groups were compared statistically using Mann-Whitney tests for nonparametric data. The level of significance was set to 0.05. The mean gap formation of the pristine sutures was 5.61 mm (SD = 2.097) after 500 cycles of tensile testing and 2.38 mm (SD = 0.176) for the GAPS sutures. Comparing both groups, the gap formed with the coated sutures was significantly smaller (p = 0.009) than with pristine sutures. The length of the loop was equal before and after loading. Further investigation of tissue damage indicated that the gap was formed by suture filament cutting into the meniscal tissue. The long-term objective of this research is to design a meniscal repair toolbox from which the surgeon can adapt his procedure for each meniscal tear. This preliminary experimentation on bovine menisci is promising because the new GAPS sutures seem to keep the edges of the meniscal tear together better than pristine sutures, with hopes of a clinical correlation with enhanced meniscal healing


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 8 - 8
23 Jan 2024
Nanjundaiah R Guro R Chandratreya A Kotwal R
Full Access

Aims. We studied the outcomes following arthroscopic primary repair of bucket handle meniscus tears to determine the incidence of re-tears and the functional outcomes of these patients. Methodology. Prospective cohort study. Over a 4-year period (2016 to 2020), 35 adult patients presented with a bucket handle tear of the meniscus. Arthroscopic meniscal repair was performed using either the all inside technique or a combination of all-inside and inside-out techniques. 15 patients also underwent simultaneous arthroscopic anterior cruciate ligament reconstruction. Functional knee scores were assessed using IKDC and Lysholm scores. Results. Mean patient age at surgery was 27 years (range, 17 to 53years). Medial meniscus was torn in 20 and lateral in 15 cases. Zone of tear was white on white in 19, red on white in 9 and red on red in 7 cases. Average delay from injury to surgery was 4 months. At a mean follow-up of 4.5 years, the meniscus repair failed in 3 patients (8.5 %). Outcome following re-tear was meniscus excision. Average IKDC scores in patients with intact repair were 74.04 against 56.67 in patients with a failed repair (p< 0.0001). Similarly, Lyshlom scores were 88.96 and 67.333, respectively (p<0.0001). Conclusion. The survivorship of primary repair of bucket handle meniscus tears in our series was 91.5% at medium term follow-up. Functional outcomes were significantly poor in patients with a failed repair compared to those with an intact repair


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 19 - 19
1 Nov 2022
Agrawal P Gilbert R
Full Access

Abstract. Ramp lesions are meniscocapsular or meniscosynovial tears associated with chronic ACL injury and are postulated to occur because of disruption of meniscotibial ligament. Various techniques have been described in literature for their diagnosis and repair. Each of the described techniques have had some concerns. The authors, hereby, describe a novel technique for RAMP repair. Our Technique. Patient is positioned supine with the knee at 90 degrees with a side support. Standard arthroscopic portals are established. Ramp lesions are visualised through a trans-notch approach and probed simultaneously using an 18-guage needle posteromedialy. Once the diagnosis has been confirmed a posteromedial (PM) portal is established. The edges of the tear are freshened from the PM portal using a shaver or rasp. Knee Scorpion device (Arthrex) is then introduced through the PM which is loaded with No. 0 Fibrewire (Arthrex) in its lower jaw. The Scorpion device is deployed on the capsular side first, avoiding injury to the posterior structures and the suture loop is retrieved. Scorpion is loaded again with the other strand and is passed through the meniscal edge. A sliding knot is used. Ramp lesion is re-probed after tying a sliding knot for requirement of another suture. This technique provides us with an improved visualisation and diagnosis, better quality of debridement and complete closure of the ramp lesion using a simple suture device. In our experience this is a safe, successful and easily reproducible technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 72 - 72
10 Feb 2023
Hollman, F Mohammad J Singh N Gupta A Cutbush K
Full Access

Acromioclavicular joint (ACJ) dislocations is a common disorder amongst our population for which numerous techniques have been described. It is thought that by using this novel technique combining a CC and AC repair with a reconstruction will result in high maintenance of anatomical reduction and functional results. 12 consecutive patients ACJ dislocations were included. An open superior clavicular approach is used. Firstly, the CC ligaments are repaired after which a CC reconstruction is performed using a tendon allograft. Secondly, the AC ligaments are repaired using an internal brace construct combined with a tendon allograft reconstruction (Figure 1). The acute:chronic ratio was 6:6. Only IIIB, IV and V AC-joint dislocations were included. The Constant-Murley Score improved from 27.6 (8.0 – 56.5) up to 61.5 (42.0 – 92.0) at 12 months of follow up. Besides one frozen shoulder from which the patient recovered spontaneously no complications were observed with this technique. The CCD was reduced from 18.7 mm (13.0 – 24.0) to 10.0 mm (6.0 – 16.0) and 10.5 mm (8.0 – 14.0) respectively 12 weeks and 12 months postoperatively. There is some evidence, suggesting to address as well as the vertical (coracoclavicular (CC) ligaments) as the horizontal (acromioclavicular (AC) ligaments) direction of instability. This study supports addressing both entities however comparative studies discriminating chronic as acute cases should be conducted to further clarify this ongoing debate on treating ACJ instability. This study describes a novel technique to treat acute and chronic Rockwood stage IIIB – IV ACJ dislocations with promising short-term clinical and radiological results. This suggests that the combined repair and reconstruction of the AC and CC ligaments is a safe procedure with low complication risk in experienced hands. Addressing the vertical as well as horizontal stability in ACJ dislocation is considered key to accomplish optimal long-term results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 65 - 65
23 Feb 2023
Ting R Rosenthal R Shin Y Shenouda M Al-Housni H Lam P Murrell G
Full Access

It is undetermined which factors predict return to work following arthroscopic rotator cuff repair. We aimed to identify which factors predicted return to work at any level, and return to pre-injury levels of work 6 months post-arthroscopic rotator cuff repair. Multiple logistic regression analysis of prospectively collected demographic, pre-injury, preoperative, and intraoperative data from 1502 consecutive primary arthroscopic rotator cuff repairs, performed by a single surgeon, was performed to identify independent predictors of return to work, and return to pre-injury levels of work respectively, 6 months post-surgery. Six months post-rotator cuff repair, 76% of patients returned to work (RTW), and 40% returned to pre-injury levels of work (Full-RTW). RTW at 6 months was likely if patients were still working after their injuries, but prior to surgery (Wald statistic [W]=55, p<0.0001), were stronger in internal rotation preoperatively (W=8, p=0.004), had full-thickness tears (W=9, p=0.002), and were female (W=5, p=0.030). Patients who achieved Full-RTW were likely to have worked less strenuously pre-injury (W=173, p<0.0001), worked more strenuously post-injury but pre-surgery (W=22, p<0.0001), had greater behind-the-back lift-off strength preoperatively (W=8, p=0.004), and had less passive external rotation range of motion preoperatively (W=5, p=0.034). Patients who were still working post-injury, but pre-surgery were 1.6-times more likely to RTW than patients who were not (p<0.0001). Patients who nominated their pre-injury level of work as “light” were 11-times more likely to achieve Full-RTW than those who nominated “strenuous” (p<0.0001). Six months post-rotator cuff repair, a higher patient-rated post-injury, but pre-surgery level of work was the strongest predictor of RTW. A lower patient-rated pre-injury level of work was the strongest predictor of Full-RTW. Greater preoperative subscapularis strength independently predicted both RTW, and Full-RTW


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 26 - 26
1 Dec 2022
Lapner P Pollock J Hodgdon T Zhang T McIlquham K Coupal S Bouliane M McRae S Dubberley J Berdusco R Stranges G Marsh J Old J MacDonald PB
Full Access

Our primary objective was to compare healing rates in patients undergoing arthroscopic rotator cuff repair for degenerative tears, with and without bone channeling. Our secondary objectives were to compare disease-specific quality of life and patient reported outcomes as measured by the Western Ontario Rotator Cuff Index (WORC), American Shoulder and Elbow Surgeons (ASES) score and Constant score between groups. Patients undergoing arthroscopic rotator cuff repair at three sites were randomized to receive either bone channeling augmentation or standard repair. Healing rates were determined by ultrasound at 6 and 24 months post operatively. WORC, ASES, and Constant scores were compared between groups at baseline and at 3, 6, 12 and 24 months post operatively. One hundred sixty-eight patients were recruited and randomized between 2013 to 2018. Statistically significant improvements occurred in both groups from pre-operative to all time points in all clinical outcome scores (p < 0 .0001). Intention to treat analysis revealed no statistical differences in healing rates between the two interventions at 24 months post-operative. No differences were observed in WORC, ASES or Constant scores at any time-point. This trial did not demonstrate superiority of intra-operative bone channeling in rotator cuff repair surgery at 24 months post-operative. Healing rates and patient-reported function and quality of life measures were similar between groups


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 38 - 38
23 Feb 2023
Ernstbrunner L Almond M Rupasinghe H Jo O Zbeda R Ackland D Ek E
Full Access

The extracortical single-button (SB) inlay repair is one of the most preferred distal biceps tendon repair techniques. However, specific complications such as neurovascular injury and non-anatomic repairs have led to the development of techniques that utilize intracortical double-button (DB) fixation. To compare the biomechanical stability of the extracortical SB repair with the anatomical DB repair technique. Controlled laboratory study. The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SBor anatomical DB group. Both groups were cyclically loaded with 60N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap-formation and construct stiffness during cyclic loading, and ultimate load to failure was analysed. After 1000 cycles, the anatomical DB technique compared with the extracortical SB technique showed significantly less gap-formation (mean difference 1.2 mm; p=0.017) and significantly more construct stiffness (mean difference 31 N/mm; p=0.023). Ultimate load to failure was not significantly different comparing both groups (SB, 277 N ±92 vs. DB, 285 N ±135; p=0.859). The failure mode in the anatomical DB group was significantly different compared with the extracortical SB technique (p=0.002) and was due to fracture avulsion of the BicepsButton in 7 out of 9 specimens (vs. none in SB group). Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to the SB technique. The DB repair technique reduces the risk of nerve injury and better restores the anatomical footprint of biceps tendon. The DB technique may offer a clinically viable alternative to the SB repair technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 31 - 31
1 Nov 2022
Ahmed N Norris R Bindumadhavan S Sharma A
Full Access

Abstract. Background. We know that tears of the Triangular fibrocartilage complex (TFCC) can cause DRUJ instability and ulnar sided wrist pain. This study shows the clinical result of patients who had arthroscopic transosseous repair of the TFCC tear with DRUJ instability. Arthroscopic repair of TFCC tear is a promising, minimally invasive surgical technique especially in patients with DRUJ instability. Materials and methods. Fifteen patients who underwent TFCC one tunnel repair form 2018–2021 were reviewed retrospectively in hospital. The proximal component of TFCC was repaired through arthroscopic one- tunnel transosseous suture technique. VAS score for pain, wrist range of motion, grip strength and post operative complications were evaluated and each patient was rated according to the DASH score. Results. The patients had a TFCC tear confirmed on MRI and was confirmed on arthroscopy by doing a hook test. The patients were followed up for 6 months. Twelve patients had normal stability of DRUJ and three patients showed mild laxity compared with the contralateral side. The mean VAS score reduced from 4.7 to 0.8 (P=0.001) and grip strength increased significantly. The quick DASH score (P=0.001)also showed significant functional improvement. No surgical related complications occurred. Conclusions. Arthroscopic one tunnel transosseous TFCC foveal repair can be an excellent and safe method for repair of TFCC tear with DRUJ instability. Its a good treatment option in terms of reliable pain relief, functional improvement and reestablishment of DRUJ stability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 91 - 91
23 Feb 2023
Cecchi S Aujla R Edwards P Ebert J Annear P Ricciardo B D'Alessandro P
Full Access

Avulsion of the proximal hamstring tendon from the ischial tuberosity is an uncommon but significant injury. Recent literature has highlighted that functional results are superior with surgical repair over non-surgical treatment. Limited data exists regarding the optimal rehabilitation regime in post-operative patients. The aim of this study was to investigate the early interim patient outcomes following repair of proximal hamstring tendon avulsions between a traditionally conservative versus an accelerated rehabilitation regimen. In this prospective randomised controlled trial (RCT) 50 patients underwent proximal hamstring tendon avulsion repair, and were randomised to either a braced, partial weight-bearing (PWB) rehabilitation regime (CR = 25) or an accelerated, unbraced, immediate full weight-bearing (FWB) regime (AR group; n = 25). Patients were evaluated preoperatively and at 3 months after surgery, using the Lower Extremity Functional Scale (LEFS), Perth Hamstring Assessment Tool (PHAT), visual analog pain scale (VASP), Tegner score, and 12-item Short Survey Form (SF-12). Patients also filled in a diary questioning postoperative pain at rest from Day 2, until week 6 after surgery. Primary analysis was by per protocol and based on linear mixed models. Both groups, with respect to patient and characteristics were matched at baseline. Over three months, five complications were reported (AR = 3, CR = 2). At 3 months post-surgery, significant improvements (p<0.001) were observed in both groups for all outcomes except the SF-12 MCS (P = 0.623) and the Tegner (P = 0.119). There were no significant between-group differences from baseline to 3 months for any outcomes, except for the SF-12 PCS, which showed significant effects favouring the AR regime (effect size [ES], 0.76; 95% CI, 1.2-13.2; P = .02). Early outcomes in an accelerated rehabilitation regimen following surgical repair of proximal hamstring tendon avulsions, was comparable to a traditionally conservative rehabilitation pathway, and resulted in better physical health-related quality of life scores at 3 months post-surgery. Further long term follow up and functional assessment planned as part of this study


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 219 - 219
1 Sep 2012
Wilson J Robinson P Norburn P Roy B
Full Access

The indication for rotator cuff repair in elderly patients is controversial. Methods. Consecutive patients over the age of 70 years, under the care of a single surgeon, receiving an arthroscopic rotator cuff repair were reviewed. Predominantly, a single row repair was performed using one (34 cases) or two (30) 5mm Fastin, double-loaded anchors. Double-row repair was performed in four cases. Subacromial decompression and treatment of biceps pathology were performed as necessary. Data were collected from medical records, digital radiology archives and during clinic appointments. Pain, motion, strength and function were quantified with the Constant-Murley Shoulder Outcome Score, administered pre operatively and at 1-year post operatively. Ultrasound scans were performed at one year to document integrity of the repair. Results. Sixty-nine arthroscopic cuff repairs were identified in 68 patients. The mean age was 77 years (70–86). The median ASA grade was 2 (79%). The dominant side was operated on in 68% of cases. A range of tear sizes were operated on (5 small, 17 moderate, 29 large and 18 massive). The tendons involved in the tear also varied (supraspinatus 12, supra and infraspinatus 53, supraspinatus and subscapularis 2, supraspinatus infraspinatus and subscapularis 2). Re-rupture occurred in 20 cases (29%). The mean Constant score increased from 23 (95% CI 19–26) to 59 (54–64) (P< 0.001). Where the repair remained sound, Constant score improved 42 points (95%CI 36–48). If the cuff re-ruptured, constant score also increased on average 12 points (95% CI 2–21). Re-rupture rate was highest for massive cuff repairs: ten out of eighteen (56%). Conclusion. Arthroscopic rotator cuff repair in the elderly is a successful procedure. Approximately seven out of ten repairs remained intact after one year. Even where re-rupture occurs, a significant improvement in the Constant score was found


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 57 - 57
1 Jul 2020
Chevrier A Hurtig M Lacasse F Lavertu M Potter H Pownder S Rodeo S Buschmann M
Full Access

Surgical reattachment of torn rotator cuff tendons can lead to satisfactory clinical outcome but failures remain common. Ortho-R product is a freeze-dried formulation of chitosan (CS) that is solubilized in platelet-rich plasma (PRP) to form injectable implants. The purpose of the current pilot study was to determine Ortho-R implant acute residency, test safety of different implant doses, and assess efficacy over standard of care in a sheep model. The infraspinatus tendon (ISP) was detached and immediately repaired in 22 skeletally mature ewes. Repair was done with four suture anchors in a suture bridge configuration (n = 6 controls). Freeze-dried formulations containing 1% w/v chitosan (number average molar mass 35 kDa and degree of deacetylation 83%) with 1% w/v trehalose (as lyoprotectant) and 42.2 mM calcium chloride (as clot activator) were solubilized with autologous leukocyte-rich PRP and injected at the tendon-bone interface and on top of the repaired site (n = 6 with a 1 mL dose and n = 6 with a 2 mL dose). Acute implant residency was assessed histologically at 1 day (n = 2 with a 1 mL dose and n = 2 with a 2 mL dose). Outcome measures included MRI assessment at baseline, 6 weeks and 12 weeks, histopathology at 12 weeks and clinical pathology. MRI images and histological slides were scored by 2 blinded readers (veterinarian and human radiologist, and veterinarian pathologist) and averaged. The Generalized Linear Model task (SAS Enterprise Guide 7.1 and SAS 9.4) was used to compare the different groups with post-hoc analysis to test for pairwise differences. Ortho-R implants were detected near the enthesis, near the top of the anchors holes and at the surface of ISP tendon and muscle at 1 day. Numerous polymorphonuclear cells were recruited to the implant in the case of ISP tendon and muscle. On MRI, all repair sites were hyperintense compared to normal tendon at 6 weeks and only 1 out 18 repair sites was isointense at 12 weeks. The tendon repair site gap seen on MRI, which is the length of the hyperintense region between the greater tuberosity and tendon with normal signal intensity, was decreased by treatment with the 2 mL dose when compared to control at 12 weeks (p = 0.01). Histologically, none of the repair sites were structurally normal. A trend of improved structural organization of the tendon (p = 0.06) and improved structural appearance of the enthesis (p = 0.1) with 2 mL dose treatment compared to control was seen at 12 weeks. There was no treatment-specific effect on all standard safety outcome measures, which suggests high safety. Ortho-R implants (2 mL dose) modulated the rotator cuff healing processes in this large animal model. The promising MRI and histological findings may translate into improved mechanical performance, which will be assessed in a future study with a larger number of animals. This study provides preliminary evidence on the safety and efficacy of Ortho-R implants in a large animal model that could potentially be translated to a clinical setting