Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 169 - 169
1 Jun 2012
Nasser E
Full Access

60 patient where included in this comparative study. Patients where divided into 3 groups. Group A including TKR done navigation guided in a navigation techniques experienced center. Group B including patient done navigation guided in less experienced center. Group c including patients done conventionally by an experienced surgeon. Accuracy was the primary end point. Where an independent observer was requested to comment on the post operative x-ray blindly and to measure accuracy using software. Result showed no significant difference in post operative radiological accuracy in the 3 groups.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 114 - 114
1 May 2016
Laky B Koelblinger R Brandl G Anderl W Schwameis E
Full Access

Arthrodesis of the first metatarsophalangeal joint (MTPJ) has been reported as gold standard for the treatment of advanced hallux rigidus and is a well-documented procedure. However, many patients demand a mobile MTPJ and therefore joint sparing procedures like MTPJ-arthroplasty have gained popularity. The aim of the present study was to present first mid-term results after hemiarthroplasty to treat advanced osteoarthritis of the first MTPJ. Between April 2006 and October 2013, a total of 81 hemiprostheses (AnaToemic®, Arthrex) in 71 consecutive patients (44 females, 27 male, 10 bilateral; mean age, 58 [range, 45–82]) were implanted at the St. Vincent Hospital Vienna (Austria). The indication for surgery was persistent MTPJ pain after failed conservative treatment combined with radiologic evidence of osteoarthritis (advanced hallux rigidus grade II-IV). Patients were clinically examined using the American Orthopaedic Foot and Ankle Society (AOFAS) score before surgery and at the final follow-up visit. Patient's satisfaction with the treatment was recorded. Radiological results were evaluated using standard x-rays and revision surgeries were documented. The mean preoperative AOFAS Scores significantly increased from 51 to 88 points after an average follow-up duration of 5 years (p<0.001). Most patients (76%) were either very satisfied or satisfied with the procedure. Radiological assessment showed some kind of radiolucencies on the base plate, whereas the stem of the prosthesis was well integrated in most of the cases; however clinical outcome was not affected by minor radiolucent lines on the base plate. In the majority of patients the implant was in situ at last follow-up. If revision surgery, due postoperative pain or implant loosening, was required; it occurred within 12 to 36 months. According to our promising mid-term results with a MTPJ-hemiprostheses, we conclude that MTPJ-arthroplasty is an effective alternative treatment modality for anatomical reconstruction of the first MTPJ with the benefit to reduce pain and maintain mobility


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2016
Choi CH Chung KS Lee JK Lee HJ
Full Access

Introduction. The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained bony defects undergoing primary or revision total knee arthroplasty. Materials and Methods. We performed double metal augmentations in proximal tibial uncontained bony defects undergoing total knee arthroplasty. Out of total 14 patients, 8 patients (4 priamry arthroplasty, 4 revision arthroplasty), mean 61.3 (50–80) years, were available for review at least 5 years follow up. The average follow up period was 86.3(60–99) months. Range of motion, American Knee Society Score were evaluated pre- and postoperatively as a clinical values. Another clinical assessments undertaken at the final reviews, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford knee score (OKS), Short Form-36 (SF-36), Lower extremity functional scale (LEFS), and Lower extremity activity scale (LEAS) were checked. Radiological results, involving presence of radiolucent lines (RLLs) > 1mm in width, and osteolysis at the block-cement-bone interface were taken under fluoroscopic images at postoperatively and annually thereafter. Results. At the final follow-up, range of motion was increased from 97.5° to 121.3° and American Knee society score was significantly improved from 30.4 to 92.6 (p=0.03) and functional score from 43.1 to 86.9 (p=0.03). At the final follow-up, average WOMAC score was 10(2–20), OKS was 40.5(33–47), LEFS was 55.8(34–75), and LEAS was 10.9(7–15). There was no broken or deterioration sign at between first and second metal block at radiographically. RLLs at the block-cement-bone interfaces under fluoroscopic images were examined in 3 knees, but didn't cause any failure sign such as osteolysis, or collapse, or instability at final reviews. Conclusions. The clinical and radiological evaluations showed that the double metal augmentations is a favorable and useful way to manage severe uncontained proximal tibial bony defects at least 5 years mid-term follow up period. Preoperative standing anteroposterior (AP) radiograph (Fig 1) shows severe uncontained proximal tibial bone defects, approximately 23 mm compared with unaffected lateral tibial condyle. AP view of fluoroscopy with medial double metal blocks (10 mm block + down sized 10 mm block) combined intramedullary stem at 60-month follow-up after primary total knee arthroplasty, demonstrating radiolucent line (white arrow) of 2.5 mm width bottom the block (Fig 2). AP view at 92-month follow-up indicating non-progressive stable radiolucent lines (white arrow) at same area without any radiographic failure signs and broken sign between first and second metal block (Fig 3)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 322 - 322
1 Mar 2013
Sedel L
Full Access

Starting in 1977 a new cemented stem made of titanium alloy (with vanadium) was designed regarding some principle: rectangular shape, smooth surface covered with thin layer of titanium oxide, filling the medullar cavity. As a consequence: a thin layer of cement. It was designed with a collar. Initial Cementing technique used dough cement, vent tube and finger packing; then we applied cement retractor low viscosity cement and sometimes Harris Syringe. At the moment we went back to initial technique plus a cement retractor made of polyethylene. Many papers looked at long term follow up results depicting about 98 to 100 percent survivors at 10 years and 95 to 98% at 20 years (Hernigou, Hamadouche, Nizard, El Kaim). Clinical as well as radiological results are available. Radiological results depicted some radiolucent lines that appeared at the very long term. They could be related to friction between the stem and the cement. As advocated by Robin Ling, he called “French paradox” the fact that if a cemented prosthesis is smooth and fills the medullary cavity, long term excellent results could be expected. This was the case with stainless steel Kerboull shape, the Ling design (Exeter)and the Ceraver design. The majority of these stems were implanted with an all alumina bearing system. And in some occasion, when revision had to be performed, the stem was left in place (108 cases over 132 revisions). Our experience over more than 5000 stems implanted is outstanding (see figure 1: aspect after 30 years). Discussion other experience with cemented titanium stem were bad (Sarmiento, Fare). We suspect that this was related either to the small size of this flexible material, or to the roughness of its surface. If one uses titanium cemented stem it must be large enough and extra smooth


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 5 - 5
1 Mar 2013
Atsumi T Tamaoki S Nakanishi R Watanabe M Kajiwara T
Full Access

Treatment of the femoral head necrosis with severe extensive collapse in young adults and adolescents are still challenging. We thought preserve the joint and bone stock were important factor for the treatment of femoral head necrosis in young patients. We reviewed the posterior rotational osteotomy for younger patients with severe osteonecrosis. The advantages of posterior rotational osteotomy are; the necrotic area is moved to non-weight bearing portion. The posterior column artery is shifted medially without vascular damage by rotation. Postoperative uncollapsed anterior viable areas are moved to the loaded portion below the acetabular roof in flexed positions. Eighty five hips of 66 young adults (less than 50 years old, mean age; 31 years) with extensive necrosis treated by posterior rotational osteotomy were reviewed with more than 5 year follow up with a mean of 9 years. Results of 13 hips of 12 adolescents (mean age; 14 years) with extensive collapsed necrosis treated by this procedure were also studied with a mean of 6.5 years. A mean degree of posterior rotation was 121. Recollapse was prevented in 77 hips (91%) of adults, and all 13 hips of adolescents on final AP radiographs. Collapsed lesion was remodeled well and resphericity of the postoperative transferred medial collapsed femoral head on final AP radiographs was observed. However, some of the cases were out of indication of the joint preserving procedure showing extensive lesion. In these cases, we performed the MAYO conservative stem for preserving bone stock. Radiological results of 26 hips with osteonecrosis treated by MAYO stem (mean age 42 years, minimum 5 year follow-up. mean; 6.7 years) showed that 2 mm subsidence in one, osteointegration of zone 2, 6 in 93%, no entire lucent line. No hips were revised for late loosening associated with osteolysis. CT imaging indicated that spot welds of zone 2, 6 were found in 100ï¼ï¿½, stress shielding of zone 1, 5 (23.5ï¼ï¿½). These operations were useful particularly for younger patients