One of the main goals of total knee arthroplasty (TKA) is to restore an adequate range of motion. The posterior femoral offset (PFO) may have a significant influence on the final flexion angle after TKA. The purpose of the present study was to compare the conventional, radiologic measurement of the PFO before and after TKA to the intra-operative, navigated measurement of the antero-posterior femoral dimension before and after TKA implantation. 100 consecutive cases referred for end-stage knee osteo-arthritis have been included. Inclusion criteria were the availability of pre-TKA and post-TKA lateral X-rays and a navigated TKA implantation. There was no exclusion criterion.INTRODUCTION
MATERIAL
Hip abductor tears(AT) have long been under-recognized, under-reported and under-treated. There is a paucity of data on the prevalence, morphology and associated factors. Patients with “rotator cuff tears of the hip” that are recognized and repaired during total hip arthroplasty(THA) report comparable outcomes to patients with intact abductor tendons at THA. The study was a retrospective review of 997 primary THA done by a single surgeon from 2012–2022. Incidental findings of AT identified during the anterolateral approach to the hip were documented with patient name, gender, age and diagnosis. The extent and size of the tears of the Gluteus medius and Minimus were recorded. Xrays and MRI's were collected for the 140 patients who had AT and matched 1:1 with respect to age and gender against 140 patients that had documented good muscle quality and integrity.
Spinopelvic mobility describes the change in lumbar lordosis and pelvic tilt from standing to sitting position. For 1° of posterior pelvic tilt, functional cup anteversion increases by 0.75° after total hip arthroplasty (THA). Thus, spinopelvic mobility is of high clinical relevance regarding the risk of implant impingement and dislocation. Our study aimed to 1) determine the proportion of OA-patients with stiff, normal or hypermobile spino-pelvic mobility and 2) to identify clinical or static standing radiographic parameters predicting spinopelvic mobility. This prospective diagnostic cohort study followed 122 consecutive patients with end-stage osteoarthritis awaiting THA. Preoperatively, the Oxford Hip Score, Oswestry Disability Index and Schober's test were assessed in a standardized clinical examination. Lateral view radiographs were taken of the lumbar spine, pelvis and proximal femur using EOS© in standing position and with femurs parallel to the floor in order to achieve a 90°-seated position.
Background. Load transfer to the bone is believed to be more physiological around the short stem in total hip arthroplasty (THA). However, we found unusual bony remodeling around the shortened tapered femoral stem. Methods. Among 121 consecutive THA using the same shortened tapered stem, 25 hips were excluded because the lateral cortex was already disturbed by previous surgery on the proximal femur. Sixteen hips were also excluded either because direct measurement was unavailable due to improperly taken final radiographs (n=9) or the patient was lost to follow-up (n=7).80 THAs were finally enrolled.
Introduction. Anterior knee pain (AKP) is a recognized cause of patient's dissatisfaction after total knee arthroplasty. Potential implant/technique related contributors to AKP are patellofemoral maltracking, trochlear geometry, femoral malrotation, patellar tilt and overstuffing. The primary aim of this prospective, matched pair study was to assess the safety, efficacy and performance of an anatomic patella and its effect on AKP in in a matched pair analysis. Material and Methods. Between July 2012 and May 2013, 55 consecutive posterior stabilized cemented Attune TKAs (Depuy) were matched to the PFC Sigma group based on age, gender, and body mass index (BMI). All surgeries were performed via medial parapatellar approach with patellar resurfacing. Clinical and radiographic analysis was performed prospectively with minimum 6 month follow-up.
Background. Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may come have significant learning curves. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual THA during the learning curve. Methods. Three types of THAs were compared in this retrospective cohort: 1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior, FA) done by a posterior surgeon learning the anterior approach, 2) the first 100 robotic assisted posterior THAs done by a surgeon learning robotic assisted surgery (robotic posterior, RP) and 3) the last 100 manual posterior THAs done by each surgeon (total 200 THAs) prior to adoption of novel techniques (manual posterior, MP). Component position was measured on plain radiographs.
Introduction. Stiffness after total knee arthroplasty (TKA) has been reported to occur due to component malpositioning and/or oversizing, improper femoral component (FC) flexion and tibial component (TC) slope, tight extension gap, inaccurate joint line placement, deficient posterior osteophyte resection, heterotopic ossification (HO), poor patellofemoral joint reconstruction, poor posterior condylar offset restoration, and/or posterior cruciate ligament (PCL) under-resection or retraction. However, the importance of these potential factors for stiffness are not well documented in the medical literature. The aim of this study was therefore to evaluate specific radiographic parameters in patients who had stiffness after primary TKA. Material and Methods. An IRB-approved retrospective chart review was performed to identify patients that were revised due to stiffness after TKA. We defined stiffness as 15º or more of flexion contraction, less than 75º of flexion or a range of motion (ROM) of 90º with the chief complaint of limited ROM and pain. Patients with history of previous revisions and/or ORIF, infection, or isolated polyethylene exchange were excluded. Patients with a minimum of 1 year radiographic follow-up were included.
Introduction. Mechanically aligned total knee arthroplasty(TKA) relies on restoring the hip-knee-ankle angle of the limb to neutral or as close to a straight line as possible. This principle is based on studies that suggest limb and knee alignment is related long term survival and wear. For that cause, there has been recent attention concerning computer-assisted TKA and robot is also one of the most helpful instruments for restoring neutral alignment as known. But many reported data have shown that 20% to 25% of patients with mechanically aligned TKA are dissatisfied. Accordingly, kinematically aligned TKA was implemented as an alternative alignment strategy with the goal of reducing prevalence of unexplained pain, stiffness, and instability and improving the rate of recovery, kinematics, and contact forces. So, we want to report our extremely early experience of robot-assisted TKA planned by kinematic method. Materials and Methods. This study evaluated the very short term results (6 weeks follow up) after robot-assisted TKA aligned kinematically. 50 knees in 36 patients, who could be followed up more than 6 weeks after surgery from December 2014 to January 2015, were evaluated prospectively. The diagnosis was primary osteoarthritis in all cases. The operation was performed with ROBODOC (ISS Inc., CA, USA) along with the ORTHODOC (ISS Inc., CA, USA) planning computer. The cutting plan was made by single radius femoral component concept, each femoral condyles shape-matched method along the transverse axis using multi-channel CT and MRI to place the implant along the patient's premorbid joint line.
Objective. The aim of this retrospective study is to assess the functional and radiological outcome of a multi-planar corrective osteotomy, distraction and locking fixed angle volar plate as the standard of treatment of distal radius mal-unions that require multi-planar correction. Methods. We conducted a retrospective study on 13 consecutive patients – 4 males, 9 females (mean age 49). All patients underwent volar approach, open wedge distraction osteotomy locking fixed angle volar plate and cancellous bone grafting
ACL reconstruction is successful in restoring sagittal stability of the knee but has been less consistent in restoring rotational stability. Increasing coronal graft obliquity improves rotational constraint of the knee in cadaveric biomechanical models. The purpose of this study was to determine whether there is a correlation between coronal graft alignment and tibial rotation during straight line activities. Seventy-four patients who had undergone ACL reconstruction using a transtibial technique were evaluated. They came from three distinct time periods during which the operating surgeon had deliberately changed the position of the femoral tunnel to progressively achieve a more oblique graft alignment in the coronal plane. Post-operative radiographs were analyzed for the coronal graft orientation and femoral and tibial tunnel positions. Tibial rotation was measured during level walking (n=74) and single-limb landing (n=42) tasks using a motion analysis system.
Pelvic incidence is as a key factor for sagittal balance regulation that describes the anatomical configuration of the pelvis. The sagittal alignment of the pelvis is usually evaluated in two-dimensional (2D) sagittal radiographs in standing position by pelvic parameters of sacral slope, pelvic tilt and pelvic incidence (PI). However, the angle of PI remains constant for an arbitrary subject position and orientation, and can be therefore compared among subjects in standing, sitting or supine position. Such properties also enable the measurement of PI in three-dimensional (3D) images, commonly acquired in supine position. The purpose of this study is to analyse the sagittal alignment of the pelvis in terms of PI in 3D computed tomography (CT) images. A computerised method based on image processing techniques was developed to determine the anatomical references, required to measure PI, i.e. the centre of the left femoral head, the centre of the right femoral, the centre of the sacral endplate, and the inclination of the sacral endplate. First, three initialisation points were manually selected in 3D at the approximate location of the left femoral head, right femoral head and L5 vertebral body. The computerised method then determined the exact centres of the femoral heads in 3D from the spheres that best fit to the 3D edges of the femoral heads. The exact centre of the sacral endplate in 3D was determined by locating the sacral endplate below the L5 vertebral body and finding the midpoint of the lines between the anterior and posterior edge, and between the left and right edge of the endplate. The exact inclination of the sacral endplate in 3D was determined from the plane that best fit to the endplate. Multiplanar 3D image reformation was applied to obtain the superposition of the femoral heads in the sagittal view, so that the hip axis was observed as a straight not inclined line and all anatomical structures were completely in line with the hip axis. Finally, PI was automatically measured as the angle between the line orthogonal to the inclination of the sacral endplate and the line connecting the centre of the sacral endplate with the hip axis. The method was applied to axially reconstructed CT scans of 426 subjects (age 0–89 years, pixel size 0.4–1.0 mm, slice thickness 3.0–4.0 mm). Thirteen subjects were excluded due to lumbar spine trauma and presence of the sixth lumbar segment. For the remaining subjects, the computerised measurements were visually assessed for errors, which occurred due to low CT image quality, low image intensity of bone structures, or other factors affecting the determination of the anatomical references. The erroneous or ambiguous results were detected for 43 subjects, which were excluded from further analysis. For the final cohort of 370 subjects, statistical analysis was performed for the obtained PI. The resulting mean PI ± standard deviation was equal to 46.6 ± 9.2 degrees for males (N = 189, age 39.7 ± 20.3 years), 47.6 ± 10.7 degrees for females (N = 181, age 43.4 ± 19.9 years), and 47.1 ± 10.0 degrees for both genders (N = 370, age 41.5 ± 20.1 years). Correlation analysis yielded relatively low but statistically significant correlation between PI and age, with the correlation coefficient r = 0.20 (p < 0.005) for males, r = 0.32 (p < 0.0001) for females, and r = 0.27 (p < 0.0001) for both genders. No statistically significant differences (p = 0.357) were found between PI for male and female subjects. This is the first study that evaluates the sagittal alignment of the pelvis in terms of PI completely in 3D. Studies that measured PI manually from 2D sagittal radiographs reported normative PI in adult population of 52 ± 10 degrees, 53 ± 8 degrees and 51 ± 9 degrees for 25 normal subjects aged 21–40, 41–60, and over 60 years, respectively [3], and 52 ± 5 degrees for a cohort of 160 normal subjects [4]. The PI of 47 ± 10 degrees obtained in our study is lower than the reported normative values, which indicates that radiographic measurements may overestimate the actual PI.