Aim: This study was performed to review the early results of the use of a semi-constrained acetabular component in the treatment of
We investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores. We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications.Aims
Patients and Methods
Although the incidence of total hip dislocation has decreased, it still remains a major problem particularly if recurrent. The actual incidence is around 1–2% but it has been documented as the leading cause for hip revision in the United States. In patients with
Although the incidence of total hip dislocation has decreased, it still remains a major problem particularly if recurrent. The actual incidence is around 1–2% but it has been documented as the leading cause for hip revision in the United States. In patients with
Early reports on revision total hip arthroplasty (RTHA) suggested that outcomes of this procedure are as good as those of primary total hip arthroplasty (THA). However, RTHA is associated with longer surgery time, greater blood loss and increased risk of complications (thromboembolism, nerve injury, periprosthetic fractures,
Introduction. Revision surgery is generally recommended for recurrent dislocation following Total hip arthroplasty (THA). However, dislocation following revision THA continues to remain a problem with further dislocation rates upto 28% quoted in literature. We present early results of one of the largest series in U.K. using dual mobility cemented acetabular cup for
Dual mobility components for total hip arthroplasty provide for an additional articular surface, with the goals of improving range of motion, jump distance, and overall stability of the prosthetic hip joint. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit into the large polyethylene. The first such device was introduced for primary total hip arthroplasty by Bousquet in the 1970s, thus, the “French connection”. Dual mobility components have been released for use in North America over the past five years. In some European centers, these components are routinely used for primary total hip arthroplasty. However, their greatest utility may be to manage recurrent dislocation in the setting of revision total hip arthroplasty. Several retrospective series and the Swedish hip registry have shown satisfactory results for this indication at short- to medium-term follow-up times. However, there are important concerns with polyethylene wear, late intraprosthetic dislocation, and the lack of long-term follow-up data. These components are an important option in the treatment of recurrent dislocation in younger patients, revision of failed metal-metal resurfacing, and salvage of failed constrained liners. There are more recent concerns of possible iliopsoas tendinitis, elevated metal levels with one design, and acute early intraprosthetic dislocation following attempted closed reduction. However, a dual mobility component may now be the preferred solution in revision surgery for
Uncemented double-mobility acetabular cups, first used in the late 1970s as a solution to
Purpose. Overall outcome of bilateral hip and knee arthroplasty in the same patient with special regard to scheduling, postoperative complications and follow-up under consideration of the underlying disease. Method. More than 6000 primary THA and 5500 primary TKA were implanted at Schulthess Clinic since 1985, 8% of which in rheumatoid patients. Quadruple THA and TKA was performed in a total of 51 rheumatoid patients. Mean follow-up for knees was 8. 5 years (1–17), and 9. 5 years (1–18) for hips. 67% of implants were uncemented. In 21% of patients, all four prostheses were implanted within one year and in over 50% within a five year period. Results. Taking revision of components as failure there were three infections (CLS hip, GSB and LCS knee), two aseptic loosenings (Endler cup, GSB knee), two
Controversy has existed for decades over the role of fretting-corrosion in modular CoCr heads used with stems of CoCr vs Ti6Al4V. Since retrieval data on taper performance remains scant, we report here an18-year survivorship of a Ti6Al4V: CoCr combination (APR design; Intermedics Inc). Unique to this study were the threaded profiles present on both stem and head tapers (Fig. 1). This female patient was revised for pain, osteolysis and
Aims: This study evaluated the outcome of bilateral hip and knee arthroplasty in the same patient with special regards to schedule planning, postoperative complications and follow-up. Methods: Since 1985 more than 6000 THA and 5500 TKA were implanted in one large center, of which 8% were rheumatoid patients. Quadruple THA and TKA were performed in a total of 58 (0.1%) of which 88% were RA. Mean follow-up of knees was 8.5 years (1–17), of hips 9.5 years (1–18). On average 67% of implants were uncemented. In 21% of the cases all four prostheses were implanted within one year and over 50% within five years. Results: Taking revision of components as failure there were three infections (CLS hip, GSB and LCS knee), two aseptic loosenings (Endler cup, GSB knee), two
Juvenile hip instability is associated with many conditions. Most of them belong to the group of neuromuscular diseases. Generally following categories can be enumerated: 1. Cerebral palsy, 2. Myelomeningocele, 3. Spinal cord injury, 4. Paraplegia following spine surgery, 5. Poliomyelitis, 6. Inflammatory hip disease, 7. Idiopathic instability, 8. Recurrent post-traumatic hip instability. In the groups 1–5 a chronic muscle imbalance is the reason of the displacement of the femoral head. Inflammatory joint disease produces displacement through cartilage and bone destruction and increased intra-articular pressure. Very rare idiopathic instability is usually associated with generalised hypermobility. For the early diagnosis a careful clinical examination is necessary involving range of motion, testing of the hip stability by the Palmén’s test in the same way like in new-borns. Routine x-ray screening at least once per year is mandatory. For the groups 1–5 a muscle imbalance has to be corrected first. Elimination of muscles contractures or muscles transfers respectively, showed a high efficiency if these surgical corrections were performed early. Femoral osteotomy alone does not provide reliable results. Any form of pelvic osteotomy is necessary to correct acetabular insufficiency. For the inflammatory hip disease early active surgical treatment is best prevention of displacement. Idiopathic hip instability has to be differentiated from common snapping hip. No treatment is necesary.
Introduction: Revision Hip Surgery presents an increasing Orthopaedic Burden. Indications for revision include
Nonagenarians (aged 90 to 99 years) have experienced the fastest percent decile population growth in the USA recently, with a consequent increase in the prevalence of nonagenarians living with joint arthroplasties. As such, the number of revision total hip arthroplasties (THAs) and total knee arthroplasties (TKAs) in nonagenarians is expected to increase. We aimed to determine the mortality rate, implant survivorship, and complications of nonagenarians undergoing aseptic revision THAs and revision TKAs. Our institutional total joint registry was used to identify 96 nonagenarians who underwent 97 aseptic revisions (78 hips and 19 knees) between 1997 and 2018. The most common indications were aseptic loosening and periprosthetic fracture for both revision THAs and revision TKAs. Mean age at revision was 92 years (90 to 98), mean BMI was 27 kg/m2 (16 to 47), and 67% (n = 65) were female. Mean time between primary and revision was 18 years (SD 9). Kaplan-Meier survival was used for patient mortality, and compared to age- and sex-matched control populations. Reoperation risk was assessed using cumulative incidence with death as a competing risk. Mean follow-up was five years.Aims
Methods
Acetabular component malposition is the cause of half of all cases of
Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear. Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.Aims
Methods
Recurrent posterior dislocation is a recognised complication following primary total hip arthroplasty. Incidences of between 0.11% and 4.5% have been reported in the literature. Component revision is regarded as standard management of recurrent posterior dislocation. However, revision surgery is a major surgical procedure and is often unsuitable for elderly, frail patients. A congruent, ultra-high molecular weight polyethylene acetabular augment with a stainless steel backing plate has been developed. This can be inserted providing there is no malalignment, wear or loosening of the primary components. In this study we compared twenty patients who underwent conventional revision surgery to twenty patients who had a PLAD inserted for recurrent posterior dislocation following primary Charnley total hip arthroplasty. Both groups were age and sex-matched and the average number of dislocations prior to surgery was three for each group. For the PLAD group, the mean operative time, the mean intraoperative blood loss, the time spent in HDU, the transfusion requirements and the duration of hospital stay was significantly less than that for the revision group. Furthermore, there was no significant difference in the Oxford Hip Score recorded preoperatively and at 6 weeks, 6 months, one year and two years following surgery. None of the patients had sustained a further dislocation at latest review. We conclude that the Posterior Lip Augmentation Device is a safe and effective option in the management of patients with
Femoral revision component subsidence has been identified as predicting early failure in revision hip surgery. This comparative cohort study assessed the potential risk factors of subsidence in two commonly used femoral implant designs. A comparative cohort study was undertaken, analyzing a consecutive series of patients following revision total hip arthroplasties using either a tapered-modular (TM) fluted titanium or a porous-coated cylindrical modular (PCM) titanium femoral component, between April 2006 and May 2018. Clinical and radiological assessment was compared for both treatment cohorts. Risk factors for subsidence were assessed and compared.Aims
Methods
The aim of this study was to evaluate the prosthesis characteristics and associated conditions that may modify the survival of total femoral endoprosthetic replacements (TFEPR). In all, 81 patients treated with TFEPR from 1976 to 2017 were retrospectively evaluated and failures were categorized according to the Henderson classification. There were 38 female patients (47%) and 43 male patients (53%) with a mean age at diagnosis of 43 years (12 to 86). The mean follow-up time was 10.3 years (0 to 31.7). A survival analysis was performed followed by univariate and multivariate Cox regression to identify independent implant survival factors.Aims
Patients and Methods