Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 11 - 11
1 Jun 2017
O'Connor J Rutherford M Hill J Beverland D Dunne N Lennon A
Full Access

Unknown femur orientation during X-ray imaging may cause inaccurate radiographic measurements. The aim of this study was to assess the effect of 3D femur orientation during radiographic imaging on the measurement of greater trochanter to femoral head centre (GT-FHC) distance.

Three-dimensional femoral shapes (n=100) of unknown gender were generated using a statistical shape model based on a training data of 47 CT segmented femora. Rotations in the range of 0° internal to 50° external and 50° of flexion to 0° of extension (at 10 degree increments) were applied to each femur. A ray tracing algorithm was then used to create 2D images representing radiographs of the femora in known 3D orientations. The GT-FHC distance was then measured automatically by identifying the femoral head, shaft axis and tip of greater trochanter.

Uniaxial rotations had little impact on the measurement with mean absolute error of 0.6 mm and 3.1 mm for 50° for pure external rotation and 50° pure flexion, respectively. Combined flexion and external rotation yielded more significant errors with 10° around each axis introducing a mean error of 3.6 mm and 20° showing an average error of 8.8 mm (Figure 1.). In the cohort we studied, when the femur was in neutral orientation, the tip of greater trochanter was never below the femoral head centre.

Greater trochanter to femoral head centre measurement was insensitive to rotations around a single axis (i.e. flexion or external rotation). Modest combined rotations caused the tip of greater trochanter to appear more distal in 2D and led to deviation from the true value. This study suggests that a radiograph with the greater trochanter appearing below femoral head centre may have been acquired with 3D rotation of the femur.

For any figures or tables, please contact the authors directly by clicking on ‘Info & Metrics’ above to access author contact details.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 1 | Pages 32 - 36
1 Jan 2012
Nho J Lee Y Kim HJ Ha Y Suh Y Koo K

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 17 - 17
1 Jul 2020
Innmann M Merle C Phan P Beaulé P Grammatopoulos G
Full Access

Introduction. Patients with reduced lumbar spine mobility are at higher risk of dislocation after THA as their hips have to compensate for spinal stiffness. Therefore our study aimed to 1) Define the optimal protocol for identifying patients with mobile hips and stiff lumbar spines and 2) Determine clinical and standing radiographic parameters predicting high hip and reduced lumbar spine mobility. Methods. This prospective diagnostic cohort study followed 113 consecutive patients with end-stage hip osteoarthritis (OA) awaiting THA. Radiographic measurements were performed for the lumbar lordosis angle, pelvic tilt and pelvic-femoral angle on lateral radiographs in the standing, ‘relaxed-seated’ and ‘deep-seated’ (i.e. torso maximally leaning forward) position. A “hip user index” was calculated in order to quantify the contribution of the hip joint to the overall sagittal movement performed by the femur, pelvis and lumbar spine. Results. Radiographs in the relaxed-seated position had an accuracy of 56% (95%CI:46–65%) to detect patients with stiff lumbar spines, compared to a detected rate of 100% in the deep-seated position. The mean ‘hip user index’ was 63±12% and ten patients (9%) were hip users, having an index of 80% or more. A standing pelvic tilt of ≥18.5° was the only predictor for being a hip user with a sensitivity of 90% and specificity of 71% (AUC 0.83). Patients with a standing pelvic tilt ≥18.5° and an unbalanced spine with a flatback deformity had a 30xfold relative risk (95%-CI:4–226; p<0.001) of being a hip user. Conclusion. Patients awaiting THA and having high hip and reduced lumbar spine mobility can be screened for with lateral standing radiographs of the spinopelvic complex and a thorough clinical examination. If the initial screening is positive, radiographs in the deep-seated position allow for better identification of patients being ‘hip users’ compared to radiographs in the relaxed-seated position


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 29 - 29
1 Jul 2020
Innmann M Reichel F Schaper B Merle C Beaulé P Grammatopoulos G
Full Access

Aims. Our study aimed to 1) determine if there was a difference for the HOOS-PS score between patients with stiff/normal/hypermobile spinopelvic mobility and 2) to investigate if functional sagittal cup orientation affected patient reported outcome 1 year post-THA. Methods. This prospective diagnostic cohort study followed 100 consecutive patients having received unilateral THA for end-stage hip osteoarthritis. Pre- and 1-year postoperatively, patients underwent a standardized clinical examination, completed the HOOS-PS score and sagittal low-dose radiographs were acquired in the standing and relaxed-seated position. Radiographic measurements were performed for the lumbar-lordosis-angle, pelvic tilt (PT), pelvic-femoral-angle and cup ante-inclination. The HOOS-PS was compared between patients with stiff (ΔPT<±10°), normal (10°≤ΔPT≤30°) and hypermobile spinopelvic mobility (ΔPT>±30°). Results. Preoperatively, 16 patients demonstrated stiff, 70 normal and 14 hypermobile spinopelvic mobility without a difference in the HOOS-PS score (66±14/67±17/65±19;p=0.905). One year postoperatively, 43 patients demonstrated stiff, 51 normal and 6 hypermobile spinopelvic mobility. All postoperative hypermobile patients had normal spinopelvic mobility preoperatively and showed significantly worse HOOS-PS scores compared to patients with stiff or normal spinopelvic mobility (21±17/21±22/35±16;p=0.043). Postoperatively, patients with hypermobile spinopelvic mobility demonstrated no significant difference for the pelvic tilt in the standing position compared to the other two groups (19±8°/16±8°/19±4°;p=0.221), but a significantly lower sagittal cup ante-inclination (36±10°/36±9°/29±8°;p=0.046). Conclusion. The present study demonstrated that patients with normal preoperative and postoperative spinopelvic hypermobility show worse HOOS-PS scores than patients with stiff or normal spinopelvic mobility. The lower postoperative cup ante-inclination seems to force the pelvis to tilt more posteriorly when moving from the standing to seated position (spinopelvic hypermobility) in order to avoid anterior impingement. Thus, functional cup orientation in the sagittal plane seems to affect postoperative patient reported outcome


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 27 - 27
1 May 2018
Innmann M Merle C Gotterbarm T Beaulé P Grammatopoulos G
Full Access

Introduction. The changes in sagittal spino-pelvic balance from standing to sitting in patients with end-stage osteoarthritis (OA) of the hip remain poorly characterized. Our aim was to 1) investigate the contribution of sagittal spino-pelvic movement and hip flexion when moving from a standing to sitting posture in patients with hip OA; 2) determine the proportion of OA-patients with stiff, normal or hypermobile spino-pelvic mobility and 3) identify radiographic parameters correlating with spino-pelvic mobility. Methods. This prospective diagnostic cohort study followed 116 consecutive patients with end-stage osteoarthritis awaiting THR. All patients underwent preoperative standardized radiographs (lateral view) of the lumbar spine, pelvis and proximal femur using EOS© in standing position and with femurs parallel to the floor in order to achieve a 90°-seated position. Radiographic measurements performed included lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI) and pelvic-femoral-angle (PFA). The difference in PT between standing and seated allowed for patient classification based on spino-pelvic mobility into stiff (<±10°), normal (±10–30°), or hypermobile (>±30°). Results. From the standing to the sitting position, the pelvis tilted backwards by a mean of 19.1° (SD 12.8) and the hip was flexed by a mean of 56.6° (SD 17.2). Change in pelvic tilt correlated inversely with change in hip flexion (r=−0.68; P<0.01; r. 2. =0.47). Thirty-two patients (28%) had stiff, 68 (58%) normal and 16 (14%) hypermobile spino-pelvic mobility. Multivariate regression analysis adjusted for patient age, BMI, static LL, SS, PI, PT and PFA showed a correlation for static standing SS and the change in PT (p=0.03; β=2.31; r. 2. =0.34). Conclusion. Hip flexion contributes on average 75% (25–100%) of the motion required to sit upright. Pre-operative assessment would identify patients with spino-pelvic hypermobility (associated greater change in cup orientation) or stiffness (associated increased hip range-of-movement), which would be at greater risk of dislocation


The Bone & Joint Journal
Vol. 100-B, Issue 1_Supple_A | Pages 36 - 43
1 Jan 2018
Hambright D Hellman M Barrack R

Aims

The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging.

Patients and Methods

A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 876 - 883
1 Jul 2014
Grammatopoulos G Pandit HG da Assunção R Taylor A McLardy-Smith P De Smet KA Murray DW Gill HS

The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient’s pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ±32), obliquity –4° (2sd ±12), rotation –8° (2sd ±14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior >  lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ±16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required.

Cite this article: Bone Joint J 2014; 96-B:876–83.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 32 - 35
1 Nov 2012
Brooks P Bershadsky B

Femoroacetabular impingement (FAI) is commonly associated with early hip arthritis. We reviewed our series of 1300 hip resurfacing procedures. More than 90% of our male patients, with an average age of 53 years, had cam impingement lesions. In this condition, there are anterior femoral neck osteophytes, and a retroverted femoral head on a normally anteverted neck. It is postulated that FAI results in collision of the anterior neck of the femur against the rim of the acetabulum, causing damage to the acetabular labrum and articular cartilage, resulting in osteoarthritis. Early treatment of FAI involves arthroscopic or open removal of bone from the anterior femoral neck, as well as repair or removal of labral tears. However, once osteoarthritis has developed, hip replacement or hip resurfacing is indicated. Hip resurfacing can re-orient the head and re-shape the neck. This helps to restore normal biomechanics to the hip, eliminate FAI, and improve range of motion. Since many younger men with hip arthritis have FAI, and are also considered the best candidates for hip resurfacing, it is evident that resurfacing has a role in these patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1231 - 1237
1 Sep 2010
Santori FS Santori N

Bone preservation and physiological distribution of forces on the proximal femur are key elements in introducing a successful uncemented total hip replacement. In order to achieve this, in the mid 1990s, we developed an ultra short proximal loading custom-made component with a lateral flare, a high femoral neck osteotomy and without a diaphyseal stem.

We report the outcome of 129 custom-made hydroxyapatite-coated uncemented short femoral components inserted into 109 patients between June 1995 and May 2004. The mean age of the patients was 51 years (21 to 71) and the mean follow-up was eight years (4.9 to 14.1). Bone behaviour around the implant was studied on the post-operative radiographs. The mean Harris hip score improved from 44 (8 to 66) pre-operatively to 95 (76 to 100) at final follow-up. The Western Ontario MacMaster University Osteoarthritis index was 93 of 100 at final review. None of the patients reported thigh pain. A total of five hips were revised, three for polyethylene liner exchange and two for complete revision of the acetabular component. No femoral components were revised. The radiological changes in the proximal femur were generally good, as evidenced by spot welds both on the medial and lateral aspects of the femur. No component migrated. The presence of a lateral flare and use of a high osteotomy of the femoral neck provided good clinical and radiological results. The absence of a diaphyseal portion of the stem did not impair stability.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 38 - 46
1 Jan 2010
Langton DJ Jameson SS Joyce TJ Hallab NJ Natu S Nargol AVF

Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clinical and radiological outcomes, metal ion levels, explant studies and lymphocyte transformation tests were performed. A total of 17 patients (3.4%) were identified (all ASR bearings) with adverse reactions to metal debris, for which revision was required. This group had significantly smaller components, significantly higher acetabular component anteversion, and significantly higher whole concentrations of blood and joint chromium and cobalt ions than asymptomatic patients did (all p < 0.001). Post-revision lymphocyte transformation tests on this group showed no reactivity to chromium or cobalt ions. Explants from these revisions had greater surface wear than retrievals for uncomplicated fractures. The absence of adverse reactions to metal debris in patients with well-positioned implants usually implies high component wear.

Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1192 - 1196
1 Sep 2005
Argenson J Ryembault E Flecher X Brassart N Parratte S Aubaniac J

Using radiography and computer tomography (CT) we studied the morphology of 83 hips in 69 Caucasian adults with osteoarthritis secondary to developmental dysplasia of the hip (DDH). A previously published series of 310 hips with primary osteoarthritis was used as a control group. According to the Crowe classification, 33 of the dysplastic hips were graded as class I, 27 as class II and 23 as class III or class IV.

The intramedullary femoral canal had reduced mediolateral and anteroposterior dimensions in all groups compared with the control group. Only in Crowe class II hips was the femoral neck-shaft angle increased. The proximal femur had more anteversion in all the developmental dysplasia of the hip groups, ranging from 2° to 80°. Templated measurement of acetabular dimensions for plain radiography closely matched measurements taken by CT.

The results of our study confirm the observations previously confined to the Japanese population.