Advertisement for orthosearch.org.uk
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 630 - 637
1 May 2012
Bourke HE Gordon DJ Salmon LJ Waller A Linklater J Pinczewski LA

The purpose of this study was to report the outcome of ‘isolated’ anterior cruciate ligament (ACL) ruptures treated with anatomical endoscopic reconstruction using hamstring tendon autograft at a mean of 15 years (14.25 to 16.9). A total of 100 consecutive men and 100 consecutive women with ‘isolated’ ACL rupture underwent four-strand hamstring tendon reconstruction with anteromedial portal femoral tunnel drilling and interference screw fixation by a single surgeon. Details were recorded pre-operatively and at one, two, seven and 15 years post-operatively. Outcomes included clinical examination, subjective and objective scoring systems, and radiological assessment. At 15 years only eight of 118 patients (7%) had moderate or severe osteo-arthritic changes (International Knee Documentation Committee Grades C and D), and 79 of 152 patients (52%) still performed very strenuous activities. Overall graft survival at 15 years was 83% (1.1% failure per year). Patients aged < 18 years at the time of surgery and patients with > 2 mm of laxity at one year had a threefold increase in the risk of suffering a rupture of the graft (p = 0.002 and p = 0.001, respectively). There was no increase in laxity of the graft over time.

ACL reconstructive surgery in patients with an ‘isolated’ rupture using this technique shows good results 15 years post-operatively with respect to ligamentous stability, objective and subjective outcomes, and does not appear to cause osteoarthritis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 42 - 42
1 Mar 2012
Hakimi M Anand S Sahu A Johnson D Turner P
Full Access

The aim of this study was to determine current practice in anterior cruciate ligament reconstruction amongst BASK members. This was an internet-based survey where members were invited to complete a questionnaire on ACL reconstruction. Of the 365 BASK surgeons performing ACL reconstruction, 241 completed the questionnaire (response rate 66%). 147(61%) of surgeons used both hamstring and patellar tendon grafts, 71(29%) used only hamstrings and 21(9%) used patellar tendon only. All surgeons used ipsilateral autograft. 157 (65%) used the transtibial technique for femoral tunnel placement with 80(33%) using the anteromedial portal technique. Of those using the anteromedial portal, the most common femoral fixation devices were the Endobutton (34%) and RCI screw (34%). Interference screw fixation (81%) was the most common tibial fixation in the same group of surgeons with the RCI screw being the most common (63%). 19% (45/241) of surgeons were performing double bundle ACL reconstructions in select cases. Hamstring femoral fixation was with a suspension device in 79% and interference screw in 18%. Of those using a suspension device the Endobutton was most common (48%) followed by Transfix (26%) and Rigidfix (19%). Tibial fixation was most commonly achieved by interference screw (57%) followed by Intrafix (30%). With patellar tendon graft the most popular femoral fixation was with an interference screw (66%) followed by suspension (34%). All surgeons used interference screw for tibial fixation. 90% of surgeons (217) allow immediate full weight-bearing as tolerated irrespective of fixation type with 8% delaying full weight bearing between 1 and 3 weeks. The results show the wide spread of variation in practice of ACL reconstruction. With recent renewed interest in a more anatomic placement of tunnels, the use of the anteromedial portal may continue to increase. With such a wide variation in techniques, grafts and fixation implants used, a register may help assess outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1328 - 1333
1 Oct 2008
Jackson WFM van der Tempel WM Salmon LJ Williams HA Pinczewski LA

We evaluated the long-term outcome of isolated endoscopically-assisted posterior cruciate ligament reconstruction in 26 patients using hamstring tendon autografts after failure of conservative management. At ten years after surgery the mean International Knee Documentation Committee subjective knee score was 87 (sd 14) of a possible 100 points. Regular participation in moderate to strenuous activities was possible for only seven patients pre-operatively; this increased to 23 patients post-operatively. The mean Lysholm score improved from 64 (sd 15) to 90 (sd 14) at ten years (p = 0.001).

At ten years endoscopic reconstruction of the posterior cruciate ligament with hamstring tendon autograft is effective in reducing knee symptoms. Of the series, 22 patients underwent radiological assessment for the development of osteoarthritis using the Kellgren-Lawrence grading scale. In four patients, grade 2 changes with loss of joint space was observed and another four patients showed osteophyte formation with moderate joint space narrowing (grade 3). These findings compared favourably with non-operatively managed injuries of the posterior cruciate ligament.

This procedure for symptomatic patients with posterior cruciate ligament laxity who have failed conservative management offers good results.


Bone & Joint Research
Vol. 1, Issue 10 | Pages 234 - 237
1 Oct 2012
Hughes AW Dwyer AJ Govindaswamy R Lankester B

Objectives

Our aim was to assess the use of intra-operative fluoroscopy in the assessment of the position of the tibial tunnel during reconstruction of the anterior cruciate ligament (ACL).

Methods

Between January and June 2009 a total of 31 arthroscopic hamstring ACL reconstructions were performed. Intra-operative fluoroscopy was introduced (when available) to verify the position of the guidewire before tunnel reaming. It was only available for use in 20 cases, due to other demands on the radiology department. The tourniquet times were compared between the two groups and all cases where radiological images lead to re-positioning of the guide wire were recorded. The secondary outcome involved assessing the tibial interference screw position measured on post-operative radiographs and comparing with the known tunnel position as shown on intra-operative fluoroscopic images.