Advertisement for orthosearch.org.uk
Results 1 - 20 of 59
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 3 - 3
4 Jun 2024
Jamjoom B Siddiqui B Salem H Raglan M Dhar S
Full Access

Background. The literature on the outcome of revision total ankle arthroplasty (TAA) remains limited. We aim to report the clinical and radiological outcomes of revision TAA at a high-volume centre in the UK. Methods. Retrospective review of 28 patients that underwent 29 revision TAA procedures using INBONE II prosthesis. Demographic, radiological, and patient reported outcome measures data were analysed. Results. The mean (range) duration from primary TAA to revision was 87.5 (16–223) months. The main indication for the revision was aseptic loosening of the primary TAA (82.8%). Additional procedures were required in 75.9% of patients. At mean (range) follow-up of 40 (24- 60) months, the infection, re-operation, and implant survival rates were 6.9%, 6.9% and 96.5% respectively. A significant postoperative improvement in the component alignment radiographic measures was observed. Osteolysis, subsidence, loosening and heterotopic ossification rates were comparable to other reports and did not influence the clinical outcome. A significant improvement was observed in the MOXFQ (all domains) and the EQ-5D (three domains) at 24 months postoperatively. Conclusions. Revision TAA using INBONE II was associated with good short-term survival and improvement in the postoperative scores at 2 years. Maintenance of the postoperatively improved alignment was documented at follow up. The relatively high survival rate in this series supports the notion that revision TAA is a satisfactory option for failed primary TAA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 8 - 8
1 Nov 2014
Titchener A Duncan N Rajan R
Full Access

Introduction:. This study evaluates the mid-term results of first metatarsophalangeal joint replacement (MTPJR) for hallux rigidus using the Toefit-Plus™ prosthesis. Methods:. We prospectively studied the outcomes of 86 MTPJR in 73 patients using the AOFAS-HMI score and radiological follow up over a period from 2006 to 2013, with surgeries performed by a single surgeon at two centres. Patients were reviewed, scored and radiographs obtained pre-operatively and then at intervals of 6 weeks, 6 months, 12 months and then yearly. The mean follow up was 33 months (2–72). Results:. The mean AOFAS score of the patients not requiring revision at 1 year was 92, at 2 years was 94, at 3 years was 91, at 4 years was 99, at 5 years was 93, at 6 years was 100 and at 7 years was 97. 18 joints have either been revised or listed for revision giving a revision rate of 21%; this occurred at a mean of 33 months post-surgery. Reasons for revision included loosening of components in 13, infection in 1, dislocation in 2, malalignment in 1 and persistent pain in 1. Eight patients sustained intra-operative fractures requiring circlage wiring, of which 7 went on to union and one required revision. 25 patients had evidence of radiological loosening of which 22 were around the phalangeal component and 3 were around the metatarsal component. Conclusions:. First MTPJ replacement resulted in improved outcomes in patients with hallux rigidus who do not require revision in the medium term, however the revision rate is unacceptably high and as such we have discontinued use of this prosthesis. Radiological loosening of the components is high and needs monitoring for progression which may necessitate revision


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 31 - 31
1 Apr 2013
Nagy M Walker C Sirikonda S
Full Access

Introduction. There are a number of options available for surgical management of hallux rigidus. Ceramic implants of the first metatarsophalangeal joint (MTPJ) have been available for years; however there are no published long-term results existing. Methods. We performed a retrospective review of all consecutive first MTPJ replacements carried out for later stage hallux rigidus using second generation MOJE ceramic implant with press-fit design. Two specialised foot and ankle surgeons performed these operations at a tertiary referral centre. Patient underwent regular follow ups including clinical review, functional scoring (AOFAS and FFI) and assessment of radiographs. Kaplan Meyer Survival analysis was performed. Results. Our study included 31 prostheses in 24 female patients. Average age at operation was 55.3 years and average follow up time was 80 months. No patients were lost until follow up. Complications included one case of superficial infection and five cases of revision, reasons being fracture of the prostheses (1), unexplained pain (1), subluxation (1) and loosening/sinkage of the implant (2). Prosthesis survival rate was 85.2% at seven years. Assessment of the radiographs showed considerable sinkage of the prosthesis in 43%, tilting in 33% and loosening of the implant in 40.9%. Average postoperative AOFAS score was 71.6 and the average FFI was 27.7. 84% of the patients were satisfied with the results of their operation. Conclusion. Surgery has failed to preserve the function and increase the range of movement in most cases in the long duration. From the patients perspective however the satisfaction with the procedure suggests a success of the implant. Due to poor radiological results and high revision rate we do not recommend the routine use of this prosthesis and all patients that have this type of prosthesis need regular follow up consultations at least yearly with radiographs to assess the position of the implant


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 443 - 446
1 Apr 2019
Kurokawa H Taniguchi A Morita S Takakura Y Tanaka Y

Aims

Total ankle arthroplasty (TAA) has become the most reliable surgical solution for patients with end-stage arthritis of the ankle. Aseptic loosening of the talar component is the most common complication. A custom-made artificial talus can be used as the talar component in a combined TAA for patients with poor bone stock of the talus. The purpose of this study was to investigate the functional and clinical outcomes of combined TAA.

Patients and Methods

Ten patients (two men, eight women; ten ankles) treated using a combined TAA between 2009 and 2013 were matched for age, gender, and length of follow-up with 12 patients (one man, 11 women; 12 ankles) who underwent a standard TAA. All had end-stage arthritis of the ankle. The combined TAA features a tibial component of the TNK ankle (Kyocera, Kyoto, Japan) and an alumina ceramic artificial talus (Kyocera), designed using individualized CT data. The mean age at the time of surgery in the combined TAA and standard TAA groups was 71 years (61 to 82) and 75 years (62 to 82), respectively. The mean follow-up was 58 months (43 to 81) and 64 months (48 to 88), respectively. The outcome was assessed using the Japanese Society for Surgery of the Foot (JSSF) ankle-hindfoot scale, the Ankle Osteoarthritis Scale (AOS), and the Self-Administered Foot Evaluation Questionnaire (SAFE-Q).


Background. Revision total ankle arthroplasty (TAA) can be extremely challenging due to bone loss and deformity. We present the results examining the preliminary indications and short term outcomes for the use of the Salto XT revision prosthesis. Material and methods. We conducted an IRB approved prospective review revision TAA performed in two institutions using the Salto XT. There were 40 patients (24 females and 16 males with an average age of 65 years (45–83), who had undergone previous TAA (Agility 27, Salto 4, STAR 4, Buechal Pappas 1), and 4 patients who underwent staged procedures for infection. The primary indications for the revision were loosening and subsidence (34), malalignment (17), cyst formation (8), infection (4). Results. Severe bone loss of the talus (30) and distal tibia (5) caused by erosion or cysts (8) were treated with cancellous bone graft (33), cement (7), or a combination (12). A press fit of the tibial component was obtained in 25 cases, and of the talus in 17. The talar component was seated directly onto the calcaneus in 4 cases supplemented anteriorly by cancellous bone graft. Patients were followed up for an average of 24.2 months (range 12–36 months). The overall complication rate was 25%. An 85% survivorship of the revision TAA was achieved (4 cases of postoperative infection and 2 cases of implant loosening). At the last follow-up visit, the remaining 34 implants were stable and none had loosened nor failed. Conclusion. Revision ankle replacement with bone loss is a technically challenging procedure with acceptable outcomes for the patient but an 85% survivorship even in the short term. We noted the complexity yet feasibility of performing revision TAA, and determined that the stability of the prosthesis was important. The short term survivorship indicates a likely higher rate of failure in the longer term


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 1 - 1
4 Jun 2024
Jennison T Goldberg A Sharpe I
Full Access

Introduction. Despite the increasing numbers of ankle replacements that are being performed there are still limited studies on the survival of ankle replacements and comparisons between different implants. The primary aim of this study is to link NJR data with NHS digital data to determine the true failure rates of ankle replacements. Secondary outcomes include analysis risk factors for failure, patient demographics and outcomes of individual prosthesis. Methods. A data linkage study combined National Joint Registry Data and NHS Digital data. The primary outcome of failure is defined as the removal or exchange of any components of the implanted device inserted during ankle replacement surgery. Life tables and Kaplan Meier survival charts demonstrated survivorship. Cox proportional hazards regression models with the Breslow method used for ties were fitted to compare failure rates. Results. 5,562 primary ankle replacement were recorded on the NJR. The 1-year survivorship was 98.8% (95% CI 98.4%–99.0%), 5-year survival in 2725 patients was 90.2% (95% CI 89.2%–91.1%), and 10-year survival in 199 patients was 86.2% (95% CI 84.6%–87.6%). When using a Cox regression model for all implants with over 100 implantations using the Infinity as the reference, only the Star (Hazard ratio 1.60 95% CI 0.87–2.96) and Inbone (HR 0.38 95% CI 0.05–2.84) did not produce significantly worse survivorship. Conclusion. Ankle replacements have increased in numbers over the past decade, and the currently used implants have lower failure rates than older prosthesis. It is expected that in the future the outcomes of ankle replacements will continue to improve


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 2 - 2
4 Jun 2024
Townshend D Bing A Clough T Sharpe I Blundell C Davenport J Davies H Davis J Dhar S Goldberg A Karski M Hepple S Kakwani R McKinley J Murty A Ragland M Shalaby H Smith R Taylor H
Full Access

Introduction. This is a multi-centre, prospective, observational study of 503 INFINITY fixed bearing total ankle arthroplasties. We report the minimum two-year results of this prosthesis which was introduced to the UK Market in 2014 and is now the most used ankle arthroplasty in the National Joint Registry of England and Wales. Methods. Patients were recruited from 11 centres in the United Kingdom between June 2016 and November 2019. Demographic, radiographic, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Foot Ankle Questionnaire and Euroquol 5D-5L) were collected preoperatively, at 6 months, 1 year and 2 years and 5 years. The average age was 67.8 (range 23.9 to 88.5) and average BMI 29.3 (18.9 to 48.0). The COFAS grading system was used to stratify deformity. There were 261 (51.9%) COFAS Type 1, 122 (24.2%) COFAS Type 2, 31 (6.2%) COFAS 3 and 89 (17.7%) COFAS type 4. 38 patients (7.6%) presented with inflammatory arthritis. 99 (19.7%) implantations utilised patient specific instrumentation. Complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts and/or subsidence. Results. The mean follow up was 34.2 months (range 24–64). 15 patients have died, 8 withdrawn and 3 lost to follow up. 8 implants (1.6%) have been revised. According to the Glazebrook classification there were low grade complications in 6.6%, medium grade in 1.4% and high grade in 1.6%. There have been an additional 13 non revision re-operations (2.6%) at the latest follow up. There was a significant (p < 0.01) improvement across all functional outcome scores at a minimum of 2yr follow up. Discussion and conclusion. This large cohort has shown a low early revision rate and high functional outcomes with a low-profile fixed bearing prosthesis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 21 - 21
10 Jun 2024
Gordon C Raglan M Dhar S Lee K
Full Access

Objective. The purpose of this study was to determine the outcomes of revision ankle replacements, using the Invision implant and impaction allograft for massive talar dome defects following primary ankle replacement failure. Outcomes were assessed in terms of bone graft incorporation; improvement in patient reported outcome measures (PROMs); and survivorship of the revision ankle arthroplasty. Methods. A retrospective review of prospectively collected data identified eleven patients who had massive bone cysts and underwent revision of a failed primary total ankle replacement to the Invision revision system, combined with impaction grafting using morselized femoral head allograft. These revisions occurred at a single high volume ankle arthroplasty centre. Computed tomography (CT) scans were used to assess bone graft incorporation and the Manchester-Oxford Foot Questionnaire (MOXFQ) and EQ-5D scores were used pre and post operatively to assess PROMs. Results. The mean follow up was 18 months (12–48months). In all eleven patients, improvement was reported in the post-operative MOXFQ and EQ-5D scores. CT scans showed bone graft incorporation in all cases. None of the patients have required further surgery and are continue to do well clinically at latest follow up. Conclusions. In the short term, this study confirms revision ankle replacements with the Invision prosthesis and impaction with morselized femoral head allograft is a suitable revision option for primary ankle replacement failure with massive talar bone loss. Long term follow up continues of these complex patients


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims

Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK.

Methods

A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims

Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined.

Methods

This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims

The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant.

Methods

This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1502 - 1507
1 Nov 2017
Hong CC Tan JH Lim SH Nather A

Aims. Limb salvage for diabetic foot infections often require multiple procedures. Some patients will eventually end up with below knee amputation (BKA) when all limb salvage attempts fail. We seek to study the patients’ ability to return to normal life, functional status, prosthesis usage and perspectives on multiple limb salvage procedures that culminated in BKA to review if they would undertake a similar path if their situation was repeated. Patients and Methods. A total of 41 patients who underwent BKA between July 2011 and June 2013 were reviewed. They were divided into primary and creeping (prior multiple salvage procedures) amputations. The Barthel’s Index (BI) and the Reintegration to Normal Living Index (RNLI) were used. A questionnaire was used to identify whether the patient would undergo the same multiple attempts at limb salvage again if faced with the same problem. Results. All patients had a good mean BI of 14.2 (3 to 20) and RNLI of 73.2 (31 to 100). There was no difference in prosthesis usage, BI and RNLI between both groups. We found that 16 (94.1%) out of 17 patients with creeping amputation would undergo the same multiple salvage procedures if given a similar option. Conversely, only 15 (62.5%) patients with primary amputation would do the same again while the other nine (37.5%) patients choose to do everything possible to save their leg if faced with a similar situation (p = 0.001). Conclusion. Most patients preferred to undergo multiple procedures to salvage the limb from diabetic foot infection even if it ultimately concluded with a BKA. All the patients had a moderately good functional outcome and ability to return to normal living after BKA. Cite this article: Bone Joint J 2017;99-B:1502–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1529 - 1533
1 Nov 2012
Taniguchi A Takakura Y Sugimoto K Hayashi K Ouchi K Kumai T Tanaka Y

The purpose of this study was to evaluate the clinical results of a newly designed prosthesis to replace the body of the talus in patients with aseptic necrosis. Between 1999 and 2006, 22 tali in 22 patients were replaced with a ceramic prosthesis. A total of eight patients were treated with the first-generation prosthesis, incorporating a peg to fix into the retained neck and head of the talus, and the remaining 14 were treated with the second-generation prosthesis, which does not have the peg. The clinical results were assessed by the American Orthopaedic Foot and Ankle Society ankle/hindfoot scale. The mean follow-up was 98 months (18 to 174). The clinical results of the first-generation prostheses were excellent in three patients, good in one, fair in three and poor in one. There were, however, radiological signs of loosening, prompting a change in design. The clinical results of the second-generation prostheses were excellent in three patients, good in five, fair in four and poor in two, with more favourable radiological appearances. Revision was required using a total talar implant in four patients, two in each group. Although the second-generation prosthesis produced better results, we cannot recommend the use of a talar body prosthesis. We now recommend the use of a total talar implant in these patients


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 472 - 478
1 Apr 2022
Maccario C Paoli T Romano F D’Ambrosi R Indino C Federico UG

Aims

This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years.

Methods

We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 47 - 54
1 Jan 2019
Clough T Bodo K Majeed H Davenport J Karski M

Aims. We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Patients and Methods. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year. Results. A total of 84 patients (87 ankles) were alive by the end of this study. Of the surviving 84 patients (87 ankles; rheumatoid arthritis (RA), n = 40; OA, n = 47), 45 were women and 39 were men, with a mean age of 54 years (18 to 72 years) at the time of surgery. A total of 32 implants failed (16%), requiring revision surgery. The mean time to revision was 80 months (2 to 257). The implant survival at 15.8 years, using revision as an endpoint, was 76.16% (95% confidence interval (CI) 64.41 to 87.91). We found a steady but low decrease in survival over the study period. The mean AOFAS score improved from 28 (10 to 52) preoperatively to 61 (20 to 90) at long-term follow-up. Conclusion. STAR prostheses in the United Kingdom have now been largely superseded by newer design TAAs, potentially with improved characteristics and surgical techniques. The long-term survivorship for the STAR prosthesis can provide a benchmark for these later designs of ankle arthroplasty


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 2 - 2
1 Nov 2014
Harris N Hendricson A Rydholm U Knutson K Popelka S
Full Access

Introduction:. We present the early results of 220 Rebalance Total Ankle Replacements performed in 6 centres in 4 different countries. Methods:. The Rebalance Total Ankle Replacement is a new 3 component uncemented mobile bearing prosthesis with a surface coating of ‘bonemaster’ and an ‘e’ poly bearing. The prosthesis was released in a limited way in May 2011. Since then 220 replacements have been implanted in 218 patients in 6 centres in 4 different countries (UK, Sweden, Canada, Czech Republic). All the x-rays and case notes were reviewed.63 prostheses have a minimum follow up of 2 years. Outcome measures included revision of the prosthesis, and the incidence of progressive and non-progesssive radiolucent lines around the prosthesis. Results:. 7 patients underwent revision or are awaiting revision of their prosthesis. Reasons for revision included loosening(2), infection(1), malposition(2), periprosthetic fracture(1), impingement(1). 9 patients had non-progressive radiolucent lines and 2 patients had progressive radiolucent lines. 1 patient with progressive radiolucent lines is waiting revision for suspected infection. 8 patients suffered fractures to the lateral malleolus and 4 to the medial malleolus. There were no cases of balloon osteolysis. 29 patients had pre-op AOFAS scores= 41(12–67). 21 had 1 year post-op AOFAS scores= 73.5(26–100). 12 had 2 year AOFAS scores= 75.5(50–100). Conclusion:. The early results are encouraging and we believe support its wider use


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 24 - 24
1 Dec 2015
McEntee L Killen M Karpe P Limaye R
Full Access

Background. Hallux rigidus is a degenerative condition of the first metatarsophalangeal joint (MTPJ) of the great toe, which can result in significant pain and stiffness. Treatment using joint replacement, either by means of hemiarthroplasty or total arthroplasty of the metatarsophalangeal joint is becoming an increasingly popular option for patients with severe disease. Aim. To evaluate mid-term functional and radiological outcomes of a widely used first generation resurfacing arthroplasty system in the treatment of hallux rigidus. Method. Prospective review of patients from 2009 onwards. All patients were operated on by the senior author using the same first generation hemiarthroplasty prosthesis (HemiCAP®, Arthrosurface, USA) and surgical technique. Radiological and clinical outcomes were assessed at 3, 6, 12 and 24 months post-operatively. Patients were assessed pre- and post-operatively on an outpatient basis for MTPJ range of motion as well as outcomes using AOFAS and visual analogue scale scores. Results. 20 prostheses in 19 patients over a two year period. Mean follow-up was 18 months (range 12–24). Mean AOFAS score improved from 38.66 pre-operatively to 74.93 at 12 months post-operatively. Mean VAS score improved from 9.95 pre-operatively to 4.05 post-operatively. There was radiological subsidence in one patient. 5 patients (26%) required revision to arthrodesis due to ongoing pain and stiffness. Conclusion. Despite significant improvements in functional scores and positive radiological outcomes in most patients, we have seen high revision rates with this first generation prosthesis due to ongoing pain and stiffness. Since this study, there has been a redesign of this implant with the addition of a dorsal flange, but the first generation prosthesis still remains in use. Following our results, we have discontinued our use of this product in favour of either the newer generation hemiarthroplasty or total arthroplasty system for patients with severe hallux rigidus


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 696 - 703
1 Apr 2021
Clough TM Ring J

Aims

We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre.

Methods

Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1525 - 1532
1 Nov 2015
Cho J Yi Y Ahn TK Choi HJ Park CH Chun DI Lee JS Lee WC

The purpose of this study was to evaluate the change in sagittal tibiotalar alignment after total ankle arthroplasty (TAA) for osteoarthritis and to investigate factors affecting the restoration of alignment. . This retrospective study included 119 patients (120 ankles) who underwent three component TAA using the Hintegra prosthesis. A total of 63 ankles had anterior displacement of the talus before surgery (group A), 49 had alignment in the normal range (group B), and eight had posterior displacement of the talus (group C). Ankles in group A were further sub-divided into those in whom normal alignment was restored following TAA (41 ankles) and those with persistent displacement (22 ankles). Radiographic and clinical results were assessed. Pre-operatively, the alignment in group A was significantly more varus than that in group B, and the posterior slope of the tibial plafond was greater (p < 0.01 in both cases). The posterior slope of the tibial component was strongly associated with restoration of alignment: ankles in which the alignment was restored had significantly less posterior slope (p < 0.001). . An anteriorly translated talus was restored to a normal position after TAA in most patients. We suggest that surgeons performing TAA using the Hintegra prosthesis should aim to insert the tibial component at close to 90° relative to the axis of the tibia, hence reducing posterior soft-tissue tension and allowing restoration of normal tibiotalar alignment following surgery. Cite this article: Bone Joint J 2015;97-B:1525–32


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 26 - 26
1 Apr 2013
Ahluwalia R Cooke P Rogers M Sharp R
Full Access

Introduction. Ankle replacement is now common in the UK. In a tertiary referral NHS practice, between 1997–2011 we implanted two types of cementless mobile bearing total ankle replacements (TAR). Methods. We reviewed our operative database and electronic patient records and confirmed the number of prosthesis with our theatre records. All case notes and radiographs were reviewed. Failure was taken as revision, and patients were censored due to death or loss to follow-up. The survivorship was calculated using a life table (the Kaplan-Meier method), with 95% confidence intervals. Results. We found a total of 358 NHS patients had a TAR from Jan 1997 to April 2012 total ankle replacements; the mean follow up was 76 months. The principle indications for surgery included primary OA (n=146) and inflammatory arthritis in (n=79). Overall survival was 90.9% (94–84) at 10 years. A complication requiring revision developed in 42 ankles and 36 were revised or fused. Thirty-two TAR's underwent further hind foot fusions which were not attributed as a failure of the prosthesis. We arthroscoped 6 TAR's for hetrotrophic calcification. When we separated the implants we found the STAR (implanted from 1997–2004) had a 5-year survival of 95.2% (98–91) and the Mobility (implanted from 2004–11) of 92.6% (96–88). We found early failures (within 2 years of implantation) were higher within 2 years of introduction of TAR and on changing our prosthesis. Conclusion. In a study of TAR undertaken at one centre principally by an experienced surgeon and team, we have shown a learning curve. Cementless mobile bearing total ankle replacements (TAR) conducted on a routine basis with careful patient selection has a 90.9% survivorship over a 10-year period. The difference in survival for two implants is not statistically significant