Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 66 - 66
1 Aug 2013
Bell S Brown M Hems T
Full Access

Current knowledge regarding upper limb myotomes is based on historic papers. Recent advances in magnetic resonance imaging (MRI) and surgical exploration with intraoperative nerve stimulation now allow accurate identification of nerve root injuries in the brachial plexus. The aim of this study is to identify the myotome values of the upper limb associated with defined supraclvicular brachial plexus injuries.

57 patients with partial supraclavicular brachial plexus injuries were identified from the Scottish brachial plexus database. The average age was 28 years and most injuries secondary to motor cycle accidents or stabbings. The operative and MRI findings for each patient were checked to establish the root injuries and the muscle powers of the upper limb documented.

The main patterns of injuries identified involved (C5,6), (C5,6,7), (C5,6,7,8) and (C8, T1). C5, 6 injuries were associated with loss of shoulder abduction, external rotation and elbow flexion. In 30% of the 16 cases showed some biceps action from the C7 root. C5,6,7 injuries showed a similar pattern of weakness with the additional loss of flexor carpi radialis and weakness but not total paralysis of triceps in 85% of cases. C5,6,7,8 injuries were characterised by loss of pectoralis major, lattisimus dorsi, triceps, wrist extension, finger extension and as well as weakness of the ulnar intrinsic muscles. We identified weakness of the flexor digitorum profundus to the ulnar sided digits in 83% of cases. T1 has a major input to innervation of flexors of the radial digits and thumb, as well as intrinsics.

This is the largest study of myotome values in patients with surgically or radiologically confirmed injuries in the literature and presents information for general orthopaedic surgeons dealing with trauma patients for the differentiation of different patterns of brachial plexus injuries. In addition we have identified new anatomical relationships not previously described in upper limb myotomes.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 18 - 18
4 Apr 2023
Stanley A Jones G Edwards T Lex J Jaere M
Full Access

Knee pain is common, representing a significant socioeconomic burden. Caused by a variety of pathologies, its evaluation in primary-care is challenging. Subsequently, an over-reliance on magnetic resonance imaging (MRI) exists. Prior to orthopaedic surgeon referral, many patients receive no, or incorrect, imaging. Electronic-triage (e-triage) tools represent an innovative solution to address this problem. The primary aim of this study was to ascertain whether an e-triage tool is capable of outperforming existing clinical pathways to determine the correct pre-hospital imaging based on knee pain diagnosis. Patients ≥18 years with a new presentation of knee pain were retrospectively identified. The timing and appropriateness of imaging was assessed. A symptom-based e-triage tool was developed, using the Amazon LEXbotplatform, and piloted to predict five common knee pathologies and suggest appropriate imaging. 1462 patients were identified. 17% of arthroplasty patients received an ‘unnecessary MRI’, whilst 28% of arthroscopy patients did not have a ‘necessary MRI’, thus requiring a follow-up appointment, with a mean delay of three months (SD 2.6, range 0.2-20.2). Using NHS tariffs, a wasted cost through unnecessary/necessary MRIs and subsequent follow-up appointments was estimated at £45,816. The e-triage pilot was trialled with 41 patients (mean age:58.4 years, 58.5% female). Preliminary diagnoses were available for 34 patients. Using the highest proportion of reported symptoms in the corresponding group, the e-triage tool correctly identified three of the four knee pathologies. The e-triage tool did not correctly identify anterior cruciate ligament injuries (n=3). 79.2% of participants would use the tool again. A significant number of knee pathology patients received incorrect imaging prior to their initial hospital appointment, incurring delays and unnecessary costs. A symptom-based e-triage tool was developed, with promising pilot data and user feedback. With refinement, this tool has the potential to improve wait-times and referral quality, whilst reducing costs


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 105 - 105
14 Nov 2024
Spoo S Garcia F Braun B Cabri J Grimm B
Full Access

Introduction. The objective assessment of shoulder function is important for personalized diagnosis, therapies and evidence-based practice but has been limited by specialized equipment and dedicated movement laboratories. Advances in AI-driven computer vision (CV) using consumer RGB cameras (red-blue-green) and open-source CV models offer the potential for routine clinical use. However, key concepts, evidence, and research gaps have not yet been synthesized to drive clinical translation. This scoping review aims to map related literature. Method. Following the JBI Manual for Evidence Synthesis, a scoping review was conducted on PubMed and Scholar using search terms including “shoulder,” “pose estimation,” “camera”, and others. From 146 initial results, 27 papers focusing on clinical applicability and using consumer cameras were included. Analysis employed a Grounded Theory approach guided iterative refinement. Result. Studies primarily used Microsoft Kinect (infrared-based depth sensing, RGB camera; discontinued) or monocular consumer cameras with open-source CV-models, sometimes supplemented by LiDAR (laser-based depth sensing), wearables or markers. Technical validation studies against gold standards were scarce and too inconsistent for comparison. Larger range of motion (RoM) movements were accurately recorded, but smaller movements, rotations and scapula tracking remained challenging. For instance, one larger validation study comparing shoulder angles during arm raises to a marker-based gold-standard reported Pearson's R = 0.98 and a standard error of 2.4deg. OpenPose and Mediapipe were the most used CV-models. Recent efforts try to improve model performance by training with shoulder specific movements. Conclusion. Low-cost, routine clinical movement analysis to assess shoulder function using consumer cameras and CV seems feasible. It can provide acceptable accuracy for certain movement tasks and larger RoM. Capturing small, hidden or the entirety of shoulder movement requires improvements such as via training models with shoulder specific data or using dual cameras. Technical validation studies require methodological standardization, and clinical validation against established constructs is needed for translation into practice


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 11 - 11
17 Nov 2023
Wahdan Q Solanke F Komperla S Edmonds C Amos L Yap RY Neal A Mallinder N Tomlinson JE Jayasuriya R
Full Access

Abstract. INTRODUCTION. In the NHS the structure of a “regular healthcare team” is no longer the case. The NHS is facing a workforce crisis where cross-covering of ward-based health professionals is at an all-time high, this includes nurses, doctors, therapists, pharmacists and clerks. Comprehensive post-operative care documentation is essential to maintain patient safety, reduce information clarification requests, delays in rehabilitation, treatment, and investigations. The value of complete surgical registry data is emerging, and in the UK this has recently become mandated, but the completeness of post-operative care documentation is not held to the same importance, and at present there is no published standard. This project summarises a 4-stage approach, including 6 audit cycles, >400 reviewed operation notes, over a 5 year period. OBJECTIVE. To deliver a sustainable change in post operative care documentation practices through quality improvement frameworks. METHODS. Stage 1: Characterise the problem and increase engagement through: SMART aims, process mapping, hybrid action-effect and driver diagram and stakeholder analysis. Multi disciplinary stakeholders were involved in achieving a consensus of evidence-based auditable criteria. Stage 2: Baseline audit to assess current practice. Stage 3: Intervention planning by stakeholders. Stage 4: Longitudinal monitoring through run charts and iterative refinement. RESULTS. Stage 1: Process mapping identified numerous downstream effects of the absence of critical information from operation notes, and the action-effect diagram highlighted the multiple unnecessary mitigating actions performed by ward staff. An MDT consensus was achieved on 15 essential criteria for complete documentation, including important negative fields. Interest-influence matrix identified stakeholder groups with high influence but low interest who needed engagement to deliver change. Stage 2: Baseline audit demonstrated unexpectedly poor documentation: >75% compliance in 4 criteria, and <50% compliance in 10 criteria, which elevated the interest of key stakeholders. Stage 3: A post-operative care template based on the 15 criteria was embedded within the existing IT software. It allowed use of existing operative templates, with a non-overwriting suffix requiring only two mouse clicks. Stage 4: Re-audit at 3 and 12 months showed improved and sustained compliance. At 24 months compliance had declined. Questionnaire of template usage identified problems of criteria response options, and lack of awareness of template by newly appointed staff. Template update improved compliance over the next 6 months (>75% compliance in 11 criteria). Finally, a further reaudit conducted 12 months after the template update (5 years post baseline audit) showed a sustained improvement in compliance (>75% compliance in 13 criteria). CONCLUSIONS. Simple innovation through quality improvement frameworks has changed documentation practices by 1) achieving a consensus from stakeholders, 2) a “shock and awe” moment to highlight existing poor documentation and increase engagement 3) implementing change which fit easily into existing systems, 4) respecting autonomy rather than enforcing change and 5) longitudinal monitoring using run charts and an iterative process to ensure the template remains fit for purpose. This model has now successfully been translated to other subspecialities within the orthopaedic department. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 3 - 3
1 Dec 2022
Leardini A Caravaggi P Ortolani M Durante S Belvedere C
Full Access

Among the advanced technology developed and tested for orthopaedic surgery, the Rizzoli (IOR) has a long experience on custom-made design and implant of devices for joint and bone replacements. This follows the recent advancements in additive manufacturing, which now allows to obtain products also in metal alloy by deposition of material layer-by-layer according to a digital model. The process starts from medical image, goes through anatomical modelling, prosthesis design, prototyping, and final production in 3D printers and in case post-production. These devices have demonstrated already to be accurate enough to address properly the specific needs and conditions of the patient and of his/her physician. These guarantee also minimum removal of the tissues, partial replacements, no size related issues, minimal invasiveness, limited instrumentation. The thorough preparation of the treatment results also in a considerable shortening of the surgical and of recovery time. The necessary additional efforts and costs of custom-made implants seem to be well balanced by these advantages and savings, which shall include the lower failures and revision surgery rates. This also allows thoughtful optimization of the component-to-bone interfaces, by advanced lattice structures, with topologies mimicking the trabecular bone, possibly to promote osteointegration and to prevent infection. IOR's experience comprises all sub-disciplines and anatomical areas, here mentioned in historical order. Originally, several systems of Patient-Specific instrumentation have been exploited in total knee and total ankle replacements. A few massive osteoarticular reconstructions in the shank and foot for severe bone fractures were performed, starting from mirroring the contralateral area. Something very similar was performed also for pelvic surgery in the Oncology department, where massive skeletal reconstructions for bone tumours are necessary. To this aim, in addition to the standard anatomical modelling, prosthesis design, technical/technological refinements, and manufacturing, surgical guides for the correct execution of the osteotomies are also designed and 3D printed. Another original experience is about en-block replacement of vertebral bodies for severe bone loss, in particular for tumours. In this project, technological and biological aspects have also been addressed, to enhance osteointegration and to diminish the risk of infection. In our series there is also a case of successful custom reconstruction of the anterior chest wall. Initial experiences are in progress also for shoulder and elbow surgery, in particular for pre-op planning and surgical guide design in complex re-alignment osteotomies for severe bone deformities. Also in complex flat-foot deformities, in preparation of surgical corrections, 3D digital reconstruction and 3D printing in cheap ABS filaments have been valuable, for indication, planning of surgery and patient communication; with special materials mimicking bone strength, these 3D physical models are precious also for training and preparation of the surgery. In Paediatric surgery severe multi planar & multifocal deformities in children are addressed with personalized pre-op planning and custom cutting-guides for the necessary osteotomies, most of which require custom allografts. A number of complex hip revision surgeries have been performed, where 3D reconstruction for possible final solutions with exact implants on the remaining bone were developed. Elective surgery has been addressed as well, in particular the customization of an original total ankle replacement designed at IOR. Also a novel system with a high-tibial-osteotomy, including a custom cutting jig and the fixation plate was tested. An initial experience for the design and test of custom ankle & foot orthotics is also in progress, starting with 3D surface scanning of the shank and foot including the plantar aspect. Clearly, for achieving these results, multi-disciplinary teams have been formed, including physicians, radiologists, bioengineers and technologists, working together for the same goal


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 7 - 7
1 Dec 2021
Jamal S Ibrahim Y Akhtar K
Full Access

Abstract. Objective. Open fracture management in the United Kingdom and several other countries is guided by the British Orthopaedic Association's Standards for Trauma Number 4 (BOAST-4). This is updated periodically and is based on the best available evidence at the time. The aim of this study is to evaluate the evidence base forming this guidance and to highlight new developments since the last version in 2017. Methods. Searches have been performed using the PubMed, Embase and Medline databases for time periods a) before December 31, 2017 and from 01/01/2018–01/02/2021. Results have been summarised and discussed. Results. Several contentious issues remain within the 2017 guideline. Antibiotic guidance, the use of antibiotic impregnated PMMA beads and intramedullary devices, irrigation in the emergency department, time to theatre and the use of negative pressure dressings and guidance regarding the management of paediatric injuries have all demonstrated no clear consensus. Conclusion. The advent of the BOAST-4 guideline has been of huge benefit, however the refinement and improvement of this work remains ongoing. There remains a need for further study into these contentious issues previously listed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 120 - 120
1 Jan 2017
Wylde V Moore A Howells N MacKichan F Bruce J McCabe C Blom A Dieppe P Gooberman-Hill R
Full Access

Around 20% of patients who have total knee replacement find that they experience long-term pain afterwards. There is a pressing need for better treatment and management for patients who have this kind of pain but there is little evidence about how to improve care. To address this gap we are developing a complex intervention comprising a clinic to assess potential causes of a patient's long-term pain after knee replacement and onwards referral to appropriate, existing services. The Medical Research Council recommends that development of complex interventions include several stages of development and refinement and involvement of stakeholders. This study comprises the penultimate stage in the comprehensive development of this intervention. Earlier stages included a survey of current practice, focus groups with healthcare professionals, a systematic review of the literature and expert deliberation. Healthcare professionals from diverse clinical backgrounds with experience of caring for patients with long-term pain after knee replacement were sent a study information pack. Professionals who wished to participate were asked to return their signed consent form and completed study questionnaire to the research team. Participants rated the appropriateness of different aspects of the assessment process and care pathway from 1–9 (not appropriate to very appropriate). Data were collated and a document prepared, consisting of anonymised mean appropriateness ratings and summaries of free-text comments. This document was then discussed in 4 facilitated meetings with healthcare professional held at the future trial centres. A summary report and revised care pathway was then prepared and sent to participants for further comments. 28 professionals completed the questionnaire and/or attended a meeting. Participants included surgeons, physiotherapists, nurses, pain specialists and rheumatologists. Mean appropriateness scores ranged from 6.9 to 8.4. Taking a score of 7–9 as agreement, consensus was achieved that the assessment should be performed at 3 months post-operative by an extended scope practitioner/nurse, treatment be guided by a standardised assessment of pain, and treatment individualised. There was also agreement that referrals in the care pathway to surgical review, GP and pain clinics were appropriate. Nurse-led/self-monitoring was rated lower (6.9) because of considerations about the need to ensure that patients receive appropriate support, follow-up and referral to other services. This work demonstrates the research methods that can be used to refine the design of a complex intervention. The process and findings enable refinement of an intervention for patients with long-term pain after knee replacement. The next stage of intervention development will assess the acceptability and reliability of the assessment process, and the usability of the intervention's standard operating procedures. The intervention will then be evaluated by a larger research team in a multi-centre randomised controlled trial, starting in late 2016


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 17 - 17
1 Nov 2018
Dalgarno K Benning M Partridge S Tulah A Ahmed S Dickinson A Genever P Pearson R Feichtinger G Loughlin J Ferreira-Duarte A
Full Access

This paper reports on a proof of concept project funded by the UK National Council for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs), with the aim of developing an in vitro model to recapitulate the human osteoarthritic joint, based on a multiple human cell type co-culture system, for research and drug development in OA. The targets were: (i) the development of a cell culture platform that could produce a mixed stable cell culture of cell types that represent the key components of the human joint: synoviocytes – type I and type II; osteoblasts; osteoclasts; chondrocytes/cartilage or cartilage-like matrix; adipocytes; and immune cells. (ii) demonstration of cell phenotype stability and viability for at least 72 hours. In order to establish the cell culture platform we have developed an eight-channel cell printer, capable of accurately and reliably printing the required cell types to create osteochondral and synovial cell types within a transwell system. Two different sets of cells have been developed and processed using the cell printer: a set based on using an immortalised hTERT MSC line to create osteoblasts, chondrocytes and adipocytes, with commercial cells lines providing the other cell types, and a set obtained from tissue excised during orthopaedic surgery. This gives both a repeatable set of cells with which to undertake mode of action studies, and a bank of cell sets which will be representative of different stages of osteoarthritis. The co-cultures have been immunohistochemically assessed in order to demonstrate maintenance of phenotype


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 17 - 17
1 Apr 2018
Daumer M Fürmetz J Keppler A Höfling H Müller A Hariry S Schieker M Grassi M Greese B Nuritdinow T Aigner G Lederer C Böcker W
Full Access

Mobility plays an important role, in particular for patients with osteoporosis and after trauma surgery, both as an outcome and as treatment. Mobility is closely linked to the patient”s quality of life and exercise is a powerful additional treatment option. In order to be able to generate an evidence base to evaluate various surgical and non-surgical treatment options, objective measurements of patient mobility and exercise over a certain time period are needed. Wearables are a promising candidate, with obvious advantages compared to questionnaires and/or PROs. However, when extracting parameters with wearables, one often faces the problem of algorithms not performing well enough for special cases like slow gait speeds or impaired gait, as they typically appear in this patient group. We plan to further extend the applicability of the actibelt system (3D accelerometer, 100Hz), in particular to improve the measurement precision of real-world walking speed in slow and impaired walking. We are using a special measurement wheel including a rotating 3D accelerometer that allows to capture high quality real-world walking speed and distance measurements, and a mobile high resolution camera system. In a first block 20 patients with osteoporosis were included in the study at the Ludwigs-Maximilians-University”s Department of General, Trauma and Reconstructive Surgery in Munich, Germany and equipped with an actibelt. Patients were asked to walk as “normal” as possible, while wearing their usual apparel, in the building and outside the building. They climbed stairs and had to deal with all unexpected “stop and go” events that appear in real-world walking. Various gait parameters will be extracted from the recorded data and compared to the gold standard. We will then tune the existing algorithms as well as new algorithms (e.g. step detection based on continuous wavelet transformation) to explore potential improvements of both step detection and speed estimation algorithms. Further refinement and validation using real world data is warranted


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_11 | Pages 16 - 16
1 Oct 2015
Mueller A Clegg P
Full Access

Introduction. The rabbit common calcanean (Achilles) tendon is a compound apparatus frequently used in studies considering novel interventions to facilitate tendon regeneration. These studies often employ complete surgical transection of the apparatus. Due consideration of the translational relevance to human tendinopathy is often lacking and refinement of this injury model, consistent with the principles of the 3Rs, has not been forthcoming. Materials and Methods. Wild rabbit cadavers (n=10) were obtained from a licensed game dealer. For gross anatomy studies the caudal crus was dissected and transverse sections obtained every 5 mm. Ultrasongraphic examination of the entire apparatus was peformed with a 15 Hz transducer in transverse sections. Results. This study reannotates the apparatus and demonstrates that the principal structures, the superficial digital flexor tendon and medial and lateral gastrocnemius tendons, may be clearly identified by ultrasonographic examination. Discussion. Historical descriptions of the rabbit Achilles apparatus are shown to be inaccurate and follow human gross anatomical descriptions. Ultrasonographic identification of the constituent structures in the rabbit are poorly represented in the literature. Reference measurements and qualitative descriptions are provided that may facilitate the development of refined surgical techniques for in vivo studies of tendon regeneration in the rabbit beyond crude transection studies


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 18 - 18
1 Oct 2016
Smith NL Stankovic V Riches PE
Full Access

A number of advantages of unicondylar arthroplasty (UKA) over total knee arthroplasty in patients presenting osteoarthritis in only a single compartment have been identified in the literature. However, accurate implant positioning and alignment targets, which have been shown to significantly affect outcomes, are routinely missed by conventional techniques. Computer Assisted Orthopaedic Surgery (CAOS) has demonstrated its ability to improve implant accuracy, reducing outliers. Despite this, existing commercial systems have seen extremely limited adoption. Survey indicates the bulk, cost, and complexity of existing systems as inhibitive characteristics. We present a concept system based upon small scale head mounted tracking and augmented reality guidance intended to mitigate these factors. A visible-spectrum stereoscopic system, able to track multiple fiducial markers to 6DoF via photogrammetry and perform semi-active speed constrained resection, was combined with a head mounted display, to provide a video-see-through augmented reality system. The accuracy of this system was investigated by probing 180 points upon a 110×110×50 mm known geometry and performing controlled resection upon a 60×60×15 mm bone phantom guided by an overlaid augmented resection guide that updated in real-time. The system produced an RMS probing accuracy and precision of 0.55±0.04 and 0.10±0.01 mm, respectively. Controlled resection resulted in an absolute resection error of 0.34±0.04 mm with a general trend of over-resection of 0.10±0.07 mm. The system was able to achieve the sub-millimetre accuracy considered necessary to successfully position unicondylar knee implants. Several refinements of the system, such as pose filtering, are expected to increase the functional volume over which this accuracy is obtained. The presented system improves upon several objections to existing commercial CAOS UKA systems, and shows great potential both within surgery itself and its training. Furthermore, it is suggested the system could be readily extended to additional orthopaedic procedures requiring accurate and intuitive guidance


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 1 - 1
1 Apr 2012
Augustine A Horey L Murray H Craig D Meek R Patil S
Full Access

The diagnosis and treatment of hip disease in young adults has rapidly evolved over the past ten years. Despite the advancements of improved diagnostic skills and refinement of surgical techniques, the psychosocial impact hip disease has on the young adult has not yet been elucidated. This observational study aimed to characterise the functional and psychosocial characteristics of a group of patients from our young hip clinic. 49 patients responded to a postal questionnaire which included the Oswestry Disability Index (ODI) and Hospital Anxiety and Depression Scale (HADS). Median age was 20 years (range 16-38) with a gender ratio of 2:1 (female: male). The most common diagnoses were Perthes' disease and developmental hip dysplasia. More than half of our patients had moderate to severe pain based on the Visual Analogue Scale (VAS) and at least a moderate disability based on the ODI. Thirty-two percent of patients were classified as having borderline to abnormal levels of depression and 49% of patients were classified as having borderline to abnormal levels of anxiety based on the HADS. Comparison of the ODI with the VAS and HADS anxiety and depression subscales showed a significant positive correlation (p<0.05). Multiple regression showed the ODI to be a significant predictor of the HADS anxiety and depression scores (regression coefficient 0.13, 95% confidence interval 0.06 to 0.21, p<0.05). This study highlights the previously unrecognised psychosocial effects of hip disease in the young adult. A questionnaire which includes HADS may be of particular value in screening for depression and anxiety in young people with physical illness. This study also highlights that collaboration with psychologists and other health care providers may be required to achieve a multidisciplinary approach in managing these patients


Bone & Joint Research
Vol. 5, Issue 12 | Pages 610 - 618
1 Dec 2016
Abubakar AA Noordin MM Azmi TI Kaka U Loqman MY

In vivo animal experimentation has been one of the cornerstones of biological and biomedical research, particularly in the field of clinical medicine and pharmaceuticals. The conventional in vivo model system is invariably associated with high production costs and strict ethical considerations. These limitations led to the evolution of an ex vivo model system which partially or completely surmounted some of the constraints faced in an in vivo model system. The ex vivo rodent bone culture system has been used to elucidate the understanding of skeletal physiology and pathophysiology for more than 90 years. This review attempts to provide a brief summary of the historical evolution of the rodent bone culture system with emphasis on the strengths and limitations of the model. It encompasses the frequency of use of rats and mice for ex vivo bone studies, nutritional requirements in ex vivo bone growth and emerging developments and technologies. This compilation of information could assist researchers in the field of regenerative medicine and bone tissue engineering towards a better understanding of skeletal growth and development for application in general clinical medicine.

Cite this article: A. A. Abubakar, M. M. Noordin, T. I. Azmi, U. Kaka, M. Y. Loqman. The use of rats and mice as animal models in ex vivo bone growth and development studies. Bone Joint Res 2016;5:610–618. DOI: 10.1302/2046-3758.512.BJR-2016-0102.R2.


Bone & Joint Research
Vol. 2, Issue 11 | Pages 245 - 247
1 Nov 2013
Sprowson AP Rankin KS McNamara I Costa ML Rangan A

The peer review process for the evaluation of manuscripts for publication needs to be better understood by the orthopaedic community. Improving the degree of transparency surrounding the review process and educating orthopaedic surgeons on how to improve their manuscripts for submission will help improve both the review procedure and resultant feedback, with an increase in the quality of the subsequent publications. This article seeks to clarify the peer review process and suggest simple ways in which the quality of submissions can be improved to maximise publication success.

Cite this article: Bone Joint Res 2013;2:245–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 865 - 874
1 Jul 2012
Mills LA Simpson AHRW

This review is aimed at clinicians appraising preclinical trauma studies and researchers investigating compromised bone healing or novel treatments for fractures. It categorises the clinical scenarios of poor healing of fractures and attempts to match them with the appropriate animal models in the literature.

We performed an extensive literature search of animal models of long bone fracture repair/nonunion and grouped the resulting studies according to the clinical scenario they were attempting to reflect; we then scrutinised them for their reliability and accuracy in reproducing that clinical scenario.

Models for normal fracture repair (primary and secondary), delayed union, nonunion (atrophic and hypertrophic), segmental defects and fractures at risk of impaired healing were identified. Their accuracy in reflecting the clinical scenario ranged greatly and the reliability of reproducing the scenario ranged from 100% to 40%.

It is vital to know the limitations and success of each model when considering its application.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 586 - 594
1 Apr 2010
Sonnabend DH Howlett CR Young AA

The establishment of a suitable animal model of repair of the rotator cuff is difficult since the presence of a true rotator cuff anatomically appears to be restricted almost exclusively to advanced primates. Our observational study describes the healing process after repair of the cuff in a primate model. Lesions were prepared and repaired in eight ‘middle-aged’ baboons. Two each were killed at four, eight, 12 and 15 weeks post-operatively. The bone-tendon repair zones were assessed macroscopically and histologically.

Healing of the baboon supraspinatus involved a sequence of stages resulting in the reestablishment of the bone-tendon junction. It was not uniform and occurred more rapidly at the sites of suture fixation than between them. Four weeks after repair the bone-tendon healing was immature. Whereas macroscopically the repair appeared to be healed at eight weeks, the Sharpey fibres holding the repair together did not appear in any considerable number before 12 weeks. By 15 weeks, the bone-tendon junction was almost, but not quite mature.

Our results support the use of a post-operative rehabilitation programme in man which protects the surgical repair for at least 12 to 15 weeks in order to allow maturation of tendon-to-bone healing.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis.