The purpose of this study was to develop a quality appraisal tool for the assessment of laboratory basic science biomechanical studies. Materials andScore development comprised of the following phases: item identification/development, item reduction, content/face/criterion validity, weighting, test-retest reliability and internal consistency. For item identification/development, the panel was asked to independently list criteria and factors they considered important for cadaver study and generate items that should be used to appraise cadaver study quality. For content validity, the content validity ratio (CVR) was calculated. The minimum accepted content validity index (CVI) was set to 0.85. For weighting, equal weight for each item was 6.7% [15 items]. Based on these figures the panel was asked to either upscale or downscale the weight for each item ensuring that the final sum for all items was 100%. Face validity was assessed by each panel member using a Likert scale from 1–7. Strong face validity was defined as a mean score of >5. Test-retest reliability was assessed using 10 randomly selected studies. Criterion validity was assessed using the QUACS scale as standard. Internal consistency was assessed using Cronbach's alpha. Five items reached a CVI of 1 and 10 items a CVI of 0.875. For weighting five items reached a final weight of 10% and ten items 5%. The mean score for face validity was 5.6. Test-retest reliability ranged from 0.78–1.00 with 9 items reaching a perfect score. Criterion validity was 0.76 and considered to be strong. Cronbach's alpha was calculated to be 0.71 indicating acceptable internal consistency. The new proposed quality score for basic science studies consists of 15 items and has been shown to be reliable, valid and of acceptable internal consistency. It is suggested that this score should be utilised when assessing basic science studies.
Systematic reviews (SR) can provide physicians with effective means to further strengthen their practice and identify gaps in clinical knowledge. The focus of any SR is to identify the current state of evidence for a given treatment or condition, with the hopes of providing the best interventional methods physicians can base their practice on. In paediatric orthopaedics, high-level studies are lacking, thus potentially limiting the effectiveness of SRs in the field. There isn't one specific way to qualify research on its effectiveness, but there has been gradual enhancement in finding ways to identify a successful and reproducible study. The purpose of this study was to evaluate the quality of paediatric orthopaedic SRs, and highlight aspects of these SRs that have contributed to improved outcomes. A literature review was performed in EMBASE, MEDLINE and Cochrane databases to identify pre-existing systematic reviews that have been published in five well-known orthopaedic journals between 2007 and 2017. SRs were included if the study population was between 0 and 18 years of age. Selected articles had an AMSTAR checklist applied in order to score the studies on their quality and methodology. Articles were independently reviewed by two reviewers to determine the extent of AMSTAR guidelines fulfillment. A total of 40 SRs were identified and reviewed, 20 of which partially or completely fulfilled AMSTAR guidelines. There was no disagreement between reviewers as to which of the analyzed articles have successfully reflected the checklist. Only 20/40 SRs analyzed at least partially fulfilled AMSTAR guidelines. One of the weaknesses identified in the reviewed papers so far is the lack of justification for the chosen study designs for SRs and what strategy was used to decide on the exclusion of articles. There needs to be clear-cut criteria that mark studies to be included and excluded in a comprehensive systematic review. Further improvements are required to ensure that full details on the involvement of papers and the success rates regarding each interventional method are included in order to strengthen the quality of SRs across the paediatric orthopaedic literature.
We evaluated the quality of guidelines on thromboprophylaxis
in orthopaedic surgery by examining how they adhere to validated
methodological standards in their development. A structured review
was performed for guidelines that were published between January
2005 and April 2013 in medical journals or on the Internet. A pre-defined
computerised search was used in MEDLINE, Scopus and Google to identify
the guidelines. The AGREE II assessment tool was used to evaluate
the quality of the guidelines in the study. Seven international and national guidelines were identified.
The overall methodological quality of the individual guidelines
was good. ‘Scope and Purpose’ (median score 98% interquartile range
(IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%,
IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’
(median score 68%, IQR 45% to 75%) and ‘Editorial Independence’
(median score 71%, IQR 68% to 75%) had the lowest scores. These findings reveal that although the overall methodological
quality of guidelines on thromboprophylaxis in orthopaedic surgery
is good, domains within their development, such as ‘Applicability’
and ‘Editorial Independence’, need to be improved. Application of
the AGREE II instrument by the authors of guidelines may improve
the quality of future guidelines and provide increased focus on
aspects of methodology used in their development that are not robust. Cite this article: Bone Joint J 2014;96-B:19–23.
Pedicle screw fixation is a technically demanding procedure with potential difficulties and reoperation rates are currently on the order of 11%. The most common intraoperative practice for position assessment of pedicle screws is biplanar fluoroscopic imaging that is limited to two- dimensions and is associated to low accuracies. We have previously introduced a full-dimensional position assessment framework based on registering intraoperative X-rays to preoperative volumetric images with sufficient accuracies. However, the framework requires a semi-manual process of pedicle screw segmentation and the intraoperative X-rays have to be taken from defined positions in space in order to avoid pedicle screws' head occlusion. This motivated us to develop advancements to the system to achieve higher levels of automation in the hope of higher clinical feasibility. In this study, we developed an automatic segmentation and X-ray adequacy assessment protocol. An artificial neural network was trained on a dataset that included a number of digitally reconstructed radiographs representing pedicle screw projections from different points of view. This model was able to segment the projection of any pedicle screw given an X-ray as its input with accuracy of 93% of the pixels. Once the pedicle screw was segmented, a number of descriptive geometric features were extracted from the isolated blob. These segmented images were manually labels as ‘adequate’ or ‘not adequate’ depending on the visibility of the screw axis. The extracted features along with their corresponding labels were used to train a decision tree model that could classify each X-ray based on its adequacy with accuracies on the order of 95%. In conclusion, we presented here a robust, fast and automated pedicle screw segmentation process, combined with an accurate and automatic algorithm for classifying views of pedicle screws as adequate or not. These tools represent a useful step towards full automation of our pedicle screw positioning assessment system.
In cases of poor bone quality intraoperative torque measurement might be an alternative to preoperative dual energy x-ray absorptiometry (DXA) to assess bone quality in Total Hip Arthroplasty (THA). 14 paired fresh frozen human femurs were included for trabecular peak torque measurement. We evaluated an existing intraoperative torque measurement method to assess bone quality and bone strength. We modified the approach to use this method in total hip arthroplasty (THA), which has not been published before. Since there are several approaches used in THA to exposure the hip joint, we decided to prefer the measurement in the femoral head which allows every surgeon to perform this measurement. Here a 6.5 × 23 mm blade was inserted into the proximal femur without harming the lateral cortical bone (figure 1). Further tests of the proximal femur evaluated the results of this new method: DXA, micro-computed tomography (μCT) and biomechanical load tests. Basic statistical analyses and multiple regressions were done. In the femoral head mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT and the biomechanical load test. In comparison to the bone mineral density captured by DXA, the results of the intraoperative torque measurement showed a superior correlation with high sensitive bone quality evaluating methods (mechanical load tests and micro-computed tomography). Hence, the use of this intraoperative torque measurement seems to be more accurate in evaluating bone strength and bone quality than DXA during THA. The torque measurement provides sensitive information about the bone strength, which may affect the choice of implant in cases of poor bone stock and osteoporosis. In clinical use the surgeon may alter the prosthesis if the device indicates poor bone quality. Furthermore, we assume that the disadvantages associated with DXA scans like radiation exposure or errors caused by potential extraosteal sclerosis and interindividual soft-tissue artifacts could be excluded.
Background. The identification of novel biomarker which is highly specific and sensitive for periprosthetic joint (PJI) have the potential to improve diagnostic accuracy and ultimately improve patient outcomes. Thus, the aim of this systemic review is to identify and evaluate novel biomarkers for the preoperative diagnostics of PJI. Methods. MEDLINE, EMBASE, PubMed and Cochrane Library databases identified from 1. st. of January 2018 to 30. th. of September. 2022. We used “periprosthetic joint infection” OR “prosthetic joint infection” OR “periprosthetic infection” as the diagnosis of interest and the target index applied AND “marker”. To focus on novel biomarkers already used biomarkers of the established PJI diagnostic criteria of MSIS, ICM and EBJIS were not included in the analysis. These three criteria were considered the reference standard during
Aim. The objective of this systematic review is to evaluate the current evidence for or against this up-and-coming treatment modality. Method. A comprehensive literature search in accordance with the Preferred Reporting Items for Systematic review and Meta-analysis (PRISMA) guidelines was conducted using PubMed, Embase, MEDLINE and Cochrane databases. Exclusion criteria included patients < 18 years of age, follow-up <11 months, and a score < 6 on the National Institute of Health
Heterotopic Ossification (HO) is a known complication that can arise after total elbow arthroplasty (TEA). In most cases it is asymptomatic, however, in some patients it can limit range of motion and lead to poor outcomes. The objective of this review was to assess and report incidence, risk factors, prophylaxis, and management of HO after TEA. A systematic search was conducted using MEDLINE, EMBASE, and PubMed to retrieve all relevant studies evaluating occurrence of HO after TEA. The search was performed in duplicate and a
Reverse total shoulder arthroplasty (RSA) with glenoid bone grafting has become a common option for the management of significant glenoid bone loss and deformity associated with glenohumeral osteoarthritis. Despite the increasing utilization of this technique, our understanding of the rates of bone graft union, complications and outcomes are limited. The objectives of this systematic review are to determine 1) the overall rate of bone graft union, 2) the rate of union stratified by graft type and technique, 3) the reoperation and complication rates, and 4) functional outcomes, including range of motion (ROM) and functional outcome scores following RSA with glenoid bone grafting. A comprehensive search of MEDLINE, Embase, and CINAHL databases was completed for studies reporting outcomes following RSA with glenoid bone grafting. Inclusion criteria included clinical studies with greater than 10 patients, and minimum follow up of one year. Studies were screened independently by two reviewers and
The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) remains controversial, even though SONK usually involves only medial compartment of the knee joint. We aimed to compare the survival rate and clinical outcomes of UKA in SONK and medial compartment osteoarthritis (MOA) via a meta-analysis of previous studies. MEDLINE database in PubMed, the Embase database, and the Cochrane Library were searched up to January 2018 with keywords related to SONK and UKA. Studies were selected with predetermined inclusion criteria: (1) medial UKA as the primary procedure, (2) reporting implant survival or clinical outcomes of osteonecrosis and osteoarthritis, and (3) follow-up period greater than 1 year.
PURPOSE. YouTube is a video sharing platform that is a common resource for patients seeking medical information. The objective of this study is to assess the educational quality of YouTube videos pertaining to total knee arthroplasty and knee arthritis. METHODS. A systematic search for the terms “knee replacement” and “knee arthritis” was performed using Youtube's search function. Data from the 60 most relevant videos were collected for each search term. Videos not in English or those without audio or captions were excluded.
Aim. Despite advances in surgical and antibiotic therapies the treatment of chronic osteomyelitis remains complex and is often associated with a significant financial burden to the National Health Service. The aim of this review was to identify the different types of single-stage procedures being performed for this condition as well as to evaluate their effectiveness. Method. Ovid Medline and Embase databases were searched for articles on the treatment of chronic osteomyelitis over the last 20 years. 3511 journal abstracts were screened by 3 independent reviewers. Following the exclusion of paediatric subjects, animal models, non-bacterial osteomyelitis and patients undergoing multiple surgical procedures we identified 13 studies reported in English with a minimum follow up of 12 months. Following a
Aim. Fracture related infection (FRI) remains a challenging diagnosis in orthopedic and trauma surgery. In addition to clinical signs and imaging, serum inflammatory markers are often used to estimate the probability of FRI. To what extent serum inflammatory markers can be used to rule out and diagnose FRI remains unclear. The aim of this systematic review was to assess the diagnostic value of the serum inflammatory markers C-reactive protein (CRP), leukocyte count (LC) and erythrocyte sedimentation rate (ESR) in suspected fracture related infection. Method. PubMed, Embase and Cochrane databases were searched for all articles focusing on the diagnostic value of CRP, LC and ESR in FRI. Studies on other inflammatory markers or other types of orthopedic infection, such as periprosthetic and diabetic foot infections, were excluded. For each serum inflammatory marker, all reported sensitivity and specificity combinations were extracted and graphically visualized. Average estimates were obtained using bivariate mixed effects models. This study utilized the QUADAS-2 criteria and was reported following the PRISMA statement. Results. The search resulted in 8280 articles, of which seven were eligible for inclusion. One study was excluded after
Disorders of bone integrity carry a high global disease burden, frequently requiring intervention, but there is a paucity of methods capable of noninvasive real-time assessment. Here we show that miniaturized handheld near-infrared spectroscopy (NIRS) scans, operated via a smartphone, can assess structural human bone properties in under three seconds. A hand-held NIR spectrometer was used to scan bone samples from 20 patients and predict: bone volume fraction (BV/TV); and trabecular (Tb) and cortical (Ct) thickness (Th), porosity (Po), and spacing (Sp).Aims
Methods
This study explored the shared genetic traits and molecular interactions between postmenopausal osteoporosis (POMP) and sarcopenia, both of which substantially degrade elderly health and quality of life. We hypothesized that these motor system diseases overlap in pathophysiology and regulatory mechanisms. We analyzed microarray data from the Gene Expression Omnibus (GEO) database using weighted gene co-expression network analysis (WGCNA), machine learning, and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analysis to identify common genetic factors between POMP and sarcopenia. Further validation was done via differential gene expression in a new cohort. Single-cell analysis identified high expression cell subsets, with mononuclear macrophages in osteoporosis and muscle stem cells in sarcopenia, among others. A competitive endogenous RNA network suggested regulatory elements for these genes.Aims
Methods
The proportion of younger patients undergoing total knee arthroplasty (TKA) is increasing and predictions state that the 45–54 age group will be the fastest growing group by 2030. We aim to collate data across studies to assess functional outcomes following total knee replacement in patients under 55 years of age. Secondary outcomes include implant survival and complications will also be reviewed. The search identified 980 studies for title and abstract review. 43 full-texts were then assessed. 13 studies underwent
In the UK, the NHS generates an estimated 25 megatonnes of carbon dioxide equivalents (4% to 5% of the nation’s total carbon emissions) and produces over 500,000 tonnes of waste annually. There is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. The primary aim of this study was to analyze the environmental impact of orthopaedic surgery and the environmentally sustainable initiatives undertaken to address this. The secondary aim of this study was to describe the barriers to making sustainable changes within orthopaedic surgery. A literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines through EMBASE, Medline, and PubMed libraries using two domains of terms: “orthopaedic surgery” and “environmental sustainability”.Aims
Methods
Purpose. Surgical repair is the preferred method of treatment of acute Achilles ruptures in North America because, despite a higher risk of overall complications, it offers a reduced risk of re-rupture. However, more recent trials, particularly those using functional bracing with early range of motion (ROM) have challenged this statement. This meta-analysis aims to compare surgical to conservative treatment in respect to re-rupture, overall complications, return to work, calf circumference and functional outcomes, as well as to examine the effects of early ROM on re-rupture rate. Method. Literature search, data extraction, and
Orthopaedic infection is a potentially serious complication of elective and emergency trauma and orthopaedic procedures, with a high associated burden of morbidity and cost. Optimization of vitamin D levels has been postulated to be beneficial in the prevention of orthopaedic infection. This study explores the role of vitamin D in orthopaedic infection through a systematic review of available evidence. A comprehensive search was conducted on databases including Medline and Embase, as well as grey literature such as Google Scholar and The World Health Organization Database. Pooled analysis with weighted means was undertaken.Aims
Methods
Bone demonstrates good healing capacity, with a variety of strategies being utilized to enhance this healing. One potential strategy that has been suggested is the use of stem cells to accelerate healing. The following databases were searched: MEDLINE, CENTRAL, EMBASE, Cochrane Database of Systematic Reviews, WHO-ICTRP, ClinicalTrials.gov, as well as reference checking of included studies. The inclusion criteria for the study were: population (any adults who have sustained a fracture, not including those with pre-existing bone defects); intervention (use of stem cells from any source in the fracture site by any mechanism); and control (fracture healing without the use of stem cells). Studies without a comparator were also included. The outcome was any reported outcomes. The study design was randomized controlled trials, non-randomized or observational studies, and case series.Aims
Methods