Advertisement for orthosearch.org.uk
Results 1 - 20 of 21
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 68 - 68
7 Nov 2023
Hohmann E Paschos N Keough N Molepo M Oberholster A Erbulut D Tetsworth K Glat V Gueorguiev B
Full Access

The purpose of this study was to develop a quality appraisal tool for the assessment of laboratory basic science biomechanical studies.

Materials andScore development comprised of the following phases: item identification/development, item reduction, content/face/criterion validity, weighting, test-retest reliability and internal consistency. For item identification/development, the panel was asked to independently list criteria and factors they considered important for cadaver study and generate items that should be used to appraise cadaver study quality. For content validity, the content validity ratio (CVR) was calculated. The minimum accepted content validity index (CVI) was set to 0.85. For weighting, equal weight for each item was 6.7% [15 items]. Based on these figures the panel was asked to either upscale or downscale the weight for each item ensuring that the final sum for all items was 100%. Face validity was assessed by each panel member using a Likert scale from 1–7. Strong face validity was defined as a mean score of >5. Test-retest reliability was assessed using 10 randomly selected studies. Criterion validity was assessed using the QUACS scale as standard. Internal consistency was assessed using Cronbach's alpha.

Five items reached a CVI of 1 and 10 items a CVI of 0.875. For weighting five items reached a final weight of 10% and ten items 5%. The mean score for face validity was 5.6. Test-retest reliability ranged from 0.78–1.00 with 9 items reaching a perfect score. Criterion validity was 0.76 and considered to be strong. Cronbach's alpha was calculated to be 0.71 indicating acceptable internal consistency.

The new proposed quality score for basic science studies consists of 15 items and has been shown to be reliable, valid and of acceptable internal consistency. It is suggested that this score should be utilised when assessing basic science studies.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 11 - 11
1 Jul 2020
Schaeffer E Ghoto A Ahmad D Habib E Mulpuri K
Full Access

Systematic reviews (SR) can provide physicians with effective means to further strengthen their practice and identify gaps in clinical knowledge. The focus of any SR is to identify the current state of evidence for a given treatment or condition, with the hopes of providing the best interventional methods physicians can base their practice on. In paediatric orthopaedics, high-level studies are lacking, thus potentially limiting the effectiveness of SRs in the field. There isn't one specific way to qualify research on its effectiveness, but there has been gradual enhancement in finding ways to identify a successful and reproducible study. The purpose of this study was to evaluate the quality of paediatric orthopaedic SRs, and highlight aspects of these SRs that have contributed to improved outcomes.

A literature review was performed in EMBASE, MEDLINE and Cochrane databases to identify pre-existing systematic reviews that have been published in five well-known orthopaedic journals between 2007 and 2017. SRs were included if the study population was between 0 and 18 years of age. Selected articles had an AMSTAR checklist applied in order to score the studies on their quality and methodology. Articles were independently reviewed by two reviewers to determine the extent of AMSTAR guidelines fulfillment.

A total of 40 SRs were identified and reviewed, 20 of which partially or completely fulfilled AMSTAR guidelines. There was no disagreement between reviewers as to which of the analyzed articles have successfully reflected the checklist.

Only 20/40 SRs analyzed at least partially fulfilled AMSTAR guidelines. One of the weaknesses identified in the reviewed papers so far is the lack of justification for the chosen study designs for SRs and what strategy was used to decide on the exclusion of articles. There needs to be clear-cut criteria that mark studies to be included and excluded in a comprehensive systematic review. Further improvements are required to ensure that full details on the involvement of papers and the success rates regarding each interventional method are included in order to strengthen the quality of SRs across the paediatric orthopaedic literature.


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 19 - 23
1 Jan 2014
Sabharwal S Gauher S Kyriacou S Patel V Holloway I Athanasiou T

We evaluated the quality of guidelines on thromboprophylaxis in orthopaedic surgery by examining how they adhere to validated methodological standards in their development. A structured review was performed for guidelines that were published between January 2005 and April 2013 in medical journals or on the Internet. A pre-defined computerised search was used in MEDLINE, Scopus and Google to identify the guidelines. The AGREE II assessment tool was used to evaluate the quality of the guidelines in the study.

Seven international and national guidelines were identified. The overall methodological quality of the individual guidelines was good. ‘Scope and Purpose’ (median score 98% interquartile range (IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%, IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’ (median score 68%, IQR 45% to 75%) and ‘Editorial Independence’ (median score 71%, IQR 68% to 75%) had the lowest scores.

These findings reveal that although the overall methodological quality of guidelines on thromboprophylaxis in orthopaedic surgery is good, domains within their development, such as ‘Applicability’ and ‘Editorial Independence’, need to be improved. Application of the AGREE II instrument by the authors of guidelines may improve the quality of future guidelines and provide increased focus on aspects of methodology used in their development that are not robust.

Cite this article: Bone Joint J 2014;96-B:19–23.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 46 - 46
1 Dec 2017
Esfandiari H Anglin C Street J Guy P Hodgson A
Full Access

Pedicle screw fixation is a technically demanding procedure with potential difficulties and reoperation rates are currently on the order of 11%. The most common intraoperative practice for position assessment of pedicle screws is biplanar fluoroscopic imaging that is limited to two- dimensions and is associated to low accuracies. We have previously introduced a full-dimensional position assessment framework based on registering intraoperative X-rays to preoperative volumetric images with sufficient accuracies. However, the framework requires a semi-manual process of pedicle screw segmentation and the intraoperative X-rays have to be taken from defined positions in space in order to avoid pedicle screws' head occlusion. This motivated us to develop advancements to the system to achieve higher levels of automation in the hope of higher clinical feasibility.

In this study, we developed an automatic segmentation and X-ray adequacy assessment protocol. An artificial neural network was trained on a dataset that included a number of digitally reconstructed radiographs representing pedicle screw projections from different points of view. This model was able to segment the projection of any pedicle screw given an X-ray as its input with accuracy of 93% of the pixels. Once the pedicle screw was segmented, a number of descriptive geometric features were extracted from the isolated blob. These segmented images were manually labels as ‘adequate’ or ‘not adequate’ depending on the visibility of the screw axis. The extracted features along with their corresponding labels were used to train a decision tree model that could classify each X-ray based on its adequacy with accuracies on the order of 95%.

In conclusion, we presented here a robust, fast and automated pedicle screw segmentation process, combined with an accurate and automatic algorithm for classifying views of pedicle screws as adequate or not. These tools represent a useful step towards full automation of our pedicle screw positioning assessment system.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 500 - 500
1 Dec 2013
Klotz M Beckmann N Reiner T Jaeger S Bitsch R
Full Access

In cases of poor bone quality intraoperative torque measurement might be an alternative to preoperative dual energy x-ray absorptiometry (DXA) to assess bone quality in Total Hip Arthroplasty (THA). 14 paired fresh frozen human femurs were included for trabecular peak torque measurement. We evaluated an existing intraoperative torque measurement method to assess bone quality and bone strength. We modified the approach to use this method in total hip arthroplasty (THA), which has not been published before. Since there are several approaches used in THA to exposure the hip joint, we decided to prefer the measurement in the femoral head which allows every surgeon to perform this measurement. Here a 6.5 × 23 mm blade was inserted into the proximal femur without harming the lateral cortical bone (figure 1). Further tests of the proximal femur evaluated the results of this new method: DXA, micro-computed tomography (μCT) and biomechanical load tests. Basic statistical analyses and multiple regressions were done. In the femoral head mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT and the biomechanical load test. In comparison to the bone mineral density captured by DXA, the results of the intraoperative torque measurement showed a superior correlation with high sensitive bone quality evaluating methods (mechanical load tests and micro-computed tomography). Hence, the use of this intraoperative torque measurement seems to be more accurate in evaluating bone strength and bone quality than DXA during THA. The torque measurement provides sensitive information about the bone strength, which may affect the choice of implant in cases of poor bone stock and osteoporosis. In clinical use the surgeon may alter the prosthesis if the device indicates poor bone quality. Furthermore, we assume that the disadvantages associated with DXA scans like radiation exposure or errors caused by potential extraosteal sclerosis and interindividual soft-tissue artifacts could be excluded.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 65 - 65
24 Nov 2023
Schindler M Walter N Sigmund IK Maderbacher G Alt V Rupp M
Full Access

Background. The identification of novel biomarker which is highly specific and sensitive for periprosthetic joint (PJI) have the potential to improve diagnostic accuracy and ultimately improve patient outcomes. Thus, the aim of this systemic review is to identify and evaluate novel biomarkers for the preoperative diagnostics of PJI. Methods. MEDLINE, EMBASE, PubMed and Cochrane Library databases identified from 1. st. of January 2018 to 30. th. of September. 2022. We used “periprosthetic joint infection” OR “prosthetic joint infection” OR “periprosthetic infection” as the diagnosis of interest and the target index applied AND “marker”. To focus on novel biomarkers already used biomarkers of the established PJI diagnostic criteria of MSIS, ICM and EBJIS were not included in the analysis. These three criteria were considered the reference standard during quality assessment. Results. A total of 19 studies were included. In these, fourteen different novel biomarkers were analyzed. Fifteen studies (79%) had prospective designs and the other four (22%) were retrospective studies. Six studies (33%) included only periprosthetic knee infections and thirteen (67%) included periprosthetic knee and hip infections. Proteins were analyzed in most cases (nine studies), followed by molecules (three studies), exosome (two studies) as well as DNA (two studies), interleukin (one study) and lysosome (one study). One novel and promising marker that had been frequently analyzed is calprotectin. Conclusion. No marker demonstrated higher sensitivity and specificity than already known parameters used for standardized treatment based on established PJI definitions. Further studies are needed to elucidate the benefit and usefulness of implementing new biomarkers in diagnostic PJI settings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 44 - 44
24 Nov 2023
Bruyninckx S Vles G
Full Access

Aim. The objective of this systematic review is to evaluate the current evidence for or against this up-and-coming treatment modality. Method. A comprehensive literature search in accordance with the Preferred Reporting Items for Systematic review and Meta-analysis (PRISMA) guidelines was conducted using PubMed, Embase, MEDLINE and Cochrane databases. Exclusion criteria included patients < 18 years of age, follow-up <11 months, and a score < 6 on the National Institute of Health quality assessment tool. Results. 15 articles, encompassing 631 PJIs in 626 patients, were included in the final analysis, all level IV case series. The quality of many studies was impeded by a retrospective design (14/15), a relative small study population (10 out of 15 studies had less than 50 patients), selection bias, and remarkable heterogeneity in terms of catheter type, antibiotic type, dose and duration of IA antibiotics and techniques of surgical revision. 347 were chronic infections, 66 acute infections and 218 unknown. The majority was treated with single-stage revision with adjuvant IA antibiotic infusion (499/631, 79.1%). The remaining PJIs were treated with stand-alone IA antibiotic infusion (77/631, 12.2%), DAIR with adjuvant IA antibiotic infusion (36/631, 5.7%) or two-stage revision with adjuvant IA antibiotic infusion (19/631, 3.0%). Mean duration of IA antibiotic infusion was 19 days (range 3–50), although most patients received a combination of both IA and systemic (IV or PO) antibiotics. An overall failure rate (defined as failures of infection eradication/total PJIs) of approximately 11% was found. The use of IA antibiotic infusion as a stand-alone treatment was associated with a higher failure rate. In total 117 complications occurred in 631 cases (18.5%). Of these, 71 were non-catheter-related (60.7%) and 46 were catheter-related (39.3%). The most common catheter-related complications were premature loss of the catheter (18/46), developing a fistula (5/46), and elevated blood urea nitrogen (BUN) and creatinine levels (12/46). Conclusions. Due to the lack of comparative studies the (added) benefit of IA antibiotic infusion in the treatment of PJI remains uncertain. From a theoretical point of view it seems likely that is should not be used as a stand-alone treatment. A prospective randomized controlled trial using a well-described infusion protocol is needed to see if the potential benefits justify the increased costs, labour and catheter-related complications of this treatment modality


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 97 - 97
1 Jul 2020
Khan M Liu EY Hildebrand AH Athwal G Alolabi B Horner N
Full Access

Heterotopic Ossification (HO) is a known complication that can arise after total elbow arthroplasty (TEA). In most cases it is asymptomatic, however, in some patients it can limit range of motion and lead to poor outcomes. The objective of this review was to assess and report incidence, risk factors, prophylaxis, and management of HO after TEA. A systematic search was conducted using MEDLINE, EMBASE, and PubMed to retrieve all relevant studies evaluating occurrence of HO after TEA. The search was performed in duplicate and a quality assessment was performed of all included studies. A total of 1907 studies were retrieved of which 45 studies were included involving 2256 TEA patients. HO was radiographically present in 10% of patients and was symptomatic in 3%. Less than 1% of patients went on to surgical excision of HO, with outcomes following surgery reported as good or excellent as assessed by range of motion and Mayo Elbow Performance Scores (MEPS). TEA due to ankylosis, primary osteoarthritis, and posttraumatic arthritis are more likely to develop symptomatic HO. HO is an uncommon complication following TEA with the majority of patients developing HO being asymptomatic and requiring no surgical management. Routine HO prophylaxis for TEA is not supported by the literature. The effectiveness of prophylaxis in high risk patients is uncertain and future studies are required to clarify its usefulness. The strength of these conclusions are limited by inconsistent reporting in the available literature


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 1 - 1
1 Jul 2020
Paul R Maldonado-Rodriguez N Docter S Leroux T Khan M Veillette C Romeo A
Full Access

Reverse total shoulder arthroplasty (RSA) with glenoid bone grafting has become a common option for the management of significant glenoid bone loss and deformity associated with glenohumeral osteoarthritis. Despite the increasing utilization of this technique, our understanding of the rates of bone graft union, complications and outcomes are limited. The objectives of this systematic review are to determine 1) the overall rate of bone graft union, 2) the rate of union stratified by graft type and technique, 3) the reoperation and complication rates, and 4) functional outcomes, including range of motion (ROM) and functional outcome scores following RSA with glenoid bone grafting. A comprehensive search of MEDLINE, Embase, and CINAHL databases was completed for studies reporting outcomes following RSA with glenoid bone grafting. Inclusion criteria included clinical studies with greater than 10 patients, and minimum follow up of one year. Studies were screened independently by two reviewers and quality assessment was performed using the MINORs criteria. Pooled and frequency-weighted means and standard deviations were calculated where applicable. Overall, 15 studies were included, including nine retrospective case series (level IV), four retrospective cohort studies (level III), one prospective cohort study (level II) and one randomized control trial (level I). The entire cohort consisted of 555 patients with a mean age of 71.9±2.1 years and 70 percent female. The mean follow-up was 33.8±9.4 months. Across all procedures, 84.9% (N=471) were primary arthroplasties, and 15.1% (N=84) were revisions. The overall graft union rate was 89.2%, but was higher at 96.1% among studies that used autograft bone (9 studies, N=308). When stratified by technique, bone graft for the purposes of lateralization resulted in a 100% union rate (4 studies, N=139), while eccentric bone grafts used in asymmetric bone loss resulted in a lower union rate of 84.9% (10 studies, N=345). The overall revision rate was 6.5%, and was lowest following primary cases at 1.8% (11 studies, N=393). The pooled mean scapular notching rate was 20.1% (12 studies, N=497). Excluding notching, the pooled mean complication rate was 21.5% for all cases and 13% for primary cases (11 studies, N=393). When reported, there was significant improvement in post-operative ROM in all planes. There was also improvement in functional outcome scores, whereby the frequency-weighted mean Constant score increased from 25.9 to 67.2 (8 studies, N=319), ASES score increased from 34.7 to 75.2 (4 studies, N=142), and SST score increased from 2.1 to 7.6 (5 studies, N=196) at final follow up. This review demonstrates that glenoid bone grafting with RSA results in good mid-term clinical and radiographic outcomes. Union rate appears to depend highly on graft type and technique, whereby the highest union rates were seen following the use of autograft bone for the purposes of lateralization. Interestingly, the union rate of autograft bone for the purposes of augmentation in eccentric bone loss is considerably lower and its impact on the long-term survivorship of the implant remains unknown


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 34 - 34
1 Apr 2019
Chang MJ Kang SB Chang CB Yoon C Kim W Shin JY Suh DW Oh JB Kim SJ Choi SH Kim SJ Baek HS
Full Access

The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) remains controversial, even though SONK usually involves only medial compartment of the knee joint. We aimed to compare the survival rate and clinical outcomes of UKA in SONK and medial compartment osteoarthritis (MOA) via a meta-analysis of previous studies. MEDLINE database in PubMed, the Embase database, and the Cochrane Library were searched up to January 2018 with keywords related to SONK and UKA. Studies were selected with predetermined inclusion criteria: (1) medial UKA as the primary procedure, (2) reporting implant survival or clinical outcomes of osteonecrosis and osteoarthritis, and (3) follow-up period greater than 1 year. Quality assessment was performed using the risk of bias assessment tool for non-randomised studies (RoBANs). A random effects model was used to estimate the pooled relative risk (RR) and standardised mean difference. The incidence of UKA revision for any reason was significantly higher in SONK than in MOA group (pooled RR = 1.83, p = 0.009). However, the risk of revision due to aseptic loosening and all- cause re-operation was not significantly different between the groups. Moreover, when stratified by the study quality, high quality studies showed similar risk of overall revision in SONK and MOA (p = 0.71). Subgroup analysis revealed worse survival of SONK, mainly related to high failure after uncemented UKA. Clinical outcomes after UKA were similar between SONK and MOA (p = 0.66). Cemented UKA has similar survival and clinical outcomes in SONK and MOA. Prospective studies designed specifically to compare the UKA outcomes in SONK and MOA are necessary


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 11 - 11
1 Apr 2019
Wong M Desai B Bautista M Kwon O Chimento G
Full Access

PURPOSE. YouTube is a video sharing platform that is a common resource for patients seeking medical information. The objective of this study is to assess the educational quality of YouTube videos pertaining to total knee arthroplasty and knee arthritis. METHODS. A systematic search for the terms “knee replacement” and “knee arthritis” was performed using Youtube's search function. Data from the 60 most relevant videos were collected for each search term. Videos not in English or those without audio or captions were excluded. Quality assessment checklists with a scale of 0 to 10 points were developed to evaluate the video content. Videos were grouped into poor quality (grade 0–3), acceptable quality (grade 4–7) and excellent quality (grade 8– 10), respectively. Four independent reviewers assessed the videos using the same grading system and independently scored all videos. Discrepancies regarding the scoring were clarified by consensus discussion. RESULTS. Overall 106 videos were categorized. For videos regarding total knee replacements, the average number of views was 135,074 with an average duration of 14.53 minutes. Half of the videos were published by a physician or hospital sponsor and were for educational purposes. 64% of videos were of poor educational quality (32/50), 28% were of acceptable quality (14/50), and 8% were of good educational quality (4/50). Common missing information included discussion of surgical complications and implant duration. For videos regarding knee arthritis, the average number of views was 243,346 with an average duration of 4.97 minutes. 39% were published by a physician or hospital sponsor, with 64% of videos made for educational purposes. 66% of videos were of poor educational quality (37/56), 32% were of acceptable quality (18/56), and 2% were of good educational quality. The most common missing information were causes and risk factors for knee arthritis and long-term prognosis. CONCLUSIONS. The present study suggests that YouTube is a poor educational source for patients regarding knee arthroplasty and knee arthritis. Recognizing the limitations of YouTube as well as which topics are not commonly presented may guide clinicians to better educate their patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 78 - 78
1 Dec 2018
Pincher B Fenton C Jeyapalan R Barlow G Sharma H
Full Access

Aim. Despite advances in surgical and antibiotic therapies the treatment of chronic osteomyelitis remains complex and is often associated with a significant financial burden to the National Health Service. The aim of this review was to identify the different types of single-stage procedures being performed for this condition as well as to evaluate their effectiveness. Method. Ovid Medline and Embase databases were searched for articles on the treatment of chronic osteomyelitis over the last 20 years. 3511 journal abstracts were screened by 3 independent reviewers. Following the exclusion of paediatric subjects, animal models, non-bacterial osteomyelitis and patients undergoing multiple surgical procedures we identified 13 studies reported in English with a minimum follow up of 12 months. Following a quality assessment of each study, data extraction was performed and the results analysed. Results. 505 patients with chronic osteomyelitis underwent attempted single-stage procedures. Following debridement a range of techniques are described to eliminate the remaining dead space. These include musculocutaneous flaps, insertion of S53P4 glass beads or packing with antibiotic loaded ceramic or calcium-sulphate pellets. The average follow-up ranged from 12 to 110 months. The most common organism isolated was Staphylococcus Aureus. Success was defined as resolution of pain with no recurrence of sinuses and no need for a second procedure to treat infection. Success rates ranged from 60%-100%. Conclusions. There are currently a wide range of single-stage procedures being performed for chronic osteomyelitis with varying success rates. Treating patients with these methods in specialist centres can result in resolution of infection and may lead to improved quality of life for the patient and a financial saving for the National Health Service. So far no one technique has been shown to be superior and further long term follow up data is required


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 75 - 75
1 Dec 2018
van den Kieboom J Bosch P Plate J IJpma F Leenen L Kühl R McNally M Metsemakers W Govaert G
Full Access

Aim. Fracture related infection (FRI) remains a challenging diagnosis in orthopedic and trauma surgery. In addition to clinical signs and imaging, serum inflammatory markers are often used to estimate the probability of FRI. To what extent serum inflammatory markers can be used to rule out and diagnose FRI remains unclear. The aim of this systematic review was to assess the diagnostic value of the serum inflammatory markers C-reactive protein (CRP), leukocyte count (LC) and erythrocyte sedimentation rate (ESR) in suspected fracture related infection. Method. PubMed, Embase and Cochrane databases were searched for all articles focusing on the diagnostic value of CRP, LC and ESR in FRI. Studies on other inflammatory markers or other types of orthopedic infection, such as periprosthetic and diabetic foot infections, were excluded. For each serum inflammatory marker, all reported sensitivity and specificity combinations were extracted and graphically visualized. Average estimates were obtained using bivariate mixed effects models. This study utilized the QUADAS-2 criteria and was reported following the PRISMA statement. Results. The search resulted in 8280 articles, of which seven were eligible for inclusion. One study was excluded after quality assessment. CRP was reported in all included studies, with sensitivity ranging from 60.0 to 100.0% and specificity from 34.3 to 85.7%. Five of these studies were pooled. The average pooled sensitivity and specificity of CRP were, respectively, 77.0% (95% CI 66.5–85.0%) and 67.9% (95% CI 38.7–87.6%). LC was reported in five studies. Sensitivity ranged from 22.9 to 72.6% and specificity from 73.5 to 85.7%. The results of four of these studies were pooled, resulting in a 51.7% (95% CI 27.2–75.5%) sensitivity and 67.1% (95% CI 19.3–50.2%) specificity. ESR was reported in five studies. Sensitivity and specificity ranged from 37.1 to 100.0% and 59.0 to 85.0% respectively. Three of these studies were pooled, showing a 45.1% (95% CI 37.8–52.6%) sensitivity and 79.3% (95% CI 71.7–85.2%) specificity of ESR. Four studies analyzed the combined value of inflammatory markers, reporting an increased diagnostic accuracy. These results could not be pooled due to heterogeneity. Conclusions. The serum inflammatory markers CRP, LC and ESR are insufficiently accurate to diagnose FRI. These markers cannot rule out the presence of FRI, but they may be used as a suggestive sign in the diagnosis of FRI


Bone & Joint Open
Vol. 4, Issue 4 | Pages 250 - 261
7 Apr 2023
Sharma VJ Adegoke JA Afara IO Stok K Poon E Gordon CL Wood BR Raman J

Aims

Disorders of bone integrity carry a high global disease burden, frequently requiring intervention, but there is a paucity of methods capable of noninvasive real-time assessment. Here we show that miniaturized handheld near-infrared spectroscopy (NIRS) scans, operated via a smartphone, can assess structural human bone properties in under three seconds.

Methods

A hand-held NIR spectrometer was used to scan bone samples from 20 patients and predict: bone volume fraction (BV/TV); and trabecular (Tb) and cortical (Ct) thickness (Th), porosity (Po), and spacing (Sp).


Bone & Joint Research
Vol. 13, Issue 8 | Pages 411 - 426
28 Aug 2024
Liu D Wang K Wang J Cao F Tao L

Aims

This study explored the shared genetic traits and molecular interactions between postmenopausal osteoporosis (POMP) and sarcopenia, both of which substantially degrade elderly health and quality of life. We hypothesized that these motor system diseases overlap in pathophysiology and regulatory mechanisms.

Methods

We analyzed microarray data from the Gene Expression Omnibus (GEO) database using weighted gene co-expression network analysis (WGCNA), machine learning, and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analysis to identify common genetic factors between POMP and sarcopenia. Further validation was done via differential gene expression in a new cohort. Single-cell analysis identified high expression cell subsets, with mononuclear macrophages in osteoporosis and muscle stem cells in sarcopenia, among others. A competitive endogenous RNA network suggested regulatory elements for these genes.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 628 - 640
1 Aug 2022
Phoon KM Afzal I Sochart DH Asopa V Gikas P Kader D

Aims

In the UK, the NHS generates an estimated 25 megatonnes of carbon dioxide equivalents (4% to 5% of the nation’s total carbon emissions) and produces over 500,000 tonnes of waste annually. There is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. The primary aim of this study was to analyze the environmental impact of orthopaedic surgery and the environmentally sustainable initiatives undertaken to address this. The secondary aim of this study was to describe the barriers to making sustainable changes within orthopaedic surgery.

Methods

A literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines through EMBASE, Medline, and PubMed libraries using two domains of terms: “orthopaedic surgery” and “environmental sustainability”.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 2 - 2
1 Jul 2016
Aujla R Esler C
Full Access

The proportion of younger patients undergoing total knee arthroplasty (TKA) is increasing and predictions state that the 45–54 age group will be the fastest growing group by 2030. We aim to collate data across studies to assess functional outcomes following total knee replacement in patients under 55 years of age. Secondary outcomes include implant survival and complications will also be reviewed. The search identified 980 studies for title and abstract review. 43 full-texts were then assessed. 13 studies underwent quality assessment and data extraction from them. PRISMA guidelines were followed throughout. Outcomes extracted included pre- and post-operative functional scores, range of motion (ROM) and patient satisfaction. Clinical complications and survival were also recorded. Across 13 studies we were able to demonstrate 54-point improvement in clinical Knee Society Score and a 2.9° improvement in range of motion. Satisfaction rate was 85.5%. Revision rate was 5.4% across 1323 TKAs. Risk of revision for aseptic loosening was 0.37% per year. Total knee arthroplasty is an excellent treatment option for the young osteoarthritic knee with a >50% improvement in functional knee scores. Satisfaction is high and the revision rate remains under 1% per year


Bone & Joint Open
Vol. 2, Issue 9 | Pages 721 - 727
1 Sep 2021
Zargaran A Zargaran D Trompeter AJ

Aims

Orthopaedic infection is a potentially serious complication of elective and emergency trauma and orthopaedic procedures, with a high associated burden of morbidity and cost. Optimization of vitamin D levels has been postulated to be beneficial in the prevention of orthopaedic infection. This study explores the role of vitamin D in orthopaedic infection through a systematic review of available evidence.

Methods

A comprehensive search was conducted on databases including Medline and Embase, as well as grey literature such as Google Scholar and The World Health Organization Database. Pooled analysis with weighted means was undertaken.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 189 - 189
1 Sep 2012
Soroceanu A Sidhwa F Kaufman A Aarabi S Glazebrook M
Full Access

Purpose. Surgical repair is the preferred method of treatment of acute Achilles ruptures in North America because, despite a higher risk of overall complications, it offers a reduced risk of re-rupture. However, more recent trials, particularly those using functional bracing with early range of motion (ROM) have challenged this statement. This meta-analysis aims to compare surgical to conservative treatment in respect to re-rupture, overall complications, return to work, calf circumference and functional outcomes, as well as to examine the effects of early ROM on re-rupture rate. Method. Literature search, data extraction, and quality assessment were conducted by two independent reviewers. Publication bias was assessed using the Eggar and Begg tests. Heterogeneity was assessed using I2 tests. Fixed or random-effects models were used accordingly. Pooled results were expressed as risk ratios, risk differences, and weighted or standardized mean difference, as appropriate. Meta-regression was employed to identify heterogeneity causes. Sub-group analysis was performed to assess the effect of early ROM. Results. Nine study fit inclusion criteria. If early ROM is employed, re-rupture rates were equal for surgical and non-surgical patients (RD 0.6% p=0.782). If functional treatment is not employed, the absolute risk reduction achieved by surgery was 8.8% (p=0.002). Surgery was associated with an absolute risk increase of 15.7% (p=0.026) for overall complications. Surgical patients returned to work 19.16 days sooner (p=0.0014). There was no statistically significant difference between the two treatments in terms of calf circumference (p=0.357), strength (p=0.806), or functional outcomes (p=0.226). Conclusion. According our results, for centers using functional rehabilitation, conservative treatment should be preferred, as it results in similar re-rupture rates as surgical treatment, while offering the advantage of decreased overall complications. For centers that do not employ early ROM protocols, surgical repair can be considered as it decreases re-rupture risk


Bone & Joint Open
Vol. 1, Issue 10 | Pages 628 - 638
6 Oct 2020
Mott A Mitchell A McDaid C Harden M Grupping R Dean A Byrne A Doherty L Sharma H

Aims

Bone demonstrates good healing capacity, with a variety of strategies being utilized to enhance this healing. One potential strategy that has been suggested is the use of stem cells to accelerate healing.

Methods

The following databases were searched: MEDLINE, CENTRAL, EMBASE, Cochrane Database of Systematic Reviews, WHO-ICTRP, ClinicalTrials.gov, as well as reference checking of included studies. The inclusion criteria for the study were: population (any adults who have sustained a fracture, not including those with pre-existing bone defects); intervention (use of stem cells from any source in the fracture site by any mechanism); and control (fracture healing without the use of stem cells). Studies without a comparator were also included. The outcome was any reported outcomes. The study design was randomized controlled trials, non-randomized or observational studies, and case series.