The most frequent mode of aseptic failure of primary total knee replacements is tibial baseplate loosening. This is influenced by stresses across the implant-bone interface which can be increased in obese patients leading to potentially higher rates of early failure. The evidence is mixed as to the true effect of elevated BMI (body mass index) on revision rates. We present the experience of early tibial failures in our department and how our implant choices have evolved. We retrospectively reviewed our unit's arthroplasty database and identified all patients who had sustained mechanical tibial failure. Data were collected on patient demographics, operative details of primary and revision operations, components used, alignment pre and post operatively and indication. Complications and further surgery performed were recorded.Abstract
INTRODUCTION
METHODOLOGY
Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken.Aims
Methods
Many surgeons choose to perform total knee arthroplasty (TKA) surgery with the aid of a tourniquet. A tourniquet is a device that fits around the leg and restricts blood flow to the limb. There is a need to understand whether tourniquets are safe, and if they benefit, or harm, patients. The aim of this study was to determine the benefits and harms of tourniquet use in TKA surgery. We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled trials, and trial registries up to 26 March 2020. We included randomized controlled trials (RCTs), comparing TKA with a tourniquet versus without a tourniquet. Outcomes included: pain, function, serious adverse events (SAEs), blood loss, implant stability, duration of surgery, and length of hospital stay.Aims
Methods
The aim of this study was to compare the effectiveness of a femoral
nerve block and a periarticular infiltration in the management of
early post-operative pain after total knee arthroplasty (TKA). A pragmatic, single centre, two arm parallel group, patient blinded,
randomised controlled trial was undertaken. All patients due for
TKA were eligible. Exclusion criteria included contraindications
to the medications involved in the study and patients with a neurological
abnormality of the lower limb. Patients received either a femoral
nerve block with 75 mg of 0.25% levobupivacaine hydrochloride around
the nerve, or periarticular infiltration with 150 mg of 0.25% levobupivacaine
hydrochloride, 10 mg morphine sulphate, 30 mg ketorolac trometamol
and 0.25 mg of adrenaline all diluted with 0.9% saline to make a
volume of 150 ml.Aims
Patients and Methods
Cartilage repair in terms of replacement, or
regeneration of damaged or diseased articular cartilage with functional tissue,
is the ‘holy grail’ of joint surgery. A wide spectrum of strategies
for cartilage repair currently exists and several of these techniques
have been reported to be associated with successful clinical outcomes
for appropriately selected indications. However, based on respective
advantages, disadvantages, and limitations, no single strategy, or
even combination of strategies, provides surgeons with viable options
for attaining successful long-term outcomes in the majority of patients.
As such, development of novel techniques and optimisation of current techniques
need to be, and are, the focus of a great deal of research from
the basic science level to clinical trials. Translational research
that bridges scientific discoveries to clinical application involves
the use of animal models in order to assess safety and efficacy
for regulatory approval for human use. This review article provides
an overview of animal models for cartilage repair. Cite this article:
We compared thromboembolic events, major haemorrhage
and death after knee replacement in patients receiving either aspirin
or low-molecular-weight heparin (LMWH). Data from the National Joint
Registry for England and Wales were linked to an administrative
database of hospital admissions in the English National Health Service.
A total of 156 798 patients between April 2003 and September 2008
were included and followed for 90 days. Multivariable risk modelling
was used to estimate odds ratios adjusted for baseline risk factors
(AOR). An AOR <
1 indicates that risk rates are lower with LMWH
than with aspirin. In all, 36 159 patients (23.1%) were prescribed aspirin
and 120 639 patients (76.9%) were prescribed LMWH. We found no statistically
significant differences between the aspirin and LMWH groups in the
rate of pulmonary embolism (0.49% These results should be considered when the existing guidelines
for thromboprophylaxis after knee replacement are reviewed.