Abstract. Introduction. Component mal-positioning in total hip replacement (THR) and total knee replacement (TKR) can increase the risk of revision for various reasons. Compared to conventional surgery, relatively improved accuracy of implant positioning can be achieved using computer assisted technologies including navigation, patient-specific jigs, and robotic systems. However, it is not known whether application of these technologies has improved prosthesis survival in the real-world. This study aimed to compare risk of revision for all-causes following primary THR and TKR, and revision for dislocation following primary THR performed using computer assisted technologies compared to conventional technique. Methods. We performed an observational study using National Joint
This was a retrospective study of
Abstract. INTRODUCTION. In the NHS the structure of a “regular healthcare team” is no longer the case. The NHS is facing a workforce crisis where cross-covering of ward-based health professionals is at an all-time high, this includes nurses, doctors, therapists, pharmacists and clerks. Comprehensive post-operative care documentation is essential to maintain patient safety, reduce information clarification requests, delays in rehabilitation, treatment, and investigations. The value of complete surgical
Abstract. Purpose. Clinical registries are an important aspect of orthopaedic research in assessing the outcomes of surgical intervention and track medical devices. This study aimed to explore the research methodology available to account for patients lost to follow-up (LTFU) specifically in studies related to arthroscopic intervention and whether the rates of patient LTFU are within the acceptable margins for survey studies. Methods. A scoping review, where a literature search for studies from nine arthroscopy registries, was performed on EMBASE, MEDLINE, and the annual reports of each registry. Inclusion criteria included studies with information on patient-reported outcome measures and being based on nine national registries identified. Exclusion criteria included review articles, conference abstracts, studies not based on
Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since
Objectives. The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide.
Background. Since it's establishment in 2007, the National Hip Fracture Database [NHFD] has been the key driving force in improving care for hip fracture patients across the UK. It has facilitated the setting of standards to which all musculoskeletal units are held, and guides service development to optimise outcomes in this group of patients. As with any audit, the ability to draw conclusions and make recommendations for changes in practise relies on the accuracy of data collection. This project aimed to scrutinise the data submitted to the NHFD from a Major Trauma Centre [MTC], focusing on procedure coding, and discuss the implications of any inaccuracies. Method. The authors performed a retrospective analysis of all procedure coding data entered into the NHFD from July 2009 to July 2014 at Cambridge University Hospitals NHS Foundation Trust. We examined 1978 cases for discrepancies, comparing procedure codes entered into the NHFD with post-procedure imaging and operative notes. Results. The procedure coding data submitted to the NHFD was highly inaccurate, with incorrect procedure codes in 24% of the 1978 cases reviewed. In particular, coding of cemented total arthroplasty and cemented bipolar hemiarthroplasty, with coding errors in
Background. Over 96% of primary total hip replacements (THR) recorded in the National Joint Registry (NJR) are performed through a posterior or lateral surgical approach. There is no high quality evidence available to support the use of one approach over the other in primary THR and even less evidence when the outcome of revision THR is considered. Methods. Questionnaires were sent to 267 patients who had revision hip replacements between January 2006 and March 2010 for aseptic loosening. They rated their pain from 0–10, and used the Self-Administered Patient Satisfaction Scale (SAPS), Oxford Hip Score (OHS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC) and Short form-12 (SF-12). Results. We performed 275 revision total hip replacements for aseptic loosening on patients in whom the primary operation details were available. Their mean age was 69 years (SD12) with 43% male and 57% right-sided procedures. 205 patients responded to our questionnaires (209/275 hips, 76%). Unfortunately 19 patients had died, 4 had dementia and 13 declined to participate. We were unable to contact a further 33.Grouping by approach, 20% (43/209) had primary and revision lateral approaches, 20% (43/209) had primary lateral and revision posterior and 60% (123/209) had both primary and revision via posterior approaches. The WOMAC and OHS were significantly better in patients who had a posterior approach for both primary and revision surgery, compared to those that did not (OHS p=0.028, WOMAC p=0.026). We found no significant differences in pain, satisfaction or health-related quality of life between the groups. Conclusions.
Summary Statement. For RA patients undergoing TKR, the gain in function at 6 months following surgery is less than that experienced by OA patients; for THR, however, gains are similar in OA and RA patients. Introduction. Total joint replacement (TJR) is commonly used in rheumatoid arthritis (RA) patients and yet little information is available to quantify their functional gain following surgery and how it differs from what the osteoarthritis (OA) population experiences. Therefore, we examined 6-month functional outcomes of TJR in a population-based observational cohort of RA and OA patients who underwent total hip (THR) or knee (TKR) replacement. Methods. Patients undergoing primary TKR from 7/1/11 through 12/3/12 were identified from the FORCE-TJR national research consortium which enrolls patients from 111 surgeons across 27 states in the US. The
A total of 20 pairs of fresh-frozen cadaver femurs were assigned to four alignment groups consisting of relative varus (10° and 20°) and relative valgus (10° and 20°), 75 composite femurs of two neck geometries were also used. In both the cadaver and the composite femurs, placing the component in 20° of valgus resulted in a significant increase in load to failure. Placing the component in 10° of valgus had no appreciable effect on increasing the load to failure except in the composite femurs with varus native femoral necks. Specimens in 10° of varus were significantly weaker than the neutrally-aligned specimens. The results suggest that retention of the intact proximal femoral strength occurs at an implant angulation of ≥ 142°. However, the benefit of extreme valgus alignment may be outweighed in clinical practice by the risk of superior femoral neck notching, which was avoided in this study.