Bhatia M Singh S Housden P
Full Access

We present an objective method for predicting the redisplacement of paediatric forearm and wrist fractures. Novel radiographic measurements were defined and their value assessed for clinical decision making. In Phase I of the study we defined the cast index and padding index and correlated these measurements with the incidence of fracture redisplacement. Phase II assessed these indices for their value in clinical decision making. Cast Index (a/b) is the ratio of cast width in lateral view (a) and the width of the cast in AP view (b). Padding Index (x/y) isthe ratio of padding thickness in the plane of maximum deformity correction (x) and the greatest interosseous distance (y) in AP view. The sum of cast index and padding index was defined as the Canterbury Index. In Phase I, 142 children's radiographs were analysed and a statistically significant difference was identified between redisplacement and initial complete off-ending of the bones, cast index > 0.8 and padding index of > 0.3. There was no significant association with age, fracture location, seniority of surgeon or angulation. In Phase II, radiographs of 5 randomly selected cases were presented to 40 surgeons (20 consultants & 20 registrars). Following an eyeball assessment they were asked to measure the cast index and padding index (after instruction). With eyeballing the consultants predicted 33% and registrars 25% of the cases that redisplaced. After learning to measure the indices the accuracy increased to 72% for consultants and 81% for registrars (p<0.001). We conclude that the cast index, padding index and Canterbury Index are validated tools to assess plaster cast quality and can be used to predict redisplacement of paediatric forearm fractures after manipulation. They can easily be taught to orthopaedic surgeons and are more accurate than eyeballing radiographs in the clinical setting. Redisplacement can be predicted if cast index > 0.8, padding index > 0.3 and Canterbury Index > 1.1


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 22 - 22
1 Mar 2013
Chivers D Hilton T Dix-Peek S
Full Access

Purpose

Distal metaphyseal radial fractures are common in the paediatric population and the management of these fractures is controversial. The incidence of re-displacement in the closed management of these fractures is as much as 30% in some studies. Various methods have been described with the view to predict fracture displacement of distal radial fractures in children. One of these indices is the three point index (TPI). This index seeks to assess the adequacy of 3 point moulding and thus predict fracture displacement. It is a calculated ratio that if above 0.8 states that there is an increased risk of fracture re-displacement. The purpose of this study is to assess the accuracy of this index in predicting displacement of distal radial fractures in children.

Methods

This retrospective study included 65 patients of both sexes under the age of 13 for a period of one year from January 2011 to January 2012. All patients with a dorsally displaced fracture of the distal radius were included. 22 patients were excluded because of loss to follow-up or absence of a complete series of x-rays. All patients were taken to theatre for a general anaesthetic and manipulation of their fractures using an image intensifier to confirm reduction. X-rays of initial fracture displacement, post manipulation position and follow-up fracture position at 2 and 6 weeks were assessed. The sensitivity, specificity, negative and positive predictive values of the TPI in screening for fracture re-displacement were calculated.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 24 - 24
1 May 2015
Chaudhury S Hurley J White HB Agyryopolous M Woods D
Full Access

Distal radius and ulna fractures are a common paediatric injury. Displaced or angulated fractures require manipulation under anaesthetic (MUA) with or without Kirchner (K) wire fixation to improve alignment and avoid malunion. After treatment a proportion redisplace requiring further surgical management. This study aimed to investigate whether the risk of redisplacement could be reduced by introducing surgical treatment guidelines to ascertain whether MUA alone or the addition of K wire fixation was required. A cohort of 51 paediatric forearm fractures managed either with an MUA alone or MUA and K wire fixation was analysed to determine fracture redisplacement rates and factors which predisposed to displacement. Guidelines for optimal management were developed based on these findings and published literature and implemented for the management of 36 further children. A 16% post-operative redisplacement rate was observed within the first cohort. Redisplacement was predicted if an ‘optimal reduction’ of less than 5° of angulation and/or 10% of translation was not achieved and no K wire fixation utilised. Adoption of the new guidelines resulted in a significantly reduced redisplacement rate of 6%. Implementation of departmental guidelines have reduced redisplacement rates of children's forearm fractures at Great Western Hospital


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 15 - 15
1 Jul 2016
Kiran M Chakkalakumbil S George H Walton R Garg N Bruce C
Full Access

The aim of this study is to discuss the results of intramedullary devices in the management of paediatric radial neck fractures and to suggest methods to avoid the pitfalls of the technique. 30 patients with isolated Judet III and IV fractures were included in this retrospective study. The method of reduction was reviewed. The final results were graded using the Metaizeau functional scoring system and Oxford Elbow score. Intramedullary K wires were used in 10 patients and blunt tipped TENS nails in 20 patients. The complications seen were radiocapitellar joint penetration-6 cases at mean 4.87 weeks, redisplacement − 6, radial epiphyseal sclerosis − 5 and heterotopic ossification − 1 case. The functional result was good to excellent in 24 of 30 cases(80%). The mean Oxford Elbow score was 44.32. The mean follow-up was 40.11 months. Intramedullary K wires may result in radiocapitellar joint penetration. Blunt tipped devices should not be used as purely fixation devices as they may not prevent redisplacement. Minimal redisplacement does not affect the functional outcome. Regular follow-up until atleast 6 weeks is essential. Patients who have a Judet IV fracture and need open reduction should be closely followed up and given a guarded prognosis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 105 - 105
1 Mar 2012
Guha A Das S Debnath U Shah R Lewis K
Full Access

Introduction. Displaced distal radius fractures in children have been treated in above elbow plaster casts since the last century. Cast index has been calculated previously, which is a measure of the sagittal cast width divided by the coronal cast width measurement at the fracture site. This indicates how well the cast was moulded to the contours of the forearm. We retrospectively analysed the cast index in post manipulation radiographs to evaluate its relevance in redisplacement or reangulation of distal forearm fractures. Study Design. Consecutive radiographic analysis. Materials and methods. 156 consecutive paediatric patients (114M : 42F), with a mean age of 9.8 years (range 2-15 years), presenting with forearm fractures were studied. All patients were manipulated in OR and a moulded above elbow cast was applied. The cast index was measured on immediate post manipulation radiographs. Results. Displacement of the fracture within the original plaster cast occurred in 30 patients (19%), 22/114 males; 8/42 females. The cast index in the 30 patients requiring a second procedure (mean 0.92, SD=0.08) was significantly more than the cast index (mean 0.77, SD=0.07) in the others (p< .001). Discussion. A high cast index in post manipulation radiographs indicates increased risk of re-displacement of the fracture and these patients should be kept under close review. Conclusion. Cast index is a valuable tool to assess the quality of moulding of the cast following closed manipulation of distal radius fractures in children. The maximum acceptable cast index should be 0.82